Battery Fail Monitoring System

Similar documents
Operating Instructions. For. Alarm Control Module. Model SSR 500

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Public Safety DAS Annunciator Panel

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

AURATON 2005 / 2005 TX

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

1U ULTRA Compact System

PAC1500Xi PORTABLE APPLIANCE CHECKER

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

4100U City and Relay Cards Installation Instructions

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

TS40 Product Assembly & Service Information Manual

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Installing and operating your Cabinet Cooling System, with Digital Thermostat

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

EXTINGUISHING AGENT RELEASE MODULE

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

PO Box 827 Hawley, MN (218) Fax (218)

P4200PM / P5000PM Remote Air Dryer User s Guide

TECHNICAL DATA OBSOLETE

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

FEC400 Series. Installation Manual

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

RELEASE DEVICE CONTROLS

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

40KMC KMQ

03.03.mmm REV.2 09/01

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Table of Contents SECTION PAGE

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

ZSC100 Gas Detection and Alarm System Controller

4 & 8-POINT ANNUNCIATORS Instruction Manual

RW8CA 8-Inch Low Profile Powered Subwoofer. RW10CA 10-Inch Low Profile Powered Subwoofer. User's Manual

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Power Supply Display Module PSDM. Installation and Operation Manual

DIAGNOSTIC GUIDE DISPLAY FAULT/ERROR CODES E1 THERMISTOR OPEN IMPORTANT. Activating the Diagnostic Test Mode. Test Mode Functionality

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Getting Started Quick Reference Guide

40cm Pedestal Fan with Remote Control

HT-2 / 9600 Series Control Contents

EATON DFDAP-M / FDAP-M Remote Alarm Panels

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Installation and user manual for the BiWire / Conventional Repeater Panel

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

5000 INSTALLATION GUIDE

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Sierra Series 900 Single & Dual Channel System. Instruction Manual

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Installation and Operation Manual Low Power (LP) DC Power System

SERIES PSE-690 INSTALLATION & OPERATION MANUAL IMPORTANT: PSE-690 REMOTE STROBE POWER SUPPLY

Intelligent Security & Fire Ltd

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Universal Gas Detector

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

Operation & Maintenance Manual

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Installation & Troubleshooting Requirements

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

DIESEL Engine Fire Pump Controllers Features

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Model 17A00 Expansion Enclosure

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Parts and Service Manual

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Remote Chexit Module (RCM) System. General Information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Service: to SLK Laboratory Hot Plates glass made of ideas

INSTALLATION & OPERATION MANUAL

CR Series Command Relays

LC3000 Level Controller Installation and Maintenance Instructions

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Constant voltage 3-phase rectifier.

ISIS SAFETY SYSTEM Installation guide

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Transcription:

Battery Fail Monitoring System

Table of Contents 1 DOCUMENTATION 1.1 Introduction 2 GENERAL INFORMATION 2.1 Scope of the Manual 2.2 Product Description 3 DESCRIPTION OF FEATURES, ALARMS AND CONTROLS 3.1 Module Indicators 3.1.1 Module Power indicator 3.1.2 Low Voltage Fail 3.1.3 Battery Condition Fail 3.2 Fail Alarm 3.2.1 Fail Alarm Contact 3.3 Reset Button 3.4 Mid-Point Alarm Setting Control 3.5 Battery Mid-Point Voltage Contacts 3.6 Mounting 3.7 Universal Operation 4 INSTALLATION INSTRUCTIONS 4.1 Inspection 4.2 Preparation/Mounting 4.3 Alarm Connections 4.4 Module Installation and Removal 4.4.1 Installing Module 4.4.2 Removing Module 4.5 Initial Start-up 4.6 Normal Mode of Operation

1 DOCUMENTATION 1.1 Introduction Please read this manual thoroughly prior to use, in order to become familiar with the unit s numerous features and operating procedures. To obtain a maximum degree of safety, follow the prescribed sequences as outlined. This manual contains warnings and notes to the user. Points that are vital to the proper operation or safety of the operator are indicated by: WARNING. Points that are important to the performance, the equipment or ease of use are covered by a notation that is in bold italics. 2 GENERAL INFORMATION 2.1 Scope of the Manual This instruction manual covers the installation and operation of the Wing Guard Battery Fail Monitoring System. The topics covered include product specifications, features, installation and operation. 2.2 Product Description The Wing Guard Battery Fail Monitoring System (Figure 1) is designed to monitor the status of a single battery string. The method used is battery midpoint voltage monitoring. The Wing Guard connection to the battery string splits the battery string voltage in half at the midpoint (Figure 5 of the installation section). The string voltage halves are compared. When the difference between the two exceeds the programmed value (set by front panel rotary switches) then an alarm is sent to the customer s office monitoring system via the contacts on relay 1. The status indicator (red LED) is flashing and requires manual intervention to reset (front panel push button).

FIGURE 1 FRONT VIEW OF WING GUARD A complete battery monitoring system consists of one or more Wing Guard modules installed on a Din-rail. See Figure 2. Additional Wing Guard modules can be added later, after the system has been installed (e.g. when additional battery strings are added). FIGURE 2 BACK VIEW OF WING GUARD

3 DESCRIPTION OF FEATURES, ALARMS AND CONTROLS The following section will cover the various features and options available on the Wing Guard Battery Fail Monitor. 3.1 Module Indicators There are three indicators on the Wing Guard module to provide visual indication of its operational status (see Figure 1). The conditions and associated colours are: Module Power On Green Low Voltage Fail Green flash Battery Condition Fail Red 3.1.1 Module Power indicator The LED indicator lights up when the Wing Guard module is getting power from the battery and the status is OK. 3.1.2 Low Voltage Fail The LED indicator flashes when there is a Low Voltage Fail. 3.1.3 Battery Condition Fail The LED indicator will turn to RED when the battery is in fail condition. 3.2 Fail Alarm The Wing Guard Battery Fail Monitoring System module is equipped with two fail alarms which are extended to an alarm module (customer s monitoring system) via the contacts on one of the two Form C relays (see installation section of this manual). The alarm can indicate one of the following conditions:

If the voltage drops to 52,5 Volt, If the battery cell is open, If there is a bad connection, If the cell is performing inefficiently, If the battery cell is shorted. 3.2.1 Fail Alarm Contact The Wing Guard module has a terminal block for the Form C relay alarms located on the top of the module; both normal open and normal close contacts are available. The Low Voltage Fail alarm contacts will change state when the voltage drops to 52,5 Volt. The Battery Condition Fail alarm contacts will change state when the voltage difference between the two halves monitored exceeds the programmed value, set by the front panel control. NOTE: The NC contact for the Fail Alarms closes during an alarm condition. 3.3 Reset Button The local alarm indicator is flashing (red LED or green flashes). You must press the Wing Guard front panel push button to reset. 3.3.1 Automatic reset When the alarms are solved, the Wing Guard will reset automatically when there is a connection between 4 and 5 on top of the Wing Guard module. 3.4 Mid-Point Alarm Setting Control 4 front panel rotary switches (Figure 1) with 10 indents allows the user to set the maximum allowable voltage deviation in battery string halves to 1 mvolt up to 9999 mvolt. 0 8 2 (Steps in 1 mvolts) 6 4

3.5 Battery Mid-Point Voltage Contacts On top of the Wing Guard there is an open connecting to be used by the customer (See also Fail Alarm Contacts). This is a design equipped with screw terminals, same as for the battery terminals (in addition to the Fail Alarm contacts described above). 3.7 Mounting Universal mounting by Din-rail standard, makes mounting of the Wing Guard very easy. 3.8 Universal Operation The Wing Guard obtains power directly from the battery for universal 48 Volt operation. The module is internally fused and diode protected from damage in case reverse polarity connection is made. 4 INSTALLATION INSTRUCTIONS This section is provided for qualified personnel to install and interconnect the Wing Guard battery fail monitoring system. 4.1 Inspection Unpack the unit and inspect the exterior. If any damage is observed, contact the carrier immediately. Continue the inspection for internal damage. In the unlikely event of internal damage, please inform the carrier and contact Wetac for advice on the impact of the damage. 4.2 Preparation/Mounting The Wing Guard Battery Fail Monitor has been designed for mounting on a standard din-rail. The unit must be mounted in a clean and dry environment.

4.3 Alarm Connections Insert each wire into the appropriate terminal on the terminal block (Figure 3) and secure the wires by tightening the terminal with the terminal screw. See specifications section of this manual for recommended wire sizes. WARNING: Do not over tighten the terminal screws. This can result in damage to the input connectors. The Fail Alarm terminals are connected to the relay contacts from the Wing Guard module and both normal open or normal close contacts are provided. NOTE: The Fail Alarm relay is de-energized during alarm conditions. 4.4 Module Installation and Removal Warning: Leave cables disconnected from battery and verify polarity using a voltmeter. Make battery connections only after all other wiring is completed. Warning: HIGH VOLTAGE AND SHOCK HAZARD. Only qualified personnel familiar with line and battery voltage should attempt to change modules while the Wing Guard Battery Fail Monitor is energized. Remove rings, watches and other jewellery before performing this procedure. Keep fingers clear of live electric parts while unit is energized. 4.4.1 Installing Module Battery sense leads should be bundled from the module to the battery. Insert each wire into the appropriate terminal on the terminal block and secure the wires by tightening the terminal screws. See specifications section of this manual for recommended wire sizes. WARNING: Do not over tighten the terminal screws. This may result in damage to the input connectors. The terminal block can be plugged in to the Wing Guard module.

4.4.2 Removing Module Unplug the two cable connectors from the front of the module. Detach the module from the din-rail. 4.5 Initial Start-up After completing the system wiring and installation, perform the following start-up and test procedure to ensure proper operation. Confirm that the battery sense leads and alarm cables are connected to the terminal of the correct polarity at the Wing Guard module. See TB (terminal block) in Figure 4. LOAD + - + - + - + - SENSE +VB 1 2 3 4 5 6 7 8 -VB FIGURE 4 SHOWING WING GUARD TERMINAL TO BATTERY CONNECTIONS WARNING: Check battery polarity. Failure to do so could damage the unit and/or battery. Verify the battery installation according to the instructions provided by the battery manufacturer. Measure total battery string voltage and the midpoint voltage. Push the learn button for 5 seconds, the green led will flash.

Set the midpoint monitor to the desired voltage deviation setting, which should be greater than the midpoint voltage differential under normal operating conditions. 500 mv is recommended. Test the module by pushing the test button. (The module will test all functions and alarms) 4.6 Normal Mode of Operation Normal operation of the battery fail monitoring system will be indicated by the illumination of the status led indicator by green. When the voltage drops to 52,5 Volt the status led will flash green. (LOW VOLTAGE FAIL) An open cell, shorted cell or poor performing cell will cause the midpoint voltage deviation to shift exceeding the midpoint voltage setting. This will result in a battery midpoint alarm indicated by the illumination of the status led indicator by red. (battery fail) NOTE: Some fine tuning may be required to obtain the ideal setting that is sensitive enough to detect a bad cell and will not produce false alarms. The midpoint voltage setting will have to be adjusted within the functional range and is dependant upon many factors including the battery characteristics under float, charge and discharge conditions.