NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Similar documents
LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

What is a Closed circuit Cooling Tower (CCT)?

Mr. GoodTower Service Center

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

PAD. Adiabatic cooler. PAD series

LOW STATIC HYDRONIC DUCTED UNIT

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

What is Cooling S.Sen

SECTION COOLING TOWERS

Closed Circuit Cooling Towers

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Series 1500 Cooling Tower Specification

Closed Circuit Cooling Towers

Commercial Evaporative Cooling

DESCRIPTION OF COOLING TOWERS SERIES TAT

Evaporative Condensers

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

JCseries EVAPORATIVE CONDENSER. engineering data

DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Evaporative Condensers

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

SNOWCOOL SYSTEMS INDIA PVT LTD.

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Operation & Maintenance of Cooling Tower

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Privately held company

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Centrifugal Blower. Backward/Aerofoil Curved.

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Compass Series Open Cooling Towers

Commercial Evaporative Air Conditioning

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

/ Aquatower Fiberglass Cooling Tower /

SECTION STEAM CONDENSATE PUMPS

Leadership, Innovation, Advanced Technology Synergise Here!

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

AIR HANDLER SPECIFICATION

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

AT, MT & ES Series Super Low Sound Fan

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

3PT HITCH MOUNTED MIST BLOWER AT LOW VOLUME

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Reliable products with long-term, low cost of ownership

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

SECTION COOLING TOWERS

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

Centeral Station Air Handling Unit

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

EHH SERIES DRAW THROUGH FAN COILS CFM

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

39G Air Handling Unit

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

LED New Light Source Reflow Oven. Model: T-960

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Aquatower STEEL COOLING TOWER. engineering data and specifications

AIR HANDLING UNITS MANDÍK

VOLUME 2 (BOQ & Price Bid)

Double Skin Casing Air Handling Units

DRY BULK HANDLING SYSTEM

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

BORS - Bilge Oil Removal Systems

Efficient, Long Lasting Evaporative Condensers

Layout. Guidelines11. Chapter 11: Layout Introduction

GRAVITY SCREEN FILTER

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Mini SMT Reflow Oven Model: T-961

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CONTENT ANHUI KOYO BEVERAGE MACHINERY CO LTD 安徽蓬源饮料机械有限公司 1.MACHINE EXPLAINATION 2 2.MACHINE MAIN STRUCTURE 2 3.MACHINE PARAMETER 8

TOPAZ ADIABATIC COOLER

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Chocolate Cooling Tunnel

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

Chemistry diaphragm pumps

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

Equipment Information

Transcription:

Product Introduction NCF series centrifugal fan forced draft cooling tower is a type of cooling tower designed to protect the environment from our years of cooling tower equipment design, production, operation, maintenance experience, combined the advanced heat exchange technology and scientific production management, it is an advanced innovation product. NCF series cooling tower is all-metal construction, avoided to cause any harm to the environment and human body regarding the production process of FRP material, and also avoided serious impact to the environment and ecological balance during the long term degradation process of FRP. Casing is made of zinc magnesium aluminum or stainless steel plate, equiped with low noise multi-wheel centrifugal fans. The fan and its driven system are installed at the bottom of cooling tower, it easily makes to control the noise level, and avoided the corrosion caused by saturated moisture, ensured longer service life and facilitated cooling tower of daily maintenance work. Closed water basin can effectively isolated direct sunlight to the cooling water, effectively controlled the algae bacteria breeding and avoid causing bacteria "veterans". NCF series centrifugal fan forced draft cooling tower adopts the single side into the wind design, can undertake more towers assembling, suitable application in indoor, outdoor and tunnel, etc. -1-

Features Beautiful appearance, flexible combination, high thermal efficiency, small footprint, environmental protection, low noise, easy maintenance, long service life. Frame structure: Modular structure, use the high quality of zinc magnesium aluminum material (304 or 316 stainless steel for option), which is standardization made by Z600 galvanized anti-corrosion processing. After passivation treatment, cooling tower can withstand water PH value 6.5-9.0. At the same time, the component design strength can bear the wind pressure of 1440 Pa, Protected the product quality and ensured stable running. Equipment can be ordered according to singlecell or multi cells. Casing Using high quality imported galvanized aluminum plate, high strength, strong anti-corrosion ability, beautiful appearance, smooth and easy assembly, etc. Centrifugal fan Using the centrifugal fan, through static and dynamic test of production process, to meet the cooling tower heat transfer performance under the premise of maximum noise reduction. Driven system Using multi channel V belt transmission, the design of the belt based on 150% of the motor rated power. Smooth running, low noise, fan bearing with conical roller bearing, large carrying capacity, long life, rated life over 20,000 hours Motor Using closed cooling tower dedicated motor, IP55 protection grade, insulation class is F, suitable for hot and humid environment to run for a long time. Products comply with IEC international standards, with high efficiency, low noise, long life, reliable operation, etc Fill media Using the high quality of modified PVC materials, the heating vacuum forming the diaphragm of the wet packing, with uv resistance, chemical resistance, changing the characteristics of high thermal efficiency. Drift eliminator Using high quality cellular drift eliminator, not only the small resistance, and effectively reduced cooling water loss dropped to no more than 0.001% of the circulating water. Nozzle Using independent design of the nozzle of our company. The nozzle sprays the water uniformly under the condition of low pressure water, adopts the design of large diameter, internal without moving parts, maintenance free, small resistance, greatly improved thermal efficiency of cooling tower. Access gallery The access door is designed at both ends of the cooling tower, convenient access to the fan room for repairing or maintenance work. -2-

Water basin Using the high quality steel plate thickness profile, supporting the various pipeline interface, outlet is also equipped with filter, hydrating mouth built-in brass valves, large diameter plastic floating ball, automatically adjust the water level, water plate design for large capacity, high water level. Construction Material Model NCF- NCF-S NCF-SS Frame galvanized magnesium Casing aluminum plate Water Basin 304# stainless steel 316# stainless steel Bolts&Nuts 304# stainless steel 304# stainless steel 316# stainless steel Nozzle ABS plastic Fill Media PVC film fill Drift Eliminator PVC celluar type Fan Zinc-coated centrifugal fan Sinlencer Asbestos board -3-

Technical Parameters Item Water flow Power Dimension (mm) Weight (kg) Model m³/h kw Length Height Inlet pipe Outlet pipe Net Operation L H diameter diameter weight weight NCF-100 100 11 2800 4350 200 200 2200 5300 NCF-125 125 15 2800 4350 200 200 2200 5300 NCF-135 135 18.5 2800 4350 200 200 2200 5300 NCF-150 150 22 2800 4710 200 200 2200 5300 NCF-165 165 22 2800 4950 200 200 2200 5300 NCF-180 180 22 3800 4350 200 200 3350 7200 NCF-200 200 22 3800 4710 200 200 3350 7200 NCF-220 220 30 3800 4710 200 200 3350 7200 NCF-235 235 30 3800 4950 200 200 3350 7200 NCF-250 250 37.5 3800 4950 200 200 3350 7200 NCF-265 265 18.5x2 5480 4350 250 250 5050 11800 NCF-290 290 18.5x2 5480 4710 250 250 5050 11800 NCF-305 305 18.5x2 5480 4710 250 250 5050 11800 NCF-325 325 18.5x2 5480 4950 250 250 5050 11800 Design condition: Inlet hotwater temperature 35, Outlet cold water temperature 29.5, Design wet bulb temperature: 25.5 ; Atmosphere: 99.4Kpa. Outline Dimension -4-

Outline Dimension With Silencer Model Dimension A B C NCF100 ~ 165 2800 1000 1200 NCF180 ~ 250 3800 1000 1200 NCF265 ~ 325 5480 1000 1200 Foundation ` Model NCF-100 NCF-125 NCF-135 NCF-150 NCF-165 NCF-180 NCF-200 NCF-220 NCF-235 NCF-250 NCF-265 NCF-290 5680 NCF-305 Remarks: NCF-325 1. The above drawing are the initial layout, Please ask for detailed drawing when place order. 2. We reserve the rights to modify the above parameters without further notice. D 3000 4000-5-