A COMMERCIAL SECURITY SURVEY. Genaro Cortez, Safety and Risk Manager 3007 N. Ben Wilson, Ste

Similar documents
Harris County Constable Precinct One - Home Security Survey 1

Residential Security. Audrey Hornbuckle Crime Free Programs Coordinator Defensible Space Team City of Tacoma (253)

Protecting Multi-level Residential Buildings By GERALD A. O ROURKE, CPP

342 Perimeter Security SECURITY SURVEY FORMS

Apartment building safety audit assessment

Secure Residence Initiative ARLINGTON POLICE DEPARTMENT CRIME PREVENTION UNIT

A Checklist for Library Building Security

Make it Hard for Them to Hurt Us. Perimeter

Commercial Properties

GAPS Guidelines THEFT GAP.16.3 INTRODUCTION POSITION. Inventory and Accounting. Physical Security Measures

Security Considerations for Secure Workplaces

Hazlet Township Police

School Property REVIEWING YOUR BUILDINGS & GROUNDS

Property REVIEWING YOUR BUILDINGS & GROUNDS

Window & Door Security

Crime Prevention Through Environmental Design (CPTED) Home Evaluation CPTED Principles

Vacant Building Loss Prevention Best Practices

Introduction. The following five key components, when applied together, serve to help prevent residential burglaries:

Annual Campus Security Report NYU Accra

A.C.E. Security Consultants House of Worship Checklist

Home Security Tips For the Homeowner

Free Advice Free Quote Nationwide. Security Direct property protection. Home Security Buying Guide SECURITY DIRECT.

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

Perimeter Security. Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair.

Why Should You Invest In An Access Management System?

How to Lock Out Crime: Home Security 101

Who is the face behind the mask? Researchers interviewed over 400 career burglars to compile information for this e-book to help us better understand

Pilfergard Door Alarms

Member Meeting January 26 th, 2015

We care about your Safety

IMPORTANT INFORMATION

PHYSICAL SECURITY. Door Security

Shops and Businesses Page 1/5

Residential Burglary Prevention

USD 380 Centralia, Frankfort & Vermillion

Security in museums and galleries: advice for architects and planners

SECURITY AND TOURISM

Do.It.Yourself. Guide FOR

Business Robbery and Burglary Prevention

Architectural Guide /ING BuyLine 4081

HOME SECURITY. 2 - Basic security

(A guide to provide you with ways to improve the security of your home)

Simple Steps That Will Have. Home Security. Checklist

Crime Reduction Advice

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

Workplace Violence Risk Factors and Controls Checklist

Workplace Violence Risk Factors and Controls Checklist

Crime Prevention Through Environmental Design (CPTED) Checklist Instructions

Home Security Check Points

GENERAL GROUNDS. Inspector Name: Inspector Signature:

Chapter 13 Residential Areas: Appendices APPENDIX 1 Residential Areas

Intelligent Keys. A smart solution for recurring revenue

HOME SECURITY INFORMATION

PAMC Facilities employs a locksmith who may be contacted through their main number for the following:

DMPD Burglary Prevention, Personal Property Management and What to do if you are burglarized

Item PZ South Lindbergh Project Overview

FIRE SERVICE FEATURES

Warrington Road Nursery School

Sending the Message. Presented by Alamo Alarm Company. Dear Neighbor,

Community NEWS. Winter Springs Police Department

1.0 Purpose. 2.0 Scope. 3.0 Reference. 4.0 Definitions. University Policy. Keys & Building Access Cards Policy

Safety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance)

DEPARTMENT OF PUBLIC SAFETY

Solutions for Common Problems

CARD ACCESS CONTROL SYSTEM

Fire Risk Assessment Borough High Street

Home security. starts at your. front door

Urban Design Manual 2.0 DRIVE-THROUGH FACILITIES. Background. Urban Design Challenges

How to report a repair

4 January 11, 2012 Public Hearing APPLICANT:

SMART AND BEAUTIFUL. SCALABLE SECURITY SOLUTIONS THAT CAN GROW WITH YOUR NEEDS.

SECTION 15 BUILDING SECURITY. Table of Contents

HOME SECURITY PLANNING CERTIFICATE COURSE Sample Pages

DESIGN REVIEW COMMISSION AGENDA COEUR D ALENE PUBLIC LIBRARY LOWER LEVEL, COMMUNITY ROOM 702 E. MULLAN THURSDAY JANUARY 25, :00 pm

BT SECURITY SECURITY: BEST PRACTICE GUIDE FOR NON-BT PEOPLE

Residential Burglary Prevention

Intruder Alarm Advice for Domestic Properties

Physical Security for Elementary Schools

Project phasing plan (if applicable) 12 copies of site plan

Rapid Entry System KNOX BOX INFORMATION PACKET. Exeter Township Fire Department Office of Fire Codes

About the Instructor & Presenter:

City of Farmington. Downtown Plan. Amendment to the 1998 Master Plan Adopted October 11, 2004

WORKPLACE HAZARDS INSPECTION FORM

INTRODUCTION. A Practical Guide to School Security

INTRUSION SOLUTIONS. Yehans Surveillance & Security Systems. laser perimeter alarming CONTACT US ON

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Product Guide. What is 5LINX Security Systems? Selling Security Systems: Ask the customer. Features and Benefits:

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

Electronic Solutions for Education

Regulatory Reform (Fire Safety) Order 2005

LIGHTNING VAULT WALL MOUNT SINGLE HANDGUN

Deterring Crime Through Design

G4S ACADEMY THE MAMUTE SECURITY ANALYSIS MODEL

MANUAL OF PROCEDURE. Keys and Access Control (Standard and Electronic)

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Cherry Log Christian Church

Southern Baptist Theological Seminary. The Michael Minger Act Report for Activity Reported for Calendar Year 2004

4 September 14, 2011 Public Hearing APPLICANT:

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Moving home Are you really prepared? Written in association with Calvin Beckford, Crime Prevention Specialist.

Transcription:

A COMMERCIAL SECURITY SURVEY PREPARED FOR: The University of Houston - Victoria 3402 N. Ben Wilson Victoria, TX 77901-5731 CONTACT: Genaro Cortez, Safety and Risk Manager 3007 N. Ben Wilson, Ste. 107 361-570-4245 PREPARED BY: Thomas Eisman, Crime Prevention Specialist Victoria Police Department 306 S. Bridge Victoria, TX 77901 361-572-6868 1

INTRODUCTION SECTION ONE At approximately 1400hrs on Tuesday, 05/15/2007 I arrived at 3007 N. Ben Wilson, Suite 107 to begin a Commercial Security Survey the University of Houston, Victoria (Hereafter, UHV). The contact person who requested the survey, Genaro Cortez is the Safety and Risk Manager for the UHV system at this location. Mr. Cortez advised that UHV was interested in improving their security at one of their buildings located at 3402 N. Ben Wilson which houses the Victoria Chamber of Commerce (VCC), the UHV Small Business Development Center (SBDC) and storage for the UHV System. Assisting in gathering information for this survey were: UHV Director of Facilities, Michael E. Ruland; UHV Purchasing Agent, Lydia Huber; SBDC Director, Keith Mudd; and VCC President Randy Vivian. The initial on-site survey concluded at approx 1545hrs, I returned to the location at approximately 2200hrs on Friday, 05/18/2007 to inspect the exterior lighting. IDENTIFICATION OF SITE SECTION TWO The building in question is a single-story office building with storage area in the rear. It is primarily used for the Chamber of Commerce and Small Business Development Center functions of encouraging the economic growth and development of businesses of various types in this community. The building is located in the 3400 block of N. Ben Wilson a five-lane (with left turn lane) street, which has a steady flow of vehicular traffic during normal business hours. Both offices are primarily open to the public and operational from 0800hrs to 1700hrs Monday through Friday with occasional night and/or weekend events. Business History and Crime Status: Both the VCC and the SBDC relocated to this address at the end of October 2006. This survey was prompted by a burglary that occurred the previous weekend. During this burglary, the front door glass of the SBDC was shattered and entry was made in several of the offices throughout the building. Some money and candy was stolen and several electronic items were removed from offices, and then abandoned just outside the building on the North side. Other than this incident, there has been some minor criminal mischief activity to the UHV facilities in the past as well as some minor criminal activity in the surrounding residential areas. PERIMETER BARRIERS SECTION THREE A. EXTERIOR LIGHTING There are various types of lighting throughout the building perimeter and parking area. While this lighting is well placed, it is inadequate to provide safety and security. The current lighting provides only a soft light with poor color rendition to the parking areas. This could make it difficult to accurately describe a criminal seen in the area. The flood lights on the back of the building provide excellent white light, but their angle tends to blind anyone at a distance, thus concealing anyone who may be near the building. 2

Recommendations: Maximum Upgrade all exterior lighting to provide bright white lighting to the parking area and building accesses. Install additional lighting to provide good lighting to all areas around the portable building near the rear of the main building. Adjust the angle of the flood lights in the back of the building to illuminate the building itself. Minimum Upgrade all exterior lighting to provide bright white lighting to the parking area and building accesses. Adjust the angle of the flood lights in the back of the building to illuminate the building itself. B. FENCES, SHRUBS, TREES AND NATURAL BARRIERS There is a wooden privacy fence along the East side of the property with some various vegetation extending over the property from the residential yards. The remaining perimeter is sparsely populated with small vegetation that is not consequential to this study. Recommendations: Monitor the vegetation that is encroaching on UHV property from the residential areas. Make sure this vegetation does not grow to the point of inviting criminals by keeping it neatly trimmed at least 8 off the ground. C. ALARMS (PERIMETER) There is no existing perimeter alarm system. Recommendations: No Recommendations. EXTERIOR BARRIERS A. DOORS SECTION FOUR There are seven entrances into this building. There are two on the South side, two on the West side, two on the North side and one double-door on the East side. The two single, metal doors on the location (one on the North wall, one on the South) have excellent security characteristics and require no changes. Recommendations: Maximum The double-door on the East side of the building poses the largest security risk as they are secluded from visibility and provide ample opportunity for tampering. The doors and door frames should be reworked to include solid core-wood or metal doors in good condition mounted on metal frames or a solid wooden frame with hardened steel strike plates. There should be no gap between the doors and the door jamb. It would be best to change this to a single door, but if the double-door configuration is to be kept, the secondary door should be equipped with header and footer bolts flush-mounted in the door edge that engage metal strike plates in the top and bottom frames. A double-cylinder deadbolt with at least a 1-inch throw should be used on the primary door and all hinges should be peened to prevent tampering. 3

The glass doors on the North and South faces of the building also have limited visibility outside of the immediate area. As such, they should incorporate either safety bars or some type of solid door with door viewers to reduce criminal opportunity. These doors should also have double-cylinder dead-bolts with a 1-inch throw engaging metal strike plates. The front doors of both the SBDC and VCC currently only have a handle-locking system. The VCC door should be equipped with a double-cylinder dead bolt with a 1-inch throw engaging a metal strike plate. The SBDC incorporates a double-door system. The secondary door should be equipped with header and footer bolts flush-mounted in the door edge that engage metal strike plates in the top and bottom frames. A double-cylinder deadbolt with at least a 1- inch throw should be used on the primary door. A metal plate should be attached to the exterior of all doors with deadbolts. These plates should extend beyond the width of the door and extend upward and downward in such a fashion that the deadbolt is concealed when viewed from the exterior of the building. This will protect the deadbolts and strike plates from direct attack. Minimum Reduce or eliminate the gap under the double-doors on the East side of the building to prevent tampering. The secondary door should be equipped with header and footer bolts flush-mounted in the door edge that engage metal strike plates in the top and bottom frames. A double-cylinder deadbolt with at least a 1-inch throw should be used on the primary door and all hinges should be peened to prevent tampering. The front doors of both the SBDC and VCC currently only have a handle-locking system. The VCC door should be equipped with a double-cylinder dead bolt with a 1-inch throw engaging a metal strike plate. The SBDC incorporates a double-door system. The secondary door should be equipped with header and footer bolts flush-mounted in the door edge that engage metal strike plates in the top and bottom frames. A double-cylinder deadbolt with at least a 1- inch throw should be used on the primary door. A metal plate should be attached to the exterior of all doors with deadbolts. These plates should extend beyond the width of the door and extend upward and downward in such a fashion that the deadbolt is concealed when viewed from the exterior of the building. This will protect the deadbolts and strike plates from direct attack. B. WINDOWS The only windows that pose a significant security risk are those on the North face of the building. These are the only windows designed to be opened that are a likely target for a burglar. Recommendations: The windows in question should be equipped with some secondary locking device. This can take the form of a window rail clamp or bar to prevent opening the window should the factory installed locking devise be defeated. C. WALLS The exterior walls of this location pose no significant security risk. Recommendations: No recommendations. 4

D. ROOF There was no easy access to the roof and this did not appear to be a likely ingress point for potential criminals. Recommendations: No recommendations E. FLOOR The foundation is concrete and therefore does not pose a security risk. Recommendations: No Recommendations F. OUTSIDE STORAGE AREAS There is one 30 X 16 portable building near the Southeast corner of the building. This building has no power running to it and is used for storage of items that are not considered likely targets of theft or burglary. Recommendations: Continue to minimize the desirability of breaking into this building by storing more valuable items in the primary building. Improving the security measures on portable buildings only tends to increase the likelihood of damage to said building. No other recommendations. INTERIOR CONTROLS A. DOORS AND LOCKS SECTION FIVE There is a wide variety of both single and double doors inside the primary building. Most are adequate for the purposes they serve. However, areas used for storage of client or member information should be secured any time they are unattended. The areas of primary concern are the SBDC s file room and electronics storage closet and the VCC s office where member information is stored. Recommendations: Maximum All doors into these rooms should be solid core and incorporate deadbolt locks with a minimum 1-inch throw engaging a metal strike plate that is anchored to the wall framing, not the door frame. These locks should be engaged any time the secured areas will be unattended for any length of time. Minimum All doors into these rooms should be solid core and incorporate deadbolt locks with a minimum 1-inch throw engaging a metal strike plate that is anchored to the wall framing, not the door frame. These locks should be engaged any time the respective office is closed to the public. 5

B. INTERIOR WALLS There are very many interior walls. All are constructed of sheetrock over metal studs. The walls are functional and appropriate for their purposes. Recommendations: No recommendations. C. ALARM SYSTEMS There is no internal alarm system. Recommendations: No recommendations. D. SAFES AND SECURED CABINETS There are no safes in the location. The SBDC incorporates a series of locked cabinets containing all client information. These cabinets are currently stored in the HVAC room of the location which has adequate security measures installed at all room accesses. There is one lock box for petty cash kept in the VCC s lobby. The VCC also has a locked file cabinet with Chamber Member information stored in it including some credit card numbers. Recommendations: Maximum It would be best if the SBDC s files could be transferred to digital format on a nonnetworked computer. The information should be stored on electronic media in an appropriate safe with a backup copy stored off-site. As this is not allowed by the SBDC s governing body, the hard copies of this information should all be stored in these cabinets which should only be unlocked when files are actively being accessed. The VCC should not store members credit card information at all. The inconvenience of them having to supply that information annually is offset by the comfort of knowing that the information is not accessible during the rest of the year. The petty cash box situation cannot be improved in any cost-effective manner. Minimum The hard copies of the SBDC s client information should continue to be stored in locked file cabinets which should only be unlocked when files are actively being accessed. The VCC should not store members credit card information at all. The inconvenience of them having to supply that information annually is offset by the comfort of knowing that the information is not accessible during the rest of the year. E. KEY CONTROL There are three primary keys to this building: one which opens the two front doors and an adjoining door shared by the locations, one which opens SBDC office doors and another which opens VCC office doors. Every full-time employee of either location has a front door key and a suite key appropriate to the location they work in. Maintenance and custodial staff have access to master keys for the entire building. 6

Recommendations: Maximum The ideal solution would be to switch to an electronic card-key access either with swipe-cards or proximity keys. These keys would operate either magnetic locks or electronically controlled deadbolts. Such a system would allow specific access limitations applied to keys that could not be easily duplicated and could be easily rendered useless. Such systems preclude employees leaving areas unlocked for various reasons and documents all ingresses and egresses. Minimum Rekey the locks every time an employee leaves the company. Switch to a key that cannot be easily copied. CONCLUSION OVERALL BUILDING SECURITY SECTION SIX Overall this site is a well controlled and safe environment. There is little cause to fear break-ins as the potential gain to the burglar is limited to the information stored in files that a criminal would need to be aware of in advance. There is even less reason to fear that employees will be confronted by a criminal. However, due to the nature of the information stored on site, should it ever be compromised, clients and members are at significant risk of identity theft. If the recommendations in this report are implemented they will help to alleviate some of the weaknesses that still exist at this site. These strategies cannot guarantee a perfectly crime-free environment. Please contact the Victoria Police Department Community Services Section for further information on crime prevention tactics. 7