ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Similar documents
Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Centro-Matic Automated Lubrication Systems System Controls

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor...

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

WASTEWATER Online UV%Transmission Analyzer

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

UDC 700 Universal Digital Controllers and Indicator Specifications

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Zircomat Oxygen Analyzers

High Pressure Conductivity Monitor

Model 3300 Technical Support and Installation Manual

I/A Series 716C 1/16 DIN Temperature Controller

OMA-300 Process Analyzer

Power Flame Incorporated

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Hydrazine Analyzer Series 2171 Specifications

Series 5000 Hydrazine Analyzer Model 60002

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Ramsey Motion Monitoring Systems

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

APPLIED. OMA-406R Rackmount Process Analyzer

Analog Input Module IC670ALG630

Instruction Manual Model A

DGC-500 DIGITAL GENSET CONTROLLER

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

AS950 REFRIGERATED SAMPLERS

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Dissolved Oxygen Analyzers

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

CLARITY II TURBIDIMETER

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Low Temperature Zirconia Oxygen Analyzer

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 PORTABLE SAMPLERS

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

LC1350 Level Controller

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Generator Gas Analyzer (GGA)

Temperature Controllers

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

H&O DIE SUPPLY, INC SPR-2000-JR. Programmable Fluid Controller Interstate 20 Kennedale, TX 76060

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Tri-Tech Medical Inc.

BC3250. Blowdown Controller

EC3-X33 Stand-alone Superheat Controller Technical Data

UDC100 Universal Digital Controller Specifications

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Danfoss gas detection units

Toxic Gas Detection. Model F12. Toxic Gas Detection

OPTISENS TUR 2000 Technical Datasheet

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

for Drinking Water Systems

1.2.3 Returning Instrument for Repair.

Analog Room Pressure Monitor RPC Series

Using the DewTrak II Dew Point/ Humidity Transmitter

LEAKSTOPPER RANGE Multizone water leak detection systems

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

/8 DIN Level Indicator

02/11/2015

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

RTD TEMPERATURE SENSING SYSTEM

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

86BSD Digital Output

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Water Detection Controllers

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

910 Series Single-point heat-tracing control system

PUV, PIR and PFO Series BROCHURE

Transcription:

SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist of an analyzer Model 7011A and the appropriate sensor for the range being measured. The system shall operate on either 115/230 VAC, 50/60Hz. The analyzer shall be provided with an thermostatically controlled heater for temperatures below -10 Deg. C. Suspended Solids Analyzer Model 7011A - The analyzer shall be housed in a NEMA 4X enclosure with brackets for wall or standard two inch Dia. round handrail mounting as required. The analyzer shall be fully microprocessor controlled. The system shall be capable of being calibrated to a known value without removing the sensor from the process. The analyzer shall have the following minimum features: 1. An LCD display of a minimum 1.5" x 2.2" (64 x 128 Pixel) This display shall be visible without opening the analyzer cover and shall have the capability of displaying:- A. The reading in either milligrams per liter or density percentage as applicable. B. Individual Menu driven text "Help Screens" for each program parameter. C. Individual "Help Screens" for each step of the calibration process. D. Error messages for the self-diagnostic functions. 2. The analyzer shall have built in self-diagnostic features to alert: A. Sensor light detector failure. B. Abnormal conditions during calibration. C. Internal program failure.3. The analyzer shall have built in "Test" features including: A. Constant current output on demand for both the 4 and 20 milliamps

B. Relay activation test parameter to latch and unlatch the relays on demand. 4. Individually programmable SPDT relays rated Form C, 7 amps resistive. 5. Either a 4-20 ma or 0-1 VDC, Isolated output. Completely programmable by the end user. The latch and unlatch points can be set separately. 6. A Digital Serial RS-485 Interface with programmable baud rates of 300, 6000, 1200, 2400, 4800, 9600, and 19200. 7. The analyzer shall be Auto-Ranging. 8. User selectable calibration linearization curves. 9. Automatic color compensation for the Models 73A. 10. Automatic ambient light compensation for the Model 72A sensor. The Model 72A Low Range Sensor:- The Model 72A Sensor shall contain the light source and photo detector. It shall be automatically compensated for ambient light conditions and have the following minimum Range: 0-1500 mg/l Accuracy: +/- 5% of reading or +/- 5 mg/l, (1.7 NT), whichever is greater. Repeatability: +/- 1% of reading or +/- 2 mg/l (0.5 NT), whichever is greater. Resolution: 1 mg/l Pressure: 0-50 PSIG Cable Termination: Tinned Ends. Mounting: Brackets included to mount to Standard two inch Dia. handrail or as The Model 72P Low Range Pipe Insertion Sensor:- The Model 72P Sensor shall contain the light source and photo detector. It shall be automatically compensated for ambient light conditions and have the following minimum Range: 0-1500 mg/l Accuracy: +/- 5% of reading or +/- 5 mg/l, (1.7 NT), whichever is greater. Repeatability: +/- 1% of reading or +/- 2 mg/l (0.5 NT), whichever is greater. Resolution: 1 mg/l Pressure: 0-20 PSIG Flow: 800 GPM to Drain (Not to exceed 20 PSI)

Cable Termination: Tinned Ends or Connector for Quick-Disconnect Mounting: Sensor Incorporates 3 ANSI Flange. The Model 73B Medium Range Sensor:- The Model 73B Sensor shall contain the phased array light source, and photo detector. It shall be completely submersible. It shall be air or water jet self-cleaning with automatic color compensation and have the following minimum Range: 0-30,000 mg/l 0-3% Accuracy: +/- 5% of reading or +/- 100 mg/l, whichever is greater. Repeatability: +/- 1% of reading or +/- 20 mg/l whichever is greater. Cleaning: Air or Water Jet included. Self contained air or house air/water to be specified Cable Termination: Tinned Ends or JB-93 Junction Box with quick disconnect. Mounting: Handrail Brackets included to mount to Standard two inch Dia. handrail or as The Model 74A High Range In-Line Sensor:- The Model 74A Sensor shall contain the light source, photo detector, and self-cleaning actuator mechanism. It shall be self-cleaning with the following minimum Range: 0-80,000 mg/l 0-8% Accuracy: +/- 5% of reading or +/- 150 mg/l, whichever is greater. Repeatability: +/- 1% of reading or +/- 30 mg/l whichever is greater. Cable Termination: Tinned Ends or JB-93 Junction Box with quick disconnect. Mounting: Shall be into a pipe through a two inch female NPT saddle or similar arrangement provided by the installer. A two inch male NPT insertion nipple shall be provided as part of the sensor assembly. The Model 75A Medium/High Range Sensor:-

The Model 75A Sensor shall contain a light source, and photo detector. It shall be completely submersible. It shall be air or water jet self-cleaning and have the following minimum Range: 0-50,000 mg/l 0-5% Accuracy: +/- 5% of reading or +/- 100 mg/l, whichever is greater. Repeatability: +/- 1% of reading or +/- 20 mg/l whichever is greater. Pressure: 0-50 PSIG Cable Termination: Tinned Ends or JB-93 Junction Box with quick disconnect. Mounting: Brackets included to mount to Standard two inch Dia. handrail or as The Model 76A Medium Range In-Line Sensor:- The Model 76A Sensor shall contain the light source, photo detector, and self-cleaning actuator mechanism. It shall be self-cleaning with the following minimum Range: 0-30,000 mg/l 0-3% Accuracy: +/- 5% of reading or +/- 150 mg/l, whichever is greater. Repeatability: +/- 1% of reading or +/- 30 mg/l whichever is greater. Cable Termination: Tinned Ends orjb-93 Junction Box with quick disconnect. Mounting: Shall be into a pipe through a two inch female NPT saddle or similar arrangement provided by the installer. A two inch male NPT insertion nipple shall be provided as part of the sensor assembly. OPTIONAL JET CLEAN SELF-CLEANING SYSTEM All Royce Suspended Solids sensors can be supplied with an optional Jet self-cleaning system. This cleaning system can operate from plant air or water of at least 30 PSI with a maximum of 60 PSIG for Immersion sensors and 20 PSIG greater than line pressure for in-line sensors. Simply specify the Jet Self-Cleaning assembly. If plant

air or water is not available, Royce can supply a complete self-contained compressor package MODEL JCT. The solenoid shall be programmed by the Royce MODEL 7011A suspended solids analyzer to deliver an air or water jet blast across the sensor optics at timed intervals. Type: Air Compressor, light, non-continuous duty. Pressure Supplied: 40 to 60 PSIG. Temperature Limits: 0 to 50 o C. Enclosure: NEMA 4X, 14 x 12 x 6 D. Input Power: 115/230VAC, 60/50 Hz, 325 Watts. Options: Heater (Recommended for 10 o C). Mounting: Royce Rail Mounting Kit. CAUTION: The AIR JET CLEANING should NOT be used on In-Line applications where injecting air would be detrimental to the process. Sanitaire Royce Technologies 14125 South Bridge Circle Charlotte, NC 28273 800 347 3505 Tel 704 409 9898 Fax 704 409 9899 www.roycetechnologies.com European Office: London Asia - Pacific Office: Australia