ULTRA-VIOLET STERILIZATION

Similar documents
ULTRA-VIOLET STERILIZATION

A measured step forward

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

1020 Industrial Drive, Orlinda, TN fax

Professional Amalgam Non-regulated

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

PRINCIPLE MAIN APPLICATION

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

ULTRAVIOLET RADIATION SYSTEMS

PRO Series PRO10 PRO20 PRO30

254 Nanometer Germicidal UV Disinfection Systems

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

AMERICAN AIR & WATER, INC.

Customized Drinking Water

Ultraviolet Air Disinfection Equipment

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

HF Series R_RevB

WEDECO Quadron UV System

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

AEM EASY DRUM M A N U A L

Section 3: Ultraviolet - UV

ULTRAVIOLET PORTABLE AREA SANITIZER

NANO TECH UV-C DISINFECTION SYSTEM

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Ultraviolet Water Sterilizer Installation and Maintenance Manual

UV I UNIT030W / UV I UNIT055W

88MLV Series Open Channel Modular UV Systems

GERMICIDAL ULTRAVIOLET FIXTURES

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

INSTALLATION & MAINTENANCE

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Liquid Storage Tank Conditioners

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

SLT-Series Installation and maintenance instructions

ULTRAVIOLET INDIRECT AIR DISINFECTION

Ultraviolet Disinfection Systems

uv and ozone for commercial pools

Ultraviolet Disinfection Systems

Model RS72. Model RSCS280A. Model RSM2680

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Intensive UV light means not a chance for germs!

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

PURION UV plants for disinfection

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

PCR UV cabinets DNA/RNA

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

Pro-MAX Ultraviolet Sterilizer

ULTRAVIOLET SANITARY CONDIT IONERS

GRU-V Air Purifier. Product Manual

Purifying air at the. Light. speed of. Carrier Corporation 2007 is a member of the United Technologies Corporation family, stock symbol UTX.

Maintenance page 14 Guarantees page 15 BIO-UV Range DESCRIPTION UV10 UV20 UV30 UV40

PCR UV cabinets DNA/RNA

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

Ultraviolet Sterilizers

OWNERS MANUAL. Operation & Installation Instructions LK5-A12, LK5-A22, LK5-A42, LK5-A62, LK6-A12, LK6-A22, LK6-A42, LK6-A62

AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

GERMICIDAL ULTRAVIOLET IRRADIATORS

Water Filter. cover. start button. reminder of cartridge replacement. remainder of life of a cartridge it is time to replace a cartridge

TROJANUVSWIFT SC. Drinking Water Treatment

UV measurements for medical applications using SiC photodiodes

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

UVC/T-M-AR stainless steel UV cabinet

Model D24-1S. Model D24-2S

UV Irreversible Indicators Product Code: UVI-001

PureLine D. Technical Specification

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

ULTRAVIOLET WATER TREATMENT

ADVANCE Ultraviolet (UV) Water Treatment System

PRECAST CONCRETE. Never Looked So Good!

Ultraviolet (UV) Water Treatment System

Document No A3 Revised February Atlantic Ultraviolet Corporation

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd.

Table of contents: Chapter V. V. Disinfection systems DOSADes

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

BestAir. Instruction manual

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

BestAir. Instruction manual

HEPA/UV3 Sterilizing PCR Workstation and Cabinet

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

7000/AP. Ozone Generator Air Purifier / Sterilizer. User Guide

Customer Manual. MADE IN USA Effective

Installation and Maintenance Manual

OWNERS MANUAL. Operation & Installation Instructions

Electro Optical Components, Inc Skylane Boulevard, Suite D, Santa Rosa, CA Toll Free: 855-EOC

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

User s Manual. Purity In Each Drop. Latest RO+UV technology Now at your home

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

MODEL NO. UNIT PRICE FOB SIZE UV A 1/2GPM (6 WATT)

Operation & Installation Instructions

Transcription:

WATERLUX TECNOLOGY UV-C disinfects water by ultraviolet radiation at a wavelength of 254nm. In particular, UV-C inactives and/or destroys the DNA of viruses and bacteria, rendering them ineffective and not harmful to human health, which is the case with other methods of chemical disinfection (eg.cloro, ozone, etc.). Not all organisms respond in the same way if placed under ultraviolet radiation, some become inactive with relatively low doses while others need higher rates to obtain the desired inactivation. This example, indicates the doses of UV-C shown in readings which are used experimentally to inactivate some of the most common organisms: Micro-organisms Escherichia Coli Legionella pneumophila Pseudomonas aeruginosa Salmonella parathypi enteritidis Vibrio cholerae Staphylococcus aerius Streptococcus viridians dose Ws/cm 2 inactivation percentage 90% 2140 3100 5500 3200 3375 2600 2000 99% 4100 5000 10500 6100 6500 6600 3800 Finally to erase all doubts about the efficiency of their products, WATERLUX sterilizers are designed and sized to ensure an average dose of UV-C at a wavelength of 254nm at least 40,000 µws/cm 2.

WATERLUX Technology Factors affecting the UV disinfection The proper use of the WATERLUX sterilizer helps eliminate over 99% of the microbial load in the water. For sizing the equipment to ultraviolet rays and provide any pre-treatment of raw water some important factors must be taken into account as these could affect up to 20%-40% of the germicidal system capacity: TRASMITTANCE This is the transparency of the water through the ultraviolet radiation at a wavelength of 254 nm. By way of illustration, consider that demineralised water has a transmittance of 99%; tap water or filtered well water has a transmittance of about 90-95%, whereas filtered sewage water has a transmittance equal to 60-65%; RADIATION This is the amount of energy radiated by UV lamps and is calculated by the designer of the UV. This energy can vary depending on work conditions: a) Aging of the lamps: after more than 13,000 hours (16,000 for the amalgam lamps) the UV intensity is reduced by at least 20%. Lamps should be replaced even if they continue to stay alight. b) The operating temperature of the lamps: low pressure lamps reach maximum performance in a temperature range between 20 and 50 C. It is obviously necessary to wait for a few minutes (warm up) before achieving maximum germicide capacity. Similarly, if the lamps are working at temperatures greater than 50 C there will be reduced efficiency. The trasmittance essentially depends on: a) Suspended solids, algae, turbidity and organic substances. Suspended particles reflect UV rays (acting as a protective umbrella for microorganisms), or could contain germs which would thus diminish the capacity of sterilizing radiation. It is appropriate that the water entering the UV sterilizers for drinking water has a maximum turbidity of 1 NTU and a maximum of 3 mg / l of suspended solids. Even apparently clear water can filter out UVC rays at 254 nm. b) T.D.S. or salinity of water. Waters full of salts (brackish water and sea water) have the ability to absorb UVC rays, reducing the transmittance. c) Chemical composition of water, hard water (> 35 F), with the presence of iron, manganese, phosphorus, aluminum and biofilm. Within a few days this can make the quartz sleeves opaque, so it is therefore necessary for this to be cleaned periodically to remove any deposits that restrict the propagation of the rays. The WATERLUX installations were rated for raw water with the following chemical-physical parameters: Turbidity Suspended solids Colour Ferro Manganese < 1 NTU < 3 mg/l Absent < 0.3 mg/l < 0.05 mg/l Durezza < 35 F T.D.S. < 2000 mg/l

UV BIO Series BIO series UV systems are very simple and extremely cheap, for a good quality product. Italian product tested and certified in accordance with drinking water regulations. Electric panel according CE standards. Construction characteristics Operating temperature: 2-45 C environment 2-75 C water Max Pressure: 8 bar Pressure drop at max flow rate: 0,2 bar Germicidal lamps Low pressure and high-efficiency 254 nm UVC rays Rated Lamp Life: 9.000/13.000 h Sleeves of pure quartz with high transmittance to UV-C Collector in stainless steel AISI 304 polished and TIG Electric power supply 230V-50Hz Protection rating of electric panel: IP 20 Electronic ballast with LED alarm / fault lamp BIO MIDI BIO MINI

UV BIO series RAY 1 TESTED AND FOR DRINKING WATER CE RTIFIED Specifications Flow / radiation / transmittance Dose 40,000 µws/cm 2 - UVT 95% Dose 40,000 µws/cm 2 - UVT 99% BIO MINI BIO MIDI RAY 1 0,30 0,39 1,2 1,5 2,7 3,2 N lamps Power consumption (W/h) Connections IN-OUT Wheelbase connections (mm) Lamp housing size Height (mm) Ø (mm) Electric Panel Size h x l x p (mm) 1x10W 12 1/4" 165 250 60 90x54x54 1x21W 30 3/4" 380 510 60 120x65x65 1x41W 45 1" 790 930 60 120x65x65

UV LCD Series The new UV sterilizers series LCD, with microprocessor card is suitable to control and view the status of the lamps, the remaining useful life, the total hours of use of the installation, the percentage of radiation (if probe is used), the temperature of the lamp (if probe is used) and the related alarms with adjustable set point. There is also the possibility for the dealer to put his phone number on display on the LCD panel for any service calls from the client. In the terminal there are 2 output relays for remote alarm management. Water supply turn off option in case of system alarm. Italian product tested and certified in accordance with drinking water regulations. Electric panel according CE standards. Equipped with Long Life Lamps 13,000h Construction characteristics Operating temperature: 2-45 C environment, 2-75 C water Max Pressure: 8 bar Pressure drop at max flow rate: 0.2 bar Germicidal lamps Low pressure and high-efficiency 254nm UVC rays Rated Lamp Life: 13.000h Sleeves of pure quartz with high transmittance to UV-C Lamp housing in S.S. AISI 304 polished and TIG welded Electric power supply: 230V-50Hz Protection Rating of electric panel: IP 55 Electronic ballast with LED alarm /fault Electronic board with microprocessor and LCD display UV PRO MIDI LCD - status lamps (Led fault); FUNCTIONS OF LCD PANEL - total lamp on counter (increasing); - partial counter (resettable) with lamp's remaining life (decreasing); - % radiation control to set point percentage with alarm output; - temperature control C with set point and alarm output; - generic alarm relay / dry contact NO/NC; - alarm relay 230V-50Hz NO/NC 2A max; - shutdown for high temperature lamp; shutdown for low radiation / light anomaly; - Option blocking water supply for alarm system. WATERLUX

UV PRO LCD series TESTED AND FOR DRINKING WATER CE RTIFIED UV PRO 1 LCD Specifications Flow / radiation / transmittance Dose 40,000 µws/cm 2-95% UVT Dose 40,000 µws/cm 2-99% UVT N lamps Irradiation/temperature sensor Power consumption (W/h) Connections IN - OUT Wheelbase connections (mm) Lamp housing size Height (mm) Ø (mm) Electric Panel Size h x l x p (mm) UV PRO MIDI LCD 1,2 1,5 1x21W 30 3/4" 380 510 60 160x200x90 UV PRO 1 LCD 2,7 3,2 1x41W 45 1" 790 930 60 160x200x90

UV PRO LCD Series UV PRO 2 LCD - status lamps (Led fault); FUNCTIONS OF LCD PANEL - total lamp on counter (increasing); - partial counter (resettable) with lamp's remaining life (decreasing); Equipped with Long Life Lamps 13,000h - % radiation control to set point percentage with alarm output; - temperature control C with set point and alarm output; - generic alarm relay / dry contact NO/NC; alarm relay 230V-50Hz NO/NC 2A max; - shutdown for high temperature lamp; - shutdown for low radiation / light anomaly; Option blocking water supply for alarm system. WATERLUX

UV PRO LCD series TESTED AND FOR DRINKING WATER CE RTIFIED UV PRO 3 LCD UV PRO 4 LCD Specifications Flow / radiation / transmittance Dose 40,000 µws/cm 2-95% UVT Dose 40,000 µws/cm 2-99% UVT N lamps Irradiation/temperature sensor Power consumption (W/h) Connections IN - OUT Wheelbase connections (mm) Lamp housing size Height (mm) Ø (mm) Electric Panel Size h x l x p (mm) UV PRO 2 LCD UV PRO 3 LCD UV PRO 4 LCD 5 7,1 10 6,1 8,1 13,1 2x41W 3x41W 4x41W 85 128 170 1"1/2 2" 2" 720 720 720 115 115 140 360x270x125 360x270x125 360x270x125

UV PRO LCD Series TESTED AND FOR DRINKING WATER CE RTIFIED UV PRO 6 LCD - status lamps (Led fault); FUNCTIONS OF LCD PANEL total lamp on counter (increasing); - partial counter (resettable) with lamp's remaining life (decreasing); Equipped with Long Life Lamps 13,000h - % radiation control to set point percentage with alarm output; - temperature control C with set point and alarm output; - generic alarm relay / dry contact NO/NC; - alarm relay 230V-50Hz NO/NC 2A max; - shutdown for high temperature lamp; - shutdown for low radiation / light anomaly; - Option blocking water supply for alarm system. WATERLUX

UV PRO LCD series UV PRO 8 LCD Specifications Flow / radiation / transmittance Dose 40,000 µws/cm 2 - UVT 95% Dose 40,000 µws/cm 2 - UVT 99% N lamps Irradiation/temperature sensor Power consumption (W/h) Connections IN-OUT Wheelbase connections (mm) Lamp housing size Height (mm) Ø (mm) Electric Panel Size h x l x p (mm) UV PRO 6 LCD 15 20,5 6x41W 255 3" 640 220 500x400x200 UV PRO 8 LCD 21 28,5 8x41W 340 3" 640 220 500x400x200

ULTRA-VIOLET STERILIZATION UV PRO LCD Series TESTED AND FOR DRINKING WATER CE RTIFIED UV PRO 12 LCD - status lamps (Led fault); - total lamp on counter (increasing); partial counter (resettable) with lamp's remaining life (decreasing); FUNCTIONS OF LCD PANEL Equipped with Long Life Lamps 13,000h - % radiation control to set point percentage with alarm output; - temperature control C with set point and alarm output; - generic alarm relay / dry contact NO/NC; - alarm relay 230V-50Hz NO/NC 2A max; - shutdown for high temperature lamp; - shutdown for low radiation / light anomaly; - Option blocking water supply for alarm system WATERLUX

UV PRO LCD series UV PRO 16 LCD Specifications Flow / radiation / transmittance Dose 40,000 µws/cm 2 - UVT 95% Dose 40,000 µws/cm 2 - UVT 99% N lamps Irradiation/temperature sensor Power consumption (W/h) Connections IN-OUT IWheelbase connections (mm) Lamp housing size Height (mm) Ø (mm) Electric Panel Size h x l x p (mm) UV PRO 12 LCD 30 41 12x41W 510 4" 640 285 800X600X250 UV PRO 16 LCD 40 54 16x41W 680 4" 640 325 800X600X250

WASTE WATER UV WITH AMALGAM LAMPS UV sterilizers with high flow for drinking and waste water. Equipped with low-pressure amalgam lamps with high efficiency and high UVC power. The brand new UV sterilizers with low pressure amalgam lamps are characterized by high power and intensity UV at 254 nm, and a lamp life expectancy of more than 16,000 hours (twice that of normal low pressure lamps). These characteristics are used in particular for installations with medium and high flow rates for waste water where low transmittance (UVT typical 60%) requires a generous dose of UV radiation. The electrical panel is characterized by the programmer UV MONITOR capable of controlling, by means of irradiation sensor/temperature, the following values: -UV dose?ws/cm2 (when connected to a flow sensor); - UV intensity?w/cm2; - Transmittance of the treated water to 254 nm (UVT%); - Water/lamps temperature C ; - Total lamp on counter (increasing); - Partial counter (resettable) with lamp's remaining life (decreasing); - Generic alarm for maintenance with service phone number set on the display. These datas will be UV MONITOR processed to energise the temperature and radiation alarms (with adjustable set point) and eventually block the water supply (eg through the use of an electric valve), lamp cooling, remoted event or start a cleaning cycle with the automatic wiping system (if present). Installations with lamps of 190 W can be fitted (as ) with automatic wiping system for cleaning quartz sleeves; recommended on waste water. Italian product tested and certified in accordance with drinking water regulations. Electric panel according CE standards. - Lamp housing for 190W lamps

UV WITH AMALGAM LAMPS series for clear and waste water Automatic wiping system UV Monitor Lamp housing for 105W lamps Specifications UVPRO 8x105 UVPRO 12x105 UVPRO 16x105 UVWW 4X190 UVWW 6x190 UVPWW 8x190 UVWW 12x190 UVWW 16x190 Flow / radiation / transmittance Dose 40,000 µws/cm 2 - UVT 99% - - - 98 142 200 306 406 Dose 40,000 µws/cm 2 - UVT 95% 39 66 82 74 109 150 225 298 Dose 35,000 µws/cm 2 - UVT 60% 22 36 45 29 43 57 84 101 Max pressure (bar) 8 8 8 8 8 8 8 8 N lamps 8x105W 12x105W 16x105W 4x190W 6x190W 8x190W 12x190W 16x190W Irradiation sensor Temperature sensor Automatic wiping system n.a n.a n.a Power consumption (W/h) 910 1360 1814 820 1250 1640 2500 3300 Alimentazione elettrica 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz 230V - 50Hz Connections IN-OUT 3" 4" 4" DN 100 DN 150 DN 150 DN 200 DN 250 Interasse attacchi (mm) 640 640 640 1400 1400 1400 1400 1400 Lamp housing size Height/ length (mm) 1900 1900 1900 1900 1900 Ø (mm) 220 285 325 220 220 285 325 325 Electric Panel Size h x l x p (mm) 800X600X250 800X600X250 800X600X250 800X600X250 800X600X250 800X600X250 1000X600X250 1000X600X250

WATERLUX SPARE PARTS UVC LAMPS WATERLUX Low pressure mercury arc germicidal lamps, with quadripin socket only on one side. Dosage guaranteed at a wavelength of 254 nm (most effective for disinfection) with efficiency greater than 90%. Duration of more than 13000 hours for Long Life Lamps thanks to a special and exclusive treatment. Duration more than 16000 hours for the amalgam lamps. Code Lamp Type Standard Output Long Life Long Life Long Life Amalgama Amalgama Lamp diameter (mm) 15 5 15 15 15 15 Lamp Length (mm) 212 436 843 843 843 1554 Socket quadripin quadripin quadripin quadripin quadripin quadripin Power (W) 10 21 41 87 105 190 Lamp current (ma) 425 425 425 800 1,2 1,2 UV Intensity 254nm (µw/cm 2 ) 26 72 150 260 320 500 Rated life (h) 9000 13000 13000 13000 16000 16000 QUARTZ SLEEVES Pure quartz sleeves produced by electrofusion. This process allows to maximize transparency to UVC rays and minimize the impurity content. Standard quartz sleeves have one open end. Code Ref model UV Outer diameter Length -Q235 -Q485 -Q900 -Q1600 BIO MINI BIO MIDI UV PRO 1 > UV PRO 16 UVWWx190W (mm) 23 23 (mm) 250 495 23 23 900 1600

WATERLUX SPARE PARTS ELECTRONIC BOARDS AND ELECTRICAL PANELS OTHER PARTS

LAYOUT OF UV PLANT - DIRECT FLOW INFORMATION l. By-pass valve 2. Cartridge filter valve 3. Cartridge filter 4. UV sterilizer drain 5. UV shut-off valve 6. UV shut-off valve 7. Electro valve for blocking water supply with system alarm 8. UVC sensor 9. UV Sterilizer 10. Electrical panel C1. Raw water sample valve C2. Sterile water sample valve LAYOUT OF UV PLANT SYSTEM WITH STORAGE TANK INFORMATION 1 Raw water inlet 2. Raw water storage tank 3. Booster pump 4. Quartz sand/activated carbon automatic filter 5. Cartridge filter 6. Cartridge filter valve 7. By-pass valve 8. UV shut-off valve 9. UV Sterilizer 10. Electro valve for blocking water supply with system alarm 11. UVC sensor 12. Electric panel 13. Filter drain C1. Sterile water sample valve C2. Filtered water sample valve