Industrial fire alarm systems

Similar documents
Industrial Fire Detection

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

HOTSPOT

HOTSPOT-1000 HOTSPOT Thermographic Surface Temperature Detector. Installation - Operation - Maintenance EN11

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

HOTSPOT. Industrial-suited parametrizable Infrared heat detectors with integrated signal processing and evaluation

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

55 years of know how on flame monitoring systems from Leipzig

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

UniVario Industrial Fire Detectors Versatile in Application

COMPACT FLAME CONTROLLER CFC 1000

PYROsmart. The intelligent infrared early fire detection and extinguishing system

COMPACT FLAME CONTROLLER CFC 2000

Gas Sensor Fire Detector GSME-Ex

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

Ex Products Highest level of safety under the most difficult conditions

Fire Detection systems. UniVario industrial fire detectors for every job

CONSTANT FILL LEVEL MONITORING AT COVESTRO AG

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Talentum - Why use our Flame Detectors?

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

INDUSTRIAL AIR CURTAIN. IndAC 2

MHD 535. General functions and specific requirements

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

On the job around the clock 24/7: Fire detection systems

Dräger PIR 7200 Toxic Gas Detection Transmitter

DCS DSS OSS EIB OBPS OPTS FDS AFSS

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

CO warning instruments and gas spillage detectors

Dräger REGARD -1 Control System

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Dräger X-am 7000 Multi-Gas Detection

Recalibrate the way you look at gas detection

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER

Flame Monitors BROCHURE

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Dräger Polytron Pulsar 2 Open Path Gas Detector

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

LEARNING SPECIAL HAZARD DETECTION TYPES

Products and performance

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

Your competent partner for measuring and services.

SIHI dry Dry running vacuum pumps

Dräger X-am 2500 Multi-Gas Detection

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

designed for rail 5000 Series

Dräger X-am 5000 Multi-Gas Detection

Linear Heat Detection for Coal Conveyors. Application Guide

talentum Flame detection across the spectrum Range Brochure

OpenStage M3 Family Reliable, seamless connectivity in any environment

KEMPER ThermoSystem. For further information on KTS use the QR code!

Coal Pile Fire Monitoring System

Automated Infrared Thermography Complete Solutions from a Single Source

Laser Level Measurement Products. Introducing the New LLT100

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS. Superior Detection Capabilities. Maximum Configurability

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

AUTOMATIC FIRE SUPPRESSION SYSTEMS

AVA The expert for. conditioning

Coal Control. Belt Rip Detection System Type BPS-A1 and BEPROS-S1. Gesellschaft für Automation mbh. Technical changes reserved.

INDUSTRIAL AIR CURTAIN. IndAC 2

Conspec - Why use our Flame Detectors

ADVANCED Series 15P1 17P2 19P2

Dräger REGARD -1 Control System

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Condition monitoring using FAG products. Technical Product Information

Top Notch Geared Motors for Energy Efficient Heating Systems Drives for Biomass Heating Systems

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Danfoss gas detection unit Type GD Heavy Duty

Gas Temperature Measurements with High Temporal Resolution

D-VTA 100-XX BROCHURE

Dräger X-am 5000 Multi-Gas Detection

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

EN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy

Fire Detection Systems Product Catalogue (Version )

Smart Fire Prevention

Industrial Metal Detectors

Early Fire Detection and Automatic Extinguishing in Waste-to-Energy Power Plants and Waste Treatment Plants

IRD INFRARED ROTARY DRUM HEATING. DRYING. CRYSTALLIZING. COATING.

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Dräger X-am 2500 Multi-Gas Detector

Dräger Flame 5000 Flame Detection

Dräger Flame 5000 Flame Detection

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

Solutions for internal vessel cleaning

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

Lamp Supply (Recommended)

Transcription:

Industrial fire alarm systems

Industrial fire alarm systems redefined. While fire alarm systems for standard applications, e.g. in offices and residential buildings, provide an enormous variety of solutions, industrial systems often give conventional fire detectors insoluble problems. 20 years ago, GTE Industrieelektronik GmbH had already accepted the new challenges of fire detection in an industrial environment and developed the Advanced Discovery System (ADICOS). Unfavourable environmental conditions, such as dust and moisture, can cause false alarms or even damage and failures. The system comprises a series of detectors for reliable and interference-sensitive fire detection in industrial plants. Typical At the same time, the risk of fire in industrial plants is often extremely high. And false alarms can also cause enormous costs if they cause a plant to come to an unnecessary standstill. applications include power stations, recycling plants, steel companies, mills, silos, storage, transport and processing facilities for coal, wood chips, biomass, secondary fuels, etc. Power Plants Steelworks Recycling Conveyors Processing Storage

Product overview - detectors GSME-M4 GSMEs are fire gas detectors with four integrated semiconductor gas sensors. The GSME sensors are fully parameterisable meaning that their control and monitoring can be adapted to nearly all types of environment. Due to their innovative sintered metal filter technology, the detectors are protected from any penetration by dust and dirt. However, the gases to be detected can pass unimpeded diffuse through the filter barrier. GSME-X22 On the basis of a self-test, together with the manufacturer's declaration provided by GTE, the type GSME-X22 detectors are approved for use in the potentially explosive dust atmospheres of zone 22. Ex-works, they are equipped with permanently installed hose water protection. The connecting cable is also permanently screwed onto the detector. GSME-X20 The type GSME-X20 detectors have also been certified and type-tested by a notified body as per ATEX directives, as well as in accordance with the requirements issued by IECEx. They are therefore approved for the use in the potentially explosive dust atmospheres of zones 20 to 22. The GSME-X20 models replace all variants of the preceding GSME-Ex model.

TPME HOTSPOT-X0 HOTSPOT-X20 HOTSPOT-X22 The TPME offers the possibility to integrate the operating temperatures of critical parts of the plant into the monitoring function of the Advanced Discovery System. The TPME sensor elements are simply screwed together with the part of the plant to be monitored (e.g. drive, bearing, etc.) and the alarm thresholds are pre-set. The HOTSPOT-X series is designed and approved for the use in potentially explosive areas. HOTSPOT-1000 The ADICOS HOTSPOT is an intelligent thermal camera. It allows the optical detection of pockets of embers and overheated parts of the plant. Using a resolution of 1000 heat-sensitive pixels, the whole range of visibility of the detector can be parameterised with alarm criterions and, in this way, it can be adapted to almost any environment. The HOTSPOT-X0 is the first IR-fire detector approved for a potentially explosive gas atmosphere of zone 0 to 2. The HOTSPOT-X20 and the HOTSPOT-X22 are used in potentially explosive dust atmospheres. The detectors are type-tested by a notified body as per ATEX directive and IECEx.

GSME-M4 The new generation of fire gas detectors GSME Fire Gas Detectors are the spearhead of the Advanced Discovery System. They can already detect open and hidden smouldering fires within their initial phase. The new generation of the GSME-M4 comprises four parameterisable semiconductor gas sensors that are used for monitoring and evaluating the concentration and behaviour of fire-indicating commissioning. This incorporates the usual on-site exhaust pollution in the evaluation process of the internal detector measurements. A service PC provides the possibility to call up sensor data of each detector via the ADICOS M-bus using the PC software ADICOS Manager and to display it separately. It is also possible to specify the parameters at any time. gases by applying the multi-criteria method. Their robust design protects them against damage due to dust, dirt, and moisture. Considering the air flow conditions, GSMEs can be used in nearly all internal plant area. For instance, they are outstandingly suitable for use along cased conveyor belt lines, within storage bunkers, or in the head area of silos. By means of the multi-criteria evaluation, any interference caused by the natural outgassing of conveyed materials or exhaust gas from mine trucks can intentionally be suppressed. For this purpose, an emission spectrum is first recorded during the GSME-M4 Gas sensors: CO H 2 HC NO x The new hardware platform with four semiconductor gas sensors replaces all former GSME variants. Four basic parameter sets are available ex-works: Standard, extended, robust, and individual. GSME-M4 detectors are generally equipped with an integrated device heating feature that can be switched on to prevent condensation. Unlike the former GSME variants, hose water protection can be retrofitted at any time.

GSME-X20 Fire gas detector for ex-zone 20 to 22 In many industrial plants, specific areas are subject to the ATEX directive 1999/92/EC. Within these areas where there is a risk of explosion, electrical devices are only allowed to be operated with the respective approval. This also applies to fire alarm systems. For type-tested variant, as per ATEX directive 2014/34/EU and IECEx. The GSME-X20 offers the same functionality as a standard GSME-M4, however it is approved for use in the potentially explosive dust atmospheres of zones 20 to 22. this reason, GTE also offers the GSME detectors as a

GSME-X22 Fire gas detector for ex-zone 22 We are offering the fire gas detector GSME-X22 as an economic compromise solution between the GSME- M4 without explosion protection approval and the type-tested GSME-X20. On the basis of a self-test, together with the manufacturer's declaration, this detector is approved in the potentially explosive dust atmospheres of zone 22.

HOTSPOT-1000 Intelligent thermographic cameras The ADICOS HOTSPOT is an IR-fire detector with infrared-measuring devices and intelligent signal evaluation for the fast detection of all kinds of smouldering fires, also within their initial phase. The integrated thermal imaging detector comprises lines for moving pockets of embers. Furthermore, overheated drives, shaft bearings or rollers can also be detected. The HOTSPOT can be used in addition to the fire gas detectors GSME above, as well as within silos for monitoring the bulk material stored. more than 1,000 heat-sensitive pixels whose alarm thresholds can be freely parameterised. In this way, the HOTSPOT can be optimally adapted for the respective application environment and the detection target to be fulfilled. Its robust design, as well as its standardised, integrated seal air connection, protects the HOTSPOT from dust, dirt and moisture. In addition to the infrared sensor, each HOTSPOT includes a conventional camera for alignment and orientation. For easy assembly The short response time of 100 milliseconds allows the monitoring of conveyor belts or other conveyor in the desired angular position, a robust mounting foot with ball joint is available. HOTSPOT-1000 Resolution: 32 x 31 Viewing angle: 53 x 52

HOTSPOT-X0 The thermographic camera for ex-zones 0 to 2 The HOTSPOT-X0 is the first IR-fire detector that has been approved worldwide for the potentially explosive gas atmospheres of zones 0 to 2. The innovative thermal camera allows for early fire detection in chemical parks and gas-fired power stations, as well as in all other areas in which potentially explosive gas atmospheres can occur. flames and supports several alarm zones by means of independent alarm parameters - this ensures the best possible adaptation of the detectors to the particular application. Its compact design allows its use also within confined spaces. HOTSPOT-X0 thermal cameras can directly be integrated in the fire alarm bus of entral fire alarm systems. The Hotspot-X0 detects excess temperatures and

HOTSPOT-X20 / -X22 Thermographic cameras for ex-zones 20 to 22 The IR-fire detector HOTSPOT-X20 and HOTSPOT- X22 are for use in the potentially explosive dust atmospheres. The detectors are type-tested by a notified body as per ATEX directive and IECEx. The HOTSPOT-X20 has a resolution of 1000 heatsensitive pixels and an integrated seal air connection that protects the optical system of the Instead of a conventional camera, the standard design of the HOTSPOT-X20 is equipped with a flange for frontflush assembly on casings of any kind. The HOTSPOT-X22 is an economic intermediate variant for use in the potentially explosive dust atmospheres of zone 22. The design of the HOTSPOT-X22 is based on the HOTSPOT-1000 and offers the same range of functions. detector from contamination.

TPME The parameterisable temperature warning device The temperature warning device, TPME, is a valuable complement to the GSME and HOTSPOT in the field of fire detection in the industrial environment. It facilitates the easy integration of the punctual and linear monitoring of temperatures in the Advanced TPMEs are used in all places where other alarm technologies cannot be used economically due to poor environmental conditions and where the primary detection target is defined as the recognition of overheated parts of the plant. Its temperature contact sensors, up to three pieces, can be placed anywhere and allow the direct monitoring of individual parts of the plant, such as motors, gear units, or bearings even when they are difficult to access. Due to separate alarm and pre-alarm thresholds, any potential damage to the plant can be detected and avoided during the initiation phase. Discovery System. TPME-3 Sensor elements: 3x point-shaped

Systems technology System and connection technology The Advanced Discovery System is based on a user-friendly field bus, the ADICOS M-bus, that allows you to bring together data communication and power supply for all types of devices in one cable. The easy assembly and expansion possibilities make this system very attractive. We are offering the following additional components: Central fire alarm system BMZ 30 The central fire alarm system BMZ30 is a compact central unit that communicates with all ADICOS warning devices via the M-bus and displays and evaluates their statuses. It allows the grouping of detectors and the establishment of alarm rules. From there, multiple alarms can be sent in accordance with the pre-set parameters and control devices can be activated. In combination with a service PC, it also ensures the uninterrupted recording of all system events. Besides a modular extension through an Ethernet interface, the ADICOS BMZ can also interface with other well-known central fire alarm systems, e.g. from Bosch and Siemens. M-BUSMASTER XF S The M-bus is a master-slave bus system. In addition to the detectors that work as slaves, it needs a master unit, the M-BUSMASTER. It is not only able to supply a small number of detectors with the required operating voltage, but it also controls the whole data communication network. Furthermore, it allows access to a service PC via an RS232 interface. The M-BUSMASTER XF can manage the communications with up to 250 detectors. In doing so, due to its protective class IP 65, the M-BUSMASTER XF is especially suitable for unfavourable environments and can be further extended by an Ethernet module. The M-BUSMASTER S is a practical tool for service works.

POWER SUPPLY UNIT NT V40-A3 If the power output of the M-BUSMASTER is not enough for supplying all the connected detectors, an additional external power supply unit will be required. The short-circuit-proof NT V40-A3 supplies a maximum current of 3 A at 40 V. COM-MODULES For integrating the ADICOS detectors into an existing fire protection system, various extension modules are available. So, for example. the GSME, HOTSPOT and TPME can be connected, to central fire alarm systems fromsiemens and Bosch using these plug-in boards. GSME HOSE WATER PROTECTION To increase the protection of the GSME-M4 from moisture, retrofitting the stainless steel, GSME hose water protection system is available. Connection and junction box AAB AAB-L/-XL AAB-X22 The AAB connection and junction box allows the easy installation of the ADI- COS detectors. All supply and data lines can be branched through this from the main line to the respective detectors. Due to the ergonomic design of the terminal strips and the pre-printed designations, quick and faultless wiring is ensured. The stainless steel variants AAB-L and AAB-XL provide additional wiring variations. The AAB- X22 is approved for ex-zone 22. Connecting cable Because all variants of ADICOS detectors are equipped with an industrial bayonet coupling, a ready-made standard cable can be used when installing the system. This shielded connecting cable is fitted on one side with the ADICOS bayonet plug and is available ex-works in different lengths.

Digital version: GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 D-41747 Viersen, Germany +49 (0) 2162 / 3703-0 +49 (0)2162 / 3703-25 info@gte.de www.adicos.de