Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Similar documents
MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Cooling Tower Designs

Lenntech. Tel Fax

Closed Circuit Cooling Towers

What is Cooling S.Sen

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

CTI Sponsored Educational Program

BECAUSE TEMPERATURE MATTERS: MAINTAINING COOLING TOWERS

Evaporative Cooling Products

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Direct and indirect evaporative cooling

Closing the Loop What s best for your system?

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

PAPER NO: ANDREW RUSHWORTH

Air-Handling System Cooling Options

HYBRID ADIABATIC Cooling System

Products and Services

INFO. Stainless Steel Evaporative Cooler. The New Choice In Evaporative Cooling

Since its founding in 1976, EVAPCO,

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Air-Handling System Cooling Options

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

How about Savings in Time, Money, Energy and Longer Life?

PAD. Adiabatic cooler. PAD series

Evaporative Condensers

INFO. Evaporative Condenser Stainless Steel MW. The Best Choice In Evaporative Cooling

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Improving Condenser Safety In Cold Chain Facilities

Available in Capacities from 208 to 2,050 Ammonia Tons!

Mr. GoodTower Service Center

Bulletin 241B. Mark owned by the Cooling Technology Institute

MECHANICAL SERVICES 101. Ian White

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Efficient, Long Lasting Evaporative Condensers

DISTRIBUTION SYSTEMS. Water Piping and Pumps

SNOWCOOL SYSTEMS INDIA PVT LTD.

Un-Used Series CXV Evaporative Condenser

Privately held company

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

SECTION COOLING TOWERS

C E R T I F I E D E N I S O

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

Bulletin 242-E Metric C E R T I F I E D E N I S O Mark owned by the Cooling Technology Institute

Chilled Water system

Bulletin 241-E Metric C E R T I F I E D E N I S O Mr. GoodTower

EVAPORATIVE COOLING, a natural occurrence

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Gas-Fired Double-Effect Chiller-Heater

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

Evaporative Cooling products

Layout. Guidelines11. Chapter 11: Layout Introduction

TOPAZ ADIABATIC COOLER

THE TRUSTED ADIABATIC COOLER AND CONDENSER

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

QuadraFlow Cooling Tower

PDF Created with deskpdf PDF Writer - Trial ::

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

XLP2 Evaporative Condensers

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Case 13 Food Storage & Processing Center

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Application Guidelines

Operation & Maintenance of Cooling Tower

MU053: CHILLERS: Operation & Maintenance of Chilled Water Systems

Technically Driven Heat Exchangers

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

ENERGY SAVING, EASY TO INSTALL AND MAINTAIN FORCED DRAFT, AXIAL FAN CONDENSERS

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

EVAPORATIVE AIR-COOLING EQUIPMENT

Reliable products with long-term, low cost of ownership

SYSTEM DESIGN REQUIREMENTS

/ Aquatower Fiberglass Cooling Tower /

215 till kw nominal capacity

Series 1500 Cooling Tower Specification

SNOWCOOL SYSTEMS INDIA PVT LTD.

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

EqUIPMENT LAYOUT MANUAL

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

Lenntech. Tel Fax Engineering Data & Specifications

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

MAINTENANCE INSTRUCTIONS

Air-Cooling Evaporators

c o n d e n s e r Glossary of Terms

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

CONTENTS. B. System Design and Performance Requirements

General Catalogue. FORM SSI - G.C (94)

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Chapter 14, Problem 27.

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

/ Atmospheric Heat Vaporization Systems for LNG Import Terminals /

HVAC (Heating, Ventilating, and Air Conditioning)

TrilliumSeries. Condenser

Transcription:

ow

Brett Alexander Presenters Mihir Kalyani Troy Reineck

Designing Your Water Treatment Program for Different Types of Heat Rejection Equipment

Types of Heat Rejection Equipment Open Cooling Tower Closed Circuit Cooler / Evaporative Condenser Hybrid System Adiabatic Cooler / Condenser Dry Cooler / Condenser

Typical HVAC System Condenser Water Loop Chilled Water Loop

Typical Materials of Construction Galvanized Steel Stainless Steel Type 304/316 most common Type 301 lower grade/less chloride resistant Fiberglass reinforced polymer (FRP)

Materials of Construction Manufacturer s equipment IOM provides water guidelines Chloride tolerance dependent on temperature

Open Cooling Towers Different Designs & Types Components Principle of Operation

Different Types of Open Cooling Towers Forced Draft fan towards the bottom pushing air through the unit Usually Counterflow Induced Draft fan on the top pulling air through the unit Counterflow Crossflow

Fan pushes air into the tower Smaller Footprint Hard to inspect Minimal sunlight inside unit Forced Draft Towers

Induced Draft Towers More energy efficient Versatile layout options Simplified maintenance Generally used for larger installations

Induced Draft Counterflow Towers Fan and Motor Lock out before inspection Drift Eliminators 0.0005% drift rate Spray Nozzles Different types

Induced Draft Counterflow Towers Fill Where the heat transfer occurs Louvers Blocks sunlight and large debris Basin Typically lower water volume versus crossflow

Induced Draft Crossflow Towers Fan and Motor Lock out before inspection Distribution Decks Sunlight = Algae Louvers, Fill and Drift Eliminators Higher drift rate (about 5x more)

Induced Draft Crossflow Towers Larger water volume in basin = more biocide More debris and sunlight gets in the basin

Algae Growth Counterflow Crossflow Louver removed for photo Normal operation

Principle of Operation Heat is rejected by the evaporation of pure H 2 O Dissolved solids from the makeup water concentrate in the condenser water Great air scrubbers adds suspended solids Evaporation Make-Up Blowdown

Principle of Operation Blowdown (or bleed) removes higher TDS in recirculating water from the tower Cycles of Concentration BD = Evap / (COC -1) Evaporation Make-Up Blowdown

Tower + Chiller 95 F LOAD LOAD 85 F Condenser water is exposed to the atmosphere via tower Can cause fouling in the chiller tube bundle

Tower + Heat Exchanger 95 F 100 F LOAD 85 F 90 F Process water separated from cooling tower via heat exchanger Heat exchanger adds complexity to treatment and maintenance programs (small passes)

Closed Circuit Coolers 95 F 85 F WSHP Data Center Hospital Equip Industrial Process LOAD

Closed Circuit Coolers Different Designs & Types Components Principle of Operation

Closed Circuit Coolers Coils inside the unit Bare, elliptical, finned Recirculating water distribution system Pump, riser pipe

Evaporative Condensers Similar to closed circuit cooler Induced or Forced Draft Main difference what is in the coil Condenses the refrigerant NH3 R-22

Coils for Coolers and Condensers Coils can be enhanced to improved efficiency Internal rifling External fins Hot Dipped Galvanized is the most common construction Galvanized: remember to offer a site-specific passivation plan Stainless Steel: no passivation, but test chlorides routinely

Water Treatment for Coolers and Condensers Integral pump units (shown) typically have low spray water pressure (2 to 6 psi) Supplemental circulating pump may be required for liquid chemical feed systems Select biocides based on short retention time

Water Treatment on Coolers and Condensers Low water volume and high turnover rate compared to open cooling towers Ensure good mixing (dilution) of chemicals prior to returning to basin Return treated water below the coil

Passivate New Galvanized Steel To minimize White Rust & ensure service life What is White Rust? Premature localized corrosion of the protective zinc layer Read AWT s 2012 Guide Paper

What does passivated zinc look like Shiny Dull

Hybrid System Evaporative Mode Dry Mode

Dry Coolers and Condensers V-Bank Flat Air Process fluid inside coil requires glycol or treatment Air

Adiabatic Coolers and Condensers Adiabatic pads depress the dry bulb temperature of the entering air Water wets these pads May require pretreatment Some equipment may have a basin and recirculating pump

Remember Understand the equipment you are treating Know the materials of construction Learn the operation of the cooling system Not all systems are the same BE SAFE