Selecting the Correct Fan

Similar documents
Introduction to Fans. The Basics of Fan Principles and Terminology

Fans: Features and Analysis

Ducted Propeller. Airflow Volume

A. Codes and Standards that are Standard at the University:

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

The Advantages of Choosing Centrifugal Fans

MXI Mixed Flow Inline Fan

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Glossary of Terms Laboratory & Fume Exhaust Fans

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Fan Performance and Selection. Overview

Fan Arrangements, Rotation, Discharge and Motor Position

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Industrial Fans & Blowers

Twin City Fan & Blower

FANS & BLOWERS ENERGY EFFICIENCY REFERENCE GUIDE TRAINING & SUPPORT

SECTION (15833) - HVAC POWER VENTILATORS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Centrifugal Fans, Non-Overloading, Backward Inclined

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

DAE Systems. Fan Selection Guide. Section 1: Terminology

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Copy Right By: Thomas T.S. Wan

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

FANS & BLOWERS. Energy Efficiency Reference Guide. Airflow Volume. Ducted Propeller

Direct Fired Heater Model AD Specification

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

BULLETIN G-99. March 2005 CONDENSED CATALOG. Air Moving Products

Bulletin FH05 FUME EXHAUST

QUICKSHIP PROGRAM. Twin City Fan QuickShip

Twin City Fan & Blower

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Fan Selection. and Energy Savings

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

University of Houston Master Construction Specifications Insert Project Name

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

QUICKSHIP PROGRAM. Twin City Fan QuickShip

1.1 This section applies to air handling units for HVAC Systems.

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

Modular Supply Make-Up Air Unit

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SECTION AXIAL FANS

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Wilo IL Vertical Split-Coupled Inline Pumps

Selecting Fans and Determining Airflow for Grain Drying and Storage

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

Centrifugal Blower. Backward/Aerofoil Curved.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

an ISO 9001 Company Bulletin PR-112

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

JM Aerofoil Fans Bulletin JMA60-05

Product Data. Features/Benefits The Aero 39M air handler is the only unit on the market that practically installs itself.

Fuji Electronic VFC 084P-5T

Air Make-Up Units. Product Line Overview & Capabilities

Fan Blades & Accessories

Direct Gas-Fired Make-Up Air

MACHINERY BLOCKING RECOMMENDATIONS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

KIC Air Curtains. Technical Guide

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

Submittal Data Performance Data Electrical Data

Understanding Fan System Effects

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

Proposal Information Template Commercial and Industrial Fans and Blowers 2017 Appliance Efficiency Standards

A. This Section includes air-handling units with coils for indoor installations.

CML Northem Blower Inc. Air Movement Equipment

GreenJet Transfer Fans

Belt Driven Mixed Flow Fans

Indirect Gas-Fired Make-Up Air

XeteX, Inc. All Rights Reserved.

AcoustiFlo Fans: Retrofit Solutions and Beyond

CONTENTS. B. System Design and Performance Requirements

B. System Design and Performance Requirements

Trane Engineers Newsletter Live

SECTION AIR HANDLING UNIT

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Contents INDEX. TDM Series Indirect Fired Heaters

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Centeral Station Air Handling Unit

Tunnel Axial Flow Fan

Transcription:

Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1

Your Speaker circa 1998 Fan Types Applications Performance Characteristics Fan Construction Drive Arrangements Fan Rotation and Discharge Fan Class of Construction Spark Resistant Construction Special Coatings and Materials Fan Selection Considerations Motors V-belt Drives Air Volume Control 2

Basic Fan / Wheel Types Centrifugal Backward Inclined Airfoil-blade Backward Inclined Flat-blade Forward Curved Blade Radial Blade Radial Tip Axial Propeller / Panel Fan Tubeaxial Vaneaxial Special Designs Power Roof Ventilators Tubular Inline Centrifugal Mixed Flow 3

Backward Inclined Airfoil Blade Name is derived from the airfoil shape of blades Developed to provide high efficiency Used on larger HVAC and clean air industrial systems where energy savings is key Not well suited for dirty airstreams, can have balance issues 4

Backward Inclined Flat Blade Backward inclined blades are single thickness or flat Efficiency and FRPM are slightly less than airfoil blade The most widely used wheel design Used for applications where airfoil blade is not acceptable due to dirty, hot, corrosive or erosive airstream 5

Backward Inclined Flat & Airfoil Stable performance characteristic Non-overloading power curve High volume at moderate pressure Low abrasion resistance High efficiency Low noise 6

Forward Curved Blade Blades are curved forward in the direction of rotation Less efficient than airfoil or flat blade designs Requires the lowest speed of any centrifugal to move a given amount of air Used for low pressure HVAC systems 7

Forward Curved Blade OVERLOADING power curve Must be properly applied to avoid unstable operation Clean air and high temperature applications Higher volume at low pressure Small size for a given volume 8

Selecting for Overloading HP 8600 cfm @ 1.8 in wc (4.84 BHP) 10000 cfm @ 1.5 in wc (5.97 BHP) 9

Radial Blade Blades are flat and radial to the fan shaft Generally the least efficient of the centrifugal fans Material handling and moderate to high pressure industrial applications 10

Radial Blade OVERLOADING power curve Material handling, self cleaning Suitable for dirty airstream, high pressure, high temperature and corrosive applications Low volume at high pressure Moderate efficiency Easy to maintain 11

Radial Tip Similar to backward inclined near the hub, but gradually slope towards the direction of wheel rotation ending in a radial direction at the blade tip More efficient than the true radial blade Designed for wear resistance in mildly erosive air streams 12

Common Propeller Types Adjustable / fixed pitch cast aluminum Stamped / extruded aluminum Fabricated / die formed steel Polymer / composite Almost limitless number of configurations 13

Propeller or Panel Fan One of the most basic fan designs Low pressure, high volume applications Designed for ventilation through a wall Ring fan design offers slightly higher pressure 14

Propeller or Panel Fan Propeller panel fans are best utilized near free air 15

Tubeaxial Fan More efficient than the panel fan Cylindrical housing fits closely to outside diameter of blade tips Low to medium pressure ducted industrial and commercial HVAC systems Air Flow 16

Tubeaxial Fan Performance curve sometimes includes a dip to the left of peak pressure which should be avoided 17

Highest efficiency propeller axial fan Cylindrical housing fits very closely to outside diameter of blade tips Straightening vanes allow for greater efficiency and pressure capabilities For medium to high pressure HVAC systems Straightening Vanes Vaneaxial Fan Air Flow 18

Vaneaxial Fan More compact than centrifugal fans of same duty Aerodynamic stall causes the performance curve to dip to the left of peak pressure which should be avoided 19

Specialized Adaptations Spun aluminum fans for roof mounted exhaust applications Upblast or downblast configurations Available with our without discharge dampers Can utilize centrifugal wheels, props or mixed flow impellers 20

Plenum/Plug Fan Offers tremendous flexibility for inlet and discharge in a AHU application Works better than a housed centrifugal for high flows and low SP Wall clearance rules must be followed to avoid significant system effect losses Housed vs. plenum fan 21

Inline Centrifugal Fan Wheel is generally an airfoil or backward inclined type Housing does not fit close to outer diameter of wheel For low and medium pressure HVAC systems or industrial applications when an inline housing is geometrically more convenient than a centrifugal configuration Airflow 22

Mixed Flow Fan Cylindrical housing is similar to an inline centrifugal High volume advantages of axial propeller Low sound, high efficiency advantages of tubular centrifugal 23

Typical Application Range The required flow and pressure may control the style of fan used Pressure Centrifugal Axial Flow 24

Drive Arrangements Fan Rotation and Discharge Fan Class of Construction Spark Resistant Construction Special Coatings and Materials Fan Construction 25

Drive Arrangements for Centrifugal Fans Arrangement 10 SWSI Belt drive Impeller overhung Two bearings with motor mounted inside base 26

Drive Arrangements for Centrifugal Fans Arrangement 9 SWSI Belt drive Impeller overhung Two bearings with motor mounted outside base 27

Drive Arrangements for Centrifugal Fans Arrangement 1 SWSI Belt drive Impeller overhung Two bearings on base Motor mounted beside fan, typically on a common base 28

Arrangement 4 SWSI Direct drive Impeller overhung on prime mover shaft No fan shaft / bearings Motor base mounted or integrally directly connected Drive Arrangements for Centrifugal Fans 29

Drive Arrangements for Centrifugal Fans Arrangement 8 SWSI Direct drive Arrangement 1 plus extended base for motor Motor coupled to fan shaft 30

Arrangement 3 SWSI Belt drive One bearing on each side supported by fan housing Motor mounted off the fan, typically on a common base Drive Arrangements for Centrifugal Fans 31

Drive Arrangements for Centrifugal Fans Arrangement 3 DWDI For belt drive (or direct) connection One bearing on each side and supported by fan housing Motor mounted beside fan, typically on a common base 32

Drive Arrangements for Centrifugal Fans Arrangement 7 SWSI For direct drive connection Arrangement 3 plus base for motor Motor coupled to fan shaft 33

Drive Arrangements for Centrifugal Fans Arrangement 7 DWDI For direct drive connection Arrangement 3 plus base for motor Motor coupled to fan shaft 34

Motor Positions for Inline Fans Rotation of impeller is determined from outlet end Horizontal or vertical mounting Hanging or floor / base mounting Belt driven motor positions are determined from outlet end 35

Motor Positions for Belt Drive Centrifugal Fans Location of motor is determined by facing the drive side of fan and designating the motor position by letter W, X, Y or Z 36

Rotation & Discharge Positions Clockwise rotation as viewed from drive end Up Blast Top Angular Up Top Horizontal Top Angular Down Down Blast Bottom Angular Down Bottom Horizontal Bottom Angular Up 37

Rotation & Discharge Positions Counter-clockwise rotation viewed from drive end Up Blast Top Angular Up Top Horizontal Top Angular Down Down Blast Bottom Angular Down Bottom Horizontal Bottom Angular Up 38

Fan Class of Construction AMCA designates minimum performance requirements for certain types of fans to determine fan class 1) Backward Inclined, SWSI and DWDI 2) Backward Inclined airfoil, SWSI and DWDI 3) Forward Curved, SWSI and DWDI 4) Inline Centrifugal Construction standards are set based on pressure and outlet velocity (not volume and wheel size) Fan manufacturers use a variety of construction nomenclature (level, duty, numerical, etc.) In addition to performance limitations, fans have structural limitations 39

Centrifugal Fan Minimum Performance Points 40

Spark Resistant Construction Special construction used for applications where a spark may ignite explosion flammable or explosive gas or dust in airstream AMCA Standard 99-0401 has guidelines for spark resistant construction with three levels Type A Type B Type C 41

Spark Resistant Construction Type A All parts of the fan in contact with the air or gas being handled shall be made of nonferrous material Type B The fan shall have a nonferrous impeller and nonferrous ring about the opening though which the shaft passes Type C The fan shall be so constructed that a shift of the impeller or shaft will not permit two ferrous parts of the fan to rub or strike 42

Special Materials / Coatings Abrasion and erosion resistance Easier to clean Corrosion resistance High temperature Spark resistance Aesthetics Safety (OSHA Yellow) 43

Coating Selection 44

Motor Characteristics Power (HP, kw) Service Factor (Typically 15% or 1.15 SF) Reverts to 1.0 when used with a frequency drive Physical Size in T-Frame or U-Frame (Automotive) Rotational Speed (RPM - Revolutions Per Minute) Typical Motor Speeds (RPM) 60 Hz Power 50 Hz Power # of Poles Synchronous Under Load # of Poles Synchronous Under Load 2 3600 3500 2 3000 2900 4 1800 1770 4 1500 1450 6 1200 1170 6 1000 970 8 900 870 8 750 720 45

Motor Characteristics Enclosure: Open Drip Proof (ODP) Totally Enclosed (TEFC, TEAO, TENV) Severe Duty (Mill & Chem., Hostile Duty, Dirty Duty...) Explosion Proof Division I = Explosive agent present under normal operating conditions Division II = Explosive agent only present under abnormal operating conditions Class Defines types of hazardous materials (gases/dusts/fibers) Group Defines the relative degree of hazard for each type of hazardous material 46

Motor Efficiency EPAct (Energy Policy Act of 1992) Standard efficiency (1HP and above) EISA (Energy Independence and Securities Act of 2007) Effective December 19, 2010 EPAct efficiency eliminated (1HP and above) Motors manufactured for use in the US must meet the minimum efficiencies listed in NEMA MG 1, Table 12-12 47

Direct Driven Disadvantages More difficult to make fan selections May require modified wheel Couplings can be difficult to align on Arrangement 7 or 8 fans Advantages More compact Less maintenance No drive loss Easier to balance to low vibration levels 48

V-Belt Drives Disadvantages Requires more maintenance More difficult to guard Belts create dust (clean room problem) Tougher to achieve tight balance Drive losses due to belt slippage Advantages Easy to change fan speeds and performance Easy to make fan selection 49

Estimated Belt Drive Loss Higher belt speeds tend to have higher losses than lower belt speeds at the same horsepower Drive losses are based on the conventional v-belt which has been the work horse of the drive industry for several decades Typically, an additional 5% to 7% should be added to fan BHP for sizing motors 50

Timing Belt Drives Not recommend for use on fans by most fan manufacturers Noise (up to 13 dba louder than V-Belt drives) Alignment is critical No slip characteristic is hard on motors Increased vibration Cost (2-3 times more expensive than V-Belt drives) 51

Belt Drive Final Comments Adjustable sheaves not recommended for drives over 10 HP Cost Adjustable sheaves are 2-3 times more expensive than fixed sheaves. Adjustable sheaves use set screws to lock in pitch diameters and set screws can vibrate loose. Belt life is shorter on adjustable pitch drives (belt rides higher or lower in sheave). Dual groove drives not recommended with fractional HP motors Motor may not be able to start fan because of the additional resistance from the extra belts. 52

Variable Volume Systems Available methods of adjusting volume will vary with fan type Is near constant pressure a requirement? Technology is rapidly changing the preferred options for these applications Controllable pitch axial Two-speed motors Dampers, outlet or inlet vanes Multiple fans in parallel Single phase motor speed controllers Variable Frequency Drive (VFD) Electronically Commutated Motor (ECM) 53

Selecting the Correct Fan Selecting the correct fan involves considering and prioritizing variables Application Performance (flow and pressure) First Cost of Fan Operating Costs Life, Durability & Reliability Space Requirements Simplicity of Installation High Temperatures and Severe Environments Variable Volume Requirements Sound Output Etc... 54

Questions? Ryan Johnson rjohnson@airpurificationcompany.com 55