TrueAlarm Smoke Detectors

Similar documents
TrueAlarm Analog Sensing

TrueAlarm Analog Sensing

Multi-Point Peripherals

TrueAlarm ES Analog Sensing

Multi-Point Peripherals

TrueAlarm Analog Sensing

Releasing System Peripherals

TrueAlert Addressable Notification

LifeAlarm Fire Alarm Controls

System Accessories, LCD Annunciators

TrueAlert Addressable Notification Appliances

TrueAlert Multi-Candela Notification Appliances

Addressable Detectors & Bases

TrueAlert Addressable Notification Appliances

Detection and Control Components

IDNet and MAPNET II Addressable Devices

LifeAlarm Fire Alarm Control Panels

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

Multi-Application Peripherals

SECTION FIRE ALARM SYSTEMS

Control Relay Modules

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

TrueAlert Multi-Candela Notification Appliances

TrueAlert ES Addressable Notification Appliances

Fire Alarm System Accessories

Specification/ Data Sheet

Intelligent Detection Devices

S TEM PRODUCT SPECIFICATION

ALK-V PHOTOELECTRIC SMOKE SENSOR

TrueAlert Addressable Notification Appliances

TrueAlert Notification Appliances

4007ES Fire Control Panels

Z-20 Fire Control Panels

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Filtrex A Smoke Detector for Difficult Environments

Conventional Smoke Detectors KFAPO

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

F220-B6PS/M. Installation Guide. Addressable Detector Bases

D250A/D253/D261AW/D280A/D290 Series

Intelligent 2 & 4 Loop Fire Alarm Control Panels

ESL 500N Series Smoke Detector Installation Sheet

4007ES Fire Control Panels

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Addressable Fire Alarm Control Panel

Cerberus FIT conventional system

good things in small packages

Intelligent Single Loop Fire Alarm Control Panel

Open-area Smoke Imaging Detection (OSID)

The new detector from Rafiki

PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS

DS7400Xi Addressable Control/ Communicator

Multi-Application Peripherals and Accessories

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Intelligent Signature Series Analog Detection

Release Control Fire Alarm Systems

4100U City and Relay Cards Installation Instructions

Installation Instructions

E-PDD Duct Smoke Detector Installation Sheet

NBG-12LR and NBG-12LRA

ARCHITECT AND ENGINEER SPECIFICATIONS

FAAST. Fire Alarm Aspirating Sensing Technology

Aspirated Smoke Detectors

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

DCP-FRCME - FAST RESPONSE CONTACT MODULE

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Conventional Detectors

These instructions detail procedures to follow in order to avoid damage to equipment.

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

FAAST. Fire Alarm Aspirating Sensing Technology

Quick Selection Guide Analog Addressable Fire Systems

Consultant Specification AGILE Wireless Fire Detection System

Open-area Smoke Imaging Detection (OSID)

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

Conventional Fire Alarm System Product Range Guide

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

Analogue Detectors. Series 200 plus

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

Agent Release Control Panel

500-IDx Conventional Fire Detectors with Siren!

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

C. All control equipment must have transient protection devices to comply with UL864 requirements.

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

DS160/161 Request To Exit PIR sensors Installation Instructions

TrueAlert Addressable Notification Appliances

intelligent solutions

Reshaping Duct Smoke Detection

Intelligent. Signature Series Multisensor Detection. An EDWARDS brand.

Transcription:

UL, ULC Approved* TrueAlarm Smoke Detectors TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Features detection. If any of these alarm conditions are experienced, an alarm is initiated. Fig 1: A4098-9602 TrueSense Detector Mounted in Base TrueAlarm detection with TrueSense operation combines photoelectric detection with heat detection to provide a multi-mode detector with four detection mechanisms: Stable and reliable photoelectric smoke detection with built-in TrueAlarm sensitivity drift compensation Resettable, thermistor-based fixed temperature detection Resettable, thermistor-based rate-of-rise temperature detection And TrueSense detection, a patented correlation of smoke activity and thermal activity providing intelligent fire detection earlier than with either activity alone Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Operation is for ceiling or wall mounting Multi-function LED indicator: Indicates normal and alarm conditions Provides status during magnetic functional test Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED pulses (normal, more sensitive, or less sensitive) With detectors categorized as normal or needing cleaning or other service, maintenance priorities can be more easily determined Available options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Remote alarm indicating LED Designed for EMI compatibility UL listed to Standard 268 Description Autocall A4098-9602 detectors. Autocall A4098-9602 detectors combine photoelectric smoke detection technology and quick response thermistor-based heat detection technology into a sophisticated, intelligent detector that analyzes each of these activities and their combination to determine whether alarm conditions are present. Four Detection Modes. An onboard microprocessor provides four independent detection modes: photoelectric detection with TrueAlarm sensitivity drift compensation, fixed temperature heat detection, rate-of-rise temperature heat detection, and TrueSense photoelectric/heat trending analysis and alarm TrueAlarm Smoke Detection Features Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity either up or down. Maintained Sensitivity and Dirty Status Indications. With its onboard software compensation, the A4098-9602 maintains its sensitivity much longer in the presence of dust and dirt accumulation. Additionally, it will determine when the dirt accumulation is approaching the limit of compensation, and will indicate that condition via its status indicator LED. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm (see Detector Status LED Indications on page 4). Specifications Specification Voltage Standby Current Alarm Current, 2-Wire Operation Alarm Current, 4-Wire Operation Auxiliary Relay Ratings Rate-of-Rise Temperature Alarm** Table 1: Specifications Rating 15 to 32 VDC, from Control Panel IDC 100 μa @ 24 VDC Up to 86 ma maximum, exact current is determined by alarm current limiting of connected IDC (initiating device circuit) 24 ma typical @ 24 VDC Fixed Temperature Alarm 135 F (57 C) Refer to page 3 under Product Selection 20 F/min (11 C/min), only in effect at temperatures above 90 F (32 C) UL Listed Temp. Range** 32 F to 100 F (0 C to 38 C) Operating Temp. Range 15 F to 100 F (-9 C to 38 C) Storage Temp. Range 0 to 140 F (-18 C to 60 C) Smoke Obscuration Sensitivity Air Velocity Range Humidity Range Color 2.8%/ft Nominal, per UL268 0-2000 ft/min (0-610 m/min) 10% to 95% RH from 32 F to 122 F (0 C to 50 C) Frost White * Additional listings may be applicable; contact your local product supplier for the latest status. AC4098-0017 1/2015

TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Table 1: Specifications Specification Dimensions Rating 4-7/8" Dia. x 2" H, mounted in base (124 mm x 51 mm), refer to p.3 for detail ** Always locate this and all rate-of-rise heat detection devices away from extremes of temperature fluctuation. Page 2 AC4098-0017 1/2015

TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Electronic Heat Detection Fixed Temperature Heat Detection is provided with the addition of a fast response thermistor that causes an alarm at a fixed temperature of 135 F (57 C). Rate-of-Rise Heat Detection occurs at 20 F/min (11 C/min). To minimize the possibility of false alarms, rate-of-rise detection is correlated to the ambient temperature and is only in effect above 90 F (32 C). TrueSense Detection Comparing Photoelectric Activity and Thermal Activity. TrueSense analysis correlates both thermal activity and smoke activity at a single multisensor location using an extensively tested covariance relationship. As a result, TrueSense detection improves response to conditions indicative of faster acting, hot flaming fires when compared to the response of either photoelectric smoke activity or thermal activity alone. High Integrity Detection. TrueSense operation provides early fire detection and maintains the established high level of immunity to false alarms and nuisance alarms that is inherent with TrueAlarm sensor operation. Application Notes Observe heat detector location guidelines. Ambient temperature operating range is 32 F to 100 F (0 C to 38 C). Temperature fluctuations should be below 6 F/min (3.3 C/min). Detector locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, spacing of 30 ft. (9.1 m) may be used as a guide. For additional installation information, refer to Autocall publication 574-709AC, A4098 Detectors, Sensors, and Bases Application Manual. Dimensions and Reference Information Fig 3: A4098-9830 Remote Red LED Alarm Indicator (not to scale) Fig 2: 4098-9832 Adapter Plate and A4098-9602 Dimensions mounted on plate Page 3 AC4098-0017 1/2015

A4098-9602 Product Selection TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection SKU Description Compatibility A4098-9602 TrueAlarm photoelectric detector with TrueSense photoelectric/thermal detection Compatible with bases: A4098-9788, A4098-9682, and A4098-9683 Table 2: Compatible Bases SKU Description Details* A4098-9788 A4098-9682 A4098-9683 2-Wire Base with connections for Remote Alarm LED Indicator 4-Wire Base with Auxiliary Alarm Relay Contacts and connections for Remote LED Alarm Indicator Note: Requires external 24 VDC for operation 2-Wire Base with Auxiliary Alarm Relay & connections for Remote LED Indicator Note: Must be connected as the only device on the IDC to ensure relay operation. IDC and LED connections are screw terminals for in/out wiring, 18 to 14 AWG Relay Ratings, Single Form "C", For Suppressed Loads: Power limited, 3 A @ 28 VDC; Non-power limited, 3 A @ 120 VAC Wiring Connections (In/Out where required): Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG Relay Ratings, Dual Form "C", For Suppressed Loads: Power limited, 1 A @ 28 VDC; Non-power limited, 1/2 A @ 120 VAC Wiring Connections (In/Out where required): Relay contacts and IDC (-), color coded 18 AWG leads; IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Table 3: Detector Accessories SKU Description Details* 4098-9832 Adapter Plate Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes May be used when retrofitting existing bases Compatible with detector bases A4098-9788, -9682, & -9683 A4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate A2098-9739 Encapsulated A2098-9735 Plate Mounted Dimensions: 2-1/2" x 1-1/2" x 1" (64 mm x 38 mm x 25.4 mm) 24 VDC End-of-Line Relay Mounted on single gang stainless steel * Refer to pages 2 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 Detector Status LED Indications plate Required for 4-wire circuits using A4098-9682 base, one per circuit; select mounting type as required; wiring is color coded 18 AWG wire leads LED Indication Pulses approximately every 4 seconds Steady On Status Normal Alarm Page 4 AC4098-0017 1/2015

TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection LED Indication Followed By Status Action LED turns ON LED pulses quickly, 6 times in 3 seconds, then turns ON LED pulses slowly, 4 times in 8 seconds, then turns ON Alarm is initiated Alarm is initiated Alarm is initiated Normal, sensitivity is within compensation range More sensitive, out of normal compensation range Less sensitive, out of normal compensation range None Cleaning or other service is required Does not initiate Alarm Detector is malfunctioning Service is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to application manual 574-709AC for further test and maintenance information. Mounting Information Electrical boxes are supplied by others. Fig 4: Mounting Information Note: Figure 4 shows 4098-9832 adapter plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes. A4098-9682 and A4098-9683 include a relay module that mounts in base electrical box. Figure 4 shows smoke detector bases A4098-9788, A4098-9682, and A4098-9683. Page 5 AC4098-0017 1/2015

Electrical Box Requirements Without relay (base A4098-9788): 4" octagonal or 4" square, 1-1/2" deep Single gang, 2" deep With relay (bases A4098-9682 and A4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). AC4098-0017 1/2015