INSTALLATION DO S AND DON TS

Similar documents
GIVE A FAN A CHANCE Installation Dos & Don ts

Understanding Fan System Effects

SECTION DUCTWORK

Introduction to Fans. The Basics of Fan Principles and Terminology

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Glossary of Terms Laboratory & Fume Exhaust Fans

Twin City Fan & Blower

What is the correct type of fan: Axial, radial, diagonal?

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

DIVISION 15 MECHANICAL


Cool air quietly and efficiently. A guide to buying and operating an air conditioner

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

Furring Channel Resilient Mount - Direct Fixing. Ceiling Systems. intex.com.au / intex.co.nz. Intex

Fan Performance and Selection. Overview

DUCTING FOR HRV SYSTEMS The distribution of airflows

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

SECTION DUCTWORK

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Installation & Maintenance Data IM Contents

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Ventilation Trainer B500

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

Installation and Maintenance Manual IM 1102

Caice Attenuator Selector - Specifier Edition

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

Practical Consideration of Noise from Fans

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

MECHANICAL VENTILATION

Centrifugal Fans, Non-Overloading, Backward Inclined

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

Serenity Series Auto Sensing Everything Bathroom Fan

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

installation, operation & Maintenance manual acb ceiling-mounted cassette models

Fans: Features and Analysis

Myth & Reality of Basement Ventilation

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Twin City Fan & Blower

Modular Supply Make-Up Air Unit

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Air Handling Units. T F E.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award

MIST MAX MODEL MM800. Important: Installation and Operation Manual

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Direct Gas-Fired Make-Up Air

FUME EXTRACT STRATEGY STATEMENT

Air Conditioning Clinic

installation, operation & Maintenance manual Floor-mounted Induction units

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

GAM SERIES INSTALLATION & OPERATING INSTRUCTIONS MULTI-POSITION AIR HANDLER (ELECTRIC HEAT)

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

EqUIPMENT LAYOUT MANUAL

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

Qualification of Fan-Generated Duct Rumble Noise Part 1: Test Facility

VPC Gas Cabinet Heater Range

WHHR Midi & Midi Lite

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Installation Instructions

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

Installation Instructions for Duct Accessories GOLD/SILVER C/COMPACT

Exhaust Duct Design Page 1 of (C)

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

SECTION AIR HANDLING UNIT

CERV Fan and Duct Sizing Information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

AGN 088 Air Flow and Cooling

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

FAN COIL UNITS IMPORTANT NOTE ABOUT EC FAN SPEED CONTROL

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

17 Interior Climate Control

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

Ducted Propeller. Airflow Volume

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

MPA Modular Plenum Array Installation, Operation, and Maintenance Manual

EXHAUST FAN SCHEDULE

Technology for life. Unit heater LH

SECTION (15833) - HVAC POWER VENTILATORS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

5.0 Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Transcription:

4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual or, better still, remote. Figure 4.2. - Volume control dampers Don t site volume control dampers or fittings too close to attenuators as they can cause a dramatic increase in attenuator pressure drop. Allow for a settling duct between volume control dampers and attenuators. FANTECH 2016-11

4.0 NOISE CONTROL (Cont.) Figure 4.3. - Attenuators in relation to bends Don t use attenuator splitters as shown when sited close to a bend as the pressure loss across it will be greater than expected. Do ensure attenuator splitters are in the plane of the bend as shown. Fit turning vanes only if R/W<1.0 Figure 4.4. - Attenuator position relative to axial fans Don t site a rectangular attenuator close to an axial fan intake or discharge. Air is accelerated through an attenuator and fan discharge air is uneven and swirling. Allow adequate distance between attenuators and fan. -12 FANTECH 2016

4.0 NOISE CONTROL (Cont.) Figure 4.5. - Attenuator position relative to axial fan Don t site pod attenuators immediately upstream of the fan as the attenuator pod will block the air flow to fan impeller. However, if the pod is the same size or smaller than the impeller hub bolting directly to the fan is acceptable. Allow one diameter of straight duct between pod attenuator and the fan inlet to ensure impeller obtains an even flow of air. Figure 4.6. - Silencer position relative to centrifugal fans Don t place a rectangular silencer hard against the discharge of a centrifugal fan. Note the splitter orientation. Do place a spacer between the fan and the silencer, and rotate the splitter orientation by 90. FANTECH 2016-13

4.0 NOISE CONTROL (Cont.) Figure 4.7. - Acoustic sealing of silencers to achieve very low noise levels Don t: When trying to achieve very high attenuation or very low noise levels (eg. NR20) do not use an inadequate seal between the silencer and wall opening. Do: lace a concrete sleeve around the silencer to increase the acoustic seal between rooms. For less stringent requirements, pack around the silencer with a resilient material to affect a complete seal between the attenuator and the opening. Figure 4.8. - Isolated walls Isolated Wall Isolated Wall Flexible or resilient seal Don t bridge the isolated wall to the non-isolated wall with the silencer fixings. Do fix the silencer to one wall only, and place a flexible or resilient seal on the isolated wall. -14 FANTECH 2016

4.0 NOISE CONTROL (Cont.) Figure 4.9. - Louvres on Silencer Discharge Don t place a silencer immediately in front of a louvre. Do ensure that the splitter orientation is at 90 to the louvre orientation and place a spacer between the silencer and discharge louvre. Figure 4.10. - Louvres on Silencer Inlet Don t place a silencer immediately downstream of a louvre. Do place a spacer between the louvre and the silencer and ensure that the splitter orientation is at 90 to the louvre orientation. FANTECH 2016-15

4.0 NOISE CONTROL (Cont.) Figure 4.11. - Fan position relative to noise sensitive areas Better Storeroom Better: Do place fans in ceiling spaces away from noise sensitive areas. Best Overlap wrap by 100mm at all joins Do not place fans in ceiling spaces directly above noise sensitive areas. Best: If fan cannot be relocated, wrap fan and surrounding ductwork with a noise barrier material (When wrapping fans pay particular attention to ensuring there are no holes at the joins). Allow sufficient overlap in the wrap to ensure adequate coverage. Remember that flexible connections will be the weakest link. Figure 4.12. - Flanking transmission Attenuator Attenuator Flanking transmission If an attenuator is installed as shown, noise from the fan can bypass the attenuator and enter the conditioned space. This is known as flanking transmission and will negatively impact on the expected attenuator performance. Installing the attenuator through or against the wall minimises the chance of flanking transmission via the duct system ensuring the expected performance is achieved. -16 FANTECH 2016

4.0 NOISE CONTROL (Cont.) Figure 4.13. - Airflow generated noise from silencers Don t select a silencer with high attenuation and low percentage open area without checking the airflow generated noise level. Do check silencer airflow generated noise levels when these conditions occur. If airflow generated noise is too high, try using a longer silencer with a larger open area to get the same attenuation at a lesser airflow generated noise, or acoustically treat the duct after the silencer. As a general rule of thumb, a pressure drop of 30 a should limit the airflow generated noise of a silencer to an acceptable amount in normal office areas. Figure 4.14. - Changing direction of airflow Don't use sharp bends or takeoffs. Do use sweeping bends and takeoffs. Use long chord turning vanes where possible. Keep velocities low to reduce airflow generated noise levels. FANTECH 2016-17

4.0 NOISE CONTROL (Cont.) Figure 4.15. - Reduction of external noise generated from roof units Better Drainage gap Better: Replace windband of fan with silencer. Best In-line Centrifugal When generated noise could be a problem, and a quieter fan cannot be selected. Caution: No acoustic treatment. Best: Change to an inline fan running parallel to the roof, and place a rectangular silencer on the outdoor side. Direct the duct opening away from noise sensitive areas. Figure 4.16. - Reduction of Internal Noise from non-ducted roof units When the fan could exceed the internal background noise, and a quieter fan is not available for selection. lace an acoustic baffle below the fan inlet / discharge. Caution: No Acoustic treatment. -18 FANTECH 2016

4.0 NOISE CONTROL (Cont.) Figure 4.17. - When noise generated by grilles can cause a problem Don't allow high velocity air to pass through grilles. Do ensure velocities through supply and exhaust air grilles are low by increasing the grille size or number of grilles. Size ductwork for constant static pressure to each grille, thus eliminating or minimising the need for balancing damper adjustment (which can generate excessive noise). FANTECH 2016-19