MHC On-Line Instrumentation

Similar documents
MHC Series Sensors

Dryer Controller M720

Industrial Grade Gas Detection Detecting The Difference

OVEN INDUSTRIES, INC.

Technical data sheet TDS0060

Frequently asked questions: Intelligent Transmitter Series

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

User Manual. Dryer Controller M720

ESSEX ENGINEERING CORPORATION

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

OPERATING MANUAL Enertronic Control System 2

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Analog Input Module IC670ALG630

XP95 Sounder VAD Base

EasyLog Data Logger Series

C-Bus Four Channel Analogue Output Unit Installation Instructions

Model 1062 Environment Monitor

Technical data sheet TDS0034

Tachometer/Hourmeter/Trip. Installation and Operation Manual

DS7400Xi Addressable Control/ Communicator

TER Active Room Temperature Sensor (Controller),

MTDPC. (also known as MTPC) INSTALLATION AND OPERATION MANUAL MultiTrode Pump Controller

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Advanced HART Diagnostic Suite

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

DTM Distributed Transmitter-Monitor

EasyLog Data Logger Series

Model 7700 Pump Director Valve and Pump Motor Interface Controller

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Carbon Monoxide Transmitter

Intelligent addressable fire alarm control panel

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

intelligent fire alarm ID60series panels

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Table of Contents SECTION PAGE

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

FDA241, FDA221 Siemens ASD

IntelliPack : 800 Series

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Installation, Operating and Maintenance Manual

Sentry G3 Machinery Protection Monitor

Product Data Sheet. Remote Terminals. Features:

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Instruction VIBROCONTROL 850. Single channel vibration monitor. Keep it accessible for future reference.

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

B-40/B-41 Modulating Temperature Controller

Sentry G3 Machinery Protection Monitor

C-Bus Four Channel General Input Unit Installation Instructions

H&O DIE SUPPLY, INC SPR-2000-JR. Programmable Fluid Controller Interstate 20 Kennedale, TX 76060

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Flostop TS D7E and A8E. Operation Manual

BC-4000 Bilge Monitor/Controller Installation Manual

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Instructions for the fan motor control system, SILVER C

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

Products and systems

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Flair 500 Series Annunciators

EOTec 2C32 Installation Guide

20 Light Remote Annunciator

Intelligent Security & Fire Ltd

Touchpoint Pro Flexible Gas Control System

ID50series. intelligent fire alarm panels

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

HAA2866 HAA2866 ERRATUM

Process Alarm Solutions

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Universal Gas Detector

The EN54 Part 2 & 4 Fire System

Nov 08 PRODUCT SPECIFICATION SHEET

System 57. An advanced World of intelligent gas detection system management

continuous emissions monitoring Combustion & Environmental Monitoring

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MODEL 5100 VOTING LOGIC MODULE

APPLICATION DATA SHEET

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Intelligent Single Loop Fire Alarm Control Panel

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

DOLKPS1KB Programming & Installation Manual

Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Vigilant MX4428 Fire Alarm System

OPERATING MANUAL Enertronic Control System 2

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

AS950 PORTABLE SAMPLERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PREMIER PLATINUM INFRARED GAS SENSOR

Transcription:

Direct Connection of MHC 2000 and 3000 Sensors Permanent Monitoring of up 16 Sensors per Instrument Proven in Over 10 years of Industrial Application Kittiwake Holroyd Ltd A Kittiwake Group Company

The MHC-Point is a versatile condition monitoring module that takes the signal from 2000 and 3000 series MHC sensors, providing continuous surveillance of your critical rotating machinery based on unique and patented AE technology. In this way, the ever vigilant MHC-Point is able to provide an early indication of a wide range of machine faults without the need for detailed design information, shaft speeds or bearing ISO numbers. It can be used as either a standalone unit or an intelligent interface to your existing SCADA and PLC systems. Signals from up to 16 MHC Sensors can be fed to a single node MHC-Node. The signal from one or more MHC-Nodes can be fed to a permanently installed MHC Point where the signal is processed in to a format compatable with your SCADA or other PLC system. Two versions are available MHC Point/Std or MHC-Point/Slo. MHC-Point/Std systems are the most common and designed for monitoring shaft speeds above about 30 rpm. MHC-Point/Slo systems incorporate unique MHC technology and specifically designed for very slow moving or rotating systems with speed from 60 to 0.25 rpm. Note that permanently installed MHC sensors and instruments come in 2000 and 3000 series. The difference between these two series is the supply voltage being 10V DC for 2000 series and 24V DC for 3000 series. One MHC-Point can monitor up to 16 2000/3000 series sensors via MHC Node. What can MHC - Point Detect? The versatile outputs and unique detection technology at the heart of the MHC-Point allows limitless application possibilities to most rotating machinery. Examples include: Lubrication Condition - alert when lubrication is inadequate (eg lack of grease or water/particulate contamination, seal failure) Use as part of an intelligent greasing system Bearing Condition - provide early warning when journal, ball and roller bearings start to deteriorate Provide warning of rapid failure modes to minimise secondary damage Gearbox Condition - provide early warning of gearbox degradation (shaft bearings and gear teeth wear) What Machinery does the MHC-Point Monitor? MHC-Point/Std The MHC-Point/Std is capable of monitoring virtually any rotating piece of equipment down to approximately 35 rpm, without knowing anything about the detailed design of the machinery (e.g. rpm, bearing ISO number, previous history etc). Fans (air cond, extraction, blowers etc). Motors (fixed and variable speed) Pumps (centrifugal, screw, lobe etc). Gearboxes & pulley drive systems Bearings (plain, ball, roller etc). MHC-Point/Slo The MHC-Point/Slo is capable of monitoring virtually any rotating piece of equipment rotating at speeds from 60 rpm down to 0.25 rpm without knowing anything about the detailed design of the machinery. This capability to monitor very slow rotational speeds in a unique attribute of AE technology, complimenting and extending the range of any existing limitation monitoring programme. Low speed drives Shaft/drum/roll support bearings Turntable bearings, Slew rings, Cranes Settling tank scrapers, Tank agitators Rotating kilns and lots more.

Key Features Dual Intelligent Alarms Designate criteria for each on Distress, db level or both. Programmable set-points and time delays (alarm hold-off). Manual reset (remote contact closure) or automatic. Handheld MHC Point/Programmer (MHC - PP) Gives security to set-up, Displays current values, Trending. Smart Logging Saves processed values for the last 128 days. Optional memory freeze on alarm, non-volatile memory. No need to reset or re-configure after power interruption. External disable so only logs when machine is running. LED indication of alarm and power status. Versatile Outputs Switched NPN transistor for relays, PLC / SCADA systems etc. Analogue for SCADA / PC (two available, one externally selectable). Built-in AE Sensor Excitation Lost Signal Alarm Faulty sensor wiring when signal drops below a defined limit. Adaptable Sensor Options MHC compatible, 50 ohm phantom drive, standard, waterproof and submersible sensors, structure borne or airborne detection, special sensor options also available. About the MHC-Point Technology MHC-Point has internal non-volatile memory storing the processed signal characterisations for the last 128 days (Distress and db Level for MHC-Point/Std and db Level, Peak, Intensity & Extent for MHC-Point/Slo). Each reading represents the most significant value that the machine generated in each 24 hours of operation. Logging can be on a First In First Out basis or can be automatically frozen whenever an alarm condition is met. The critical trends of the pertinent signal characterisations over the last 128 days are instantly available to be viewed on the Point Programmer (MHC-PP) at any time. In addition, the internal status of an MHC-Point is unaffected by interruptions to the power supply. When power is restored, the MHC-Point carries on from where it left off; same alarm set-points and time delay, same alarm status, same logger memory contents etc. MHC-Point units come with two switching outputs which have independent settings so that two severity levels can be set (e.g. one as warning and the other as an alarm for action). The set-points for each of these ouputs is independent and can operate on an individual signal characterisation or all characterisatons simultaneously (using an OR function). as in the example below for MHC-Point/Std: Alarm Function MHC-Point/Std Alarm Function MHC-Point/Slo Alarm if value > Distress set-point value Alarm if value > db Level set-point value > db Level set-point value > Peak set-point value > Alarm time delay (hold-off) > Intensity set-point value > Extent set-point value > Alarm time delay (hold-off) In the example shown, the alarm state (lower trace) only changes when 10 consecutive values for Distress or db Level exceed the alarm level, thereby ignoring transient activity. The alarm function of MHC-Point/Slo operates in a similar way but on its db Level, Peak, Intensity and Extent signal characterisations. An additional feature unique to the MHC-Point/ Std is a Low Signal Level alarm which is activated if the db Level falls and stays below 5 db for 24 hours. In this way short term power interruptions are ignored but attention is drawn to long term drops in signal due to cable damage etc. This feature can be inhibited if not required.

MHC-Point - Technical Specifications Outputs Alarm Outputs : 2 qty. NPN transistor outputs - current sinking (1.6V @ full 0.1A DC load current) with manual or automatic reset Alarm O/P s 1 & 2 : MHC-Point/Std operates on Distress & db Level with optional low db level alarm when signal level < 5dB. MHC-Point/Slo operates on db Level, Peak, Intensity & Extent Analogue Outputs : 0 to +2 VDC (max) scaled at 19.5 mv / unit updated every measurement cycle (10 secs for MHC-Point/Std and 9 machine revolutions for MHC-Point/Slo Analogue O/P1 : MHC-Point/Std default is Distress MHC-Point/Slo default is Intensity (MPX changes to db Level) Analogue O/P2 : MHC-Point/Std default is db Level MHC-Point/Slo default is Extent (MPX changes to Peak) Option to toggle analogue ouputs via hardwired MPX multiplex feature Point Programmer interface (15 pin D type) Internal Logging Continuous logging with option to freeze in alarmed state Stores processed max values of signal characteristics in each 24 hour period of continuous operation 128 sets of max values values stored in non-volatile FIFO memory Set-Up Primarily via Point Programmer (MHC-PP) Programmable (non-volatile) switching set-points (0 to 99) Programmable (non-volatile) time delay & alarm hold-off (0 to 255 readings) Hardwired external reset & disable Hardwired external switching of signal characterisation on analogue outputs (MPX) Internal 20 db gain reduction Inputs AE Sensor input - MHC compatible 10 VDC sensor excitation on /2000 series variants, 50 ohm impedance. 24 VDC phantom drive on /3000 series variants Physical Mounting Electrical Dimensions (mm) 110 (l) x 75 (h) x 50 (w) Front panel screw terminal connections for inputs, ouputs & power supply DIN46277-2, DIN46277-3 rail or wall/panel +24 VDC @ 50 ma (typical with outputs unloaded) from a low noise power supply (< 40mV pk-pk ripple & noise) MHC-Point Programmer (MHC-PP) The MHC-Point Programmer is the user s interface to the MHC-Point. It allows the MHC- Point to be tailored to the specific requirements of the operator and provides a means to access stored values of Distress and db Level. It also provides a level of anti-tampering as no unauthorized changes to the operation of the MHC-Point can be made without it. Using the MHC-PP for viewing and programming is easy using the built-in keypad to respond to the menus displayed on the LCD alphanumeric display. Alarms are transistor output (NPN) and can be reset with the MHC-PP, remote contact closure (e.g. manual reset button) or automatically, using pre-programmed reset timing. Importantly, with just one MHC-PP you can set-up and interrogate any number of MHC- Set Point Instruments MHC - Point Programmer (MHC-PP) I/O socket : Display : Keypad : Power Source : Physical (sizes in mm) : 15 pin D type connector LCD, 2 x 16 alphanumeric characters 4 button (Up, Down, Menu/Cancel, OK) Drawn from MHC-SetPoint Size 190(l) x 110(w) x 32(h) Sensors Suitable for 2000 and 3000 series MHC Sensors in permanent installation (non-interchangeable)

Set Up of an MHC-Point Setting up MHC-Point units couldn t be easier since the internal memory automatically stores the maximum values of the singal. Intelligent alarms can then be simply set with knowledge of the values associated with normal running and the programmable time delay (i.e. alarm hold-off to prevent false alarms), ensuring it only alerts to sustained changes in machine condition. These sophisticated alarms have independently programmed set points and switching criteria based on parameter combinations. To prevent tampering with the MHC-Point settings, all of the programmable features can only be modified through the Point Programmer (MHC-PP) since there are no other interfaces on the main unit front panel. Analogue outputs of the processed signal characteristics are also provided to allow simple interfacing to SCADA, PC or dedicated data acquisition systems. How does the MHC-Point work? MHC-Point units operate unsupervised in a stanadalone mode where machinery is continuously checked for deterioration. A typical setup is shown below in the uppermost schematic where the user requires alarms for early and late failures and optional displays of signal characteriations (Distress and db Level in the example shown which is for the MHC-Point/Std). When the alarm is activated by the MHC-Point unit use the MHC-PP to instantly review the trend of readings over the last 128 days. The MHC-Point will also operate in conjunction with standard PLC, SCADA & PC based data collection systems. To reduce the cost of processing multiple analogue channels, MHC-Point units can, if required, mulitplex analogue ouputs (MHC-Points /Std : Distress & db Level on Analogue 1, MHC-Point/Slo : Intensity or db Level on Analogue 1 and Extent or Peak on Analogue 2) to reduce the number of A to D converter channels required. In the second example, shown in the lower schematic, the user has opted to use the MHC-Point/Std to interface to a control system to take not only live readings of machine condition (through a single analogue port so that it can be sampled by a single ADC) but also to give local alarms of machine condition via dedicated relays (alarm outputs 1 & 2). Wide dynamic range circuitry, diffuse field detection and proprietary signal processing methods combine to make the MHC approach second to none. Whilst no CM technique can guarantee to provide early warning of all possible fault conditions, the patented MHC approach has an exceptional track record on all types of rotating machinery. High frequency Acoustic Emission (AE) signals are detected and processed to characterise both transient activity (Distress, Peak, Intensity and Extent parameters) and overall magnitude (db Level parameter). Signal levels are strongly affected by machinery fault processes including friction and impacts. In general rotating machinery in very good condition produces minimal transient activity (resulting in Distress and Extent values less than 5) and an increase in Distress or Extent is often the first sign of problems (e.g. from increased impacts due to poor lubrication or damaged surface condition). The power of the Distress and Extent parameters lies not only in their extreme sensitivity to developing faults, but also in their direct and near universal interpretation across rotating machinery. Since it does this without the need for empirically derived look-up tables or calculated defect frequency information, it provides a less ambiguous monitoring parameter than competitive methods. db Level provides a useful means of detecting more continuous activity associated with both accumulated damage and increased friction within moving parts. Peak and Intensity add further to the interpretation at slow rotational speeds (MHC-Point/Slo only).

Related products MHC-2000 and MHC-3000 series AE Sensors Spares and Accessories About Kittiwake Holroyd Ltd Holroyd are part of the Kittiwake group of companies. If your business is about condition monitoring of machinery, maintenance of industrial fuels and lubricants or monitoring of exhaust gases then Kittiwake operate in your field of expertise. Established in 1993, Kittiwake has grown into a leading global provider of monitoring and testing technology solutions with offices in the UK, Germany, India, USA, and Asia. Innovative technology solutions that make a real difference to your operations. Have a look at our information center on www.condition-monitoring.com for hints and tips on how to maximize the benefits from your maintenance budget. Kittiwake Holroyd Ltd Via Gellia Mills Matlock Derbyshire DE4 2AJ Tel: +44 (0)1629 822060 Fax: +44 (0)1629 823516 sales@kittiwakeholroyd.com www.kittiwakeholroyd.com