Project 4: Active Fire Protection Systems Issues. Project 4: Investigation Team

Similar documents
Fire Protection Coffee Break Training May 2016

Extreme Fires!

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

2012 B.C. Building Code Compliance Review (Division B Part 3)

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Floor Warden Training

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

University of Maryland FIRE EVACUATION PLAN

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

NFPA 101 SAF-AXM PUBLIC COMMENTS

Risk Management Services

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Building Fire Safety in New York City s Existing Office Buildings

NFPA 45 NFPA 211 NFPA 1600

OVERVIEW. Increasing Awareness of Occupant Evacuation in Tall Buildings. Traditional Focus has been on Evacuation From Fire

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

Statue of Liberty: A Risk Analysis

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

FIRE SAFETY PLAN FIRST & JASPER JASPER AVENUE

ICC CODE CORNER 2012 IFC Code & Commentary

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

CHAPTER 7 ALTERATIONS LEVEL

FIRE SAFETY INSPECTION REPORT

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Engineering Systems an Incremental Response to Terrorist Threat

RL 7 Integrate and evaluate content presented in diverse media and formats, including visually and quantitatively, as well as in words.

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Murray State University Building Coordinator Emergency Procedures. Hollis Franklin College

FIRE SAFETY INSPECTION REPORT

Richard B. Alpert, P.E. Senior FPE, Clark Nexsen

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

World Trade Center Evacuations

Fire Safety in Tall Building: Performance-Based Solutions. Chris Jelenewicz, P.E., FSFPE

The project scope work is 90% new construction and 10% remodel in Esslinger Hall.

Fire Alarm and Mass Notification Project

ADMINISTRATIVE SERVICES MANUAL

rpsa FIRE PROTECTION ENGINEERS

Fire Protection Coffee Break Training August 2016

Agency for Health Care Administration

RAMBLER PARK FIRE SAFETY INFORMATION

PERFORMANCE COMPLIANCE METHODS

Full Service Central Station Fire Alarm Listing Evaluation

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

Moving Target: A Case Study in Providing Fire Protection Below a Reconfigurable Concert Hall Seating System. Part 1: Concept Design

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

FIRE SAFETY INSPECTION REPORT

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80

Written Fire Safety Plans

FIRE SAFETY INSPECTION REPORT

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

NTSP 2005 International Telecommunications Safety Conference St. Louis, Missouri September 13-15, 2005

Fire protection for buildings

Emergency Evacuation Plan. Tiffany Tower Plot W2 Jumeirah Lakes Towers

January 1, 2014 Mandatory Effective Date

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Deputy Assistant Secretary Indian Affairs (Management)

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

Following are the systems proposed as per NBC & Local Fire Authority:

Common Building Code Misinterpretations

Agency for Health Care Administration

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

FIRE SAFETY INSPECTION REPORT

Hospital Fire Alarm Systems Recurring Misapplications and Misused Requirements

FIRE SAFETY INSPECTION REPORT

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

Q-0751 Principles of Building Construction Resources

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

FIRE AND FIRE FITTING By Mr. Prashant Sansare

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

Report on First Revisions with Statement June 2014 NFPA 101

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Emergency Guidelines Part II. North Campus

Setting A Standard on Fire Safety in Laboratories

NFPA 25 and the Influence of Liability

FIRE SAFETY PRACTICES AND PROCEDURES

EMERGENCY PROCEDURES FLIP CHART

Session VI Smart safety systems

2010 FIRE CODE OF NEW YORK STATE

INSPECTOR I SKILLS ADMINISTRATION

TRAINED CROWD MANAGER VENUE SPECIFIC TRAINING CURRICULUM OUTLINE

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler Heads Revised

Fire Hazard Analysis of Technical Area 53 Building 1

Agency for Health Care Administration

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

Transcription:

NIST World Trade Center Investigation Project 4: Active Fire Protection Systems Issues William Grosshandler Presenting Project 4: Investigation Team David D. Evans, Project 4 Leader W. Stuart Dols, M.E., NIST Erica D. Kuligowski, FPE, NIST Stephen M. Hill, FPE, P.E., ATF Edward K. Budnick, FPE, P.E., Hughes Associates Raymond A. Grill, FPE, P.E., Rolf Jensen Associates Michael J. Ferreira, FPE, P.E., Hughes Associates

Disclaimer Certain commercial entities, equipment, products, or materials are identified in this presentation in order to describe a procedure or concept adequately or to trace the history of the procedures and practices used. Such identification is not intended to imply recommendation, endorsement, or implication that the entities, products, materials, or equipment are necessarily the best available for the purpose.

OUTLINE Four issues and supporting findings from investigation of active fire protection systems in WTC 1, 2, and 7 All tall buildings and selected other buildings (1) The minimum level of performance for active fire protection systems. (2) The quantity and reliability of information available to first responders at the fire and emergency command center.

All tall buildings OUTLINE (continued) (3) Adequacy of information provided by Fire Alarm Systems for management of emergency response and evacuation. (4) Survival of fire alarm system and other building status records of events for investigation purposes, either through offsite transmission or on-site "black box."

ISSUE 1 The minimum level of performance for active fire protection systems in all tall buildings and selected other buildings. Findings The Fire Sprinkler Systems design method for WTC 1, 2, and 7 was based on the occupancy hazard fire control approach from NFPA 13, Standard for the Installation of Sprinkler Systems. The minimum water spray density and minimum design area of operation were based on a "Light Hazard" occupancy classification. Light Hazard is normally used for office spaces in most buildings.

ISSUE 1 Occupancy Hazard Class and Minimum Design Area Hazard Light Ordinary Group 1 Ordinary Group 2 Extra Group 1 Extra Group 2 Examples offices, data processing facilities, clubs and restaurant seating areas, commercial shops manufacturing and processing plants, laundries, and restaurant service areas dry cleaners, library stack areas, post office, and repair garages metal extruding and plywood and particleboard manufacturing plants containing little or no flammable and combustible liquids flammable liquid spray booths, open oil quenching areas containing moderate to substantial amounts of flammable or combustible liquids or having areas where combustibles were shielded from spray Density / Minimum Area 0.1 gpm/ft 2 / 1500 ft 2 0.15 gpm/ft 2 / 1500 ft 2 0.2 gpm/ft 2 / 1500 ft 2 0.3 gpm/ft 2 / 2500 ft 2 0.4 gpm/ft 2 / 2500 ft 2 Source: NFPA 13, Standard for the Installation of Sprinkler Systems

ISSUE 1 Additional underlying assumptions for sprinkler system design: Fires will involve ordinary office materials and will start in relatively small areas (i.e., < 1500 ft 2 ). Only one fire in the building. Finding The installed fire sprinkler systems in WTC 1, 2, and 7 exceeded minimum NFPA requirements.

ISSUE 1 Factors that could influence selection of sprinkler design area/density, but not explicitly considered in common design practice for office buildings, include threat profile, total area and height of the building, compartmentation, population in the building, prohibited activities and fuel loads in the building, excessive fire department response time, and acts of terrorism. Industrial/special facilities may consider some or all of above as part of loss-risk profile to base decisions for protection.

ISSUE 1 Level of performance includes factors such as System design basis Automatic vs. manual operation Redundancy Survivability Single point vulnerability for system failure

ISSUE 1 Automatic vs. Manual Operation Findings Fire sprinkler systems in WTC 1, 2, and 7 were automatic from water tank supplies but depended on manually operated pumps or fire department connections for continued operation. Fire alarm systems in WTC 1 and 2 provided for automatic fire detection, but required manual activation of notification devices. WTC 7 system provided automatic detection and notification. Smoke purge systems in WTC 1, 2 and 7 were manually initiated.

ISSUE 1 Single Point Vulnerability for System Failure Findings WTC 1, 2, and 7 fire sprinkler and standpipe systems were vulnerable to single point failures. WTC 1 and 2 fire alarm system voice notification, fire warden telephones, and fire fighter telephones were vulnerable to single point failures.

ISSUE 1 Single point failures: Sprinkler riser Sprinkler floor control assembly (typ.) Standpipe

ISSUE 1 AUDIO RISER TELEPHONE RISER XNET RISER MNET RISER Audio and telephone communications risers in one location: Single point failure possible Alarm system communications separated into different stairways: Separated but within core STAIR C FIRE ALARM CLOSET SPRINK./ JANITOR CLOSET STAIR B STAIR A

ISSUE 2 Adequacy of information (continuity, reliability, accuracy, sufficiency) provided by fire alarm and communications systems for management of emergency response and evacuation. Findings WTC 1 had overwhelming number of alarms registered and displayed (scrolling) at fire command station (FCS). No information was available at fire command station in WTC 1 about water supply in areas that were burning. One PANYNJ person was sent up to assess situation. In WTC 1, fire and other automatic alarm information at the FCS was not used to manage evacuation.

(Continued) ISSUE 2 Findings Alarm systems in WTC 1, 2, and 7 were only capable of determining and displaying (a) areas that had at some time reached alarm point conditions and (b) areas that had not. There was no means at the FCS to determine whether or not announcements made in WTC 1 and 2 reached and could be heard on intended floors.

ISSUE 3 Transmission of fire alarm and building systems information outside the building to enhance situational awareness of first responders and to aid in response decisions during emergencies. Findings The alarm system in WTC 1 and 2 was monitored by PANYNJ. No information from WTC 1 and 2 alarm system was available outside of the building.

Findings ISSUE 4 Survival of fire alarm system and other building status records of events for investigation purposes, either through off-site transmission or on-site "black box." Alarm systems collect information that is valuable for understanding the fire and smoke development in a building. The extensive back-up command capabilities and hardware installed in WTC 1 and 2 provided multiple places in the building where some alarm history data were stored. Up to 13 locations have been identified.

NCC LEVEL 108 (MER) MXL-VR 800 EVENT MEMORY LEVEL 108 (MER) MXL-VR 800 EVENT MEMORY ISSUE 4 LEVEL 75 (MER) LEVEL 41 (MER) MXL-VR 800 EVENT MEMORY MXL-VR 800 EVENT MEMORY LEVEL 75 (MER) LEVEL 41 (MER) MXL-VR 800 EVENT MEMORY MXL-VR 800 EVENT MEMORY Thirteen alarm system memory location and capacity in WTC 1 and 2 LEVEL 7 (MER) MXL-VR 800 EVENT MEMORY LEVEL 7 (MER) MXL-VR 800 EVENT MEMORY 800 event memory chip (typ.) [Automatic recycle] TOWER 1 TOWER 2 CONCOURSE SUBGRADE FCS RFCS RFCS RFCS MXLV MXLV TOWER 1 LOBBY FCS NCC MXLV NCC MXLV NCC TOWER 2 FCS MXLV NCC TOWER 2 LOBBY FCS CONCOURSE SUBGRADE FCS FCS 120 MB MEMORY IN EACH NCC 120 MB MEMORY IN EACH NCC MXLV NCC MXLV NCC 120 MB Hard Disk (typ.) [Automatic recycle] OCC B1 LEVEL WTC 4 WTC 5 TOWER 1 TOWER 2 CONCOURSE SUBGRADE RFCS RFCS RFCS RFCS RFCS RFCS MXLV NCC MXLV NCC MXLV NCC MXLV NCC MXLV NCC MXLV NCC 120 MB MEMORY IN EACH NCC LEVEL B6 MXL-VR 800 EVENT MEMORY LEVEL B6 MXL-VR 800 EVENT MEMORY

ISSUE 4 Survival of fire alarm system and other building status records Findings WTC 7 alarm system recorded information at one location: the Fire Command Station in the 3 rd floor lobby. WTC 7 Fire Alarm System was monitored offsite, but provided only one piece of information -- a fire alarm was triggered in the building. No information from the fire alarm system was recovered. No indication was found that anyone looked for it.

ISSUE 4 Monitoring station history tape record for the WTC 7 fire alarm system on September 11, 2001 09/11/01 14:48:22 DYJ 4612 **** FULL CLEAR **** 09/11/01 14:47:22 LATE 3923 SYSTEM TEST OVER 09/11/01 14:47:22 COMMENT: TEST: ALL 09/11/01 14:47:21 COMMENT: LAST SET: 091101 64742 09/11/01 10:00:52 1 1510 CO TO CLASS E AREA:1 *T 09/11/01 06;47:43 COMMENT: RIC: WILLIAMS 09/11/01 06:47:03 RIC 4210 PLACE ON TEST CAT:11 09/11/01 06:47:03 COMMENT: 091101 647 091101 1447 09/11/01 06:47:02 COMMENT: TEST: ALL 09/11/01 06:05:01 RP 20 TIMER TEST Note: Area: 1 = Building WTC 7 *T = System on TEST

ISSUE 4 Survival of fire alarm system and other building status records of events for investigation purposes Findings Survivability of alarm systems data on computer hard drives, memory modules, or printouts in building fire and collapse environments ( Black Box capabilities) is not addressed in present installation standards. Transmission of critical data outside building to monitoring station would provide one means to preserve event data. Although modern systems are capable of this communication, it is not done in practice.

NIST WTC Investigation Web Site http://wtc.nist.gov Thank You