Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: ALARM DEVICE MANUFACTURING CO.

Similar documents
SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SECURITY SYSTEM NOTES

NetworX NX-8V2. LED Keypad User Manual

HILLS Series LED Code Pad User Manual

NETWORX TM. User manual NX-4

NX-148 LCD CODE PAD TABLE OF CONTENTS

NetworX Series NX-1500E LED Keypad

LED Keypads D720 Series User s Guide

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

ADEMCO 4110XM SECURITY SYSTEM. User Guide. N5100V5 4/99 Rev. C

Panic. Part Number SYSTEMS, Inc.

Table of Contents. Page Code

INSTRUCTION MANUAL PC255O

D1265. User's Guide. Touchscreen Keypad

INSTRUCTION MANUAL PC255O

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Using your LED Plus keypad

LYNX Security System 8VHU V0DQXDO. ALPHA DRAFT June 5, 1998 N8891 5/98 OFF AWAY STAY AUX

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

User's Manual VIA-30PSE, VISTA-10SE. N7229V2 Rev C. 5/02

Technical Manuals Online! - USER'S MANUAL

MOOSE MPI 50 CONTROL PANNEL

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

User's Manual 5120XM N8031 6/96

Technical Manuals Online! - K4855V1 3/00 FA560 3 STAY B 1 OFF 2 AWAY 6 C D 5 TEST 9 CHIME # 8 CODE I I I I I I READY ARMED MAX

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

VISTA-50P VISTA-50PUL

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

636 and 646 Keypads. User s Manual

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Security System. User Guide for the LED Command Center

VISTA-20SE/VISTA-20HWSE

USING DEVICE COMMANDS

Wireless Security System

Digiplex LED Keypads User s Manual

DS7446KP. User Guide. Keypad

6HFXULW\6\VWHP 8VHU*XLGH N8891V2 6/99

How to Use Your Sentrol Security System

U ser's Guide PC6010

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

XL-20. Security System. Owner s Manual N /97

Security System. User s Guide for the Text Command Center

Safewatch Pro 3000 System Manual

HILLS Series LCD Code Pad User Manual

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

User's Manual VISTA-40 N7003V1 6/97

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

L900 series USER MANUAL

6HFXULW\6\VWHP 8VHU*XLGH 9HUVLRQ. Technical Manuals Online! - N /98

DS7080i Version 2+ Security System User s Guide An instruction guide For your alarm system when used with a DS7447, DS7443S or DS7445 keypad

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Smoke Alarm User Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Smoke Alarm User s Manual

Destiny Destiny Owners Manual

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

User's Manual. Safewatch Pro. N7229 6V1 Rev B 4/99

NX148-E LCD KEYPAD TABLE OF CONTENTS

IDS816 User Manual H Issued January 2009

LED Indication of Zone Status, A.C. Power and Alarm Memory (indicates alarm has taken place and bel I has timed off).

HMS MODEL 925 OWNER'S MANUAL

9,67$ 6(D 6\VWHP 6HFXULW\ 86(5 *8,'( N7229AUV2 12/99

DS7400Xi (version 3+) Security System User s Guide

A. Introduction: 1. Six burglary zones, an emergency zone, and a fire zone... all fully supervised two wire zones with end-ofline

Silencing an Alarm All/Perimeter Home/Away Systems Area Systems

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Using Your XP-600. Security System NAPCO NAPCO 2006 OI301B 4/06 1

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Tomorrow s technology for today s security needs.

XTL/XTLN/XTLN-WiFi USER GUIDE

HMS MODEL 800 Owner s Manual

Using Your GEM-P800 Security System

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

XRSuper6. User s Guide

AXI LED USER MANUAL (REV. 1.0)

ADEMCO VISTA SERIES User Guide

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

XTL Series USER GUIDE

Security System. User s Guide

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Contents. Glossary

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

DESTINY OWNER S MANUAL

How to Use Your Sentrol Security System

Total Connect Box. User manual

/10 Rev A

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Transcription:

Your Ademco LogiCenter Fir&Burglar Alarm System i INTRODUCTION: Your LogiCenter is designed to alert you in the event of either a forced entry into a protected area or signal an alarm if a fire alarm condition exists. The burglar alarm section of the LogiCenter provides for six zones of operation. This enables the installation to be separated into six areas of protection. Four can be used for either interior or perimeter protection or simply to zone the system, should you desire to eliminate part of your protection for some reason. In addition, your LogiCenter has two delay zones, which enable you to enter and exit without having to control the system by using an outdoor remote control. When all of your protective devices are closed (doors, windows, etc.), the red status light on your LogiCenter and your remote station will FLASH SLOWLY and no zone lights will be lit on your LogiCenter. If one of these devices is open, the status light will not be ON and, once the local keyswitch is in SYSTEM: CHECKIRESm position, at least one of your LogiCenter zone indicators will be lit. You should, therefore, not attempt to arm your.system unless you correct the open condition or bypass the zone that has an open protective device. Once the system is armed, should any of these protective units open, your alarm sounding device will turn on. To silence your sounding device, once it s gone into alarm, you must either disarmyour system from your local or remote station or, in the event of a panic alarm, the local keyswitch located in the LogiCenter must be turned to SYSTEM: CHECK/RESET. (See Silencing The Alarm ). The fire alarm circuitry in the LogiCenter: on the other hand, operates in a different fashion. The detectors in the fire alarm circuit are open normally and closed during an alarm condition. However, supervision is still maintained at all times since a measured current is being passed through the circuit at all,times and a signal will be initiated should a wire break in this particular circuit. The fire atarm portion of the system operates on a 24-hour basis. There is no way to turn this circuit off. Therefore, you are fully protected around the clock should a fire occur. In order to easily distinguish between a burglary condition and a fire condition, the LogiCenter provides for two entirely separate circuits. One set of terminals is connected to a bell to alert you that there is either a burglary or panic condition existing. A separate siren is wired to the fire signaling terminals and will only sound during a fire alarm condition. Since the bell sounds only for burglary or panic and the siren for only fire, you can immediately determine the nature of the alarm. instead of using a separate bell for burglary or panic and a siren for fire, your system can provide for two distinctly different sounds using one siren for signaling purposes. This capability allows the siren to produce a slowly pulsating sound for burglary or panic and a rapidly pulsating sound for a fire alarm condition. Therefore, if the siren slowly pulsates, you know that either a burglar) or panic situation exists. If the siren rapidly pulsates, you know that the fire alarm signaling ALARM DEVICE MANUFACTURING CO. A DIVISION OF PITTWAY CORPORATION 165 Eileen Wabp. Syosset, New York 11791 P8189 REV.A 9/83 Copyright 8 1981 PITTWAY CORPORATION 603

circuit has been activated. Check with. your installer to make certain that you understand which type of signaling system you have installed. HOW TO OPERATE?OUR ADEMCO SECURITY SYSTEM: ARMING THE SYSTEM: The burglar alarm circuit of your Ademco Security System may be operated from indoor remote control stations ck locally from the LogiCenter. Indoor remote stations have a red status light and either a pushbutton, a momentary key operated switch lock, or digital keypad (requiring a correct number combination). The latter also has a buzzer. RED STATUS FLASHING SiOWLY (System OFF): When all windows and doors being monitored by Ademco intrusion detectors are closed and all inside trap protection devices (such as under-the-carpet mats, photoelectric beams, and motion detectors) are operating properly, the red SYSTEM STATUS lamp on all remote control stations and on the LogiCenter will be FLASHING SLOWLY. This indicates that the security system is OFF but ready for arming. (If the lamp is OFF, one or more of the protective circuits is open.) If a buzzer is also pulsating slowly it is indicative that an alarm had occured during the just ended ARMED period and that the zone lights on the LogiCenter shouldbecheckedforthesourceofthealarm. RED STATUS LIGHT ON.STEADY (System 0.N): The system may be turned on at a remote station by momentarily depressing a button, turning a keyswitch or by pushing the proper combination of numbers (on a remote digital keypad) or at the LogiCenter by turning a keyswitch momentarily to ARM/ DISARM. The SYSTEM STATUS light on your remote station or on your LogiCenter will stay ON solidly. If the system was successfully armed and the AUTOMATIC BELL TEST option was selected (see TESTING PROCEDURES), a 2 second sound will be produced by the alarm sounder immediately, as a sounder test,and a H second sound will be produced at the end of the exit delay period. If any intrusion detector or trap device is now tripped, an immediate alarm will sound. DISARMING THE SYSTEMi The system may be turned OFF at a remote station by momentarily depressing a button, turning a keyswitch or bxis 604 LOCAL CONTROL STATION OUTDOOR REMOTE CONTROL STATION (AdemcoNo~.245,245Ror5245) DIGITAL REMOTE CONTROL STATION (AdemcoNos.2l5or2l5-12) --

pushing the proper combination of numbers (on a remote digital keypad) or at the LogiCenter by turning a keyswitch. Under normal conditions, the SYSTEM STATUS light should go from solidly ON to FLASHING. A slowly pulsating buzzer sound, at a remote digital keypad or at the LogiCenter and a flashing SYSTEM STATUS light indicates that an alarm has occurred since the system was armed. Leave immediately and return with police protection, as the intruder may still be inside. At that time, the source of the alarm may be determined from the zone lights on the LogiCenter. SILENCING THE ALARM: 1. 2 If a burglar alarm occurs, bells, horns or sirens may be silenced by switching any remote station OFF. Depress the push button, turn the keyswitch, or enter the keyed disarm code at any remote station or turn the keyswitch momentarily to ARM/DISARM at the LogiCenter so that the red light is FLASHING. If the alarm continues to sound, a fire or panic alarm has occurred. Turn the keyswitch at the LogiCenter to SYSTEM: CHECK/RESET. If a fire alarm occurs, determine and respond to the cause of the alarm and then go to the LogiCenter. Depress the SMOKE DETECTOR RESET switch and turn the keyswitch momentarily to SYSTEM: CHECK/RESET. INSTRUCTIONS FOR LEAVING: 1. Go to an indoor remote control station or to your LogiCenter and make sure the red SYSTEM STATUS light is FLASHING SLOWLY. If it is FLASHING SLOWLY, you may arm your system and leave the premises. If it is OFF, one or more of the protective circuits is not ready for arming. Turn the LogiCenter keyswitch to SYS- TEM: CHECK/RESET. The circuit indicator(s) for the faulted circuit(s) will light and the buzzer will sound. If the SYSTEM STATUS indicator is ignored and the LogiCenter is armed with a circuit faulted, a 10 second buzzer sound will be pro- duced, providing time to disarm the system prior to an alarm. Make sure all doors and windows are closed properly. Check to see if furniture is blocking a motion detector or is sitting on top of an undarthe-carpet mat. If the problem cannot be 616 SMOKE DETECTOR URCUIT RESET SWITCH BYPASS SWITCHES rectified and it is desired to arm the system with the problem circuit(s) bypassed, turn the keyswitch at the. LogiCenter to SYS- TEM: CHECK/RESET and set the ON/OFF switches for the problem circuit(s) to OFF. Restore the keyswitch to the center position. 2. Arm the system at an indoor remote control station or at the LogiCenter so that the red SYSTEM STATUS light is ON. If arming is done with one or more circuits bypassed, the buzzers in the LogiCenter and in the remote digital keypad (if applicable) will sound a 2 second warning prior to commencing the exit period sounding. You now must leave the premises and shut the exit door before the exit time delay expires (Check with your local Ademco dealer to find out the exact length of the exit delay period). 605

INSTRUCTIONS FOR ENTERING: Enter the premises, go immediately,to.an indoor remote station and switch it to ttie OFF position or to the LogiCenter and momentarily switch it to the ARM/DISARM position (red SYSTEM STATUS light FLASH- SPECIAL OPTIONAL FEATURES: AUTOMATIC ALARM SHUTOFF: Shuts off the burglar alarm system 10 or 30 minutes after an alarm occurs. Be sure to check an inside remote station or the LogiCenter after entering the premises. If an alarm has taken place the remote station s red light may not be lit or the LogiCenter s zone status indicator(s) may be lit. Turn the LogiCenter s keyswitch to SYSTEM: CHECK/RESET to determine the current status of the protective circuits. Make sure the entry door is closed. Locate the detector that has been tripped and put it into operating condition. The remote station/logicenter red SYSTEM STATUS light(s) should now FLASH SLOWLY. ENTRY/EXIT DELAY DISABLE SWITCH: The LogiCenter may have a special switch located inside the locked cabinet or located remotely. This switch makes it possible to disable the entry/exit delay when the premises are occupied and to enable that delay when the premises are left vacant. Detectors protecting doors on the entry/exit zone normally trip an alarm after a delay when the system is ON, permitting the system to be armed and the premises to be vacated or the system to be disarmed subsequent to entry without causing an alarm. Operation of the switch allows the delay to be disabled so that entry via a door while the system is armed and you are in residence causes an instant alarm. Check with your local Ademco dealer for further details. TESTING PROCEDURES: BURGLAR ALARM: Arm the system at a remote station or at the LogiCenter. Open and then close an exit door. Wait approximately 2 minutes to make certain that the alarm does not sound. Open the door again (the entry delay warning device will sound as soon as the door is opened this second time) and wait until the preset entry delay time period has passed. The alarm should now sound. Turn the alarm OFF by disarming the system at a remote station Or at the LogiCenter. 617 ING). This must be done before the entry de& time has elapsed, otherwise the, alarm will sound (Check with your local Ademco dealer to determine the exact length of the entry delay period). ENTRY DELAY WARNING DNlCE (Ademco No. 706 or 70612 Mini-Howler) ENTRY/EXIT DELAY DISABLE SWITCH (Ademco No. 259) PANIC (EMERGENCY) BUTTON (Ademco No. 219) 606

PANIC ALARM: Depress a panic (emergency) button. The alarm should sound. Reset the alarm by turning the keyswitch located in the LogiCenter cabinet to SYSTEM: CHECWRESR: BELL AND STANDBY BATTrRY (OPTIONAL): If you have permitted your installer to enable the AUTOMATIC BELL TEST option built-in to every LogiCenter, the alarm sounder should produce a sound of 2 seconds duration each time the system is armed. If the alarm does not sound, it is an indication that the battery is not supplying the alarm sounder with adequate current. Either the battery is defective or the battery charging circuit is defective. Contact your local.ademco dealer immediately. This test should be conducted once a week to make sure that the system is operating properly. FIRE ALARM: Operate the FIRE TEST switch located behind the door on the right side of the LogiCenter. The alarm should sound. Release the switch. The alarm should continue to sound. Reset the alarm by turning the LogiCenter keyswitch momentarily to SYSTEM: CHECK/RESET. If the alarm does not sound, contact your local Ademco dealer immediately. This fire test should be conducted once a week to make sure that the system is operating properly. STANDBY BATTERY: Remove the securing screw and pull out the system s plug-in transformer with the system armed. The AC lamp on the Center s front panel should go OUT, but the system should continue to function with the red SYSTEM STATUS lamps on all remote stations and on the LogiCenter NOTE: FIRE TEST SWITCH RECHARGEABLE BAITERY PACK kfemt?o No. 499 for Model 4080 Ademco No. 930 lor Model 408042 ON. The LogiCenter s warning buzzer should sound. Replace the plug-in transformer in its socket. The AC lamp should be back ON and the sounder should be silenced as soon as the keyswitch is turned momentarily to SYSTEM:CHECK/RESET. After each alarm condition, the system should be tested in order to make certain that all circuits are operating. SERVICING INFORMATION: Your local Ademco dealer is the man best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable. Your local Ademco dealer is: A few service functions, however, may be handled directly by you: 1. STANDBY BATTERIES: The LogiCenter uses a rechargeable battery pack which normally need not be replaced for at least 607 618

5 years. The TESTING PROCEDURES described above tell how to check its condition. If a test fails, contact your local Ademco dealer immediately 2. ADEMCO MODEL 622/623 SMOKE DETECTORS OR MODEi632H COMBUS- TlON DETECTORS should be cleaned at least yearly, or more often if in areas that are dusty or exposed to small insects. Clean the Model 6221623 Smoke Detectors by unsnapping the plastic cap and by passing the nozzle of a vacuum cleaner over the detection chamber. Clean the Model 632H Combustion Detectors by passing the nozzle of a vacuum cleaner over the detector s side slots. 3. THE A.C. POWER LAMP on the front of the cabinet should be lit at all times indicating that the system is operating from AC power. If this lamp goes out, it may be an indication that the AC supply is interrupted or a trouble condition is present. The LogiCenter s warning buzzer will sound. If this occurs, check your house circuit fuse or circuit breaker. *If remedial action there does not correct the problem, call your Ademco dealer. 4. THE FIRE TROUBLE SOUNDER pulsating rapidly and the SYSTEM STATLJS indicator FLASHING RAPIDLY denote a broken wire in the fire circuit or interrupted power to smoke detector(s). The buzzer is silenced by moving the LogiCenter s fire alarm NORMAUTROUBLE switch to the TROUBLE position and by momentarily turning the keyswitch to the SYSTEM: CHECK/RESET position. Contact your local Ademco dealer immediately. EMERGENCY EVACUATION PLAN: TIIERYOSTAT Wemco Nos. 601 or 661A) SMOKE DETECTOR (Ademco Nos. 6226.622-12.623-6 or 62342) COMBUSTION DETECTOR (Ademco Nos. 632H or 632H12) FIRE TROUBLE SWITCH AC. POWER LAMP An emergency evacuation plan should be established for an actual fire alarm condition. For EXAMPLES example, the following steps are recommended by the National Fire Protection Association and j-z-jg-j can. be used as a guide in establishing this plan for homes. Similar plans may be made for commercial establishments. 1. Determine two means of escape from each bedroom. One will be the door leading to the normal exit from the house. The other ~@*gfq _ 7 may be a window that opens easily. An 619 181 FLOOR 600

escape ladder may have to be located near the window if there is a long drop to the ground below. 2. Draw up a floor plan of your home. Show windows, doors, stairs, and rooftops that can be used for escape. Indicate each family member s escape routes. Always keep these routes free from obstruction. 3. Set a meeting place outdoors for a head count of family members. 4. Practice escape procedures. Sleep with the bedroom door closed. It will increase your escape time. If you suspect fire, test the door. If it is hot, don t open it-the hall is already too hot to enter. If you think it s safe, brace your shoulder against the door and open it cautiously. Be ready to slam the door if smoke or heat rush in. Practice escaping to the outdoors and meeting at an assigned spot. Call the fire department from a neighbor s phone. 2nd FLOOR SOME TIPS ON RESIDENTIAL FIRE PROTECTION: Since most fires in a home occur at night when or if they are located in different sections of the evef.yone is asleep, the ideal location for a smoke house, one smoke detector should be placed near detector is between the bedroom area and the each of these sleeping areas. rest of the house. If the bedrooms are spread out (Cont. On Next Pagr ATTENTION, RESIDENTIAL SYSTEM OWNERS! f- HOMEOWNER S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner s insurance carrier for possible premium credit (The Ademco No. 4080 LogiCenter is Underwriters Laboratories Listed for Household Combination Fire and Burglary use). A. GENERAL INFORMATION: Insured s Name and Address: Insurance Company: Policy No.: Ademco Control Model No.: Type of Alarm: 0 Burglary 0 Fire IJ Both Installed by: Name Serviced by: Name Address Address B. NOTIFIES (Insert B = Burglary, F = Fire) Local Sounding Device: Police Dept.: Fire Dept.: Central Station: Name and Address:

In multi-level houses one smoke detector may be sufficient to protect an entire floor. Since smoke rises, a stairwell in a home tends to become a natural chimney for smoke rising frdm ohe level to the next. Therefore, by locating a smoke detector near the top of the stairs leading to a main sleeping area, all bedrooms can be successfully protected using a minimum of units. Locating a smoke detector outside a particular bedroom will not protect the occupants of that room should a fire originate there. It may be.advisable, therefore, to locate a smoke detector in each bedroom. In general, early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household 4s follows: A smoke detector installed in each separate sleeping area (the vicinity of, but outside of the bedrooms), and heat or smoke detectors in living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages. NOTE: After the installation of your alarm system has been completed, notify your local fire department to give them your name and address for their records. 1 DINING 4 KITCHEN IBEDROOM BU)ROOM 1 I?k @BELL CONTROL LIVING ROOM BEDROOM BEST RESlDENTlAL DETECTOR PLACEMENT: BETWEEN BEDROOMS and REST OF HOUSE PLACE DETECTOR MAXIMUM DETECTORS NEAR AU SLEEPING AREAS I _ FLOOR COVERAGE- AT TOP OF STAIRWELLS =SMOKE DETECTOR C. POWERED BY: AC. With Rechargeable Power Supply D. TESTING: [J Quarterly 0 Monthly fj Weekly 0 Other E. SMOKE AND HEAT DETECTOR LOCATIONS (Insert S = Smoke, H = Heat) Furnace Area -, Kitchen -, Bedrooms -, Attic -, Basement -1 Living Room -, Dining Room -, Hall - F. BURGLARY DETECTING DEVICE LOCATIONS: 0 Front Door c] Basement Door IJ Rear Door 0 All Exterior Doors 0 1 st Floor Windows 0 All Windows 0 All Accessible Openings, Including Skylights, Air Conditioners and Vents IJ Interior Locations G. ADDITIONAL PERTINENT INFORMATION: Signature: Date: I;ADEMC~J ALARM DEVICE MANUFACTURING COMPANY 165 Eileen Way, Syosset, New York 11791