C22 Bulletin # October 1993 Supersedes May 1993

Similar documents
C22FC Bulletin # October 1993 Supersedes May 1993

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

MERIT SERIES Up Flow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

T P A 120 S 4 S N 1 Y

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

CB X 32 mv

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

8+* Bulletin No November 1997

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Visit us at For the latest technical information,

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

14 AC x

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

T S A 048 S 4 N 4 1 T

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

GSR21Q PULSE21 SERIES

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

INSTALLATION INSTRUCTIONS

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T P A 048 S 4 N 4 1 T

INSTALLATION INSTRUCTIONS

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

CHA to 17.6 kw (2 to 5 Ton) Bulletin # October 1994 Supersedes October 1990 ENGINEERING DATA. CHA16 Basic Unit. CHA16H-261 Basic Unit

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

CBX32MV (HFC-410A) SERIES UNITS

G34M Bulletin #69/ August 2003

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

NEW CUTAWAY POSITION ONLY

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

INDOOR COILS INDOOR COILS. Airflow Capacities 400 to 2,250 CFM [188.8 to L/s] FORM NO. C REV. 14 Supersedes Form No. C Rev.

Upflow/Downflow A-Coil Specifications

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

MERIT SERIES Downflow

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

13 GEP A L P - 1 A

MODELS B1PA024, 030 AND 036

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

EAC ELITE ELECTRONIC AIR CLEANER INDOOR AIR QUALITY ENGINEERING DATA FEATURES

ELITE Series Variable Capacity

ELITE Series R-410A - Two-Stage Compressor

KCC Centrifugal Fan Air Cooled Condensers

ELITE SERIES Downflow - High Efficiency Blower Motor

Installation Instructions

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

RGE 13 A T - 1 A

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION AIR COILS

TECHNICAL SPECIFICATIONS

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

2 shp 13 lc 1 36 t - 1 a

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Performance and Reliability. CB*, C* and TA* Models

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Installation Instructions

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SKYPAK II Heating & Cooling Self Contained Packages

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

Vertical Upflow Horizontal Left Air Handlers

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

INSTALLATION INSTRUCTIONS

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Cooling/Heat Pump Convertible Air Handlers

SECTION AIR HANDLING UNIT

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

Corp L2 Revised

Cooling/Heat Pump Convertible Air Handlers

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

SKYPAK II, 3 Ton Series, gives you a

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Transcription:

ENGINEERING DATA H C22 SERIES EVAPORATOR UNITS UP-FLO AIR-CONDITIONING AND HEAT PUMP *12,100 to 73,000 Btuh (3.5 to 21.4 kw) Cooling Capacity *ARI Standard 210/240 Certified Ratings with Matching Outdoor Unit COILS BLOWER COILS C22 Bulletin #210001 October 1993 Supersedes May 1993 Typical Applications Closet Installation With Pulse21 Furnace and Electronic Air Cleaner Utility Room Installation With G20E Whisperheat Furnace and Humidifier The maple leaf symbol in this bulletin denotes Canadian only usage where applicable NOTE Specifications, Ratings and Dimensions subject to change without notice. Applications Lennox designed and built up-flo evaporator coils can easily be installed with most Lennox up-flo furnaces. Coils match most plenum openings of Lennox furnaces. See Coil to Furnace Selector in this bulletin for more information. See condensing units bulletins (section Cooling Units Condensing Units) for evaporator unit applications and cooling capacities. See heat pump outdoor unit bulletins (section Heat Pumps Matched Remote Systems) for indoor coil applications and cooling and heating capacities. See FM21 bulletin in Heat Pumps Matched Remote Systems for more information. Construction Lennox designed and fabricated coils are constructed of precisely spaced ripple-edged enhanced aluminum fins machine fitted to rifled copper tubes. Lanced fins allow for maximum exposure of fin surface to air stream. Copper rifled tubing construction provides long coil life and ease of service. Rifled tubing provides superior refrigerant flow resulting in maximum heat transfer. Twin coils assembled in an A configuration provides extra large surface and contact area for maximum efficiency. Fins have collars that grip tubing for maximum contact area resulting in excellent heat transfer. Flared shoulder tubing joints and silver soldering provide tight leakproof joints. Coils are thoroughly tested under pressure to insure leakproof construction. Drainpan is constructed of a non-corrosive polymer and has dual 3/4 inch (19 mm) fpt drain connections. Two-piece end panel allows easy access for coil servicing and cleaning. Refrigerant lines are equipped with sweat connections on both suction (vapor) and liquid line. Fully Tested Evaporator units have been thoroughly tested with matching condensing and heat pump units in the Lennox Research Laboratory environmental test room. Air resistance data is from tests conducted in the Lennox air test chamber. Coil assemblies are shipped factory assembled and ready for installation. Check and Expansion Valve Kit Furnished Check and expansion valve is factory installed on all models. Adjustable Coil Adaptor Base Furnished Adjustable adaptor base is furnished with coils to provide quick and easy installation in a wide variety of applications. See Coil to Furnace Selector, dimension drawings and application drawings. CF30-00 Non-Adjustable Adaptor Base (Optional) Fixed width base (46J43) is available for C22 installations with G20E-Q5/6-150 model furnaces. See Specifications table, Coil to Furnace Selector, dimension drawings and application drawings. Full Height Empty Coil Cabinet Cabinet (Optional) Cabinets are fully insulated with thick fiberglass insulation and are constructed of heavy gauge steel with a deluxe baked-on enamel paint finish. Bend-up flanges are provided in outlet opening of cabinet for ease of plenum connection in conventional. See Specifications tables, Empty Coil Cabinet to Furnace Selector and dimension drawing. Up-Flo Coil Twinning Kit (Optional) Twinning kit LB-65597A (30J76) is available to operate two C22-41, C22-46 or C22-65 coils simultaneously with one HS17 condensing unit and two furnaces. Kit contains necessary plumbing fittings to interconnect coils. Must be ordered extra. 1993 Lennox Industries Inc.

SPECIFICATIONS Model No. C22-21-TXV C22-26-TXV C22-26W-TXV C22-31-TXV C22-31W-TXV Net face area sq. ft. (m 2 ) 3.11 (0.29) 4.0 (0.37) 4.0 (0.37) 4.0 (0.37) 4.0 (0.37) Evaporator Coil Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) No. of rows 2 2 2 3 3 Fins per inch (m) 15 (590)3 15 (590) 15 (590) 12 (472) 12 (472) Suction (vapor) line connection in. (mm) sweat 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 3/4 (19) 3/4 (19) Liquid line connection in. (mm) sweat 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Condensate drain (fpt) in. (mm) (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 Refrigerant HCFC-22 HCFC-22 HCFC-22 HCFC-22 HCFC-22 Coil shipping weight lbs. (kg) 1 package 31 (14) 32 (15) 36 (16) 42 (19) 46 (21) *Expansion Device Furnished Check and Expansion Valve Full Height Empty Coil Cabinet (Optional) Catalog No. 98H79 98H80 98H81 98H80 98H81 Ship Wt. lbs. (kg) 8 (4) 10 (5) 14 (6) 10 (5) 14 (6) *Furnished and factory installed. SPECIFICATIONS Model No. C22-41-TXV C22-46-TXV C22-51-TXV C22-65-TXV Net face area sq. ft. (m 2 ) 4.44 (0.41) 6.71 (0.62) 7.58 (0.70) 7.58 (0.70) Evaporator Coil Tube diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) No. of rows 3 2 2 3 Fins per inch (m) 12 (472) 15 (590) 15 (590) 12 (472) Suction (vapor) line connection in. (mm) sweat 3/4 (19) 7/8 (22.2) 7/8 (22.2) 1-1/8 (28.6) Liquid line connection in. (mm) sweat 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Condensate drain (fpt) in. (mm) (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 Refrigerant HCFC-22 HCFC-22 HCFC-22 HCFC-22 Coil shipping weight lbs. (kg) 1 package 43 (20) 50 (23) 51 (23) 62 (28) *Expansion Device Furnished Check and Expansion Valve Non-Adjustable Coil Adaptor Base (Optional) - - - - CF30-00 (46J43) Full Height Empty Coil Cabinet (Optional) Catalog No. 98H82 98H83 98H84 98H84 Ship Wt. lbs. (kg) 22 (10) 26 (12) 32 (15) 32 (15) Coil Twinning Kit (Optional) LB-65597A (30J76) - - - - LB-65597A (30J76) *Furnished and factory installed. 2

AIR RESISTANCE Air Volume Total Resistance Model No. cfm L/s in. w.g. Pa 300 140.03 7 Model No. Air Volume Total Resistance cfm L/s in. w.g. Pa 1000 470.07 17 C22-21 C22-26 C22-26W C22-31 C22-31W 400 190.05 12 600 285.10 25 700 330.13 32 400 190.04 10 600 285.08 20 800 380.13 32 1000 470.20 50 1200 570.27 67 600 285.09 22 800 380.16 40 1000 470.24 60 1200 570.34 85 1400 660.44 109 800 380.10 25 1000 470.15 37 C22-41 1200 570.21 52 1400 660.28 70 1600 760.36 90 1200 570.10 25 1400 660.13 32 C22-46 1600 760.17 42 1800 850.21 52 2000 940.25 62 2200 1040.30 75 1200 570.09 22 1400 660.12 30 1600 760.15 37 C22-51 1800 850.19 47 2000 940.23 57 2200 1040.27 67 1600 760.15 37 1800 850.18 45 C22-65 2000 940.22 55 2200 1040.26 65 2400 1130.31 77 DIMENSIONS inches (mm) ADJUSTABLE ADAPTOR BASE (Furnished With C22 Coil) 2-3/4 (70) 14-7/8 (378) to 24-7/8 (632) 9-3/8 (238) to 19-3/8 (492) Opening 2-3/4 (70) 1 (25) 19-3/4 (502) 17-3/4 (451) Opening 1 (25) 3/4 FRONT VIEW (19) SIDE VIEW ADAPTOR STOP (3 stops for standard coil widths) ADAPTOR DETAIL Tab Frame Telescopes To Accommodate Various Furnace Opening Tab may be bent up 90 for centering of smaller coils. 3

COIL AND ADAPTOR BASE APPLICATIONS C22-21, C22-26(W), C22-31(W) AND C22-41 COILS C22-46, C22-51 AND C22-65 COILS PLENUM PLENUM COIL COIL ADJUSTABLE ADAPTOR BASE ADJUSTABLE ADAPTOR BASE FURNACE FURNACE ACCESSORY DIMENSIONS inches (mm) CF30-00 ADAPTOR BASE (46J43) For G20Q5/6E-150 Only NOTE Adaptor base is not required with empty coil cabinet. 4

DIMENSIONS inches (mm) C22-21, C22-26, C22-26W, C22-31, C22-31W AND C22-41 COILS 1-3/4 (44) SUCTION (Vapor) LINE 3-3/8 (86) 1-3/8 (35) LIQUID LINE 1-1/8 (29) B 3-1/8 (79) 4-1/4 (108) AIR FLOW OPENING C A FRONT VIEW 3/4 (19) CONDENSATE DRAINS 2-3/4 (70) 15-7/8 (403) OPENING 19-3/4 (502) SIDE VIEW 1-1/8 (29) Model No. A B C in. mm in. mm in. mm C22-21 14-3/4 375 15 381 10 254 C22-26 14-3/4 375 18-3/4 476 10 254 C22-26W 19-3/4 502 19 483 15 381 C22-31 14-3/4 375 19 483 10 254 C22-31W 19-3/4 502 19 483 15 381 C22-41 19-3/4 502 21 533 15 381 C22-46, C22-51 AND C22-65 COILS 23-5/8 (600) C22-46 26-1/2 (673) C22-51 AIR FLOW LIQUID LINE 3-3/8 (86) 26-3/4 (679) C22-65 SUCTION (Vapor) LINE 1-3/4 (44) 1 (25) 1-1/8 (29) 4-1/4 (108) 3-1/8 (79) 1-1/8 (29) 21 OPENING (533) 24-7/8 (632) FRONT VIEW 2-3/4 (70) 3/4 (19) CONDENSATE DRAINS 14-3/4 OPENING (375) 19-3/4 (502) SIDE VIEW 5

ADJUSTABLE COIL ADAPTOR BASE TO FURNACE SELECTOR Furnace Model No. G20E G20X Coil Model Number C22-21 C22-26 C22-26W C22-31 C22-31W C22-41 C22-46 C22-51 C22-65 Q2-50 Q3-50 X Q2-75 Q3-75 X Q4-75 Q3/4-100 Q5/6-100 Q3/4-125 G20E Q5/6-150 *CF30-00 *CF30-00 *CF30-00 Q3-40 Q3-60 Q4-60 G21 Q3-80 Q4-80 Q5-80 Q3-100 Q4/5-100 V3-60 G21 V3-80 V5-80 V5-100 Q3-50 X Q2/3-75 X G23 Q3-100 Q4/5-100 2-45 2-60 3-60 2-75 3-75 G24M 4-75 X X 3/4-100 X X 4/5-100 X X X 3/4-120 X X 4/5-120 X X X 4/5-140 Q3-50 X Q3-75 G26 Q3/4-100 Q4/5-100 Q2-70 O20 Q3-105/120 X Q5-140/154 X X X X Q3-105/120 X Q3-105/120R X OF20 Q5-140/154 X X X X Q5-140/154R X X X X Q5-175/210R X X X -245 X Coil matches furnace and air volume. Coil matches furnace physically. Check furnace air volume and total system pressure drop for satisfactory match with coil. X Coil matches air volume. Coil does not match furnace physically and requires field fabricated transition. X Coil does not match furnace physically and requires field fabricated transition. Check furnace air volume and total system pressure drop for satisfactory match with coil. Does not Match *Coil matches furnace with optional CF30-00 adaptor base (46J43). 6

ACCESSORY DIMENSIONS inches (mm) UP-FLO EMPTY COIL CABINETS NOTE Empty coil cabinet is equipped with a 5/8 inch (16mm) flange that may be bent up 90 for plenum connection on conventional up-flo furnace applications or to help in alignment with B24 Series Blower Units. *Dimensions before flange is bent up. **Dimensions after flange is bent up. *1-5/8 (41) *1-5/8 (41) *C *1-5/8 (41) *16-1/2 (419) OPENING *2 (51) TOP VIEW 20-1/8 (511) A 1-1/2 1-1/8 **17-5/8 (448) **D 1-1/8 (38) (29) Opening (29) Opening 1 (25) B AIR FLOW FILTER RAILS FILTER ACCESS PANEL 3/4 (19) Opening 3/8 (10) 19 Opening E (483) 3/4 A (19) 20-1/8 (511) FRONT VIEW SIDE VIEW Filter Rails are furnished with B24 Series Blower Units for field installation in empty coil cabinets. 3/4 (19) Empty pycabinet C22 Coil A B C D E Catalog No. Model No. in. mm in. mm in. mm in. mm in. mm 98H79 C22-21 16-1/4 413 17 432 13 330 14 356 14-3/4 375 98H80 98H81 C22-26 C22-31 C22-26W C22-31W 16-1/4 413 21 533 13 330 14 356 14-3/4 375 21-1/4 540 21 533 18 457 19 483 19-3/4 502 98H82 C22-41 21-1/4 540 25-3/4 654 18 457 19 483 19-3/4 502 98H83 C22-46 26-1/4 667 25-3/4 654 23 584 24 610 24-3/4 629 98H84 C22-51 C22-65 26-1/4 667 28-3/4 730 23 584 24 610 24-3/4 629 7

EMPTY COIL CABINET TO FURNACE SELECTOR Furnace Empty Cabinet 98H79 98H80 98H81 98H80 98H81 98H82 98H83 98H84 98H84 Model No. Coil Model No. C22-21 C22-26 C22-26W C22-31 C22-31W C22-41 C22-46 C22-51 C22-65 G20E G20X Q2-50 X X Q3-50 X X X X Q2-75 X X X Q3-75 X X X X Q4-75 X X X Q3/4-100 X X X X Q5/6-100 Q3/4-125 X X X G20E Q5/6-150 X X X Q3-40 X X X Q3-60 X X X Q4-60 X X X G21 Q3-80 X X X Q4-80 X X X Q5-80 Q3-100 X Q4/5-100 V3-60 X X X X X G21 V3-80 X X X X X V5-80 X X X V5-100 X X X Q3-50 X X X X Q2/3-75 X X X X G23 Q3-100 X X X Q4/5-100 X X X 2-45 X X 2-60 X X 3-60 X X X 2-75 X X 3-75 X X X G24M 4-75 X X X X X 3/4-100 X X X X 4/5-100 X X X 3/4-120 X X X X 4/5-120 X X X 4/5-140 X X X Q3-50 X X X X Q3-75 X X X G26 Q3/4-100 X X X Q4/5-100 X X X Q2-70 X X X X O20 Q3-105/120 X X X X Q5-140/154 X X X X Q3-105/120 X X X X X X Q3-105/120R X X X X X X OF20 Q5-140/154 X X X X Q5-140/154R X X X X Q5-175/210R X X X -245 X Coil matches furnace and air volume. Coil matches furnace physically. Check furnace air volume and total system pressure drop for satisfactory match with coil. X Coil matches air volume. Coil does not match furnace physically and requires field fabricated transition. X Coil does not match furnace physically and requires field fabricated transition. Check furnace air volume and total system pressure drop for satisfactory match with coil. Does not Match 8