AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems

Similar documents
TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

Flow Control for Fire Protection

Flow Control for Fire Protection

AGF Manufacturing Inc.

Model 5100A, 5200A, and 5100ALBV Owner s Manual

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Technical Data. Installation

GRUNDFOS FIRE PUMP SYSTEMS PEERLESS ENGINEERED SYSTEMS LISTED

Sprinkler Guards Model C Model D

Model DDX Deluge Valve

Gas Station & C Store SECTION CWM Job No

Discontinued Product

STORAGE FIRE PROTECTION SPRINKLERS

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Series 759 FireLock Alarm Check Valve

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE SUPPRESSION SPRINKLER SYSTEM

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION DRY-PIPE SPRINKLER SYSTEMS

Semi-Instantaneous Indirect Fired Water Heater

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

UL/FM Fire Protection Products

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

SECTION Fire Pumps

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

WATERSIDE BUILDING GROUP E4

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

Packaged Semi-Instantaneous Steam Fired Water Heater

SECTION WET FIRE SPRINKLER SYSTEMS

UL/FM Fire Protection Products Setting the Standard

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

Ruhrpumpen Fire Systems

Environmental Health & Safety

OPEN SPRINKLER SYSTEM

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Box-in-Box Cold Storage Fire Protection Options

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Reliable, effective, and powerful fire protection

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

SECTION WET-PIPE SPRINKLER SYSTEMS

TOTALPAC2 Integrated Fire Protection System

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SPECIFICATION: ARGONITE Engineered Fire Suppression System

PLUMBING HEATING GAS INDUSTRIAL ACTUATION HYDRONICS COMMITMENT TO QUALITY SPECIFICATIONS

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

DIVISION 21 - FIRE SUPPRESSION

UL/FM Fire Protection Products Setting the Standard

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

SECTION WET-PIPE SPRINKLER SYSTEMS

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

VIPER LANDSCAPING CAPABILITY STATEMENT

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Packaged Steam Fired Water Heater

WET-PIPE SPRINKLER SYSTEMS

SPRINKLERS TABLE OF CONTENTS

WFDE Series Waterflow Detector

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

A. This section includes design and performance information for fire protection and suppression systems.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Expectations (continued)

Submittal Packages Detailed with Items and Reviewers

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

SECTION FIRE-SUPPRESSION STANDPIPES

Viega Fire Protection Systems. Safety starts here

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

ADDENDUM NO. 3 March 19, 2018

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

EVOLUTIONARY PLUMBING SOLUTIONS FROM METER TO FIXTURE.

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

SECTION WET-PIPE SPRINKLER SYSTEMS

DIVISION 21 - FIRE SUPPRESSION

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Worldwide Contacts.

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Residential Fire Protection Sprinklers & Systems

Model F1FR Series Quick Response Standard Spray

mechanical. OPERATION Rapidrop Global

TotalPac 3 Firecyle III Deluge Remote controlled system

Transcription:

AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems BR-TESTa ndrain_2017 1/17 Reliability, Versatility, Code Compatibility

TESTa ndrain The Most Reliable and Versatile Inspector's Test and Drain Valves in the Sprinkler Industry AGF revolutionized the industry with the Model 1000 TESTa ndrain single handle ball valve inspector's test which eliminated the time and space consuming traditional loop assembly. Since then, TESTa ndrain valves have been installed in countless systems throughout the world. AGF continues to introduce innovative new products designed to simplify your installation. TESTa ndrain valves are now made in more styles, in more sizes, and with more orifice options than any other valve on the market. AGF is the brand you rely on to give you all the options you need with the proven reliability you and your customers demand. TABLE OF CONTENTS TESTa ndrain M1000... 3 M1011A... 3 M1011T... 3 M2500... 4 M2511A... 4 M2511T... 4 Re m o t e TEST M1200... 5 Inspector'sTEST M1200... 5 Ri s e rpack Residential M8000/M8011... 6 Commercial M8000/M8011... 6 Accessories Pressure Relief Valve... 7 Pressure Gauge... 7 Locking Plate Kit... 7 2 TESTa ndrain and Re m o t etest are registered trademarks of AGF Manufacturing Inc.

Model 1000 Lightweight and compact, the Model 1000 TESTanDRAIN is a 300 PSI rated, singlehandle ball valve specifically designed to provide both the test and express drain function required for a wet fire sprinkler system. The Model 1000 TESTanDRAIN meets all the requirements of NFPA 13D, NFPA 13R, and NFPA 13. It features a tamper resistant test orifice, integral tamper resistant sight glasses, and a tapped port for system access. The Model 1000 is available in ¾", 1", 1¼", 1½", and 2" sizes in both NPT and BSPT with all specifiable orifice sizes: 3 8" (2.8K), 7 16" (4.2K), ½" (5.6K), 17 32" (8.0K), 5 8" (ELO, 11.2K), ¾" (ESFR, 14.0K), and K25. Model 1011A Model 1011T The Model 1011A is similar to the Model 1000 but it includes a UL Listed/FM Approved Model 7000 Pressure Relief Valve with drainage piping. It is designed to relieve excess pressure caused by surges or temperature changes while solving the difficult problem of providing the relief valve with a convenient drainage/piping outlet. The Model 1011A complies with the requirements of NFPA 13 which stipulate a pressure relief valve be installed on all grid systems and downstream of all pressure reducing valves. The Model 1011T has the same features and benefits as the Model 1011A with UL Listed/FM Approved Model 7000 Pressure Relief Valve but also includes a Model 7500 Pressure Gauge and Model 7600 ¼" 3-Way Globe Valve. AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com 3

TESTa ndrain Model 2500 Like the Model 1000, the Model 2500 TESTa ndrain is a 300 PSI rated, single-handle ball valve specifically designed to provide both the test and express drain function required for a wet fire sprinkler system, but with an alternative handle location for multi-directional installations. The Model 2500 is available in 1" and 1¼" NPT and 2" groove with all specifiable orifice sizes: 3 8" (2.8K), 7 16" (4.2K), ½" (5.6K), 17 32" (8.0K), 5 8" (ELO, 11.2K), ¾" (ESFR, 14.0K), and K25. Model 2511A Model 2511T The Model 2511A is similar to the Model 2500 with multi-directional installation capabilities, but includes a UL Listed/FM Approved Model 7000 pressure relief valve with drainage piping. It is designed to relieve excess pressure caused by surges or temperature changes while solving the difficult problem of providing the relief valve with a convenient drainage piping outlet. The Model 2511A complies with the requirements of NFPA 13 which stipulate a pressure relief valve be installed on all grid systems and downstream of all pressure reducing valves. The Model 2511T has the same features and benefits as the Model 2511A with UL Listed/FM Approved Model 7000 Pressure Relief Valve but also includes a Model 7500 Pressure Gauge and Model 7600 ¼" 3-Way Globe Valve. 4 TESTa ndrain and Re m o t etest are registered trademarks of AGF Manufacturing Inc.

Re m o t e TEST Model 1200 The Model 1200 Re m o t e TEST TESTa ndrain saves time and conserves manpower by offering a self-contained method to "remotely" fulfill the primary function of the wet pipe system inspector's test. It is the only product that enables an individual to perform the inspector's test function on multiple systems from a central and remote position. The Model 1200, which retains the ability to be manually tested, can be integrated into an existing addressable fire alarm panel, wired to an auxiliary panel, or activated by a localized switch. The Model 1200 is also available with an optional bypass drain loop. In s p e c t o r'stest Model 3011 The Model 3011 In s p e c t o r'stest valve family is designed to perform the remote inspector's test function on single story and other applications with the benefit of locating the orifice sizes: 3 8" (2.8K), 7 16" (4.2K), ½" (5.6K), 17 32" (8.0K), 5 8" (ELO, 11.2K). Four models are available. Model 3011BV ball valve only Model 3011SG ball valve with sight glass Model 3011A ball valve with Model 7000 Pressure Relief Valve and drainage piping Model 3011ASG ball valve with sight glass, Model 7000 Pressure Relief Valve and drainage piping AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com 5

TESTa ndrain Re s i d e n t i a l Ri s e rpack for NFPA 13D NFPA 13D Ri s e rpack Floor Control Assemblies are designed to meet NFPA 13D requirements for residential wet fire sprinkler systems in family dwellings. M8000 13D M8011 13D Re s i d e n t i a l Ri s e rpack for NFPA 13R NFPA 13R Ri s e rpack Floor Control Assemblies are designed to meet NFPA 13R requirements for residential wet fire sprinkler systems in multi-family dwellings. M8000 13R M8011 13R Co m m e r c i a l Ri s e rpack for NFPA 13 NFPA 13 Ri s e rpack Floor Control Assemblies are designed to meet NFPA 13 requirements for commercial wet fire sprinkler systems in commercial buildings. M8000 M8011 6 TESTa ndrain and Re m o t etest are registered trademarks of AGF Manufacturing Inc.

Pressure Relief Valve The Model 7000 and Model 7200 are UL Listed/FM Approved pressure relief valves specifically designed for fire sprinkler systems. Both models relieve excess system pressure caused by surges or temperature changes and comply with NFPA 13 requirements that stipulate a pressure relief valve be installed on all grid systems and downstream of all pressure reducing valves. Both models feature a bronze body, stainless steel spring, and flushing handle to remove debris. The Model 7000 has a ½" MIPT inlet and FIPT outlet and is rated for installation in 175 PSI systems with other ratings available (165, 185, 195, 205, 225, and 250). The Model 7200 has a ¾" MIPT inlet and FIPT outlet and is rated for installation in 175 PSI systems. Pressure Gauge The Model 7500 Pressure Gauge is a UL Listed/FM Approved 3½" gauge designed for use on wet sprinkler systems. The Model 7600 ¼" 3-Way Globe Valve is a UL Listed/FM Approved valve designed to connect the pressure gauge to the sprinkler systems. Both devices meet NFPA 13 requirements. Locking Plate Kit Locking Plate Kits are available for the 1000 and 2500 series TESTa ndrain valves. Specifically designed to provide superior vandal resistance and to prevent unintentional alarm activation, Locking Plate Kits are highly recommended for public housing, schools, hospitals, and other public access areas. Locking Plate Kits eliminate the bothersome service calls caused by tampering. The kits allow the valve handle to be locked in the "OFF" position while still allowing easy access for inspection and maintenance. AGF Manufacturing, Inc. Since our founding, AGF Manufacturing, Inc. has been committed to providing a unique line of products for the fire sprinkler industry. We strive to maintain a close working relationship with our customers in order to meet the ever increasing demands of our industry. Over the years, this has helped us introduce many innovative products designed to meet a wide variety of needs. In filling these needs, we have built a strong reputation for providing the best products backed by an unwavering commitment to customer satisfaction. We continually work in the field to improve existing products, as well as invent new items. At AGF our mission is to design and manufacture unique products that engineers and architects can specify with confidence based on a proven record of reliability and fiscal accountability, and that make the contractor's job more efficient and competitive by providing cost-effective labor savings. Our entire product line is manufactured to the highest quality and meets or exceeds ISO 9002 standards. Our valves are approved by Underwriters Laboratories and FM Approvals, LLC. This commitment to quality enhances product reliability and end user satisfaction. AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com 7

AGF Manufacturing Inc. 100 Quaker Lane Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com