PERMACONN PM1030 Includes DI300. Installation Manual

Similar documents
PERMACONN PM1048 v3 3G Install Manual Australia

T4000 Security Communicator

Fratech Multipath-IP

Fratech Multipath-IP STU

600 Range Dialer Installation Manual. Version 1.0

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Version 1.03 January-2002 USER S MANUAL

SC-F3G User Manual 1.0

GLOBAL. InstallatIon & operation manual

COMMUNICATOR ET08 / ET081

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

DigiAir QUICK GUIDE & INSTRUCTION MANUAL


IP & SMS Alarm Communicator

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

EVO192 v3.0 Fire and Burglary What s New

2000 Series. Program Entry Guide. Control Panels


BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

SMS8 Alarm Control Panel

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Summit 3208GLD USER MANUAL. Electronics Line

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

IC60 Sintony 60 Intrusion Control Panel

Contents. Glossary

Installation Manual. for D2300 DualCom GPRS

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

DigiPlus INSTRUCTION MANUAL

X64 Wireless Training

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

CC408. Quick Reference Guide Solution 880

BURGLAR ALARM PANEL BS-468

GradeShift G2r/G3r INSTallaTIoN MaNUal

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

rvm4c Installation Guide Remote Video Module

Kwêbeam GSM/Interface/Repeater Module

All-In-One Wireless Security System V1.0. Model #: MG-6060

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

CC488. Quick Reference Guide Solution Ultima 880

Сontrol panel Contact GSM-9N

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

TELGUARD TG-4 CDMA. Revised August 14, PROPRIETARY INFORMATION For use by TELGUARD customers only. Distribution to others strictly prohibited.

NESS 5000 SERIES DIALLER

Control/Communicator Installation Manual

Security System. User Guide for the LED Command Center

Power Wave Zone Alarm Panel V8.5. Installation Manual

GSM RFID VOICE Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

The future of security, secured IP by security professionals, for the professional security industry

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation Manual Premier 412/816/832. Issue 10

MK9 series CarePhone. Installers Mauual

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

DYGIZONE GJD910 Lighting Controller & Enunciator

Instructions manual. By-alarm. By-alarm Manager software

CHEAT SHEET: SPECTRA V2.1

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

AXI LED USER MANUAL (REV. 1.0)

BAT LTE SKU: IPD-BAT-LTE

AES IntelliTAP. Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device. Version Installation Guide CONTENTS

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

2G & 3G GSM Door Contact Alarm

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

IEI NETWORK INTERFACE MODEL TS2040

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Contact ID as of 2/2/2015

Watchguard WGAP864 User Manual

reading carefully this guide, operating this system strictly on the standard procedure.

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

BAT WIFI SKU: IPD-BAT--WIFI

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

System Introduction. 1.1 Specifications S E C T I O N 1

Transcription:

PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700

Introduction The PERMACONN system provides two-way communication between supervised premises and the monitoring centre. The Permaconn PM1030 is a versatile state of the art microprocessor based 3G and NextG security communicator. This unit can interface with a range of alarm panels using RS485 / RS232 and Contact ID. It also has four (4) Inputs and three (3) Outputs. The Permaconn PM1030 reports Contact ID events on the 3G networks. The Permaconn PM1030 polls according to the registered fault recognition time. The Permaconn PM1030 requires an interface module to communicate with an alarm panel. Features of the Permaconn PM1030 Four (4) Inputs and a dedicated box tamper Three (3) Outputs Contact ID interface (requires DI300 module) RS485 / RS232 Interface (requires IFM) IP reporting (requires IP63 Module) Monitors and reports status of alarm panel interface lead Monitors and reports battery status Monitors and reports DC power status Non volatile memory stores all setup information in the event of a power failure Dual Sim Cards No onsite programming required RF signal strength indicator Various LED status indicators for easy onsite diagnostics 13.8V battery charging circuit. 2

Installation Procedure Place the Permaconn PM1030 unit in the exact position where you intend to install it. Screw the antenna onto SMA connector. Unit is by default set up to operate with the DI300. If any other module is required remove the two (2) jumpers from (JP2) and fit applicable IFM. No additional module required for standalone operation. Connect 14.5V DC power to power up. The HEART BEAT LED will blink. The signal strength will be displayed as High, Medium or Low. The Online/GPOL LED will blink to indicate connectivity with the Permaconn Network. This may take to three (3) minutes. Connect the DI300 or IFM module. Program alarm panel. Generate an event from the alarm panel. The Online/GPOL LED will stay on steady. Test all inputs and outputs. Carry out all tests on Final Commissioning Check List Never leave site without achieving a steady Online/GPOL LED. Connecting the DI300 A Three (3) wire connection is required between the DI300 and the PM1030. Negative and A & B Data lines. Do not connect the red wire when using 14.5V DC plug pack. Power for the DI300 is supplied from the Alarm panel. The gray wire connects to Data line on keypad. The gray wire simply monitors and reports the status of the alarm panel. Cut the gray wire off at terminal if you do not use it, otherwise it will send false alarms. The COMMS LED will flash to indicate correct serial communication between the DI300 panel and the Permaconn PM1030. 3

Connecting the Alarm Panel Always use the original telephone lead supplied with the alarm panel between the alarm panel and the DI300. A four wire connection is required between the alarm panel and the DI-300 module. Ring & Tip as input and R1 & T1 as the return line. Always use 611 Tail plugged into the DI300 Connect PSTN in Mode 3. 4

Choosing GPRS or PSTN Primary Reporting Unit is supplied as GPRS primary with PSTN back up. To make the PSTN primary and GPRS back up, the PSTN jumper must be removed from the DI300. The option of PSTN primary should only be selected after installation and testing with GPRS as primary. If PSTN is primary you must test the following: Trigger the tamper input on the Permaconn PM1030 unit. Verify with the monitoring centre that a tamper was received with the correct CID account number Programming the Alarm Panel Panel must use tone dialling. Panel must be programmed with at least an 8 digit phone number. Panel must report Contact ID format. Panel must be programmed with a Hard ID. 5

Disable telephone line monitoring feature from the panel. Battery Charging A dedicated 14.5V power supply is required if you want to charge a battery Do not fit a battery if power is being supplied by the Alarm panel. Input and Output Output is open collector 12V, 50mA switching negative, for heavier loads a relay must be used. The outputs can be Opened, Closed or Pulsed remotely using the Permaconn Atlas web platform. Ensure there is a common negative between PM1030 and the device being switched. Tamper input does not require an EOL resistor. All other inputs must be terminated with a 10K resistor. Defaulting the Permaconn PM1030 Apply Battery or 14.5V DC power for less than two (2) seconds remove power and then apply power again. LEDS will all flash together for four (4) seconds to confirm successful default. 6

DI300 Powered by Panel PM1030 Powered Independent Supply PM1030 V2 and DI300 Powered by Panel Do not fit a battery when PM1030 is powered by the alarm panel 7

LED Status Indicators PM1030 LED Activity Indication On * Indicates battery or 14.5 Volt Power POWER Indicates unit is off Unit not activated or network is not On * available Blinking (1 sec On -1 Searching for 3G network sec ) GSM Flashing once Connected to GSM Network Indicates connectivity with Permaconn Flashing twice * network On Indicates unit is connected on 'B' sim SIM Indicates unit is connected on 'A' Sim On Indicates low battery voltage or no battery BATTERY connected * Battery voltage correct L Indicates Low signal strength SIGNAL STRENGTH M * Indicates Medium signal strength H * Indicates High signal strength Blinking * Indicates serial /RS485/RS232 connectivity with alarm panel or DI300 COMMS No serial connection between DI300 and Permaconn On * Normal operation Unit is connected to Permaconn network. No connection to network ONLINE/GPOL HEART BEAT Blinking On for 2 seconds 1 flash On for 2 seconds 2 Flash Blinking * Unit is registered on Permaconn Network but has not received message with account details from the alarm panel. Only SIM A is active Only SIM B is active Indicates the unit has completed a power up test and is working properly No Power or unit is faulty * Normal Operation 8

LED Status Indicators DI300 Normal operation Heart Beat Link Phone line Panel Hook Panel Comms GPRS Blinking Blinking Steady On Steady On The following table shows Various LED Indications during normal operation. LED Activity Indication Heat Beat Link PSTN Hook Blinking Blinking On On When the CPU has completed a power up test and is working properly Unit is faulty Indicates connectivity between the PM1030 and the DI300 Indicates fault with wiring between PM1030 and DI300. Check blue and white wire Indicates that there is no line voltage on the incoming telephone (from the exchange). Indicates PSTN line voltage Indicates that the alarm panel dialler has grabbed the line. Alarm panel is not attempting to grab the line Panel Comms GPRS On Pulses On Indicates that the alarm panel sent a valid Contact ID message. when panel dials or sends a message panel has not sent a valid contact ID message Indicates connectivity to the PM1030 The Permaconn unit is off line. DI 300 will not operate. 9

Final Commissioning Check List HEART BEAT LED Blinking Online/GPOL LED Steady On COMMS LED blinking Signal Strength LED (L/M/H) is M or H BATTERY LED is POWER LED is On Tamper switch connected Test 3G communication Make sure Permaconn PM1030 is connected. Generate event from alarm panel. Verify with monitoring centre that correct CID account and event received. Test alarm panel PSTN communication Remove jumper from DI300 Generate event from alarm panel. Verify with monitoring centre that correct CID account and event received via PSTN. Test Permaconn PM1030 communication Trigger the tamper input on Permaconn PM1030. Trigger outputs and inputs Verify with monitoring centre that correct CID account and event received. 10

Contact ID Reporting Codes To comply with AS2201.5 these event IDs must be mapped correctly at the monitoring centre. Event ID PERMACONN AUST CONTACT ID EVENT TEMPLATE Partition Zone Description 300 0 956 Panel Faulty - No activity detected from alarm panel indicating possible problem with panel. 301 0 950 Mains Fail No AC power available. 302 0 951 Battery Low Battery voltage is low or absent. 313 0 953 & 954 337 0 950 338 0 951 350 0 953 351 0 352 0 954 & 956 955 & 956 353 0 956 Engineering Reset (changed encryption key) No action required. Expansion Module DC Loss 13.8V DC voltage low or absent. Expansion Module Battery Fail Battery voltage is low or absent. Fail To Communicate Permaconn experienced trouble sending signals do not expect restore. Phone Line Fail. 356 0 968 IP path poll fail. 356 0 969 3G path poll fail. 356 0 970 Dialer Interface Lead Fail Issue with dialer lead between Permaconn unit and the alarm panel. Serial Interface Fail Issue with Permaconn unit serial connection to the alarm panel. Permaconn Outstation Permaconn outstation is offline. 137 0 983 Tamper Permaconn box tamper. 140 0 981 Auxiliary 1 Auxiliary input on Permaconn unit. 140 0 982 Auxiliary 2 Auxiliary input on Permaconn unit. 140 0 983 Auxiliary 3 Auxiliary input on Permaconn unit. 140 0 984 Auxiliary 4 Auxiliary input on Permaconn unit. 11

Transmission Delay Times Tamper input status message are transmitted immediately. Message originating from the panel are forwarded immediately. Alarm panel interface fail sent if not restored within 90 seconds. Specifications PM1030 V2 Size: 142 x 100 mm Weight: 0.25 Kg Antenna: Dual Band 2G & 3G 3G & NEXT G Modem: Siemens Power: 14.5V DC Plug pack must have approval Power Consumption: Standby: 0.05A Transmitting: 0.60 A Power Reporting: Powered from 14.5V plug pack. DC-Loss reported <11.8v DC-OK reported >12.8v Battery Low reported <11.6v Battery OK reported >12.5v Backup Battery: 12V/1.2AH sealed lead acid battery (Powers unit for about 30 hours) Auxiliary Input: TT, tamper input, (24Hr Zones) State change detected every second Serial Interface: Consult the relevant serial interface specifications Battery Low Fail DCV<11.8 Report delay 10 minute Restore DCV>12.5 Immediate Communications Class: As per compliance statement Size: 70 x 50 x 20 mm Power: 10 15V DC 0.3A Power Consumption: Standby: 0.12A Dialler Interface: Accepts Contact ID (ADEMCO-685) Telephone Lead: Fail DCV< 4V for more than 18seconds Restore DCV > 5V for more than 8 seconds Interface Lead (Dialler): Fail DCV< 4V for more than 18seconds Restore DCV > 5V for more than 8 seconds Response Dialler Interface: < 10 sec typical (seizing line to receiving ACK) < 50 sec absolute maximum Serial Interface: < 2 sec typical (dispatch to receiving ACK) < 50 sec absolute maximum 12

Warning INSTALLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES. For correct operation the unit must be powered with an approved power supply and a 12V/1.2AH sealed lead acid battery. The unit must only be operated with the supplied antenna. Install the Permaconn PM1030 in a location that no person[s] is closer than 200 mm to the antenna at all times. Australian Standard AS2201 requires regular service by qualified and licensed technicians and regular testing. The unit must be installed in accordance with this manual and AS2201.1 for proper operation. Standards Compliance In this manual, AS2201.1 refers to AS/NZS 2201.1:2007, AS2201.5 refers to AS/NZS 2201.5:2008 and AS2201 refers to the current issues of the AS2201 range of documents. In order to achieve compliance with AS2201.5, the terms of the current issue of the document Permaconn AS/NZS 2201.5:2008 Compliance Statement must be met. Note that the overall alarm transmission system configuration needs to comply with AS2201.1 and AS2201.5. It is stressed that the supervised premises alarm panel is be installed and maintained in order to meet Class (as relevant to the alarm transmission system classification) under AS2001. The logbook required under Clause 6.4 of that Standard is to remain current. The monitoring centre is to hold a copy of the documentation required at AS2201.5 Clause 2.3. The monitoring centre is to maintain fault and maintenance logs in accordance with AS 2201.5 Clause 3.9.on. Subject to the Standard Terms and Conditions set out on the Activation Form for this unit. Liability While every effort has been taken to ensure the accuracy of this document, Radio Data Comms assumes no responsibility or liability for any errors or omissions. Radio Data Comms reserves the right to make changes to this manual due to ongoing development. 13

Notes NOTES 14