Rittal roof-mounted fans Efficiency on top

Similar documents
Rittal roof-mounted fans

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Optimise wire processing A comprehensive range of products for the workshop

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

ClimaSys Resistance heaters Selection guide

Life insurance for your electronics

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

electronics Protection

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Interface and EOL Modules 8

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Heaters, Thermostats and Hygrostats

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

Eldon Product Overview

Thermal management for your cabinets!

Engineering Guideline. pac- Carriers Type Universal

Frequently asked questions: Intelligent Transmitter Series

Instrumentation Products and Applications

DTA. Motor thermistor relay. Benefits. Description

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Control solutions Biofloor

Enclosure cooling unit

Cooling unit Mechanical control

THERMASREG TR 040 THERMASREG TR 060

Burner control unit BCU 370

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Air Shower TECHNICAL DATA

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Product Management, Rev 3 December 2009

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Speed and Frequency Seite 1 von 7

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

NEW GENERATION. Efficient use of valuable space INCUBATORS

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

OEM Alpha Thermostat direct Analog

Product data sheet AIRWIN additional modules Accessories AIRWIN

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

LC1350 Level Controller

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

On the job around the clock 24/7: Fire detection systems

Ordering Key. Dielectric strength

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Remote alarm indicator and test combination MK2430

Loadstar AC/DC Systems

DTA04. Motor thermistor relay. Benefits. Description

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SmartAlarm Annunciator

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

Climate Control Quick Reference

You are streamlining your manufacturing processes Our automatic machines optimise installation times Let s connect.

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Burner control unit BCU 370

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

Bulletin 1608N MiniDySC Dynamic Sag Corrector

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Thermal Management Products & Accessories for Enclosures

Manual Power relay SR853

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

More Precision. thicknesssensor // The sensor for precise thickness measurements

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

UDC100 Universal Digital Controller Specifications

Stego accessories for cabinets

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

Recalibrate the way you look at gas detection

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Instructions for the fan motor control system, SILVER C

www

The New Cooling Unit Generation Blue e+

Enclosure cooling unit

SecuriSens LIST Product Catalogue 2015

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Table of Content

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Advantages / Characteristics

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Thermostats. Innovative solutions for the toughest requirements

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Transcription:

Rittal roof-mounted fans Efficiency on top

2 Climate control/roof-mounted fans

The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution, climate control and IT infrastructure products together into a single system platform. Complemented by our extensive range of software tools and global service, we create unique added value for trade and industry: Production plant, test equipment, facility management and data centres. In accordance with our simple principle, Faster better everywhere, we are able to combine innovative products and efficient service to optimum effect. Faster with our Rittal The System. range of modular solutions, which guarantees fast planning, assembly, conversion and commissioning with its system compatibility. Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages. Everywhere thanks to global networking: 13 production facilities with almost 250,000 m 2 production space worldwide 58 subsidiaries Around 90 warehouse facilities with more than 180,000 pallet locations and over 260,000 m 2 storage space worldwide Climate control/roof-mounted fans 3

Roof-mounted fans One system for all sizes Simply top Just one mounting cut-out for all output categories (258 x 258 mm) Optimum efficiency, thanks to sophisticated air routing with minimal pressure losses Innovative clamping attachment ensures a high protection category 4 Climate control/roof-mounted fans

Climate control/roof-mounted fans 5

6 Climate control/roof-mounted fans

Roof-mounted fans Easy locking with innovative clamping attachment Simple to fit and maintain Innovative clamping attachment supports flexible locking optionally from the outside or inside Easy electrical connection via plug terminal Good accessibility permits fast filter mat changes Large output range with high efficiency Passive variant without fan for natural convection Air throughput range from 500 1,000 m³/h At an air throughput of 1,000 m³/h, EC fans ensure maximum energy efficiency High protection category IP 55 as standard, thanks to a sophisticated labyrinth system and high-quality foamed-in seal International approvals and permits Climate control/roof-mounted fans 7

Roof-mounted fan, roof vent Accessories for climate control Page 10 Colour: RAL 7035 Protection category IP to IEC 60 529: IP 22 without filter mat IP 55 including filter mat Supply includes: Complete unit ready to install, including filter mat Note: For energy-efficient operation of the fans, we recommend the use of thermostats or temperature displays Approvals: UR cur CSA Further technical information: Available on the Internet Air throughput, unimpeded air flow 500 873 m³/h Model No. Packs of 3138.000 3139.100 3139.110 3140.100 3140.110 3140.140 Page Rated operating voltage V, ~, Hz 230, 1~, 50/60 115, 1~, 50/60 230, 1~, 50/60 115, 1~, 50/60 Air throughput, unimpeded air flow (without filter mats) m³/h Air throughput, unimpeded air flow (with filter mats) m³/h 400, 3~, 50/60 460, 3~, 60 500 / 525 500 / 525 873 / 965 873 / 965 863 / 942 417 / 446 417 / 446 725 / 759 725 / 759 700 / 749 Rated current A 0.22 / 0.27 0.43 / 0.55 0.43 / 0.56 0.88 / 1.17 0.17 / 0.19 Pre-fuse A 6 6 6 6 Motor circuit-breaker A 6.3...10 Power consumption W 50 / 62 49 / 62 98 / 130 101 / 135 90 / 122 Width mm 400 400 400 400 400 400 Height mm 133 133 133 133 133 133 Depth mm 400 400 400 400 400 400 Max. installation depth mm 27.5 34.6 34.6 34.6 34.6 34.6 Required mounting cut-out mm 258 x 258 258 x 258 258 x 258 258 x 258 258 x 258 258 x 258 Fan without fan Radial, capacitor motor tor motor tor motor tor motor current motor Radial, capaci- Radial, capaci- Radial, capaci- Radial, rotary motor Operating temperature range -30 C...+55 C -30 C...+55 C -30 C...+55 C -30 C...+55 C -30 C...+55 C -30 C...+55 C Storage temperature range -40 C...+70 C -40 C...+70 C -40 C...+70 C -40 C...+70 C -40 C...+70 C -40 C...+70 C Accessories Outlet filter 1 pc(s). 3243.200 3243.200 3243.200 3243.200 3243.200 3243.200 Spare filter mats 12 pc(s). 3174.100 3174.100 3174.100 3174.100 3174.100 3174.100 10 Enclosure internal thermostat 1 pc(s). 3110.000 3110.000 3110.000 3110.000 3110.000 11 Digital enclosure internal temperature display and thermostat 1 pc(s). 3114.200 3114.200 3114.200 3114.200 3114.200 11 Hygrostat 1 pc(s). 3118.000 3118.000 3118.000 3118.000 3118.000 11 Cat. 34, 372 8 Climate control/roof-mounted fans

Roof-mounted fans Accessories for climate control Page 10 Energy-efficient and powerful design of the roof-mounted fans. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported. Colour: RAL 7035 Protection category IP to IEC 60 529: IP 22 without filter mat IP 55 including filter mat Supply includes: Complete unit ready to install, including filter mat Note: For even more efficient operation or for monitoring the fans, we recommend the use of the EC speed controls Approvals: UR cur CSA Further technical information: Available on the Internet Air throughput, unimpeded air flow 1069 m³/h, with EC technology Model No. Packs of 3140.500 3140.510 Page Control interface Rated operating voltage V, ~, Hz 230, 1~, 50/60 115, 1~, 50/60 Air throughput, unimpeded air flow (without filter mats) m³/h Air throughput, unimpeded air flow (with filter mats) m³/h 1069 / 1069 1069 / 1069 841 / 841 841 / 841 Rated current A 0.99 / 0.99 1.45 / 1.45 Pre-fuse A 6 6 Power consumption W 129 / 129 106 / 106 Width mm 400 400 Height mm 133 133 Depth mm 400 400 Max. installation depth mm 34.6 34.6 Required mounting cut-out mm 258 x 258 258 x 258 Fan Radial, EC motor Radial, EC motor Operating temperature range -30 C...+55 C -30 C...+55 C Storage temperature range -40 C...+70 C -40 C...+70 C Accessories Outlet filter 1 pc(s). 3243.200 3243.200 Spare filter mats 12 pc(s). 3174.100 3174.100 10 EC speed control 1 pc(s). 3235.440 3235.440 10 1 pc(s). 3235.450 3235.450 10 Enclosure internal thermostat 1 pc(s). 3110.000 3110.000 11 Digital enclosure internal temperature display and thermostat 1 pc(s). 3114.200 3114.200 11 Hygrostat 1 pc(s). 3118.000 3118.000 11 Cat. 34, 372 Climate control/roof-mounted fans 9

Accessories Spare filter mats Made of chopped-fibre mat with a progressive structure. Temperature-resistant to 100 C, selfextinguishing category F1 to DIN 53 438. Dustladen air side: Open structure. Clean-air side: Closed structure. Reliable filtering of virtually all types of dust from a particle size of 10 μm. Design for roof-mounted fans To fit Model No. 3138.../3139.../3140... Material Chemical fibres Width mm 264 Height mm 95 Depth mm 17 Filter class to DIN EN 779 G3 Packs of 12 pc(s). Model No. 3174.100 EC speed control Control unit for EC fan Temperature-dependent speed control for EC fans to reduce noise and save energy. The function of the fan can also be monitored. Functions: Activation and monitoring of up to 4 EC fan-andfilter units For mounting on a 35 mm support rail EN 50 022 External temperature sensor to record the actual temperature Status LED to display the operating status Alarm relay for reporting overtemperature, fan defect, cable break and sensor failure Supply includes: NTC sensor, length 1.80 m 3240.500/3241.500/ To fit Model No. 3243.500/3244.500/ 3245.XXX/3140.500/ 3140.510 Rated operating voltage V 100-250 Setting range +5 C...+55 C Model No. 3235.440 EC speed control Sensor for speed control NTC sensor for temperature-dependent speed control of EC fans to reduce noise and save energy. Activation and power supply via an EC fan-and-filter unit. Technical specifications: Control characteristic: fixed setpoint at 35 C, with linear control range between +35 C (maximum speed 100%) and +20 C (minimum speed 10%) Protection category IP to IEC 60 529: IP 40 Supply includes: External sensor with connection cable (length 3 m) 3240.500/3241.500/ To fit Model No. 3243.500/3244.500/ 3245.XXX/3140.500/ 3140.510 Rated operating voltage V 10-12 (DC) Operating temperature range -25 C...+80 C Model No. 3235.450 10 Climate control/roof-mounted fans

Accessories Enclosure internal thermostat Particularly suitable for controlling fans, heaters and heat exchangers, this thermostat can also be used as a signal generator for monitoring the enclosure internal temperature. Benefits: Time-saving connection technique using a terminal strip with a screw connection from the outside. Flexible mounting on a vertical or horizontal 35 mm support rail to EN 50 022, and snap fastening in the TS/SE enclosure section or on the mounting plate using the supplied adaptor Technical specifications: Bi-metal controller as a temperature-sensitive element with thermal feedback. Contact population: Single-pole change-over contact as a quick-break contact. Permissible contact load: Category 5 3 (heating) AC 10 (4) A (inductive load at cos φ = 0.6)/ category 5-4 (cooling): AC 5 (4) A (inductive load at cos φ = 0.6)/DC = max. 30 W Switching difference: approx. 1 K ± 0.8 K Colour: RAL 7035 Width mm 71 Height mm 71 Depth mm 33.5 24 48-60 115, 1~ Rated operating voltage V, ~ 230, 1~ 24 (DC) 48-60 (DC) Setting range +5 C...+60 C Model No. 3110.000 Hygrostat The hygrostat switches on the heater and/or fan when a preset relative humidity in the enclosure is exceeded. In this way, the relative humidity is reduced, and condensation on assemblies or electronic components is avoided. Benefits: Time-saving connection technique using a terminal strip with a screw connection from the outside. Flexible mounting on a vertical or horizontal 35 mm support rail to EN 50 022, and snap fastening in the TS/SE enclosure section or on the mounting plate using the supplied adaptor Technical specifications: Contact population: Single-pole change-over contact as a quick-break contact. Permissible contact load: AC ~ 5 (0.2) A (inductive load at cos φ = 0.6)/DC = max. 20 W Setting range: 50 100% relative humidity Switching difference: approx. 4% Colour: RAL 7035 Width mm 71 Height mm 71 Depth mm 33.5 Rated operating voltage V, ~ 24-230, 1~ 12-75 (DC) Model No. 3118.000 Digital enclosure internal temperature display and thermostat For installation in the enclosure door or wall. Technical specifications: Three-digit, 7-segment display Option of switching between C/ F Includes 1800 mm long NTC sensor Two relay outputs as change-over contact and normally open contact (max. contact load 230 V, 6 A) Freely selectable switching difference Rated operating voltage V, ~, Hz 100-230, 1~, 50/60 24-60 (DC) Installation depth mm 100 Approvals UR Setting range +5 C...+55 C Operating temperature range +0 C...+50 C Model No. 3114.200 Climate control/roof-mounted fans 11

Easy to convert

Conversion table for roof-mounted fans Air throughput, unimpeded air flow 500 m³/h 800 m³/h 1000 m³/h without fan new 3138.000 old 8801.380 3148.007 230 V new 3139.100 3140.100 3140.500 old 3149.007 3149.420 3149.820 115 V new 3139.110 3140.110 3140.510 old 3169.007 3149.410 3149.810 400 V new 3140.140 old 3149.440 3149.840 Spare filter mats new 3174.100 old 3174.000 3174.000 3174.000 3174.000 400 133 400 258 258

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can find the contact details of all Rittal companies throughout the world here. XWW00060EN1603 www.rittal.com/contact