Flame Simulator User Manual. Publication Rev. A

Similar documents
Flame Rod Manual. Publication Rev A

Design Manual Installation Operation Maintenance

Model TL104 MANTL104. Test Lamp for Flame Detection

Testing Emission Source ITES Operating Manual OM

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

T3/E3 Fiber Optic Line Drivers

Installation Instruction Manual ILS-S

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

MaxLite LED Vapor Tight Linear Fixture

NLC C61 Air-Cooled Argon-ion Laser

RK / RK Methane Detector Operator s Manual

NLC 210 Air-Cooled Argon-ion Laser

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

MaxLite LED Round Pendant Highbay Series

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Dual Laser InfraRed (IR) Thermometer

MBCE-110/230UV Flame Sensor Module

100 Ft. LASER DISTANCE METER

RK/ RK Combustible Gas Detector Operator s Manual

SAFEVIEW-MINI2 TRANSILLUMINATOR

Motorised Infrared Optical Beam Smoke Detector. User Guide

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

FIREYE C9707A ALL FUEL SCANNER

Eclipse 90 UV Scanner Model A Version 1

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Multipurpose test lamp kit

alerting transmitter user guide other resources online at

Motion Sensor. Specifications

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

RK / RK CO 2 Detector Operator s Manual

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Motorised Infrared Optical Beam Smoke Detector. User Guide

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

PURPOSE OF THE PROCEDURE

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

User manual UV Flash Dry C1

Carbon Dioxide Sample-Draw Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual

North Dakota State University Laser Safety

Test Lamp for 210 series flame detectors Non EX

RK-05 Carbon Monoxide Detector Operator s Manual

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Distributed By: M&M Control Service, INC

GAS MONITOR Model Model

High Temperature InfraRed Thermometer with Laser Pointer

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

AUR300C. Advanced Ultraviolet Burner Controller

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Pressurized Filter Up to 1250 gallons

IWASAKI ELECTRIC CO., LTD

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Dallas Floor Standing Fireplace

COMBUSTIBLE GAS LEAK DETECTOR PEN

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

WARNING FIRE OR EXPLOSION HAZARD.

EQUIPMENT OPERATION MANUAL. Loctite High Intensity Ultraviolet Source

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

FlameHawk ATEX / IEC Ex Model

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Model OEM-2 INSTRUCTIONS FOR USE

SECTION GAS-FIRED RADIANT HEATERS

WARNING FIRE OR EXPLOSION HAZARD.

ANTIBACTERIAL HAND VAC WITH UV LIGHT

FIREYE FLAME SCANNERS

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

LEARNING SPECIAL HAZARD DETECTION TYPES

Electronic Circuit Controller

UV/IR Flame Simulator Model FS-1200

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Instruction Manual WARNING

Controllers. Instruction Manual WARNING

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Ottawa Retro style floor standing electric fireplace

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

CATALOGUE LASER POINTERS

Flame Simulator: FS-UVIR-975. User Manual

USER S INFORMATION MANUAL

Emery County Senior Center Green River 06/07

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

RK/ RK Oxygen Detector Operator s Manual

Gas Detection System SGAES-TG Operating Manual R01

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

RK Hydrogen Sulfide Transmitter Operator s Manual

UV-C Sanitizing System USER MANUAL Purifying Wand (EPLPW)

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

BlueWave MX-150 LED Spot-Curing System High-Intensity Curing System with the Flexibility of Multiple Systems

Transcription:

Flame Simulator User Manual Publication

Introduction This manual contains information for the Flame Simulator from Forney Corporation, 16479 Dallas Parkway, Suite 600, Addison, Texas. www.forneycorp.com All personnel should become thoroughly familiar with the contents of this manual before attempting to use the Forney Flame Simulator. Because it is virtually impossible to cover every situation that might occur during operation and maintenance of the equipment described in this publication, personnel are expected to use good engineering judgment when confronted with situations that are not specifically mentioned herein. Proprietary Notice The contents of this publication are proprietary data of Forney Corporation. Forney reserves all proprietary rights to this document, including all design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are expressly granted to others. Revision Date Comments A 10/28/2016 Initial Release i

Table of Contents Section 1 Description... 3 Section 2 Specifications... 4 Section 3 Safety... 5 Section 4 Installation and Operation... 5 4.1 IR Flame Detectors... 6 4.2 UV Flame Detectors... 6 4.3 Troubleshooting... 6 Section 5 Storage... 7 Section 6 Spare Parts... 7 6.1 Recommended Spare Parts... 7 ii

Section 1 Description Forney Flame Simulator is designed to help quickly test Forney s Flame Detector line of products. The Flame Simulator (FS-01) emits UV and IR light to approximately replicate radiations from a typical burner or igniter flame. The FS-01 has a tungsten filament lamp to emit visible to infrared light spectrum. The IR light intensity can be adjusted using the IR Intensity knob of the FS-01 (See Figure 1). The UV light is produced by a fixed intensity LED emitting UV light at 280 nm wavelength. No adjustment of the UV intensity is provided. Light beams from the IR lamp and UV LED pass through a motor driven chopper wheel to replicate flickering light out of a typical burner flame. The flicker frequency of the light beam can be varied by changing the motor speed using the Frequency knob of the FS-01 (See Figure 1). The Flame Simulator is powered using a wall mounted power pack which is rated for 90-264 VAC at 50/60 Hz and delivers 0.19A (max) output current and 10.0 W power. The device may be powered using any equivalent battery pack with a matching power plug connector. Figure 1 Forney Flame Simulator Controls 3

Section 2 Specifications Physical Environmental Power Pack Light Beams Compliance Dimensions: Weight: Operating Temperature: Storage Temperature: Cooling Operating Humidity Storage Humidity Input Voltage: Input Frequency Input Current Protection Output Voltage: Output Current Output Power: Approvals: UV Light IR Light Frequency RoHS 4.72 x 2.36 x 3.54 in (120 x 60 x 90 mm) 0.6 lbs. (275 grams) 0 C to 50 C (32 F to 122 F) 0 C to 50 C (32 F to 122 F) Convection 20 80% RH 10 90% RH AC 90 264VAC 50 60Hz 0.19A Max Internal Primary Current Use Inrush Limiting 6.0 VDC 1.5 A 10.0 W UL, CE Ultraviolet 280 nm Visible to IR Adjustable chopper wheel speed 4

Section 3 Safety Safety is the responsibility of each individual who installs, operates, or maintains Forney equipment. Forney Flame Simulator is not designed for use in hazardous locations. Direct exposure to potentially explosive gases and/or substances must be avoided. Caution: UV Light This device includes an ultraviolet LED. During operation, the LED emits high intensity ultraviolet (UV) light, which is harmful to skin and eyes. UV light is hazardous to skin and may cause cancer. Avoid exposure to UV light when LED is operational. Precautions must be taken to avoid looking directly at the UV light without the use of UV light protective glasses. Section 4 Operation Two types of detectors can be tested using the Flame Simulator IR and UV. Please refer to Forney s Flame Detector manuals for detailed information on how to set up and test each. In general, the Flame Simulator will aid the user by providing a light source that can be varied to test the detector s flame off / flame on capability. The Flame Simulator is not calibrated and is not capable to provide a specific output level. As such it is only useful to provide a relative source of light to indicate overall functionality. Figure 2 Flame Simulator Set-up 5

4.1 IR Flame Detectors 1. Place the Forney Flame Simulator approximately 5 to 15 inches away from the flame detector under test. 2. Refer to the instruction manual of the flame detector under test to set parameters appropriate for the target burner flame. 3. Vary either intensity or frequency of the light beam or both in the Forney Flame Simulator using their respective knobs. The flame intensity signal of flame detector should vary in response to these variations. 4. Verify flame relay pick-up / drop-out function of the flame detector under test by varying intensity & frequency of the light beam from the Forney Flame Simulator. 4.2 UV Flame Detectors 1. Place the Forney Flame Simulator approximately 5 to 15 inches away from the flame detector under test. 2. Refer to the instruction manual of the flame detector under test to set parameters appropriate for the target burner flame. 3. Vary frequency of the light beam in the Forney Flame Simulator using the Frequency knob. Intensity of the UV light beam is fixed and can be changed only by moving the Forney Flame Simulator closer or farther away from the flame detector under test. The flame intensity signal should vary in response to these variations on a fully functional flame detector. 4. Verify flame relay pick-up / drop-out function of the flame detector under test by varying the frequency of the beam from the Forney Flame Simulator by adjusting the Frequency knob. 4.3 Troubleshooting If the assembly malfunctions, refer to Table 1 for troubleshooting information. Table 1 Troubleshooting Symptom Probable Cause Remedy Unit fails to turn on. 1. Input voltage low 1. Provide correct supply voltage. 2. Power supply failure 2. Replace power supply UV LED does not turn on. 1. Damaged LED Driver diode 1. Replace unit. 2. Defective UV LED 2. Replace UV LED IR Light does not come on. 1. Lose connection 2. Bulb is burned out. Replace IR light bulb Light does not flicker. Chopper wheel not moving Replace motor. 6

Note: The UV LED and IR Light bulb have approximately 500 hours operating life. Do not keep the Flame Simulator powered when not in use. Section 5 Storage Store the Flame Simulator in a clean, dry environment. When possible, store the Flame Simulator in its original shipping container when not in use. Section 6 RMA / Warranty Forney Corporation warrants this product to be free of defective material and workmanship. Forney will replace this equipment as long as it is being used for its intended use and is found to be defective upon receipt up to the expiration of the warranty period. Prior to returning any material to Forney, please contact your Forney customer service representative and provide the contract number or the customer purchase order number. Section 7 Spare Parts When ordering spare parts, contact Forney s Aftermarket Department via any one of the following methods and furnish the following information. E-mail Phone Fax spares@forneycorp.com 972-458-6100 or 972-458-6142 or 1-800-356-7740 (24-hour direct line) 972-458-6600 7.1 Recommended Spare Parts The following spare parts are available from Forney. Table 2 Recommended Spare Parts List Part Description Part Number UV LED 92615-02 IR Light Bulb 92615-03 Power Pack 92615-07 Motor 92615-04 7