Electric Resistance Steam Humidifier. umidity Source Quality, Selection, Support

Similar documents
HumidiClean Series HC-4000 Humidifier

INSTALLATION INSTRUCTIONS

MES2. Installation and Operation Manual

"ESDDR" Series Electric Humidifier

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

HumidiClean Series HC-6000 Humidifier Revolutionary ionic bed technology that carries a lot of weight

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

Steam Humidification Light Commercial Applications. Better technology means better business.

HumidiClean Series HC-6000 Humidifier Revolutionary ionic bed technology that carries a lot of weight

Dishwasher. Installation manual DW60M9990AP

INSTALLATION & USER MANUAL

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

XT Series Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

Carbon Monoxide Transmitter

Steam Humidifier Models 1150 and 1160

Installation Instructions

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Owner's Manual. WS Series. Water Softener

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Installation Instructions

"ER" Series Electric Humidifier

CUFFED FAST-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Rif Cod i220-0

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Steam Humidifier. SK300 Series Installation Instructions and User Manual. SK300-ESL docx

ELECTRONIC COMMUNICATING THERMOSTAT

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

XTR Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

SKR series Steam Humidifier Kit N (Patent Pending)

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

LE Series. Electrode Steam Humidifiers

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

Model 1820 Dehumidifier

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

Installation Electric Dryers Instructions 01

EUQA Humidifier, for circulated water

Ultra-sorb Models LV and LH

READ AND SAVE THESE INSTRUCTIONS XTR. Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

ComfortSTEAM TM. Humidification System

Quick Start Installation Guide

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Electrode steam humidifier

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

GS Series. Gas Steam Humidifiers. Designed for air handling systems and for areas requiring individual humidification control

MIX Boiler & Font Range Service Manual

Installation Instructions

MiniVap Humidifier Models LMV2 & LMV4

Key benefits. Why Condair CP3?

Installation Instructions

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

MacDonald Steel Limited

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Pressurized Condensate Return System (PCR)

HE360 Humidifier Installation Kit

Residential Steam Humidifier

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

Quickheat 30 weather compensated boiler control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Installation Instructions

Installation & Maintenance Manual

Scotsman Technical Training. CU50 Cube Ice Machine

Table of Contents SECTION PAGE

Installation Instructions Owner s Manual

Rev B, 9/2/2009. Kodiak Chiller Overview

CEILING FAN OWNER'S MANUAL

Humidifi er FAQ. Why is the humidifier not running? The following conditions need to be satisfied before the humidifier sequence can start:

DC200 Digital Dispenser Operating Manual

DRI-STEEM Models and LTS-DI

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

Dishwasher Installation Manual

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

Safety, Installation, and Operation Manual

CAREL heatersteam Electric Element Steam Humidifiers

EC Series Wall Unit Humidifier

DRI-STEEM Models LTS and LTS-DI

LQQA Humidifier, for circulated water

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

HumidiClean. Series HC- 4100/4145/4300/4500 Humidifiers. Installation, Operation and Maintenance Instructions. Table of Contents.

Installation and Operation Guide

INSTALLATION GUIDE NZ AU

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Installation, Operation, Maintenance, and Troubleshooting Guide

Marvel J MICROPROCESSOR CONTROLLER

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

CMC Electrode steam humidifier

SKR series Steam Humidifier with SDU module (Patent Pending)

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Transcription:

Electric Resistance Steam Humidifier H umidity Source Quality, Selection, Support

PERFORMANCE AND FEATURES - Full range : (11-220 lbs/hr) output - Works with any type of water - Microprocessor control with easy-to-read backlit display - Self diagnostic with default display - Proportional control or ON/OFF - Accuracy +/- 2 % RH - Accept all common modulating signals - Duct pressure up to 10.03" H 2 O - Combined capacity up to 1543 lbs/hr - Anti foaming control - Integral humidity controller or external control - High flow cooling fan preventing overheating - Automatic drain after inactivity - Fast drain (max. 15 sec) - Manual drain possible - Inlet valve with internal filter - Outlet valve with large orifice for easy-scale elimination - Self cleaning level control probe - Option to maintain tank water at (175 F) - CE marked - CSA-c-us listed EASY MAINTENANCE - Permanent stainless steel tank - Self cleaning INCOLOY elements repelling scale - Pivoting tank with intermediary position allowing easy maintenance - Cooling cycle before maintenance conserves downtime - Frontal access to all components - Display message to point out maintenance to do OPTIONS - Remote information board - RS 485 interface with possibility to give number of units for easy BMS control - High level safety humidistat and sensor - Steam and condensate hoses - Steam pipe for standard or short distance absorption

H umidity Source Quality, Selection, Support Supply V 460V 3ph 480V 3ph 575V 3ph 600V 3ph RTH Model lbs/hr A Kw lbs/hr A Kw Lls/hr A Kw lbs/hr A Kw No. of Tanks 7 15 7 5 17 7 6 15 5 5 17 6 6 1 15 36 16 12 40 16 14 36 13 13 40 13 14 1 20 52 22 18 56 23 19 52 18 18 56 19 19 1 30 73 31 25 79 33 27 73 25 25 79 26 27 1 40 88 38 30 96 40 33 88 30 30 96 32 33 1 50 109 47 37 119 49 41 109 38 38 119 39 41 1 60 124 54 43 135 56 47 124 43 43 136 45 47 2 70 145 63 50 158 66 545 145 50 50 158 53 54 2 80 176 76 60 192 79 66 176 61 61 192 64 66 2 90 197 85 68 215 89 74 197 68 68 215 71 74 2 100 218 94 75 237 98 82 218 75 75 238 79 82 2 Supply V 230V 1ph 208V 3ph 230V 3ph RTH Model lbs/hr A Kw lbs/hr A Kw lbs/hr A Kw No. of Tanks 5 13 20 5 1 8 18 28 6 14 13 5 17 14 6 1 18 32 31 11 40 34 14 1 25 46 44 16 56 49 19 1 36 65 62 22 79 68 27 2 44 78 75 27 96 83 33 2 51 92 88 32 112 97 39 2 62 111 106 38 135 11 7 47 2 Number of Tanks Dimension (L x H x W) Net Weight lbs. Full Weight lbs. 1 32 x 30 x 14 77 143 2 48 x 30 x 14 143 268 Disconnect the steam hose and remove it from the cabinet. Tilt tank forward to first stop. Unlock the tank cap and set electrode elements on top of the humidifier upside down. (No need to disconnect the wiring) The fast draining followed by the cool cycle causes the electrode scale to fall off. Simple Maintenance! Adjust the flexible scale collection bag on the tank. Humidity Source, LLC 90 Dayton Ave. Suite 58 Passaic, New Jersey 07055 TEL 973-916-1001 FAX: 973-916-0770 Swing the tank completely down, all the scale will fall into the collection bag.

INSTALLATION MANUAL Contents Unit wall installation Dimensions 3 Wall mounting 4-5 Water connection 6 Steam output 7 Condensate draining 8 Steam distribution pipe 9 Steam pipe positioning 10-11 Absorption distance 12 Electrical installation Electrical wiring 13-15 Connecting options 16 Software assistant Start up 17-18 Humidifier configuration menu 19-20 Humidifier status menu 21 Changing unit configuration 22-23 Alerts and warnings 24 Maintenance Tank maintenance 25-26 Valves maintenance 27

Unit mounting ElectroVap RTH Dimensions 1 B RTH 5 to 50 a Overall dimensions (in) Steam outlet (in) Drain outlet (in) Weight empty (lbs) Weight full (lbs) A C A 31.5 1 12.6 a 3.0 77 143 B 29.6 C 13.4 1 2 B a A C RTH 60 to 100 Overall dimension (in) Steam outlet (in) Weight empty (lbs) Weight full (lbs) A 47.3 1 10.0 a 3.0 110 265 B 29.6 2 18.4 C 13.4 Drain outlet (in) 3

Unit Wall Installation UNIT MOUNTING Unpack the unit and check for any damage. A drilling template is supplied with the packing : make sure to locate it before throwing away the packing material. Damage to packing and/or unit must be reported immediately to the trucker. Save all packing materials for their inspector. Provide free space all around the unit, 3 to 3 1/2 ft. from the floor to the bottom of the humidifier and at least 3 ft. above and 2 ft. on the right hand side for allowing easy access for maintenance. Position the supplied drilling template against the mounting wall and mark the mounting holes. Drill the 7 (seven) holes and insert screws and bolts appropriate for support (3 across top and 4 behind tank. ). 1 4 Install the 3 (three) upper screws allowing about 1/2 in. for hanging the cabinet. Hang the cabinet and tighten the upper screws for securing the mounting. 3 4 Loosen the release knob (1) a little, tip the stainless steel tank (2) down until the steel restraining cord is tight (3). 3 2 Disconnect the water level wires (4). Draining hose 2 4

Unit Wall Installation UNIT MOUNTING (continued) Unlock the tank cover and lay it on the top of the humidifier upside down. Release the steel restraining cord while holding the tank. Let the tank gently tip all the way down. Insert lower screws at 4, 5, 6 & 7 then tighten all seven mounting screws. Once all the screws are tightened, you can : Tip the tank back to intermediate position and attach the steel restraining cord. Replace the tank cover and secure the 4 fasteners. Reconnect the high water level wires. Set the humidifier tank back to upright position and tighten tank release knob 1 (see page 4). 4,5,6,7 5

Water Connection Unit mounting A fresh cold water service should be used to supply the unit. The water pressure should be between 15 and 90 psi and should not exceed 100 F in temperature. The water supply connection is through the bottom of the unit. The humidifier is delivered with a 20 in. long water inlet hose, with a 3/4 in. threaded female connector for the cold water supply. A manual shut-off valve and a check valve (not included) should be located on the cold water service connection to the unit. Water inlet hose. Shut-off Valve w/check valve. Information about the water quality : Chloride concentration < 75 mg/l Phosphate concentration < 5 mg/l Low concentration of CO2. Organic elements in low concentration Tap water or raw water Water supply service. The water total desolved solids (TDS) may be up to 23 gr/gal (400 ppm). Check with the local water company. For tank maintenance, refer to the maintenance page. Softened water The water TDS can be from 3.5 gr/gal (60 ppm) up. Demineralized water The RTH humidifier can run with demineralized water of 30 µs minimum (0.7 gr/gal or 12 ppm). 6

Steam Output Installation c Use only high quality, low pressure steam hose which is able to withstand steam humidifier temperatures. a b e d The steam hose alone may be used for distances up to 6 ft. If the distance from the humidifier to the duct is greater than 6ft., insulated rigid copper tube should be used, with sections of steam hose for connectors. h f To Drain g All steam lines must be pitched so that condensate which forms in the lines will be drained back to the steam generator or to a separator & trap in the steam line. a. Provide vertical rise at least 20 in. before bending the hose to horizontal. b. The steam hose should be rigidly suported to promote rapid draining. c. Steam hose (radius of bend should be 30 in. Minimum.) d. Duct work. Steam Hose Sizes 40mm (1.6 in.) Dia. for RTH 5 to 20 60mm (2.4 in.) Dia. for RTH 30 to 100 e. Obstacle. f. A condensate separator and trap is needed at this point to drain condensate. g. 8 mm condensate hose. Fill the condensate hose trap with water before starting the humidifier to prevent steam from escaping. h. Humidifier height (see page 3. ) Number of steam outlets: RTH 5 to 20 = 1 outlet 60mm ( 2.4 ) Reducer may be used (see page 9) RTH 30 to 50 = 1 outlet 60mm (2.4 ) RTH 60 to 100 = 2 outlets 60mm (2.4 ) The RTH humidifier can work with duct pressure up to 10 of water column. 7

Condensate Draining Installation Drain Connections Use high quality steam hose capable of steam humidifier temperatures up to 212 deg F. RTH 5 to 100: 3 ft. of 40mm hose with 3 hose clamps provided. Caution! Steam Vapor 10 This hose is designed for connecting the humidifier to the drain. Periodic replacement may be recommended. If rigid piping is used, use copper or heat resistant PVC material (212 F ). 12 in. The drain hose must be free from any obstacle particularly when it comes to connecting several units. 18 in. 1 inch min. dia. It is recommended the piping be offset rom the underside of the unit as shown. This will prevent any steam and/or condensation from rising directly into the cabinet. A funnel can be used as well provided it is offset from the underside of the humidifier and that a drain trap is made as per the diameter of the draining hose. Important : keep a minimum pitch of 10 Caution! Steam Vapor 10 3 inch min. 8

Steam Distribution Pipe Installation Steam dispersion pipe DL 1.6 in. or 2.4 in. 8mm 2 in. L1 Steam from the humidifier enters the duct or an air handling unit via a steam distribution pipe. For optimum absorption of the steam, select the longest possible pipe. Use multiple pipes if neccessary. HumidiPack The HumidiPack is a pre-fabricated steam humidifier panel made to suit the duct or AHU conditions and ready to be installed. It allows for absorption distances as short as 2 ft. Air flow HumidiPack Steam Distribution Tube Model for : RTH 5 to 20 L1 In. L4029 12 L4059 24 L4079 31 L40100 39 L40125 50 L40150 59 A 2.4 in. to 1.6 in. reducer is used with distribution pipe of 1.6 in. for ElectroVap RTH 5 to 20. Steam Distribution Tube Model for : RTH 30 to 90 L1 in. DL-1 10 DL-1,5 16 DL-2 22 DL-3 34 DL-4 46 DL-5 58 DL-6 70 DL-7 82 DL-8 94 DL-9 106 DL-10 118 9

Steam Pipe Positioning Installation Install the distribution pipe on the duct with 4 scews. 12 in. 6 in. A minimum distance of 12 in. between the center of the steam distribution pipe and the top of the duct should be alllowed. Where the distribution pipe is installed at an angle of between 30 and 45, this may be reduced to 6 in. Where the application requires two distribution pipes, the above-mentioned recommendations should be observed keeping a minimum space of 6 in. between the pipes. (d) is the minimum distance between the distribution pipe and any obstacle within the duct (see table on page 12). Where a steam pipe is installed after a bend, it should be positioned in the main air flow. In vertical ducts where the air flow is upward or downwards, the steam distribution pipe should be mounted at an angle of 15 from vertical 10

Installation ElectroVap RTH Steam Pipe Positioning Pipe above humidifier RTH 5 to 50 Pipe under humififer RTH 5 to 50 Condensate Condensate HmidiPack insertion in duct RTH 5 to 50 Draining 12 in. min. Condensate 8 in. min. Trap must be full of water before starting the unit Insertion in duct RTH 60 to 100 HumidiPack insertion in duct RTH 60 to 100 Air Flow Air Flow Condensate 11

Absorption Distance Installation RH2 in % Absorbing Distance In Inches (D) Delta RH %(RH2 RH1) 5 10 15 20 30 40 50 60 75 90 40 12 16 20 20 28 32 50 16 20 20 28 32 36 40 60 16 20 24 28 36 40 43 48 70 20 24 28 36 40 48 50 60 80 20 28 36 40 48 55 63 71 80 85 24 32 40 40 55 63 71 80 91 90 28 40 48 55 60 80 90 100 110 120 95 40 55 67 80 100 114 126 140 154 170 Before or after fan Duct transistions In order to determine the absorption distance, this table can be used if you have the following : RH1 = relative humidity of the air before humidification. RH2 = relative humidity of the air after humidification in %. Delta RH = difference between RH1 & RH2 How to use the table Determine the difference between the relative humidity (RH2) after the humidification and the relative humidity (RH1) before humidification. The intersection between the delta RH value and RH2 gives the evaporation distance in inches.. The drawings show the distance (D) in inches that should be allowed between the distribution pipe and the first obstacle. If the required distance is not available, it is possible to install two pipes in parallel to give better steam distribution. Elbows and branches A multi-steam distribution panel may be used for short absorption distances. See catalog. A high limit humidistat should be installed to prevent excessive humidity levels in the duct. Controls and sensors Note : The absorption distances given in the table are for temperatures between 50 F and 78 F. If accurate values cannot be determined or estimated, a distance of 6.5 ft. should be used as a safe minimum distance between distribution pipes & any obstruction. Before/after filters 12

Electrical Wiring Installation Power supply connection Beware! Before connecting the power supply, make sure that the main breaker is the same capacity as the the unit requirements. Power wire and control circuit connecting terminals Ground terminals 13

Electrical Wiring Installation RTH 5 RTH 60 to 100 Caisson de Blower ventilation pack pour (if l'ambianc used) e (option) 3 4 Blower Caisson pack de (if used) ventilation pour l'ambiance (option) 3 4 Power PUISSANCE Circuit- 2x230V Single VAC 50-60Hz Phase Protection External externe power puissance protection A2 1/L1 2/T1 2 T1 4 T2 6 T3 14 NO L1 L2 S1 K1 4/A2-3/A1+ 1 L1 A1 3 L2 5 L3 13 NO A2 2/T1 1/L1 2/T1 1/L1 2/T1 1/L1 S1 S2 S3 4/A2-3/A1+ 4/A2-4/A2-3/A1+ 3/A1+ COMMANDE Control Circuit 2x230V VAC 230-1-60 50-60Hz + TERRE Protection 2 A external externe power control commande 2A Voir See chapitre operating raccordemen control ts régulation connections 1 2 N L PE 2/T1 1/L1 2 T1 S4 3/A1+ 4/A2-1 L1 A1 4 T2 3 L2 6 T3 K1 5 L3 RTH 10 to 50 A2 14 NO 2 T1 13 NO A2 1 L1 A1 Blower Caisson pack de (if used) ventilation pour l'ambiance (option) 3 4 4 T2 6 T3 K2 3 L2 5 L3 1/L1 2/T1 1/L1 2/T1 S1 S2 4/A2-3/A1+ 4/A2-3/A1+ F u s e PUISSANCE 3x400V VAC 50-60Hz Power Circuit Protection externe Three Phase puissance 2 A External Protection COMMANDE Control Control externe 2x230V Circuit VAC Circuit commande 2A 50-60Hz 230-1-60 + Fusing TERRE A2 14 NO L1 L2 L3 N L PE 13 NO A2 2 T1 4 T2 1 L1 3 L2 A1 See Voir chapitre Operating raccordements Control régulation Connecrtions 1 2 6 T3 K1 5 L3 A2 14 NO 13 NO A2 F u s e Power Circuit Protection externe Three Phase puissance PUISSANCE 3x400V VAC 50-60Hz Protection 2 A External COMMANDE Control externe Control Circuit 2x230V Circuit VAC command Fusing e 2A 50230-1-60-60Hz + TERRE L1 L2 L3 N L PE NOTE: External power protection ( fuse or circuit breaker) must be provided in accordance with all national and local codes. Voir See chapitre raccordemen Operating ts régulation control Connections 1 2 14

Control Connection Installation RJ45 connector : provides for a computer connection Dip Switch S1: To select the control signal (see above configuration drawings) X6 connector: 21-22-23-24-25 X5 connector: 18-19-20 Main board # 500101/03 15

Connecting Options Electrical installation Remote information Main board board A On NO peut or ainsi NC contact choisir un can contact be NO selected ou NF simplement by simply en changeant la position du connecteur. changing the position of the connector. Remote information board NO 36 33 30 37 35 38 34 31 32 NF NC X22 X21 X20 Ex. X20 30 31 32 NO X20 30 31 32 NC NF Board # 500400/03 Connector X22 (36-37-38): steam production information dry contact Connector X21 (33-34-35): general fault information dry contact Connector X20 (30-31-32): cylinder maintenance information dry contact Option - RS485 or RS422 or RS232 interface Board # 500800/01 CHARACTERISTICS: RS485 : 2 wires half duplex (+GND) Max. distance 4000 ft. RS422 : 4 wires half duplex (+GND) Max. distance 4000 ft. RS232 : 2 wires half duplex (+GND) Max. distance 800 ft. Bias : 620 Ohms pull-up & pull-down (jumpers selectable) Termination : 120 Ohms (jumper selectable) Protocol : JBUS or MODBUS (data asyncronos of 8 bits, no parity bit, 1 stop bit, CRC) - Speed : 1200, 2400, 4800, 9600 baud. Mounting : on unit Din rail. Dimensions : 3.7 x 2 in. 16

Front panel identification Software assistant Alphanumerical Display Scroll Down Scroll Up Select Menu Manual Drain Steam Production Light ON/OFF Switch Power Light 17

RTH Startup Software assistant STARTUP 1 After completion of the installation inspection, turn on the water supply to the unit 2 Switch on the main power supply. 3 The power lamp should be illuminated. 4 Switch the power supply I/O switch on I. The display will default to show the rate of steam produced. Display operation : 1 Pressing the SELECT button repeatedly will rotate between the three main menus. 2 Enter the desired menu by pressing the up or down button. The unit provides three menus : HUMIDIFIER CONFIGURATION This menu provides information only on the setup of the humidifier. No parameters can be changed from within this menu. HUMIDIFIER STATUS This menu provides information on the operating status of the humidifier. No parameters can be changed from within this menu. CHANGING UNIT CONFIGURATION This menu allows adjustments to the setup or operating parameters of the unit. Access to the changing humidifier configuration menu is protected by an access code to guard against unauthorized access. See Configuring the unit. 18

Humidifier Configuration Menu Software assistant STARTING UP MENU: HUMIDIFIER CONFIGURATION Press the key for changiing menu at any time SOFTWARE VERSION HUMIDIFIER This shows the model of humidifier This indicates the version software in use OR PRODUCED STEAM If using an external proportional sensor/ controller EXTERNAL REGULATION SIGNAL Y:..V If using ON/OFF or 2, 3 or 4 step control If using an external proportional humidity sensor only SET POINT: % MEASURED RH :.. % This shows the control signal demand from 20 to 100 % of capacity. STEAM DEMAND This shows the temperature inside the tank TANK TEMPERATURE This shows steam production remain ing (in KG) before service is required. This is a maintenance planning tool. PRODUCTION BEFORE CLEANING.. KG This shows the working time is hours that is left before maintenance. This is a maintenance planning tool. TIME BEFORE MAINTENANCE.. H This shows the number of working hours since last maintenance. TIME COUNTER.. H 19

Humidifier Configuration Menu Software Assistant (continued) - Press the key to change menu at any time. STEAM COUNTER DRAIN AFTER HOURS YES NO HOURS ELECTRICAL POWER KW 20

Humidifier Status Menu Software Assistant MENU: HUMIDIFIER STATUS - Press the key for changing Menu at any time. OR This shows the selected control signal CONTROL SIGNAL IN. This shows the total steam production since humidifier start-up TOTAL KG/ST PRODUCED. This indicates the total operating hours since humidifier start-up TOTAL WORKING HOURS..H This shows the type of water (city, softened, demineralized) selected for this humidifier. WATER USED This indicates the selected voltage for the humidifier POWER VOLTAGE... This shows the maximum power necessary for this humidifier INSTALLED POWER.. KW 21

Changing Unit Configuration Menu Software Assistant MENU: CHANGING UNIT CONFIGURATION Allows selection of the control signal you wish to use. OR DIAL ACCESS CODE : XXX SELECTED CONTROL SIGNAL :.. To gain entry, dial access code 2.3.4 : Press the key and the first digit will flash Using the keys enter the first digit of the access code and then press the key to confirm. The next digit will start to flash. Repeat for a second and third digit of the access code. Limits steam output from 100% down to 50% of units maximum. STEAM CAPACITY LIMIT :. %. SET POINT ADJUSTEMENT..%HR PROPORTIONAL BAND ADJUSTMENT..% If on-off humidistat or external proportional sensor/controller are used, set point & propl band are not set on the humidifier display, but on the humidistat or external control. Allows adjustment of the estimated number of kg of steam to be produced before next maintenance. MAINTENANCE FREQUENCY..KG/ST Sets the hours of operation until the next tank maintenance message appears on the display screen. Adjusts the temperature maintained inside the tank when the humidifier is stopped MAINTENANCE INTERVAL..H WATER TEMP. AT 65 C YES / NO WATER TEMP. MAINTAINED AT. C Maintains the water tank temperature at 150 F while the humidifier is not producing steam. For freeze protection and / or faster steam production for closer humidity control. This enables a cooling cycle of the water tank before its maintenance TANK COOLING YES / NO This allows adjustment of the short duration drains after a succession of water intakes. CYCLIC DRAINING TIME... Automatic inactivity (end of season) drain when there is no steam production for 72 hours. Adjustable 1 DRAINING IF LONG STOP YES / NO 22

Changing Unit Configuration Menu (continued) Software Assistant YES NO DRAINING AFTER A STOP OF :.. H Determines the draining frequency of the short duration drains. FREQ: 1 DRAIN EVERY 4 CYCLES Select shut down or continue to operate when the maintenance message is shown. STOP RTH WHEN MAINTENANCE YES / NO To assign an identification number to this unit when there are a number of humidifiers. IDENTIFICATION... TRANSMISSION SPEED : 9600 B/S Example CHANGING THE MAXIMUM STEAM OUTPUT: STEAM CAPACITY LIMIT :. %. Scroll menu to get this message, press the key and the value will flash. Using the and keys, adjust the maximum output from 100% to 50%. Once the desired value is reached, press the The display will show : RECORDED PARAMETER. key to confirm. 23

Alerts and Warnings Alerts Software Assistant What you should do when : WATER MISSING MAINTENANCE REQUIRED Humidifier status : unit stopped Switch the humidifier off Check internal water piping. Check water level detection system Switch the humidifier on again. Maintenance warning What you should do when : TANK AND DRAIN VALVE MAINTENANCE REQUIRED Humidifier status : unit stopped Switch the humidifier off See the Maintenance section of this manual and follow the maintenance procedure Switch the humidifier on again. TANK MAINTENANCE AND DRAIN VALVE - The humidifier must be reinitiated by pressing these bottons simultaneously. - The humidifier can work again and the maintenance timer can be reset at the desired value (see page 22, 23). NEXT MAINTENANCE WITHIN : H The windows shows : Press on to go back to the Humidifier Configuration menu. 24

Tank Maintenance Maintenance Picture 1 Drain the tank by pressing the manual drain button (Picture 1). Wait for complete draining and allow the tank to cool down (in case this feature has been enabled) Cut off the power supply at the disconnect switch and switch off the RTH humidifier Picture 2 Screw off the front door, lift it a little and take it away. Remove the black steam hose from the steam tank (Picture 2) and draw it out of the humidifier. Picture 3 Loosen the black tank release knob and remove the drain hose (Picture 3). Picture 4 Swing the tank to intermediate position (Picture 4). Picture 5 Unlock the 4 locks of the tank (Picture 5). Picture 6 Take off the water level tank cap (Picture 6). CAUTION : do not use any solvent to clean the water level tank. If the sensor needs being attended, use teflon material only. 25

(Continued) Picture 7 ElectroVap RTH Tank Maintenance Maintenance Lift the tank cover (note the positioning mark) and lay it upside down on the top of the humidifier (Picture 7). Remove the high water level tank and lay it on the top of the humidifier. Adjust the collection bag on the tank rim and attach the handles to the tank lateral hooks (picture 8). Picture 8 Release the tank holding steel cord and swing the tank down : the mineral deposit falls into the flexible container. (Picture 9). Remove the collection bag and swing the tank back to intermediate position. Attach the holding steel cord to the tank. (Picture 7) Grease the square tank gasket with silicone grease. Picture 9 Picture 10 TAKE CARE : the tank gasket must be changed if found flawed. Cut used gasket with a knife or cutter ; clean out the tank rim with acetone and secure the new gasket with heat resistant glue (320 F) appropriate to steel material. Put the tank cover back onto the tank body taking care to align the positioning mark and put back the high water level tank cap. Swing the tank up (Picture 10). Then tighten up the black knob and reconnect the drain and steam hoses. The humidifier is now ready for operation. (Picture 11) Picture 11 26

Drain valve maintenance ElectroVap RTH Valve Maintenance Maintenance Drain steam tank out and switch unit off. Remove screw 1 then swing coil holder 2 to the left. 1 Remove coil 3 from the actuator assembly 4 (don t miss the small parts). 3 4 2 Dismount assembly 5, clean valve 6 and rinse body 7. Reassemble all the parts. 5 6 Change parts if needed. Swing coil holder 2 back and tighten screw 1. 7 Inlet valve maintenance Turn the water supply off and switch humidifier off. 1 Remove water inlet hose. 4 Take out filter 2 with a pair of pliers and flush it with clear water. 2 Pull coil 3 out with the help of a small screwdriver. 3 Flush with clear water the internal part of valve body 4. Change parts if needed. Reassemble. 27