An overview of the main proposals in BS th Edition. Electrical Contractors Association

Similar documents
Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Amendment Number 3 of BS how it might affect you

BS Outcomes 6

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

Special Types of Installation

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

INTERNATIONAL STANDARD

WR-E - Practical Electrical Wiring Standards - IEE BS Edition+A12011 Edition

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

BS : Amd Introduction

Requirements for Electrical Installations

INTERNATIONAL STANDARD

Guide to: 17 th Edition Consumer Units

INTERNATIONAL STANDARD

Requirements for Electrical Installations

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

User Information Sheet 008 : 2010

Requirements for Electrical Installations

Periodic inspection reporting - recommendation codes for domestic and similar electrical installations

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Australian/New Zealand Standard

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

INTERNATIONAL STANDARD

Stationary and Portable Spas Important Safety Information

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

SANS :2012 Edition 1.8

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Guide to the Wiring Regulations

IES PREPARATION COURSE FOR PPE PART2 EXAM ELECTRICAL ENGINEERING CP5 on Wiring Regulations and Low Voltage Design Calculations

Guide to sollysta Wiring Accessories

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Complete the table to show which size fuse, 3 A or 13 A, should be fitted to each of the appliances. Appliance Power Fuse

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

INTERNATIONAL STANDARD

Training, Assessment, Consultants for Hazardous & Industrial Areas

CE Marking and Technical Standardisation

Course outline: 442 Capstone G105A UEENEEG105A - Verify compliance and functionality of low voltage general electrical installations

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

WIRING MATTERS High protective conductor currents. 17th Edition Launched Requirements for Bathrooms

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Consumer unit replacement in domestic and similar premises

Designed & Manufactured by... A Guide to RCDs & Electrical Safety....Anything else is a compromise

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Guide to Condition Reports for Domestic Electrical Installations

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

A BITESIZED GUIDE TO AFDDs AND FIRE PROTECTION

NZECP 19: 1994 ISSN COVER PAGE

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Electrical Tech Note 107

Underfloor Heating Mat Installation Manual

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

REA 105 Arc Protection Module. Operator s Manual

AS/NZS IEC :2013

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

Australian/New Zealand Standard

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

Fixed Electrical Instillation Inspection

TOM BURNS, PLANNING DIRECTOR

Underfloor Heating Cable Installation Manual

CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Hair dryer User's manual

All Clear: How a UPS operates to clear faults

Consumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671

Installation, Operating and Maintenance Manual

Alberta Municipal Affairs

Electrical Safety Policy

AS/NZS 3190:2011 AS/NZS

Chapter 1 General... 5

CIRCUIT BREAKER FAIL PROTECTION

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

INSTALLATION & USER INSTRUCTIONS

Tempest TP420/180 Electric Pressure Washer

EDA Scottish Section Regional Business Forum

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Neil Hewitt Electrical & Air Conditioning P/L

NZECP 12:1993 ISSN COVER PAGE

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CMS CMS. Template cutout size: 187mm CEILING MONITOR SYSTEMS INSTALLATION MANUAL

Transcription:

An overview of the main proposals in BS 7671 17 th Edition Electrical Contractors Association

Why have Regulations Behold the electrician standing there. Soot, soil & verdigris defile his greasy hair. Shall such a being perish in it s youth? Alas it is indeed the dreadful truth. A moments lapse,a hands imprudent slip A flash! A crash! A sound like Zip! A smell of burning fills the startled air. The electrician is no-longer there!!

History 1882 first edition of the Wiring Regulations Remained as IEE domain until 1981 when they were aligned to some degree with IEC Wiring Regulations 1992 Became a BS formalising harmonisation 2008 BS 7671:2008 Requirements for Electrical Installations IEE Wiring Regulations 17 th Edition

What are the drivers for the proposed changes EU Harmonisation (CENELEC) Whole document has been revised to align with either CENELEC or IEC corresponding documents Very little national text remains

Parent Documents IEC 60364 CENELEC 60384 BS 7671

ECA Involved with development of BS7671:2008 ECA Technical Committee involved ECA Technical staff member chairs a sub-panel of BS 7671 committee ECA member comments were submitted on the draft New ECA book due early 2008, written by Darrell Locke Chairman of panel D of BS 7671 Will provide a unique insight and solutions not available in other publications Available from January 2008

When is the proposed new standard expected to be introduced Published January 2008 From January 2008 to July 2008 either 16th or 17th editions can be used All installations designed after 1 July 2008 to comply to BS 7671 17th edition

Outline BS 7671 17 TH Edition 2008 is laid out similar to BS 7671 16 TH Edition. The standard is divided into Parts and Chapters with appendices at the end as before. There are 7 parts as before Important changes to terminology and definitions Changes to Chapter 41 Protection against electric shock Harmonisation of bathrooms 701 More stringent EMC requirements New section Lighting & Luminaires 7 new Special Locations added 7 new Appendices

Part 1: Scope, Object & Fundamental Principles. Section 131 4 new regulations for protection of persons & livestock against voltage disturbances and electromagnetic influences 132.13 specific requirement for appropriate documentation. For a domestic or similar, a schedule could suffice 134.1.1 good workmanship by competent persons or persons under their supervision and proper materials 134.2.1Inspection & testing to be carried out by competent person

Part 1: Scope, Object & Fundamental Principles. 134.2.2 Designer of installation responsible for specifying the interval to the first periodic inspection. 135.1 Now makes a positive recommendation that every electrical installation is subject to periodic and testing, in accordance with Chapter 62

Part 2: Definitions There are approximately 260 definitions,there were approximately 170 in the 16 th edition. New ones include: Competent person A person who possesses sufficient technical knowledge and experience for the nature of the electrical work undertaken and is able at all times to prevent danger, and where appropriate,injury to themselves and others.

Part 2: Definitions Verification Inspection Testing Reporting All of above terms, whilst generally well understood are now defined for the purpose of the 17 th Edition Exposed conductive part, A conductive part of equipment which can be touched and which is not live but which can become live when basic insulation fails Example metal switch plates

Part 2: Definitions Extraneous conductive part, and its associated definition, remain unchanged Line conductor ( replaces phase conductor Line is the internationally used term ) Do not confuse Line conductor with Live conductor which can be a Neutral conductor

Part 3: Assessment of General Characteristics Section 332 new regulations on EMC requirements (may be the subject of amendment no 1 to BS 7671:2008) Two new chapters. Chapter 35 Safety Services & Chapter 36 Continuity of Service

Chapter 41 Direct contact protection now referred to as basic protection ( that is protection under normal conditions ) Indirect contact protection now referred to as fault protection ( that is protection under fault conditions)

Chapter 41 RCD s are now recognised as giving additional protection (this term is now used instead of supplementary protection ) RCD now required for all general use socket outlets rated up to 20A. Allows for 2 exceptions 1. Socket outlet used under supervision of skilled or instructed persons. 2. Socket outlet suitably identified for connection of particular item of equipment. To be recognised as giving additional protection The RCD must be rated at 30mA or less and operate within 40 ms when tested at 5 x rated operating current.

Chapter 41 Revised Disconnection times TN systems 0.4 seconds (final circuits up to 32A) TT systems 0.2 seconds (final circuits up to 32A allows for 0.4s where all Protective bonding in place and disconnection is achieved by overcurrent device) Distribution circuits and circuits not covered by table 41.1, TN= 5 seconds & TT =1 second Supplementary bonding can be used were Disconnection times can not be met

Tables 41 Maximum earth fault loop impedances tables 41B1 (fuses 0.4),41B2 (Circuit Breakers) and 41D (fuses 5 secs) now replaced by tables 41.2,41.3 and 41.4. The values between the old and new tables are now different the new tables values being slightly lower base on a nominal Uo voltage of 230 rather than previously Uoc open circuit voltage at the distribution transformer Example in the current table 41B2 the maximum Zs values for a 32A type B MCB was 1.5 ohms in the new table 41.3 the value is now 1.44 ohms No longer a ref to table 41 C

Chapter 52 Selection and erection of wiring systems Additional requirements for cables concealed in partition/wall at a depth of less than 50mm. RCD protection (30mA or less) now required for these cables where installation (premises) is not intended to be under supervision of skilled or instructed person and traditional protection can not be provided (earthed metallic covering, earthed metallic conduit or equivalent protection from nails, screws, etc) PVC/PVC cables concealed in walls in domestic installation at depth less than 50mm will need to be in safe zone and have additional RCD protection Where wall has any metallic construction RCD required irrespective of depth of cable.

Chapter 52 Selection and erection of wiring systems Chapter 52 now includes reference to busbar trunking systems and powertrack systems Max value of Voltage drop in consumers installations has changed - Table in appendix 12 Volts drop between origin and load terminals in LV system to be less than; Public Supply lighting 3% Other uses 5% Private Supply lighting 6% Other uses 8% These replace the current 4% requirement

Chapter 55. Luminaires & Lighting 559 36 new regulations Maximum circuit rating 16A for B15 B22 E14 or E40 lamp holders Through wiring only permitted where light is designed for this

Chapter 55. Luminaires & Lighting 559 559 applies to selection & erection of luminaires & lighting installations in fixed installations and highway power supplies & street furniture. Outdoor lighting includes: roads.,parks,car parks,gardens,sporting areas, monuments,floodlighting,telephone kiosks,bus shelters,advertising panels,road signs & road traffic signals. Excludes, distributors equipment & temporary festoon lighting.

Chapter 56 :Safety Services Chapter covers basic selection & erection aspects of supplies for safety services. Many overlaps with other standards & specifications ie: UPS and generators BS 5266: Emergency Lighting & BS5839: Fire Alarms Requirements removed from BS 7671

Part 6 & 7 Part 6 will be Inspection and testing Previously Part 7 Part 7 will be Special Installations or Locations previously Part 6

Part 6 New Part 6 Inspection and testing Table 71 A now known as table 61 Minimum installation values changed to 0.5 MΩ Selv or Pelv at 250 volts 1.0 MΩ for systems up to and including 500 volts with a test voltage of 500 volts. For systems above 500 volts tested at 1000 volts the minimum is also 1.0 MΩ

Chapter 62:Periodic Inspection & Testing 621.5 Periodic Inspection & Testing shall be undertaken by a skilled person,competent in such work. Proof of competence may be required

Part 7 Part 7 Special Installations or Locations This Part has now be greatly expanded to include 14 sections which include items on Marinas and similar locations Exhibitions.shows and stands Solar photovoltaic (pv) power supply systems Mobile or transportable units Electrical Installations in caravans and Motor caravans Temporary electrical installations for structures,amusement devices and booths at fairgrounds,amusement parks and circuses Floor and Ceiling heating systems

Section 701: Bathrooms Section 7 Special Installations or Locations Section 701 Locations,containing a bath or shower Zone 3 has been removed Suitable equipment can be within 600mm of a bath Excluding 13 amp sockets to BS 1363 which must be 3M from edge of bath or shower. All circuits to be RCD protected Supplementary bonding is not required provided any required Protective Equipotential bonding has been installed

Part 7 Numbering. The numbering system of BS 7671:2008 reflects the numbering of IEC and CENELEC documents generally, making it easier to find the source of a regulation. In Sections 7 the numbering reflects a change, addition or alteration to a previous regulation. Eg 701.415.2 modifies Regulation 415.2 (supplementary equipotential bonding) in relation to section 701 ie Locations containing a bath or Shower.

Section 702: Swimming Pools Zones A,B & C replaced with, Zones 0,1 and 2 Scope now includes basins of fountains

Section 703: Rooms & Cabins containing Sauna Heaters Zones, A,B,C & D replaced with: Zones 1,2 & 3

Section 704: Construction & Demolition Sites Section 705: Agriculture & Horticulture In both sections the reduced disconnection times of 0.2s and 25v equation have been removed

Section 708: Caravan & Camping Parks. Socket outlets must be provided individually with overcurrent and RCD protection for each pitch outlet. Previously 1 RCD was allowed to protect not more than 3 pitch outlets.

Appendices Changes to Appendix 4. Cable installation methods have new reference designations eg method 1 now method A1. Grouping factors changed,including grouping for underground cables New diagrams and more installation methods included

Appendix 6 Changes reflect changes of terminology throughout the regulations. Certificates in BS 7671 are model certificates.

New Appendices Appendix 8:Bus-bar current rating & volt drop Appendix 9:Definitions Multiple source, D.C and other systems Appendix 10:Conductors in parallel against overcurrents Appendix 11:Harmonic currents on balanced 3ph systems Appendix 12:Volt drop in general Appendix 13:Insulation resistance of floors and walls Appendix 14:Loop impedance

EMC Requirement for installation to meet emissions and immunity levels Revised EMC Directive reinforces this Dedicated BS 7671 section was not ready but may appear in amendment No 1 In meantime follow best practice, earthing, separation distances etc

Training Courses ECA will be offering the following options For ECS Gold Card Holders an Assessment only option. A 1 day update course covering the changes from 16 th to 17 th Editions with m/c assessment for those who hold a qualification based on BS 7671 obtained since 2001. A 3 day course covering the whole of BS 7671 for people who are electrically qualified and require an in-depth overview of the new wiring regulations, or anyone who has not obtained a formal electrical qualification since 2001.

The chief danger of electricity is ignorance A gentleman called Hilaire Belloc made the following point during the life time of the first wiring regulations in 1882 which is as relevant today as it was then; Lord Finchley tried to mend the electric light. It struck him dead and serve him right! For tis the duty of the wealthy man, to give employment to the artisan Fully competent to BS 7671:2008 of course!!