False Alarm Suppression in Early Prediction of Cardiac Arrhythmia

Similar documents
Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Alarms That Deserve Attention. Mike Rayo 3/29/2016

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Battery Performance Alert

HOLTER RECORDER Product parameters

Application Note. Application Note for BAYEX

Clinical Alarm Management Strategies Meaningful Alerts

Benefits of Enhanced Event Analysis in. Mark Miller

VASHON-MAURY FIRE AND RESCUE Community Needs Survey Executive Summary March 2000

Video Smoke Detection using Deep Domain Adaptation Enhanced with Synthetic Smoke Images

T1 BEDSIDE MONITOR GUIDELINE

Applied Data Science: Using Machine Learning for Alarm Verification

"It's Alarming Simple Steps To Reduce Nuisance Alarms

You finally make it home after a long shift, shower,

Security Management System - Configuring Video Analytics

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Carbon Monoxide Alarm Response Guide. High Country Training Center Training On Demand

Real time Video Fire Detection using Spatio-Temporal Consistency Energy

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

GE Healthcare. Dash Variable-Acuity Monitoring

Research Article Footstep and Vehicle Detection Using Seismic Sensors in Wireless Sensor Network: Field Tests

Managing Clinical Alarms

Person Detection Techniques for an Internet of Things(IoT)-Based Emergency Evacuation System

Performance Neuro-Fuzzy for Power System Fault Location

Intrusion Detection System: Facts, Challenges and Futures. By Gina Tjhai 13 th March 2007 Network Research Group

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Fire Detection Using Image Processing

White Paper: Video/Audio Analysis Technology. hanwhasecurity.com

Seeing and Responding to Signals

Crop Management Details Start from Parameters settings Emergence Planting Seed brand: Settings Parameter settings Hybrid-specific Generic

Improving rail network velocity: A machine learning approach to predictive maintenance

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

Performance Evaluation of Event Detection Solutions: the CREDS experience

Fire Department Anchorage: Performance. Value. Results.

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

Force Protection Joint Experiment (FPJE) Battlefield Anti-Intrusion System (BAIS) Sensors Data Analysis and Filtering Metrics

HIn3550 Magnetic Field Monitor User's Manual

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Urban Water Security Research Alliance Technical Report No. 91. SEQ Residential Water End Use Study: Validation Trial of CSIRO End Use Sensor

Alarm System Performance Metrics

2013 Compliance Report RCW 52.33

Diagnostics with fieldbus

TOP R4 Unknown Operating State

Why Clinical Alarms are a TOP TEN Hazard

ACTIVE ACOUSTIC METHODOLOGY FOR DETECTING SEWER LINE OBSTRUCTIONS

C-NRPP Quality Assurance Guidance for Radon Test Devices

2. Regarding the Withdrawal of ISO/IEEE Projects from the TC 215 Program of Work

Full Wave Imaging of Downhole Microseismic; using all the data

An Alarm Correlation Algorithm for Network Management Based on Root Cause Analysis

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

EVACUATION MODELING DEPENDENCE ON INPUT PARAMETERS

Setting the new standard for personal radiation detection.

A temporal active fire detection algorithm applied to geostationary satellite observations

Customizing Alarm Limits Based on Specific Needs of Patients

Presented at 6 th Pipeline Technology Conference Hannover, Germany April 4-5, 2011

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Alarm Management Services

Patient Alarm Messages

Applying Functional Safety Engineering Technique to Optimize Defensive Fire Protection Strategy

Measure Lifetime Derived from a Field Study of Age at Replacement

Dangerous Assumptions

Improved occupancy detection accuracy using PIR and door sensors for a smart thermostat

Sensor Systems Network Design and QA/QC Brian Stacey

SELECTION AND PERFORMANCE ASSESSMENT OF AUTOMATED PATIENT MONITORING SYSTEMS FOR THE JOHNS HOPKINS ADULT INTENSIVE CARE UNITS

Cent$ible Power Users Manual

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

Session Ten Achieving Compliance in Hardware Fault Tolerance

Evaluation of the Red Jacket Fx1, Fx2, Fx1V and Fx2V Line Leak Detectors For Hourly Monitoring on Rigid Pipelines. Final Report

The Evolution of DOE Emergency Services. Patrick Smith ORO Lead General Engineer

Reliability and Safety Assessment in Offshore and Process Industries

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

E. Elnahrawy, X. Li, and R. Martin

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

Optical Time Domain Reflectometry for the OMEGA EP Laser

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

U.S. Fire Department Profile 2015

Radar technology in surveillance

2017 Annual Report. King County Fire District No. 27 Fall City, WA

Inconsistencies in terminology and definitions of organic soil materials

Avirup Sil and Alexander Yates (Temple University) Ernest Cronin, Penghai Nie, Yinfei Yang (St. Joseph s University) Ana-Maria Popescu (Yahoo!

PALM BEACH GARDENS FIRE RESCUE

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

EXECUTIVE SUMMARY FOR OCCUPANT BEHAVIOR, EGRESS, AND EMERGENCY COMMUNICATIONS

EVALUATION OF SENSYS WIRELESS DETECTION SYSTEM: YEAR-AFTER EVALUATION AND OFF-CENTER SENSORS

HeartStart XL+ User Training Workbook. Model No

Bringing Smarts to Methane Emissions Detection

KEYWORDS: Smart fire detection, fire signatures, nuisance sources, non-fire signatures

Fire Investigation

Machine Diagnostics in Observer 9 Standard Rules

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Hazardous Material Safety Program

6 th Pipeline Technology Conference 2011

National Certificate in Fire and Rescue Services Airport (Level 3)

Alarm Safety in 2017:

Alarm Analysis with Fuzzy Logic and Multilevel Flow Models

Evaluation of the Incon TS-LLD Line Leak Detection System

Transcription:

IEEE International Conference on Bioinformatics & Bioengineering 2015 False Alarm Suppression in Early Prediction of Cardiac Arrhythmia Shoumik Roychoudhury, Mohamed F. Ghalwash, Zoran Obradovic Presented by: Zoran Obradovic zoran.obradovic@temple.edu Center for Data Analytics and Biomedical Informatics 1

Introduction Alarm fatigue among care providers inside ICUs due to the high percentages of bedside monitor false alarms, has been identified as one of the top 10 medical hazards. Alarm fatigue results in desensitization among care providers, which ultimately can lead to lower standards of care to patients and also result in fatal consequences. 2

Introduction Goals Suppress high false alarm rates from bedside monitors in intensive care units. Improve the response time of the medical personnel in the event of lifethreatening arrhythmia alarms by providing early prediction of alarms. Reduce alarm fatigue among care providers by early false alarm suppression. Objective Develop a cost-sensitive prediction model to suppress false alarms while keeping true alarm detection rates high. Build a model for early prediction of alarm events. 3

Contribution Provide more accurate prediction (high true alarm detection and false alarm suppression) than the state-of-the-art methods on arrhythmia alarms. Provide interpretable results in order to explain the rationale of the prediction, whereas all other published methods are black-box. Provide early prediction before the alarm happens, which helps practitioners respond earlier. Provide a cost-sensitive model to achieve the desired level of false alarm suppression rate. 4

Early prediction of time series The main objective is to predict the label of the time series as the signal is progressively recorded and before the alarm event occurs. Example: Red signal represents a True alarm signal. 20-second analysis window prior to the alarm is considered. The alarm occurs at the 21 st second. The observed window below represents 20 seconds prior to the alarm. 5

EDSC (Xing et al. 2011) Interpretable early classification model (EDSC) extracts local discriminative patterns (shapelets) from the time series in order to characterize the target class. Black marks indicate the algorithm is reading an unknown time series. 6

EDSC Interpretable early classification model (EDSC) extracts local discriminative patterns (shapelets) from the time series to characterize the target class. Blue shapelet S is a good match at time step 4. It is extracted during the learning phase and is identified as a characteristic pattern for a false alarm event. 7

EDSC Interpretable early classification model (EDSC) extracts local discriminative patterns (shapelets) from the time series in order to characterize the target class. The red signal is misclassified as a blue class at time step 4. 8

Drawbacks of EDSC Signals from different classes may be similar to each other in early phases. Extracted shapelets might have similar pattern which can lead to wrong predictions. e.g. a true alarm signal might match a false alarm shapelet. EDSC method lacks uncertainty (confidence) estimation of predicted labels. 9

MEDSC-U (Ghalwash et al. 2013) MUDSC-U extends EDSC to produce interpretable early classification of time series with uncertainty estimates. The uncertainty for the matched subsequence (distance measurement) is computed. MEDSC-U computes low confidence for a blue shapelet match. 10

MEDSC-U 11

1-MEDSCU

Learning Phase Shapelets (in black) from true alarm (red) and false alarm (blue) Classes.

Experiments: Data and Setup ECG lead II data Setup Two types of critical arrhythmia alarm datasets from MIMIC II version 3 repository. Asystole (ASYS) Ventricular tachycardia (VTACH) Dataset Total alarms True alarms(%) False alarms(%) ASYS 261 40(15.3%) 221(84.7%) VTACH 629 227(36.09%) 402(63.91%) True alarms are randomly partitioned into 4 disjoint groups of N/4 examples. N/4 false alarms are randomly selected for each of 4 groups. All methods (the proposed and the baseline methods) are trained using 2 groups (N/2 true and N/2 false alarms) and tested on the remaining 2 examples. This is repeated 20 times 14

Experiments: Measures and Baselines

TAD Vs. FAS Objective: Achieve high FAS (X-axis) while keeping near 100% TAD (Y-axis). Increasing value in X-axis indicates high false alarm suppression and increasing value in Y-axis indicates high true alarm detection. The markings indicate performance of each model for both TAD and FAS The upper right hand corner in the figure is the ideal result (100 % FAS and 100 % TAD). The proposed method (red circle) outperforms all baseline methods in terms of TAD in both datasets. Baseline methods are better in terms of FAS however they make lot of false negative errors.

Controlling False Alarm Suppression Rate Baseline methods are rigid in terms of true alarm detection and false alarm suppression (red and blue marks). 1-MEDSCU has a configurable framework where users can set-up a desired TAD rate (dashed red line) by controlling the false alarm confidence threshold (x-axis). The blue dotted line is the varying false alarm suppression. e.g 1-MEDSCU can achieve a 68% false alarm suppression (blue arrow) by dropping the true alarm detection rate to 90% (red arrow) in case of ASYS alarms. Varying false alarm confidence threshold for ASYS 17

Weighted balanced accuracy (WAcc) 18

Earliness 1-MEDSCU provides earlier predictions than Behar et al., but EDSC predicts even earlier. We report 100-earliness (Larger the better). Dataset Behar(Raw) Behar(Filtered) EDSC 1-MEDSCU ASYS 0 0 62.8±6.27 38.39±9.05 VTACH 0 0 59.9±11.71 39.96±9.34 However, 1-MEDSCU is a configurable model, we can improve the earliness by varying the false alarm confidence threshold. End users have the option of choosing their desired level of earliness. Figure shows how earliness is improved for lower values of false alarm confidence threshold. 1-MEDSCU can predict earlier than EDSC when false alarm confidence threshold is smaller than 20%. 100- Earliness values for varying false alarm confidence threshold for ASYS 19

Interpretability 1-MEDSCU is an interpretable method, thus domain experts can visually verify the actual reason for false or true alarms. The exact time of the pattern can also be identified. Domain experts prefer such methods compared to black-box classification methods. The true alarm is wrongly classified as a false alarm by EDSC at time 4. It is correctly classified as a true alarm by 1-MEDSCU at time 16. 20

Summary We were able to achieve a moderate percentage of FAS while keeping high rate of early TAD predictions. The proposed approach has outperformed the state-of-the-art methods in terms of weighted accuracy. We can achieve higher FAS rates by sacrificing TAD rate. In addition, the proposed method provides not only accurate results but also interpretable and early. Future work Currently, 1-MEDSCU works for univariate time series only. We will extend it to multivariate time series in order to improve the performance of the model. We will also investigate the problem of false alarm suppression in other medical domains. 21

Thank you 22