WHITE PAPER: IBS & IBSB ADVANCED

Similar documents
Dryflex FLAM. Halogen-Free Flame Retardant TPEs

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

NVENT NUHEAT HOME THERMOSTAT Operating Manual

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

NGC-20 LOCAL CONTROL CENTRAL MONITORING

AVAILABILITY EASE OF INSTALLATION SERVICE. SpectraCool Slim Fit Air Conditioner. Easy to Specify and Ready to Use

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

Traction Cable Radox 3 GKW

Standard Universal Sway Brace or Restraint Device Sway Brace Fitting

COMMERCIAL CONSTRUCTION ENGINEERED ELECTRICAL & FASTENING SOLUTIONS COMMERCIAL APPLICATIONS

Varistar LHX 3 Air/Water Heat Exchangers

The Quality Connection. BETAflam Fire Resistant Safety Cables

fire resistant cables

ACS-30-EU-EMDR- 10-MOD

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Fire Safety. Version 1.0

Catalogue Power Cables

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Catalogue. Instrumentation & Control Cables

SAS Security and Alarm Safety Cables

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Catalogue Telecommunication Cables INTRODUCCIÓN

Caledonian Flame Retardant Coaxial Cables

High Performance LSZH Fire Resistant Cable

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Cablosam Tapes for Fire-Resistant Cables

Nuclear Power Plant LSZH Cable Overview

THE TRUE FIRE SURVIVAL CABLE

DNVGL-CP-0399 Edition March 2016

Havells Fire Survival Cables

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Academic and Administrative Buildings

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

55-Gallon Dispenser Package

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

DNVGL-CP-0401 Edition February 2016

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Electrical Preventive Maintenance (EPM) Program

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Compact Module. Category 6A FTP Cabling System 1.1

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

Lexan* Resin 3412R Europe-Africa-Middle East: COMMERCIAL

5 Key Stages to Risk Assessment

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

INDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services

AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE

Carbon Monoxide Safety Information

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

Essential Elements of Fire Safety

Shipboard & Offshore Cables

Generation, Assessment

Lloyd s Register Type Approval System Test Specification Number 3

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

PRODUCT CATALOGUE Norröna

Why is this important?

Photovoltaic Cables EN H1Z2Z2-K

Plug in your cables with BLUESIL

Cooker Hood LA-72-CAN.

Are Electric Cables my biggest Fire Risk?

Single core cables with reduced wall thickness

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

USER S INFORMATION MANUAL

Sensor and transducer cables

OIL & GAS INDUSTRY OTHER INDUSTRIES

Telecommunication Cables

Caledonian Fire resistant Coaxial Cables

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

FIRE RESISTANT CABLES

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Amagasaki, Hyogo Prefecture: Nagasakiya Department Store

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

For Masonry & Factory Built Fireplace Retro-Fits Revised 5 December 2013 Healthy Hearth Riverside Dr. #214 Lake Elsinore, CA 92530

Transcription:

WHITE PAPER: IBS & IBSB ADVANCED Low Smoke, Halogen-Free, Flame Retardant and high temperature flexible power conductor

UNIQUE, SAFE, READY TO USE. In December 2017, an electrical fire below the Atlanta Hartsfield-Jackson International Airport caused both the main power system and backup to fail, causing a power outage for nearly 11 hours. But the risk of electrical fires is not unique to the Atlanta airport, nor is it unique to airports in general. As the volume of power conductors drastically increases across industrial, commercial and residential environments, so too does the demand for manufacturers to choose proper electrical protection for both equipment and people. Fires that involve dangerous plastic can produce toxic fumes, injuring people and damaging equipment As a leader in the electrical power conductor industry, nvent ERIFLEX has worked to meet market needs by developing a unique ThermoPlastic Elastomers (TPE) solution. nvent ERIFLEX IBS & IBSB Advanced combines Low Smoke, Halogen-Free, Flame Retardant (LSHFFR) and high temperature features without compromising the flexibility of their insulated braids. IBS & IBSB Advanced are the ideal readyto-install flexible wire replacement solution. Specifically designed for connections to suit all molded case circuit breakers, IBS & IBSB Advanced has the flexibility to meet a variety of needs. IBS & IBSB Advanced connects to the front access terminals of the breakers without any additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. IBS & IBSB Advanced is formed by weaving high quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility that allows more compact power connections to circuit breakers. IBS & IBSB Advanced allows users to reduce the total size and weight of the installation, reducing labor and improving both design flexibility and assembly aesthetics. IBSB Advanced is intended for applications in which insulation with low toxicity, low smoke generation and low corrosiveness is necessary. Examples of applications like this include: Transportation Datacenters Aviation Industrial environments Subways Buildings Nuclear/Military use Shypyard Public area Wherever human safety and protection of equipment is a primary goal Confined spaces with large amounts of cables near people or electronics 2 nvent.com/eriflex

LOW SMOKE FEATURES IMPROVE SAFETY The low smoke feature of IBSB Advanced allows users to measure the quantity of smoke in cases of emergency such as combustion. This feature is in compliance with various standards and regulations such as IEC and UL to provide the safest low smoke solution. In case of an accident, people must easily locate emergency exits and rescue workers need easy access to the emergency situation. Having low smoke features helps determine the smoke density generated during a fire and allows for the situation to be evaluated properly. IBSB Advanced is also compliant with IEC 60754-2 and UL 2885, meaning the light transmittance improves the visibility to locate the emergency exit and help firefighters work. Flexible insulated braids in PVC ERIFLEX IBSB Advanced IBSB ADVANCED IS COMPLIANT WITH MAIN STANDARDS SUCH AS IEC 60754-2 AND UL 2885 FOR LOW SMOKE FEATURE. Reduction of light transmittance in% Duration Figure 1: Impact of low smoke feature in the reduction of light transmittance. nvent.com/eriflex 3

THE BOOM OF HALOGEN-FREE POWER CONDUCTORS As further chemical research demonstrates halogen materials highly corrosive and toxic nature, the demand for halogen-free solutions has risen to protect both electrical equipment and safety of people. The nvent IBSB Advanced range meets halogen-free requirements for both IEC and UL standards. In the case of a fire, IBSB Advanced does not induce corrosive gases and instead produces mainly steam with a low level of carbon monoxide. Advanced technology contains halogen-free materials and offers better protection for people s safety and your electrical installation by reducing corrosion and smoke generation. Flexible insulated braid PVC ERIFLEX IBSB Advanced Percentage of Halogen Duration Figure 2: Percentage of halogen with IBSB Advanced USING FLAME RETARDANT THERMOPLASTIC NVENT IBSB ADVANCED IS COMPLIANT WITH MAIN STANDARDS SUCH AS : UL94V-0 AND IEC 60695-2-11 GLOW WIRE TEST 960 C FOR FLAME RETARDANT FEATURES IBSB Advanced uses flame retardant thermoplastic technology in compliance with main standards such as UL94V-0 and IEC 60695-2-11 Glow Wire test 960 C. Flame Retardant thermoplastic reduces fire hazards and mitigates danger by delaying 1 4 2 the ignition, reducing the heat dissipation and increasing escape time. It also reduces the damage on electrical installations. The IBSB Advanced is also demonstrated its superior feature with a the Limiting Oxygen Index (LOI) at 30%. 5 3 1 1. Specimen 2. Glow wire 3. Flame 4. Tissue 5. Cotton 4 nvent.com/eriflex

IBSB ADVANCED CLASS II THIS OPERATING TEMPERATURE IS DETERMINED BY THE INSULATION AND/OR SHEATHING MATERIAL AROUND THE CABLE nvent IBSB Advanced is a class II conductor with a high temperature resistance 115 C. This high working temperature reduces the risk of hot points at the connecting area. The operating temperature of an electrical cable normally refers to the minimum and maximum temperature that the cable can safely operate at for a sustained period of time. This operating temperature is determined by the insulation and/or sheathing material around the cable. A typical PVC insulation material has a temperature range of -15 C to 70 C. Class II Conductor 100% nvent.com/eriflex 5

INTEGRAL /SOLID PALM The unique manufacturing process of nvent IBSB Advanced with pure copper and tinned integral/solid palm ensure an optimal connection. The tinned copper offers better corrosion resistance and less maintenance while maintaining a higher electrical conductivity. The tinned copper is compliant with UL standards and also various applications. WORLDWIDE CERTIFICATIONS FOR UNSURPASSED USE IBSB Advanced is a unique, safe and ready to use solution compliant with these main international standards: Visit our website to discover our complete range of certification that may fit to your applications. IBSB ADVANCED IS A UNIQUE, SAFE AND READY TO USE SOLUTION UL Standard IEC Standard Low smoke UL2885 IEC 61034-2 / ISO 5659-2 Halogen-free UL2885 IEC60754-1 / IEC 60754-2 Flame retardant UL94V-0 IEC 60695-2-11 Glow Wire test 960 C 6 nvent.com/eriflex

nvent.com/eriflex 7

Our powerful portfolio of brands: CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER nvent.com/eriflex WARNING: nvent products shall be installed and used only as indicated in nvent s product instruction sheets and training materials. Instruction sheets are available at nvent.com/eriflex and from your nvent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nvent s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 2018 nvent. All nvent marks and logos are owned or licensed by nvent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nvent reserves the right to change specifications without notice. ERIFLEX-WPCS-P14201-IBSBAD-ENUS-1806 P1371W-NAEN