The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

Similar documents
Applying the latest version of the National Ventilation Standard Heyoka Solutions, LLC Paul H. Raymer

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

Applying the latest version of the National Ventilation Standard Heyoka Solutions, LLC Paul H. Raymer

Dwelling Ventilation Strategies, Including ASHRAE 62.2 ASHRAE Ventilation for Acceptable Indoor Air Quality

Indoor Environmental Quality

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Mechanical Ventilation for Kansas Weatherization Programs

Ventilation BCBC 9.32 & Richard Kadulski Architect

Put the V back in HVAC

FV0511VQ1 (Fan Only) FV1115VQ1 (Fan Only) FV0511VQL1 (Fan/Light) FV1115VQL1 (Fan/Light) Yes Yes Yes Yes

Heat or Energy Recovery Ventilation System

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

Ventilation BCBC & Richard Kadulski Architect

FV-08VKML1, FV-08VKSL1, FV-08VKM1, FV-08VKS1, FV-08VKL1, FV-08VK1, FV-05VK1

Outside Air Requirements... SOLVED!

An Introduction to Energy Efficient and Effective Whole-House Ventilation

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Building Codes, Ventilation Rates, and Certified Performance. Ventilation Track Comfortech 2007 St Louis, MO September 27, 2007

USEFUL RESOURCES: Applicability. Item o of section 150. Review-Definitions Section 101

Residential Balanced Ventilation Systems

Lodging/Hotel. Panasonic Ventilation Fans

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

MECHANICAL VENTILATION STANDARDS V.1

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

Massachusetts Energy Code Technical Support Initiative

BEST PRACTICE RECOMMENDATIONS

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

EARTH ADVANTAGE HVAC REQUIREMENTS

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

IAQ VENTILATION SOLUTIONS

Inspection Checklist Residential Mechanical Rough In July 2016

IT S ABOUT TIME FOR FRESH AIR.

CERV Fan and Duct Sizing Information

Inspection Checklist Mechanical Final

Featuring Vent Lights and Premium Grilles

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Indoor Air Quality Product Brochure.

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

Ventilation Strategies in Weatherization

AirCycler g2-k Installation & User s Guide

Inspection Checklist Mechanical Rough in

IAQ VENTILATION SOLUTIONS

Practical and Effective Approaches to Residential Ventilation for Production Builders

Time-Based Scheduling of Residential Ventilation

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (6)

Installation Instructions

Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted.

Indoor Air Quality Product Brochure.

Ventilation Solutions IAQ Canada

Model 8120 and 8126 Safety & Installation Instructions

Uniform Dwelling Code 2017 Updates SPS 323

Light commercial models

Supplement A- Improving Forced Air Heating Systems

NEW HOME CERTIFICATION PROGRAM 2018 PROGRAM GUIDE

RESNET HERS Rater Sample Test Questions 2

BPI 1200 and ASHRAE Standards

Air Change, Ventilation, and Dehumidification for Multi-family Buildings

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (2)

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Ultra SERIES. We ve Revolutionized the Ventilation Fan

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

2015 MECHANICAL CODE REQUIREMENTS

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

Equipment Specifications and Required Information Quantity Rebate

Heat & Energy RECOVERY VENTILATORS

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

Ventilation Solutions IAQ Canada

MAD-AIR 2016 Mechanical Air Distribution and Interacting Relationships. John Tooley Advanced Energy (919)

LEED for Homes Points

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Bathroom Ventilation

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

TR Series - The Ultimate ERV

Mechanical Ventilation Checklists

ENERGY STAR Qualified Homes

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

Ventilation Solutions. Bathrooms

HVAC for Raters & Inspectors

WHOLE-HOUSE VENTILATION SYSTEMS

Ventilation and Indoor Air Quality

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Tech to Tech May 07 HRV s & ERV s

Ventilation Techniques. Topic 5 - Audio 53

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

MBPA Home Performance FIELD DATA COLLECTION FORM

Ventilation in Humid Climates: Data from Field Experiments

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

PA 500/1100V Ultra Quiet Ventilation Fan

EnergyMeasure HOME DATA COLLECTION FORM

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Transcription:

The 2018 Ventilation Extravaganza Rick Karg Residential Energy Dynamics 2018

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 2

Multifamily 3

Multifamily Buildings What s Different from Detached Units? Smaller dwelling units Connections to other units Cooking odors, smoking, etc. Less connection to outdoors Fewer options for ventilation Centralized systems Ventilation Space conditioning Non-residential spaces (corridors, etc.) 4

What MF does 62.2-2016 apply to? Anything MF building A duplex qualifies as multifamily A 50-story building qualifies 62.1 addresses non-residential spaces in multifamily buildings 5

MF Infiltration Credit Allows for an infiltration credit to be taken for horizontally-attached multifamily homes, which includes common walls, subject to a reduction factor. 6

Multifamily Infiltration Credit Implication: For the first time SOME multifamily units can get an infiltration credit. How it is calculated: Do a blower door test of the unit. Calculate the fraction of enclosure area (6-sides) that is NOT attached to other units or garages. Multiply infiltration estimate from blower door test by this fraction. Q fan = Q tot (Q inf * A ext ) A ext = exterior surface total envelope surface 7

Blower Door Tests in MF If there is no infiltration credit, is there any value to blower door tests in multifamily? Yes Helps identify leakage locations Helps evaluate air sealing implementation Can help identify pathways between units (IAQ) (compartmentalization) 8

62.2 MF Requirements Requirement for compartmentalization Suggested maximum leakage rate of 0.3 CFM 50 per ft 2 of enclosure area Note: enclosure area is 6 sides, not just floor area 9

Exhaust fans Multifamily Single in-line can serve multiple units Individual unit fans cannot share a duct Concerns about exhaust fans? Supply fans Single fan can serve multiple units if it is continuous or has a backdraft damper to prevent cross-contamination 10

Multifamily Ventilation Issues Concerns about exhaust fans? Contamination from adjacent units and corridors Compartmentalization issues If central exhaust system, use Constant Air Regulator (CAR) dampers. Challenging fan termination issues in MF Terminating outdoors Wall fans rather than ceiling fans? 11

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 12

Manufactured Homes The standard does cover manufactured homes No special requirements or compliance paths for mobile homes Common issues: Where to put the fan(s) Fitting a fan in a ceiling (often lowprofile fan is needed) or in a wall Depressurization caused by fan(s) 13

Panasonic WhisperFit Panasonic WhisperFit Low Profile 80 or 110 CFM 3 or 4 inch duct 10 ¼ x 10 ¼ x 5 5/8 0.8 or 1.5 sones 3.3 or 3.3 CFM/Watt at 0.1 static 24.5 or 33.5 Watts at 0.1 static 3-year warranty Models: FV-08VF2 or FV-11VF2 14

Panasonic WhisperWall 70 CFM 8 inch duct 10 1/8 grille size 1.1 sones 3.9 CFM/Watt at 0.1 static 18 Watts at 0.03 static Model: FV-08WQ1 15

NuTone LoProfile 80 CFM 3 or 4 inch duct 10 1/8 grille size 1.1 sones 3.9 CFM/Watt at 0.1 static 25.7 Watts at 0.1 static Ceiling or wall installation Model: LPN80 16

Depressurization Depressurization in a manufactured home must be addressed just as in a site-built dwelling. Often a more frequent issue in manufactured homes because of the smaller volume. 17

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 18

Equipment HVI testing: Home Ventilating Institute 920 Product Performance Certification Procedure Including Verification and Challenge HVI 915 Procedure for Loudness Rating of Residential Fan Products 19

Range hoods Exterior mounted fan 20

System Choices Exhaust fans Through wall Bath fans. Should be certified by HVI for both air flow and sound. Ceiling insert 21

System Choices Exhaust Only Panasonic Six WhisperGreen Select Base Models: FV-05-11VKSL: 130 to 110 CFM integrated multi-speed + LED Light FV-05-11VKL1: 50-80-110 CFM single speed + LED Light FV-05-11VKS1: 30 to 110 CFM integrated multi-speed FV-05-11VK1: 50-80-110 CFM single speed FV-11-15VK1: 110-130-150 CFM single speed FV-11-15VKL1: 110-130-150 CFM single speed + LED Light Customizable, all-in-one fan and fan/led light combinations Pick-A-Flow speed selector satisfies designed air flow Plug N Play technology provides up to three value added features Revolutionary DC motor with SmartFlow technology 22

System Choices Exhaust Only Broan/NuTone 110 CFM ULTRASense H, Humidity Sensing Technology fans react to a quick rise in humidity to turn the fan on; ULTRASilent Sound Technology less than 0.3 Sones; NuTone Ultra Series SB110HPower: 8.3 Watts 23

System Choices Exhaust Only Air King Model ESVD; 2 set up speeds; Low 30, 40, 50, 60,70,90,100, 120 High: 80, 110, 130, & 150 Optional 26w night light; Optional motion sensor; Optional humidity sensor; All airflow below 130 cfm < 0.3 sones 24

System Choices Exhaust Only Delta Breez CFM: 50 to 124 Sones < 0.3 Power: 5.6 to 20 watts Humidity control 25

System Choices Exhaust Only Fantech FQ80L Sones: 0.4 Power: 30 watts Light: 26/4 FQ80 Sones: < 0.3 Power: 25 watts 26

System Choices Exhaust Only Kitchen Range Exhaust Hoods Air King ECQ Continuous: 30, 50, 70, 90 CFM @ 0.3 sones High speed: 250 CFM @ 3.5 sones Fan power: 75 Watts, max. Light: 26 Watts Ducting: Horizontal or vertical Air King ECV Continuous: 30, 50, 70, 90 CFM @ 0.3 sones High speed: 250 CFM @ 3.5 sones Fan power: 75 Watts, max. Light: 26 Watts Ducting: Horizontal or vertical 27

Kitchen Exhaust Fan Broan QP330WW range hood with 100 CFM low speed (0.3 sones) and 450 CFM high speed (5 sones). 28

System Choices In-Line Fans 29

In-Line Exhaust Fans Photos courtesy of Wisconsin Weatherization Program 30

Supply-Only Dedicated Systems Supply air systems including duct connections and filters and flow regulators 31

Supply Ventilation to Furnace Return Air Ducts should be tight (or they can bring in bad air); Should have good motorized damper; Must be controlled to run even if no heat is needed; Furnace fan energy use can be high; Intake must be kept clean of yard debris and other outdoor stuff. 32

Supply Ventilation to Furnace Return Air Source: AirCycler, http://www.aircycler.com/pages/aircycler-frv 34

Outside air supplied to return side of the air handler Supply-Only Furnace Return Aldes CAR Constant Airflow Regulation AirCycler Field Controls Damper 34

Balanced Ventilation Exhaust and supply ventilation should have equal cfm. Balanced without recovery Heat Recovery Ventilator (HRV) unit transfers sensible heat only with no humidity transfer. Energy Recovery Ventilator (ERV) Unit transfers sensible heat and humidity. 35

HRV or ERV? For a small, tight house in a cold climate especially a house with a large family choose an HRV. For a large house in a cold climate especially a house with few occupants choose an ERV. In a hot, humid, climate, an ERV will cost a little less to operate during the summer than an HRV. In mixed climates, choose either appliance. Source: Green Building Advisor 2010 http://www.greenbuildingadvisor.com/blogs/dept/musings/hrv-or-erv. 36

Heat Recovery Ventilators (HRV) Venmar HRV, inside view 37

Heat Recovery Ventilators (HRV) Must be installed in an accessible place for service. Should be inside the conditioned space for maximum efficiency. 38

Single Room ERV by Panasonic WhisperComfort 40 CFM 39

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 40

62.2-2016 Controls Dwelling-Unit Ventilation Readily accessible manual ON-OFF control, including but not limited to a fan switch or a dedicated branchcircuit over-current device Allows for maintenance Controls shall include text or an icon indicating the system s function. 41

Controls Dwelling-Unit Ventilation Control alternatives: o Appropriately labeled o Readily accessible o Both of these controls require circuit breaker or system override to shut off. Honeywell will require reprogrammin g after shut down. Aircycler 42

Controls Dwelling-Unit Ventilation o Complies with 62.2-2016 o Appropriately labeled o Readily accessible o But if installed in an obvious place, is likely to be turned off. Source: Residential Ventilation Handbook, McGraw-Hill, Paul Raymer, 2009 43

Controls Dwelling-Unit Ventilation o Intermittent operation requires a timer or other automatic control o A new section in standard provides algorithm for real-time controllers 44

Controls Local Exhaust Ventilation Readily accessible manual ON-OFF control shall be provided for demandcontrolled devices. Control devices... are permissible provided they do not impede occupant control; Shut off timers; Occupancy sensors; Multiple speed fans; Combined switching; IAQ sensors. 45

Controls Local Exhaust Ventilation Standard wall switch Delay timer Crank timer Motion detector IAQ control Delay Timer IAQ Control Humidity Control Motion Detector 46

Controls Panasonic Tamarack Technologies, Inc. Fantech 47

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 48

Ductwork White, vinyl ducting don t use this stuff Rigid, galvanized ducting: crimped end should be pointed away from the fan White, pvc drain pipe smooth, long lengths 49

Ductwork The effects of duct length on airflow performance in more detail. Actual length is the actual, physical length of the duct run (how far is it from A to B); Equivalent length is equivalent resistance to the airflow generated by the fittings; Effective length is the sum of the Actual and Equivalent lengths. Actual length + Equivalent length = Effective length Source: Residential Ventilation Handbook, McGraw-Hill, Paul Raymer, 2009 50

Ductwork Example: 60 cfm fan installed in the ceiling. Duct will run for 2 feet before turning up through two 45º elbows running straight up 4 feet to the roof, connecting to a low profile roof cap with backdraft damper and bird screen. Two 45º elbows have an equivalent length of 10 feet (5 + 5 using metal elbows) Roof cap has an equivalent length of 60 feet. Actual flexible ducting = 12 feet (doubled 6 for flexible ducting) Effective length using flexible ducting and a metal elbow 12 + 60 + 10 = 82 feet. Raymer, Residential Ventilation Handbook 51

Ductwork Elbows, T s, Wyes, etc. are points of resistance; Joints that are factory made are tighter than joints that are made in the field. Seal the field joints first. HRV & ERV duct design is the same as designing and HVAC system. Raymer, Residential Ventilation Handbook 52

Ductwork Description 45 adjustable elbow, 2-piece Equivalent Length (Ft) for rigid ducting 5 90 adjustable elbow, 4-piece 10 Wye, equal sizes 10 Tee, take-off 50 Tapered increaser/reduc er Hard increaser/reduc er 4 8 From Residential Ventilation Handbook 53

Ductwork Description Triangular wall cap for round duct with backdraft damper & bird screen Triangular wall cap for round duct with bird screen, without backdraft damper Rounded wall cap for round duct with backdraft damper & bird screen Equivalent Length (Ft) 60 35 40 Louvered wall cap 40 Low profile soffit vent with backdraft damper and bird screen Roof cap, low-profile for round duct with backdraft damper & bird screen Roof cap, goose-neck, for round duct with backdraft damper & bird screen 60 60 35 From Residential Ventilation Handbook 54

Ducting Ducting must conform to the following table (5.3): Duct Type Flex Duct Smooth Duct Fan Rating 50 80 100 125 50 80 100 125 Diameter Maximum Length 3 X X X X 5 X X X 4 56 4 X X 114 31 10 X 5 NL 81 42 19 NL 152 91 51 6 NL NL 158 91 NL NL NL 168 7 & more NL NL NL NL NL NL NL NL Can t use 4 flex ducting for larger than 56 cfm 57

Ductwork Photos: Paul Raymer Water reduces the diameter of the duct; Air flowing across water creates waves, increasing the resistance. 56

Terminations Gone Wrong 57

Results of Bad Terminations Different attics 58

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 59

Local/Dwelling-Unit Combination Use high quality DC-motor fan to serve as local bathroom (or kitchen) ventilation and dwelling-unit ventilation (double-duty fan). Best if bathroom (kitchen) is centrally located. Bathroom door must remain open most of the time. Provide pressure relief for some communication when door is closed. Not best practice, but complies with 62.2-2016. 60

Broan Fan Upgrade Kit Use existing fan housing and avoid the high cost of an electrician, however alteration or control might require an Electrician (complies with local exhaust requirements only) 61

Add control If there is a decent existing fan on a wall switch, can add a control that runs the fan on a schedule without requiring a new fan Consider Age of existing fan Whether AC- or DC-powered fan 62

Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 63

Local Ventilation Install demand-controlled in full baths and kitchen, 50 and 100 CFM. If use occupancy sensor, beware of line of sight. In full bath, consider 80 CFM for purging room of shower moisture. Consider pressure across closed bathroom door. 3 pascals or less. Proper flow when bathroom door is closed. 64

Local Ventilation In kitchen, use a range hood with a high capture efficiency. 65

Other Local Ventilation Toilet rooms (not required by 62.2) 50 CFM demand-controlled fan. Consider other rooms with high potential contaminant sources. 66

Local Kitchen Ventilation This is not best practice! 67

Dwelling-Unit Ventilation First choice, balanced ventilation? Is dwelling tightness an issue? Life-cycle cost? As second choice, exhaust-only in cold climates, supply-only in warm climates. Do not use Alternative Compliance Path. Install so well mixed, central location. Do not combine with local fan, but if do... Install in central location. 68

Dwelling-Unit Ventilation Duct supply and exhaust air to/from appropriate locations: Supply to bedrooms and living areas Exhaust from bathrooms and other contaminant-producing areas. Use caution when exhausting from kitchen. No fans in basement if not lived in. 69

Controls for Dwelling-Unit Vent. Ensure controls have flash memory. Label controls. Use controls that are easy to install and setup. Use controls that are easy for homeowner. 70

Filtration If possible, install filter. Minimum MERV = 6 Better practice is MERV = 11 or higher Need to consider duct static pressure 71

Ductwork Minimize length and fittings. Minimize collection of internal condensate. Minimize external duct condensate. Use smooth material. Use proper diameter. Insulate duct outside of conditioned space. 72

Termination Always terminate outdoors. Don t terminate in soffit. Terminate in gable end or through roof. Use bird and insect screen. Utilize backdraft damper in system. 73

Health and Safety Consider source control of pollutants. CO alarm(s). Basement and crawlspace moisture. Consider pollutants from adjacent spaces. Encourage use of ventilation system. Combustion safety testing. 74

Fan Use and Maintenance User s manual When and how to operate. Maintenance schedule. When to service. Who to call. 75