FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Similar documents
FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT221, FDO221, FDT221

FDOOT241-A9-Ex Multisensor fire detector

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740-A9-Ex Multisensor fire detector

OH720, OP720, HI720, HI722

OOH740-A9-Ex Multi-sensor fire detector

ASA linear smoke detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OOH740, OOHC740 Automatic fire detectors

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output modules

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Multi line separator module

Input module, input/output module

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

DT1101A / DT1102A / DO110xA Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FDBZ290 Air sampling smoke detection kit

FDCL221-M Multi line separator module

Output module (230 V)

FDBZ290 Air sampling smoke detection kit

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Mimic display driver, LED ribbon cable

DM1131 / DM1133 / DM1134 Manual call points

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

SWING radio fire detection system

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Radio fire detection system

FDCIO223 (ES 45) Transponder

Test units and accessories

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FD20 Sinteso Detector system

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDCL221-Ex Line adapter (Ex)

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panel for modernization

Fire control panels FC360

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DF1101-Ex Infrared flame detector

FDOOT241-A9-Ex Automatic fire detector Technical Manual

Test units and accessories

Fire control panels FC726 FC726-XA

DF1151-Ex Infrared flame detector

Desigo Fire Safety intelligent detectors for complete safety

FC2020 Fire control panel

Test units and accessories

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

FDBZ290 Air sampling smoke detection kit Technical Manual

DC1192 Input /Output module

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FT2080 Fire terminal (Touch) Mounting Installation

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FDL241-9 Linear smoke detector Mounting Commissioning

FT2080 Fire terminal (Touch) Mounting Installation

FC723 Fire control panel

FC724 Fire control panel

FDA241, FDA221 Siemens ASD

FC724 Fire control panel

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

FC722 Fire control panel

FS20 Fire detection system

Fire & Security Products. Siemens Building Technologies Group

XC10 combined fire detection and extinguishing control

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

XC10 combined fire detection and extinguishing control

Intelligent Detection Devices

FC722 Fire control panel

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

FDCW241 Radio gateway Mounting

FDS229 Alarm sounder with supplementary optical indication Technical Manual

FDA241, FDA221 Siemens ASD

For internal use only. Distribution (please mark): Product Solution Multi-channel x

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Sinteso TM product catalog.

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Synova TM product catalog.

DOW1171 / DCW1151 Radio fire detection system

Sinteso fire detectors

FDM273 Radio manual call point Mounting

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Smoke Detector Testing

ARCHITECT AND ENGINEER SPECIFICATIONS

FDCL221 Line separator

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Call stations and extensions

Fire protection for emergency power supply

Room thermostat with 24-hour time switch and large LCD

FDL241-9 Linear smoke detector Technical Manual

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Borupvang Ballerup

Duct Air Quality Sensors

Transcription:

Sinteso S-LINE FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8 Multisensor fire detectors Multi-sensor fire detector for gradual modernization with ASAtechnology For the modernization of collective/gmt/synoline300, AlgoRex AnalogPLUS, and Interactive, SIGMALOOP, or MS8 on Sinteso FDnet Signal processing with ASAtechnology (Advanced Signal Analysis) Event-controlled detection behavior Early and reliable detection when fires occur Highly developed immunity to deceptive phenomena Maximum system availability thanks to sensory with redundancy Suitable for wind speeds of 1 20 m/s Ecological materials concept 2016-04-20 Control Products and Systems

Properties Ecological benefits: Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Environmentally friendly detector-testing without gas Features Resistant to environmental and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena Shock resistant, theft protection as an accessory Signal processing with ASAtechnology (Advanced Signal Analysis) Time and process-dependent detection behavior Proven immunity to faults in power electronics Protected electronics, high-quality components Sophisticated sensors and electronic monitoring Redundant, high-quality sensor system Internal alarm indicator (IAI), 360 visibility, alignment not necessary Integrated line separator Use Multi-sensor fire detector FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8 Multi-sensor fire detector consisting of: Point detector with additional heat sensors Detector dust cap to protect the point detector during the construction phase Function Functions according to the scattered light principle with two sensors, optical forward and backward scattering Opto-electronic measuring chamber, obstructs disruptive extraneous light but can be relied upon to detect both light and dark smoke particles Two additional heat sensors increase the fire detector's immunity to deceptive phenomena Can be set as a multi-sensor smoke detector, smoke detector, or heat detector by the software Selectable detection behavior thanks to application-specific ASA parameter sets Multi-protocol: Use FDOOT241-A3 (AlgoRex AnalogPLUS, FDnet) FDOOT241-A4 (SIGMALOOP, FDnet) FDOOT241-A5 (AlgoRex Interactive, FDnet) FDOOT241-A9: collective/gmt (Cerberus/Siemens)/SynoLINE300, FDnet FDOOT241-8 (MS8/PMT, FDnet) For early detection of flaming fires of solid and liquid substances as well as of smoldering fires For early and reliable fire detection in an environment with deceptive phenomena Can be used addressed, for the gradual modernization of: AlgoRex AnalogPLUS on Sinteso FDnet ¹ ) with FDOOT241-A3 SIGMALOOP on Sinteso FDnet ¹ ) with FDOOT241-A4 AlgoRex Interactive on Sinteso FDnet ¹ ) with FDOOT241-A5 Collective/GMT/SynoLINE300 on Sinteso FDnet ¹ ) with FDOOT241-A9 MS8/PMT on Sinteso FDnet with FDOOT241-8 ¹ ) FS20 compatibility in FDnet is assured subject to in-country FS20 software support. 2

Type Overview Type Order no. Designation Weight [kg] Point detector FDOOT241-A3 S54310-F10-A1 Multi-sensor fire detector Sinteso (A+) 0.106 FDOOT241-A4 S54310-F9-A1 Multi-sensor fire detector Sinteso (SIGMA) 0.106 FDOOT241-A5 S54310-F14-A1 Multi-sensor fire detector Sinteso (Interactive) 0.106 FDOOT241-A9 S54310-F11-A1 Multi-sensor fire detector Sinteso ASA 0.106 FDOOT241-8 A5Q00004663 Multi-sensor smoke detector Sinteso ASA 0.106 Migration kits FDOOT241-8M A5Q00016038 Migration kit (FDOOT241-8 + FDB281) 0.235 FDOOT241-8B A5Q00015956 Migration kit (FDOOT241-8 + FDB221) 0.162 Base adapter FDB241 S54319-F13-A1 Base adapter Sinteso (SIGMA/A+) 0.086 FDB251 S54319-F28-A1 Base adapter Sinteso (Interactive) 0,090 FDB281 A5Q00004929 Base adapter MS8/PMT 0.125 FDB299 S54319-F14-A1 Base adapter Sinteso (AlgoRex coll.) 0.086 Other accessories FDUD290 S54370-S13-A1 Removal tool for adapter 0.098 You will find information about the color options for the fire detectors in the data sheet 009409. 3

Accessories Base adapter FDB241 Function: For adapting AnalogPLUS and SIGMALOOP for Sinteso detector systems Can be set with jumper on replaced detector Base adapter FDB251 Function: For adapting Interactive for Sinteso detector systems Can be set with jumper on replaced detector Base adapter FDB281 Function: For adapting MS8/PMT for Sinteso detector systems 4

Base adapter FDB299 Function: For adapting AlgoRex (collective) and SIGMACON for Sinteso detector systems Removal tool for adapter FDUD290 Function: For removing base adapters FDB2xx with detector exchanger, detector exchanger and tester, or detector tester Notes Efficiency on-site No wiring, detector replacement only Detectors can be replaced without a ladder at heights up to 8 m with the detector exchanger FDUD291, detector exchanger and tester FDUD292, or intelligent detector tester FDUD293 in combination with telescope or extension rod. 5

Installation 3 6 1 2 2 5 4 1 Base adapter 2 Point detector 3 Detector base 4 Detector exchanger/detector exchanger and tester FDB241 FDOOT241-A3 AnalogPLUS (DB1131) FDOOT241-A4 SIGMALOOP (SPF3600) FDB251 FDOOT241-A5 Interactive (DB1151A) FDB299 FDOOT241-A9 AlgoRex collective (DB1101A)/ SIGMACON (SPF600) FDB281 FDOOT241-8 6 MS8 (Z84) FDUD291 FDUD292 FDUD293 5 IAI Internal alarm indicator 1. Screw the point detector into the base adapter. 2. Screw the point detector with the attached base adapter into the detector base by hand or with a detector exchanger or detector exchanger and tester. a The point detector is mounted. 6

Technical data Operating voltage (modulated) Operating current (quiescent) External alarm indicators (AI) which can be connected Communication protocol System compatibility Operating temperature Storage temperature Humidity Color Protection category (IEC 60529) with detector base FDB221, FDB222 Base attachment FDB291 Base adapter FDB281 Base adapter FDB241 and detector base DB1131A, or SPF3600 Base adapter FDB251 and detector base FDOOT241-A3 FDOOT241-A4 FDOOT241-A5 FDOOT241-A9 FDOOT241-8 In the AnalogPLUS detector system In the SIGMALOOP detector system In the Interactive detector system In the collective detector system In the MS8 detector system FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9 FDOOT241-8 In FDnet DC 16 28 V DC 10 28 V DC 21 33 V DC 14 28 V DC 14 28 V DC 12 33 V 190 μa 200 μa 200 μa 65 125 μa 200 μa 190 230 μa 2 2 2 2 2 2 AnalogPLUS SIGMALOOP Interactive Collective MS8/PMT FDnet AlgoRex SIGMASYS AlgoRex AlgoRex, SIGMASYS, CZ10 SIGMASYS, BMS, SM80/88/ D100, SRS -25 +70 C -25 +70 C -25 +70 C -35 +70 C -25 +70 C - -30 +75 C -30 +75 C -30 +75 C -35 +75 C -30 +75 C - 95 % rel. ~RAL 9010 pure white IP43 IP44 IP44 IP44 IP44 FS20¹ ) 7

DB1151A Base adapter FDB299 and collective detector base DB1101A or SDF600 FDOOT241-A3 FDOOT241-A4 FDOOT241-A5 FDOOT241-A9 FDOOT241-8 IP44 Standards CEA 4021, EN 54-5, EN 54-7, EN 54-17 Approvals VdS LPCB Permissible wind speed G211125 126bh/02 G212007 - G215057 126bh/07 1 20 m/s G212036 126bh/03 G204133 - FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9 FDOOT241-8 - - ¹ ) FS20 compatibility in FDnet is assured subject to in-country FS20 software support. Dimensional drawing a b Combination Detector base AnalogPLUS (DB1131A) Base adapter FDB241 Multi-sensor fire detector FDOOT241-A3 Detector base AnalogPLUS (SPF3600) Base adapter FDB241 Multi-sensor fire detector FDOOT241-A4 Collective detector base (DB1101A or SFP600) Base adapter FDB299 Multi-sensor fire detector FDOOT241-A9 Detector base Interactive (DB1151A) Base adapter FDB251 Multi-sensor fire detector FDOOT241-A5 Detector base MS8 Base adapter FDB281 Multi-sensor smoke detector FDOOT241-8 Dimension 'a' Dimension 'b' with detector base Dimension 'b' without detector base 117 77.9 73.3 91.4 73.5 8

Applicable documents Document ID Title 008331 List of compatibility (for 'Sinteso ' product line) 008164 Equipment overview Sinteso Detector system FD20 007004 Technical manual Automatic fire detectors FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 A6V10323158 A6V10301452 A6V10411361 Technical manual Modernizing fire detection installations with multiple protocol detectors Installation Base adapter FDB241 Installation Base adapter FDB251 008116 Installation Base adapter FDB281 A6V10301448 Installation Base adapter FDB299 009409 Data sheet Colored detectors, bases and base attachment FDO.., FDOOT, FDT, FDB 11 12 15 12 07 0786 FDOOT241-A3 Siemens Switzerland Ltd, Gubelstrasse 22 Technical data: see doc. 007004 FDOOT241-A3 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21128; DoC No.: CED-FDOOT241-A3 0786 FDOOT241-A4 Siemens Switzerland Ltd, Gubelstrasse 22 Technical data: see doc. 007004 FDOOT241-A4 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21138; DoC No.: CED-FDOOT241-A4 0832 FDOOT241-A5 Siemens Switzerland Ltd, Gubelstrasse 22 Technical data: see doc. 007004 FDOOT241-A5 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0832-CPR-F0893; DoC No.: CED-FDOOT241-A5 0786 FDOOT241-A9 Siemens Switzerland Ltd, Gubelstrasse 22 Technical data: see doc. 007004 FDOOT241-A9 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21155; DoC No.: CED-FDOOT241-A9 0786 FDOOT241-8 Siemens Switzerland Ltd, Gubelstrasse 22 Technical data: see doc. 007004 FDOOT241-8 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20008; DoC No.: CED-FDOOT241-8 9

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2012 Technical specifications and availability subject to change without notice. 10 Document ID Manual FD20 Edition 2016-04-20 Register 2