Omnistat3 Hospitality Energy Management Thermostat

Similar documents
Wireless Plug Load Control

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

What is home automation?

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

ZADE/Room Management System

Appendix A Equipment Used to Monitor Hotels

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

RedLINK Connects RedLINK Wireless Comfort Systems

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

VT8300 Series Installation Guide 24 Vac Low Voltage

Solve Complex Comfort Challenges.

SECTION LIGHTING CONTROLS

OmniPro II. Technical Sheet. DESCRIPTION

Document # R01

VT8600 Series Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Safety & Installation Instructions

The OmniPro II EN50131 and PD6662 Compliant Controller

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

Safety & Installation Instructions

Description Model(s) Page(s) Description Model(s) Page(s) Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...

enviro iq Advanced Comfort Control and Energy Management for the Hospitality Industry

Honeywell ENERGY SAVINGS KIT

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

Safety & Installation Instructions

PECO INC. INNOVATIVE EXPERIENCED RESPONSIVE TEMPERATURE CONTROLS MANUFACTURING

ENERGY EFFICIENCY EXPERTS

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

THX9321R5030/U Prestige 2.0 HD High-definition Color Touchscreen Thermostat, RedLINK enabled

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

CONTENTS. Installation Guide. VT7200 Series

Zoning System Design Manual

Sensors and Detectors

PECO INC. INNOVATIVE EXPERIENCED RESPONSIVE TEMPERATURE CONTROLS MANUFACTURING

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

Vive PowPak Fixture Controls

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

ENTOUCH ONE USER GUIDE

WHAT S IN THE BOX? The IQ Panel also includes a snap on table stand and power supply with cable.

INSTALLATION & OPERATION MANUAL

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Safety & Installation Instructions

Nest Thermostat E Pro Installation & Configuration Guide

The Omni IIe Controller

5900 SERIES Low Energy Power Operator

FAST-STAT. Wiring Extenders

Ever evolving energy code requirements and the large demand for energy

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

T6590 Series FAN-COIL CONTROLLER

T-32-TS Touchscreen Thermostat. Installation Manual

The Omni IIe EN50131 and PD6662 Compliant Controller

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

33CS. Debonair Thermostats SETTING A NEW INDUSTRY STANDARD

RC-2000 Thermostat Installation Instructions

The Omni LTe EN50131 and PD6662 Compliant Controller

Installer Guide. WARNING Important Safety Information. 1 Specifications

Low-Voltage Occupancy Sensors

Spartan Peripheral Devices. TE 256S Thermostat Applications

T7100D Microelectronic Conventional Thermostat

INNtouch PRIVACY MAKE UP ROOM P564


TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

HAI Omni-Bus Network Installation. 5. Typical Application

Occupancy and Vacancy Sensors

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Code Review TITLE PRESENTED BY POURIA NIKNAM

Evaporative Cooling Controls... 1F51 / 8A18Z / 21D Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...

RedLINK Wireless Comfort Systems. RedLINK Connects.

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

Fan Coil Unit (FCU) Application Guide

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Infrared Wall Mount Occupancy Sensor

Wireless High Voltage Digital Thermostat

RCS Residential Control Systems Inc.

Comfort System T-21-P Touchscreen Thermostat Installation Manual

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

Underfloor Catalogue Heating products that define the market

Control4 Wireless Thermostat by Aprilaire. Safety and Installation Guide

Omnistat Architectual Specifications

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

E529 Smart Digital Thermostat Product Guide

THX9321 Prestige 2.0 and. THX9421 Prestige IAQ with EIM APPLICATION FEATURES PRODUCT DATA

PerFormance Pro t4900 school series InstallatIon GUIDe

Professional Model Owner's Manual

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Installation Instructions

Wireless Wall-Mount Sensor

1F98EZ-1421, Easy Install

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

Install Guide CT100. Caution. Caution

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Thermostats. Thermostats

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Wireless Thermostat (WTS10) Keypad Operation Guide

Transcription:

Omnistat3 Hospitality Energy Management Thermostat and the temperature is set back within 1 minutes (adjustable). When the room becomes occupied, key loads are turned on and the temperature returns to the desired set points. For rooms with balcony sensors the HVAC can be turned off or setback when a balcony door is left open. The combination of sensors and logic allow the RC5 thermostat to provide maximum energy savings while allowing occupants to stay comfortable during their stay. RC5 Thermostat, white APPLICATION Designed for hotel rooms and lodging areas, the Omnistat3 Hospitality Thermostat boasts a compact form factor with a clean capacitive touch interface. The Omnistat3 is designed to achieve Title 24 compliance to accurately detect if a hospitality room is occupied, adjusting heat and cool setpoints based on vacancy or occupancy, and to control room loads or circuits if the room is vacant or occupied. The thermostat is directly compatible with the Lumina RF sensor network, combining a built-in occupancy sensor in the face of the thermostat with battery powered RF sensors to monitor activity throughout the room. The secure wireless technology also provides communication with load control modules, allowing devices to be turned off when the room is unoccupied. The Omnistat3 is designed to have an easily replicable installation process, utilizing the USB port to quickly push unified programming logic into each device with free software. HOW IT WORKS The Omnistat3 uses a door/window sensor or hardwired key card switch at the main entrance combined with wireless RF sensors to determine room occupancy. Once occupancy is established, the room remains in an occupied state until the entry door is opened. If the room becomes unoccupied key loads in the room are turned off OPTIONAL ATTACHMENTS Sensors: The on-board sensor combined with optional wireless sensors can detect occupancy and adjust temperatures and loads. The ceiling mount occupancy sensors have wide coverage (either 45 or 1,5 square feet) to detect occupancy. Additionally, a wireless corner mount motion detector, part number LURMD, has 16 of coverage at 9 degrees. The wireless door/window contact has a small form factor for discreet attachment. Load Control: A heavy duty 3A load control module provides control of electrical branch circuits including receptacles, while a 15A plug-in appliance module provides control of small electrical devices that plug-in to receptacles Switches: The ZSS1 wall switch is available in versions with and without a neutral connection, for switched loads including lighting or fans Hardwired Key Card Switch: Available for applications when a key card is used to determine occupancy instead of sensors The Omnistat3 can accept a key card switch input The thermostat will ignore the sensor inputs and instead rely on the state of the card reader When a card is inserted, the thermostat will move to an occupied state When the card is removed, the room will move to unoccupied

ENERGY MANAGEMENT MODES Various modes exist to meet code and applicationbased expectations. Saving Energy Mode When the room is determined to be unoccupied, the temperature set points are changed to 5 F (adjustable) and controlled loads are turned off Comfort Mode When the room is determined to be occupied, the temperature set points return to the guest s previous settings or a predetermined setting depending on how long the room was unoccupied During setup, the thermostat can be programmed to turn controlled loads on when occupancy occurs or allow them to remain turned off Balcony Door Mode For rooms with a balcony, the door/window sensor can be used to control the thermostat settings Through programming, an open balcony door can change the thermostat mode to off or move the temperature set points When the balcony door is closed, the room will return to occupied mode HVAC SYSTEM TYPES There are five relays to support most HVAC systems. This includes thermostat applications with 1 or 2 stage conventional, heatpump including multistage, 2-pipe, 4-pipe, and multiple fan speeds. The RC5 does not have batteries and instead features power stealing support where a common wire can be used. Applications without a common wire may require a 3A-2 Thermostat Power Supply Module. Installation Notes For ease of installation, all thermostat connections are in the back base, with the front interface simply snapping to the base via high quality push connectors. FEATURES & BENEFITS Provides Energy Management for hotel rooms by adjusting temperature set points after accurately determining if a room is unoccupied Meets Title 24 and ASHRAE 9.1 21 standards Provides wireless load control turning loads off when a room is unoccupied and on when occupied State-Of-The-Art logic combines door activity with occupancy sensors to accurately determine if a room is occupied or vacant Compatible with nearly all thermostat applications including 2 and 4 pipe systems Quick installation software allows rooms to be replicated quickly and easily via a USB connector Reliable wireless technology Sensor battery life exceeds 5 years. FIELD-OF-VIEW TOP VIEW (in feet) 3 3 SIDE VIEW (in feet) 5 4 Major Motion, IR Minor Motion, IR 15

2-STAGE CONVENTIONAL HOT Common Cool Stage 1 (Y1) Heat Stage 1 (W1) Heat Stage 2 (W2) Cool Stage 2 (Y2) (RC) POWER UP FOR TEST OR CONFIGURATION HOT Common (RC) HEAT PUMP (2 STAGE HEAT/1STAGE COOL) HOT (RC) Common Reversing Valve (O/B) Compressor (Y1) Auxilirary Heat (AUX) Stage 2 (G2) CONNECTIONS FOR HEAT AND COOL S APPLIES TO ALL SYSTEMS HEAT Heat HOT Common COOL (RH) Cool HOT (RC)

SINGLE STAGE HEAT/COOL TWO SPEED HEAT PUMP Cool Heat Stage 1 Stage 2 Stage 3 HOT (RC) Common* (Y1) (W1) (G1) (G3) (G2) HOT (RC) Common Reversing Valve (O/B) Compressor Stage 1(Y1) Auxilirary Heat (AUX) Compressor Stage 2(Y2) 2-PIPE HOT (RC) Common Cool/Heat Valve (Y1) Stage 3 (G3) Stage 2 (G2) 4-PIPE HOT (RC) Common Cool Valve (Y1) Heat Valve (W1) Stage 3 (G3) Stage 2 (G2)

ELECTRICAL Line Voltage Power Consumption Operational Frequency Load Rating ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity OTHER Dimensions Agency Standards and Compliance Warranty Information ORDERING INFORMATION DESCRIPTION 24 VAC Omnistat3 Hospitality Thermostat ACCESSORIES DESCRIPTION 2 Amp max 5/6 Hz 2 Amp max total C to 4 C (32 F to 14 F) -1 C to 6 C (14 F to 14 F) % to 9% non-condensing 4.4in x 3.1in x.8in (112mm x 8mm x 21mm) Meets requirements for Title 24 213 and ASHRAE 9.1, cetlus, CE, C-Tick Two-Year Limited Warranty Lumina RF Wireless Ceiling Mount PIR Occupancy Sensors - Coverage of up to 45 sq/ft Lumina RF Wireless Ceiling Mount PIR Occupancy Sensors - Coverage of up to 1,5 sq/ft Lumina RF Wireless Corner Mount Motion Sensor Lumina RF Wireless Door / Window / Balcony Sensor Lumina RF 3 Amp Load Control Module - 96-25VAC (5/6 Hz) Lumina RF Plug-in Appliance Module - 12VAC 15A Lumina RF Wall Switch - 12-277VAC 1A Lumina RF Wall Switch - 12-277VAC 1A, No Neutral Hardwired Hospitality Key Card Switch - 24V Key Switch Interface * HKSWP ships with a Color Change Kit includes a White, Ivory and Light Almond faceplate. CAT. NO. RC5-2EW CAT. NO. ZSC4-INW ZSC15-INW LURMD-W LURDW-W 73A-3ZB 89A-1ZB ZSS1-NZ ZSS1-GZ HKSWP-Lx* SAT-178