Exit Stopper. STI-6400 Series

Similar documents
Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Installation and ZONES: Operation Manual. Model: ON STI-34108

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

STANDARD FEATURES SPECIFICATIONS

Stopper II Heated Enclosure

Illuminated Stopper Station Push Button

Stopper II SERIES ADA. We protect the things that protect you

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Child Resistant Pool Alarms

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

COMPANY PROFILE PROTECTING THE THINGS THAT PROTECT YOU

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

AED Alarm System Model Operations Manual

EVO192 v3.0 Fire and Burglary What s New

Installation Guide for models:

Independent Zone Control (I.Z.C.)

Installation Instructions

WM3000 WIRELESS MODULES

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

Gate Mount Pool Alarms

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for models:

4100U City and Relay Cards Installation Instructions

MANUAL RESET ALARM RELEASE

AL800ULADA. NAC Power Extender. Installation Guide

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Series. Access Power Controllers. Installation Guide

ANNUNCIATOR FIXED MODULE

TRX MAINS CONNECTION DIAGRAM

User Manual X8s Access Control System

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

MANUAL RESET ALARM RELEASE

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Go Smart. Go Wireless.

MODEL B2 INSTALLATION MANUAL

DE5300 Delayed Egress System. General Information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

ALARMED EXIT HARDWARE

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

KT-100 Door Controller

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Installation Instructions

Remote Display Alarm Indicator for Oxygen monitor

Alarmed Exit Hardware

General Purpose IO Technical Manual

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Wireless D.I.Y. Alarm Kit

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Remote Chexit Module (RCM) System. General Information

SMARTWALK DEMENTIA WANDERING SYSTEM

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

2-ZONE EASYFIT INTRUDER ALARM

Installation Instructions. CAR COMING Pedestrian Alert Safety Signs (PASS)

Model 5100A, 5200A, and 5100ALBV Owner s Manual

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Go Smart. Go Wireless.

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

DS160/DS161 Request To Exit PIR sensors Installation Instructions

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

SPECIFICATIONS. Contents List

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

NetworX NX-548E Receiver Installation Instructions

Carbon Monoxide Transmitter

Product Catalog. For specs & details go to sti-usa.com 1

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Model 4001 Series Single Channel Controller

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

MANUAL RESET ALARM RELEASE BOX

Pump-Up Controller MODEL 4062

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

Product Catalog. For specs & details go to sti-usa.com 1

Transcription:

Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be mounted on top, right, left or next to almost any door. User can select on-site whether to use an alarm or annunciator. Less expensive than heavy horizontal bar type units and practical for all emergency doors. Contact STI for custom applications. We Protect the Things that Protect You. - 1 -

Table of Contents Warnings and Cautions... Page 2 Warranty Information... Page 2 Specifications... Page 3 1. Dimensions... Page 3 2. Polycarbonate... Page 3 3. Electronics... Page 3 4. Remote Horn... Page 3 Circuit Board Set-Up... Page 4 Terminal Strip Layout... Page 4 Switch Settings... Page 4 Alarm Feature Description... Page 5 Installation Instructions All Units / STI-6400... Page 5 Mounting Options... Page 6 STI-6402 Double Door additional install notes... Page 7 STI-6403 Remote Horn additional install notes... Page 7 STI-6404 Double Door with Remote Horn additional install notes... Page 7 STI-6405 Exit Stopper with Momentary Reset... Page 7 Warnings All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three STI-6403 may be used in parallel. All specifications and information shown are current as of publication and subject to change without notice. Warranty Information Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14-2 -

Specifications Polycarbonate Enclosure: Dimensions 5.375 W x 5.375 H x 2 D (137mm x 137mm x 51mm) Flammability UL94 V-2 Wall Thickness 0.12 in (3.05mm) Electronics: STI-6400 - All Units Power Source Horn Volume at 1 ft. Relay Output Stand by Current Alarm Current Operating Temperature Range 9 VDC Alkaline or 9V-24VDC wired Class II UL Listed transformer 95 db low / 105 db high Form C Dry Contacts 0-30 VDC or VAC, 1 Amp 10uA 130mA at 95 db / 200mA at 105 db 32 to 113 F (0 to 45 C) Electronics: STI-6403 and STI-6404 - Remote Horn Unit Power Source 9 VDC operating power* only Horn Volume at 1 ft. 95 db low / 105 db high Stand by Current 0 A Alarm Current 50mA at 95 db/ 200 ma at 105 db * Power source for the STI-6403 Remote Horn uses a separate power source from the STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm. - 3 -

Circuit Board Set-up ALARM VOLUME SWITCH (ON) TRIP DELAY SWITCH (OFF) JP2 JP5 TERMINAL BLOCK ALARM DURATION SWITCH (OFF) (OFF) JP4 JP3 (FACTORY DEFAULT SETTINGS) ARMING SWITCH (ON) JP7 FORM C DRY CONTACTS REMOTE POWER INPUT 9-24 VDC REED SWITCH TERMINALS KEY SWITCH TERMINALS NC COM NO GD V+ RS1 RS2 KEYSW TERMINAL BLOCK WIRING CONNECTIONS Figure 1 Shipped with jumper installed (RS2). If using second reed switch, remove jumper and insert second switch. Switch Settings FEATURE JP2 JP3 JP4 JP5 JP7 Volume - POLYCARBONATE High (105 db) BASE at 1 ft. ON* Volume - Low (95 db) at 1 ft. OFF Duration - 30 Second Alarm OFF* OFF* Duration - 180 Second 120 db HORN Alarm OFF ON Duration - Continuous Alarm ON OFF Duration - Annunciator Mode ON ON Trip - Immediate POLYCARBONATE COVER Trip - 15 Second Delay Arming - Immediate Arming - 15 Second Delay OFF* ON ON* OFF *Factory Settings Note: Slide black lever to desired ON/OFF position as labeled on circuit board. - 4 -

KEYSW NC COM NO GD V+ RS1 RS2 KEYSW Alarm Feature Description Volume Switch JP2 - Sets alarm volume to high 105 db or low 95 db. Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at end of duration if door is closed. Alarm will not reset if in continuous mode; alarm sounds until battery is drained. Annunciator Mode is a series of 10 short beeps or until door is closed. Trip Delay Switch JP5 - If you wish to ENTER an alarmed door without sounding the horn immediately, the trip delay will allow 15 seconds for you to enter and de-activate the alarm with the key switch before the alarm will sound. Arming Switch JP7 - This mode is useful when an AUTHORIZED EXIT is required through alarmed door. In ON position immediate arming will set the alarm ready to function as soon as door is opened. In OFF position delay arming will allow 15 seconds for you to exit through the door without sending alarm signal. Installation Instructions Note: STI recommends setting up unit and testing settings prior to mounting. 1. Make sure key switch is in the OFF position. 2. Remove tamper screw on side of unit and remove housing cover. Save this tool for future servicing and battery change (Fig. 2). 3. Set switches, on circuit board, to desired alarm settings (Fig. 1). 4. Test settings by connecting battery or external power source. If using external power source a Class II UL Listed transformer is required. If power is present at terminal block (Fig. 1) 9V battery is in no-load on standby power consumption. 5. Mount main unit on or next to door using hardware provided. Reed switch mounting locations can be moved to one of the four positions shown in Fig. 2. If mounted next to door, route reed switch wire through knockout in bottom of housing as shown in Fig. 3. 6. Mount magnet on door frame (or door if unit is mounted next to door) using screws provided. When mounting on metal doors or door frames, use plastic spacers provided. Reed switch and magnet must be within 3/4 when door is closed (3/8 on metal door and frame). Please refer to figures 4, 5 and 6 on page 6 for other mounting options. 7. If installing STI-6402, STI-6403, or STI-6404 continue to page 7 for more instructions (Fig. 7 and 8). STI-6402 mounting option is shown on page 6. 8. Replace cover by sliding flanges on inside of cover into slots on base. Then rotate the cover over unit and snap close. Replace tamper screw. 19039 SCREW 6 x 1 1/4 in. - 5 - EMERGENCY USE ONLY ALARM SOUNDS WHEN DOOR IS OPENED ON OFF COVER REED SWITCH MOUNTING LOCATIONS (LABELED 1-4) FLANGES VIEW SHOWING MAGNET INSTALLATION COVER MAGNET 4 19014 MOUNTING SCREW (4) PROVIDED SLOTS 1 TERMINAL STRIP 9 VOLT BATTERY 2 19011 TAMPERPROOF SCREW (1) PROVIDED 3 19016 TAMPER WRENCH BASE (1) PROVIDED FLANGES REMOVE FRONT COVER AND ROUTE REED SWITCH WIRES THROUGH NOTCH ON BOTTOM SURFACE AS SHOWN MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOOR AND FRAME REED SWITCH MOUNTING LOCATIONS SPACERS (USE AS NECESSARY) NOTE: 2 SPACERS UNDER BOTH (LABELED MAGNET 1-4) AND REED SWITCH MUST BE USED ON STEEL DOORS 4 19018 ANCHOR Figure 2 Figure 3 19014 M (4) PROV

INSTALLATION 19039 SCREW Mounting 6 Options x 1 1/4 in. 19039 SCREW 6 x 1 1/4 in. MAGNET MUST BE INSTALLED OPPOSITE RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS TYPICAL FLUSH MOUNT DOOR JAM INSTALLATION 19018 ANCHOR MAGNET MAGNET MUST BE INSTALLED OPPOSITE 6400 UNIT RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS DOOR 19018 ANCHOR MAGNET SWING 6400 UNIT DOOR SWING JAM DOOR STOP DOOR JAM DOOR STOP DOOR Figure 4 TYPICAL RECESSED MOUNT DOOR JAM INSTALLATION MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) TYPICAL RECESSED MOUNT DOOR JAM INSTALLATION DOOR STOP MAGNET MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) 6400 SWING DOOR STOP 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME DOOR SWING MAGNET 6400 SWING *Note: When mounting reed switch on door and the main unit on wall, wire DOOR service loop must be used. SWING Figure 5 TYPICAL DOUBLE DOOR INSTALLATION STI-6402 INTERNAL REED SWITCH (RS1) - 6 -TO KEY SWITCH Figure 6

STI-6402 Double Door Install Notes 1. If not using extra reed switch, add jumper across two terminals of RS2 on terminal block. 2. Determine length needed for reed switch wires. STI provides 1 reed switch with 6 ft. wires. Cut to desired length. 3. Connect first reed switch in RS1 and second in RS2 (Fig. 7). (Refer to Fig. 1 for additional details on page 4.) *Note: Alarm will sound when either door is opened. TERMINAL BLOCK OPTIONAL: TO REMOTE HORN STI-6403 INTERNAL REED SWITCH (RS1) TO KEY SWITCH 06402 REED SWITCH (RS2) STI-6403 Remote Horn Install Notes VIEW SHOWING INSTALLATION OF ADDTIONAL REED SWITCH 06402 Figure 7 1. Remove cover. 2. Connect two conductor wire (14-24 AWG) from main unit terminal block pins COM and NO to remote horn unit terminal block. (wire not provided). Units can be set up to 300 ft. apart. Not polarity sensitive (refer to Fig. 1 and Fig. 7 for details). 3. Connect internal battery. 4. Mount similar to main unit with #8 x 1 in. screws and anchors if necessary. 5. Replace cover and screws. 6. Turn key switch to ON position. ROUTE WIRES THROUGH NOTCH KEY SWITCH *Note: The ON/OFF key position is opposite from 6400 main unit. Remote horn sounds when main unit alarm is activated. STI-6403 REMOTE HORN UNIT INSTALLATION STI-6404 Double Door with Remote Horn Install Notes The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation instructions for the main unit, the STI-6402 and the STI-6403 for complete installation. STI-6405 Exit Stopper with Momentary Reset The STI-6405 uses a momentary switch. After initial installation, unit is always on and you do not have to remember to turn it on when you leave a protected area. This model also eliminates having to remember to re-arm it because it is never off. Figure 8 When the alarm is triggered, to silence the alarm, insert the key and turn completely to the RESET position and hold for 2 seconds, then release. The switch will spring back to its original position and push the key out. To turn the unit off, supply power must be removed. RESET - 7 -

2306 Airport Rd Waterford, MI 48327 Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com Web: www.sti-europe.com Printed in USA Subject to change without notice. - 8 - Inst. 6400 FEB2014