DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

Similar documents
WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

SCENE 2x2 INSTALLATION INSTRUCTIONS. Recessed T-Bar GENERAL SAFETY INSTRUCTIONS: NOTE:

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

DHL-LP-LED Low Profile LED Linear High/Low Bay

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades.

1 General Description

Installation Manual. Models 99168, 99169, 99170

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Owner s Guide and Installation Manual

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Ceiling Fan Blade Arm Replacement

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

Installation Instructions. Tersen. Ratio Canopy 1.5

Owner s Guide and Installation Manual

CEILING FAN OWNER S MANUAL

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

Owner s Guide and Installation Manual

Installation. Leveling

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Owner s Guide and Installation Manual

Table of Contents. Ceiling Bracket Installation

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Owner s Guide and Installation Manual

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Dual Function Bowl Light Kit

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

LED IMPORTANT SAFETY INSTRUCTIONS

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Cold Door 2 LED Retrofit Kit Lighting System

ELSTON 52 CEILING FAN

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Decorative Low Profile Integrated Kit

CEILING FAN OWNER S MANUAL

Owner s Guide and Installation Manual

Table of Contents. 1 M /08/ Hunter Fan Company. What to Expect with. Preparation. Tools Needed.

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

IMPORTANT SAFETY INSTRUCTIONS:

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Preparation. Downrod. Maintenance.

Ceiling Fan Ow n e r s Manual

GLED INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

installation and operation manual for Hunter Ceiling Fans

CEILING FAN OWNER S MANUAL

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

MaxLite LED MICRO-T PANEL

Innovative Lighting Smooth Light Recessed Luminaires

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

CEILING FAN OWNER'S MANUAL

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

Owner s Guide and Installation Manual

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

LED IMPORTANT SAFETY INSTRUCTIONS

Installation and Operation Manual For Hunter Ceiling Fans

Fillmore Small Pendant Assembly and Installation Instructions

WAILEA OWNER S MANUAL

30-YEAR LIMITED WARRANTY

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

110 lm w STANDARD SERIES

Dishwasher. Installation manual DW60M9990AP

LIMITED LIFETIME WARRANTY

ST. KITTS CEILING FAN

installation and operation manual for Hunter Ceiling Fans

Owner s Manual Ceiling Fan Installation Instructions

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

GLED INSTALLATION INSTRUCTIONS

HPNLS-RT. Installation Manual

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

MaxLite LED High Bay Fixtures

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

LED IMPORTANT SAFETY INSTRUCTIONS

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

DRAIN WATER TEMPERING INSTALL

Table of Contents. 1 M /11/13 Casablanca Fan Company What to Expect with Your Installation

READ AND SAVE THESE INSTRUCTIONS

Table of Contents. What to Expect with. Mounting Options. Tools Needed

WPLED 26W INSTALLATION INSTRUCTIONS

SUPRA 52. U.S. Patents: D450,830 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Inde-Pendants Family. 32L Cylinder with Ring Open Ceiling Types. Document No Installation instructions for 32L-CRxx-P-ID 32L-CRxx-P-D

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Installation Instructions

How to install your Nest Protect

LED IMPORTANT SAFETY INSTRUCTIONS

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

1 x4 Dimmable LED RetroFits

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Electric Dryers Instructions 01

Important Safety Instructions. Important Safety Instructions

INSTALLATION INSTRUCTIONS

5Make electrical connections.

Transcription:

Page 1 of 5 IS-DRDP-01 rev.00 DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS NOTE: The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes or contact factory directly for support before attempting anything with uncertainty. CAUTION: Do not assemble fixture runs on floor. WARNING: Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product. GENERAL SAFETY INSTRUCTIONS: 1. Read all instructions prior to installing this fixture. 2. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. 3. All wiring must be performed by a qualified electrician in accordance with national and local building and electrical codes. 4. This fixture must be suitably grounded for your protection against shock hazards and to assure proper operation. 5. Make sure that the power source conforms to the requirements of this fixture. D B T-BAR CENTERS SPACING FIXTURE T-BAR LENGTH T-BAR WIDTH 2 609.9 mm (24.0 ) 123.8 mm (4.875 ) 4 1219.2 mm (48.0 ) 123.8 mm (4.875 ) 8 2438.4 mm (96.0 ) 123.8 mm (4.875 ) FIXTURE FITS STANDARD T-BAR (9/16 & 15/16 ) C A WIRING DIAGRAM PARTS LIST A. Luminaire enclosure B. Wire Entry Plate C. T-bar Mounting Bracket D. End Plate FIXTURE TO REMOTE/INTEGRAL DRIVER INTEGRAL / REMOTE DRIVER TO LINE VOLTAGE

Page 2 of 5 INSTALLATION STEPS Step 1: Remove all fixture packaging EXCEPT the foam support inside fixture. Foam must remain in fixture until fixture is fully secured to T-Bar. Step 2: Remove wire entry panel from fixture Remove wire entry panel from fixture Step 3: Knock out and install BX connector (Supplied by others). Feed BX cable (supplied by others) through connector and wire entry plate. Tighten BX connector screw cable to wire entry plate. Note: Remote driver to be mounted in accessible location within 54ft of fixture. Wire remote driver box to power source. (Wired by others) Step 4: Remove ceiling tiles (where fixture is to be installed) and adjacent tiles for easy access during installation. Step 5: Open T-bar mounting brackets by loosening the Phillips head screws on top of the fixture. Open the brackets to the widest position and tighten the screw. Step 6: Raise fixture above the ceiling and lower the fixture onto the T-bars.

Page 3 of 5 Step 7: Adjust the T-bar mounting brackets snug to the T-bar frame and secure into position using the Phillips screws on top of fixture. Skip to STEP 10 for stand-alone fixtures. Step 8: For continuous runs, detach the joiner plate and 3 screws. Step 9: Slide the end/middle fixture into place (from above) Step 10: Re-attach joiner plate and secure fixtures together with screws. Step 11: Attach safety wires to each mounting bracket. Step 12: Connect cables from BX cable to the fixture driver cables. Re-attach wire entry plate to the fixture. Install all ceiling tiles and remove the foam insert from the light fixtures.

Page 4 of 5 MAINTENANCE STEPS Important: Use clean gloves to avoid adding oil/dirt to reflector surface. Avoid scratching reflector surface by using installation tools with soft plastic rounded edges. PLASTIC LATEX GLOVES SCREWDRIVER Step 1: For LED board maintenance, remove the fixture from the ceiling. Step 2: Unscrew and remove the T-Bar mounting brackets. Step 3: Unscrew and remove the end access panel. Step 4: Unscrew the 2 screws securing the end cap.

Page 5 of 5 Step 5: Remove the end-cap. Step 6: Remove the screws from the top extrusion. Remove side extrusion along with side reflector. Step 7: Unhook power wire to the LED Boards and unscrew the LED screws to remove the LED boards.