RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

Similar documents
CD100A COMBUSTIBLE GAS DETECTOR

LS1. Operator Manual. Kane International Ltd

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

KANE-ALERT-CO 2 Monitor with Temperature

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

CLI Refrigerant Gas Leak Detector. User s Guide

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

H-10PM. Refrigerant Leak Detector

Temporary wireless battery operated fire system from Channel Safety Systems

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Instruction Manual MSI Sensit HXG

Refrigerant Leak Detector

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Combustible Gas Leak Detector Instruction Manual

TEK-Mate. Refrigerant Leak Detector

GAS-Mate. Combustible Gas Leak Detector

TEK-Mate. Refrigerant Leak Detector

For technical support call:

D-TEK Select. Refrigerant Leak Detector

NGD8800 USER S MANUAL

Operating Instructions

Leak-Seeker I Refrigerant Leak Detector

GasAlertMicroClip X3 Specifications

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

RAM GENE / RAM GENE-1

RS Pro Infrared Temperature Sensor

Flame Safeguards LFE10. Building Technologies HVAC Products

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

GERMANY TEC 'LOGY leak-detect EXPERT

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

RLD-H10P Refrigerant Leak Detector

Flame detector. The QRA4.U is for use with the following types of burner control:

LD-5000 REFRIGERANT LEAK DETECTOR

Whisper. Ultrasonic Leak Detector

IMR IX176 Portable Gas Detector User Manual

Combustible Gas Leak Detector Instruction Manual

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

SENSIT HXG-2d Combustible Gas Detector

RLD-H10G Refrigerant Leak Detectors

Refrigerant / Combustibles Leak Detector

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Flame detector. Building Technologies Division Infrastructure & Cities Sector

INSTRUCTION MANUAL CD Fax: (503)

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

USER MANUAL MINITRACER PORTABLE SNIFFER

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

OPERATING INSTRUCTIONS

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Restek s Electronic Leak Detector

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

testo 316-EX gas leak detector Instruction manual

NEW Restek Electronic Leak Detector

99 Washington Street Melrose, MA Phone Toll Free Visit us at

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

AlcoBlow. User Handbook

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

T.ex Single Gas Detector VISA

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

User Manual SF6 GASCHECK 6000

Programmable Towel Radiator Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Dry Bath Heating Systems

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

for relative humidity and temperature

The Remote alarm Panel, TYPE RAPv2

LAE10 LFE10. Use. Series 02

EST User Manual. (Please read this manual carefully before using)

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

P162B Radio PIR Motion Detector

Lutron GS-5800 ULTRASONIC GAS LEAKAGE DETECTOR

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

P162A Wired PIR Motion Detector

715 Portable MANUAL JUNHO 2013

Sip Vacuum Cleaner 1400/35 Wet & Dry

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Refrigerant Leak Detection Solutions

Imperial Electric Fires

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Clip SGD. Portable single Gas Detector. User manual

TOOLS AND INSTRUMENTS

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

Refrigerant / Combustibles Leak Detector

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

AIR CONDITIONNING 95 CODE 002

Transcription:

RD99 REFRIGERANT GAS LEAK DETECTOR Kane International Limited Kane House, Swallowfield Welwyn Garden City, Hertfordshire AL7 1JG Tel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 Stock No: 17200 WARNING! Turn the unit off and remove the battery before cleaning or replacing sensor. Failure to do so may result in mild electrical shock or damage to the instrument.

Protection Against Electric Shock (in accordance with EN 61010-1 : 1993) This instrument is designated as Class III equipment and should only be connected to SELV circuits. 1

TABLE OF CONTENTS PRODUCT FEATURES...3 GENERAL DESCRIPTION...4 OPERATION...5-8 BASIC OPERATION LOW SENSITIVITY MODE HIGH SENSITIVITY MODE RESETTING ZERO EMC...8-9 BATTERY REPLACEMENT...10 SENSOR REPLACEMENT...11 SPECIFICATIONS...12 WARRANTY INFORMATION...13 APPENDIX...14 2

H PRODUCT FEATURES 1 2 5 6 3 PWR LOW BAT RD99 N\ IG H HIGH O LOW L W O OFF O FF 7 8 4 9 10 1. 2. 3. 4. 5. Protective boot Low battery indicator Power on light Audible leak indicator Advanced ionisation sensor 6. 7. 8. 9. 10. Sensor protector Gooseneck clip LED array High/Low/OFF switch Flexible gooseneck 3

GENERAL DESCRIPTION The RD99 is an advanced technology refrigerant gas leak detector. This detector is capable of locating any of the current halogen based gases such as refrigerants. These gases include CFCs, HCFCs and HFCs. A partial list of these gases include: CFCs - R11, R12, R13 etc HCFCs - R22, R502, R500 etc HFCs - R134A, R123, R125, R33 etc This unit will detect other halogen compounds such as SF6, Perchlorethylene and Halon. Please contact your distributor or Kane International Ltd for more information on a specific application. This instrument is not to be used in combustible environments. 4

BASIC OPERATION OPERATION 1. Turn the instrument ON by sliding the High/Low/OFF switch to either LOW or HIGH in a non-contaminated environment i.e. Fresh air 2. The power light will be illuminated green when the unit is turned on. If the batteries are too low to operate the instrument this light will be RED. 3. The instrument can be switched off at any time by moving the switch to OFF. It is advisable to turn off in fresh air. 4. If the tip of the sensor becomes wet shake off excess and allow to dry naturally. 5

LOW SENSITIVITY MODE With the switch set to LOW: 5. The LED array will cycle from green to yellow, and then red indicating the instrument is performing an auto-zero. 6. Once the auto-zero is complete the green LED will settle to a steady 2 second flash rate accompanied by a bip. This indicates the instrument is ready for use. 7. To pinpoint a leak source, move the sensor tip along the area to be checked. The tick rate will increase as you approach a leak and the green LED will flash faster. As concentration of gas increases the LED array will progressively move from flashing yellow, orange and red (highest). 8. The tick rate will decrease and the lights will go out when you move away from the leak source. 6

HIGH SENSITIVITY MODE To pinpoint the leak or find a very small leak: 9. Set the instrument to HIGH sensitivity using the slide switch, when switching from LOW to HIGH sensitivity the top red LED will flash once. 10. Operation is as in low sensitivity mode but is more sensitive to small changes in concentration. 11. Move the tip to levels of higher concentration indicated by an increase in tick rate and more lights on the LED array. If the LED array displays continuously flashing red, turn the switch to Low Sensitivity and continue. RESETTING ZERO 12. In fresh air the green LED should settle to a 2 second flash rate accompanied by a blip sound. 7

13. To reset zero in fresh air, turn off the unit for about 2 seconds then turn on in either LOW or HIGH sensitivity mode. ELECTROMAGNETIC COMPATIBILITY The European Council Directive 89/336/EEC requires that electronic equipment does not generate electromagnetic disturbances that exceed defined levels and has an adequate level of immunity to enable it to be operated as intended. The specific standards applicable to this product are detailed in the appendices. Since there are many electrical products in use that pre-date this Directive and may emit electromagnetic radiation in excess of the standards defined in the Directive there may be occasions where it would be appropriate to check the detector prior to use. The following procedure should be adopted: 8

Go through the normal start up sequence in the location where the equipment is to be used. Switch on all localised electrical equipment that might be capable of causing interference. Check that all readings are as expected. (A level of disturbance in the readings is acceptable). If not adjust the position of the instrument to minimise interference or switch off, if possible, the offending equipment for the duration of the test. At the time of writing this manual (Feb 1999) Kane International Ltd is not aware of any field based situation where such interference has ever occurred and this advice is only given to satisfy the requirements of the Directive. 9

BATTERY REPLACEMENT 1. Remove the battery cover on the back of the instrument. 2. Replace the 9 volt battery. A lithium or alkaline battery should always be used. Ensure the terminals on the battery are the correct polarity. 3. Replace the battery cover ensuring it is clicked home and locked in place. 10

SENSOR REPLACEMENT If the tick rate becomes uncontrollable, it may be necessary to change the sensor. We recommend that the sensor should be replaced at least once a year. To remove the sensor: 1. Turn the unit off and remove the battery. 2. Unscrew the sensor anti-clockwise from the gooseneck. 3. Replace with new sensor by turning the sensor clockwise until finger tight. WARNING! Turn the unit off and remove the battery before cleaning or replacing sensor. Failure to do so may result in mild electrical shock or damage to the instrument. 11

SPECIFICATIONS Power Supply: Sensor: Sensitivity: Indicators: Warm-up: Response Time: Duty Cycle: Battery Life: Dimensions: Weight: Probe Length: Ambient Conditions: One 9V PP3 battery Advanced ionisation detection 5 gms per year 134A based on LS-20 leak standard Audible: Auto-zero tick rate Visual: Flashing LED array <10 seconds <1 second Continuous Approx 8 hours 180mmH x 70mmW x 35mmD 400gms 400mm 0-40 C, 0-80% RH (noncondensing) Sensor-tip output voltage/current: A. No load high voltage 2500V+10% B. Current - 24µA C. Loaded high voltage (loaded with 100.1MΩ) 2400V+50V 12

WARRANTY All Kane International Limited instruments include batteries and carry a 12 month warranty, covering any manufacturing defects and component failures. This warranty applies to all Kane International Limited products world-wide. In line with our policy of continuous development we reserve the right to alter any part of our product specification without prior notice. 13

APPENDIX ELECTROMAGNETIC COMPATIBILITY This product has been tested for compliance with the following generic standards: EN 50081-1 EN 50082-1 and is certified to be compliant Specification EC/EMC/KI/RD99 details the specific test configuration, performance and conditions of use. 14