SILVER KING MAJESTIC MILK DISPENSERS MODELS SKMAJ1/2/3

Similar documents
Technical Manual and Replacement Parts List. Cream Dispenser

Technical Manual and Replacement Parts List. Mobile Freezer

Technical Manual and Replacement Parts List. f Real Freezers

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

S6161-ZX-FSE LP

By Silver King Refrigeration, Inc.

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

OVENS, ELECTRIC, CONVECTION, SHIPBOARD; MODELS ECO-6M, ECO-7M, ECO-8M & ECO-9M

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

REF5-BB Undercounter Blood Bank Refrigerator

TABLE OF CONTENTS. Safety Information...3. Installation Instructions...4. Reverse Refrigerator Door...5. Care and Maintenance... 9

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

An Important Message for Installers and Operators IMPORTANT. Model No. Serial No.

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Operation Manual and Parts Directory

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

InstructIon Manual KrEs EQuIPMEnt stands

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Solid Door Top Mount Reach-In Freezer

Chef Base Refrigerators

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Hoshizaki America, Inc.

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Glass Door Merchandiser Refrigerator and Freezer

Water Boilers ME10EN, ME15EN. Table of Contents

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

3.2 CU FT REFRIGERATOR

INSTALLATION AND OPERATION MANUAL

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User s Manual and Operating Instructions

Owner s Guide Installation & Operation

User Manual / Installation Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

REF Series Undercounter Refrigerator

Glass Door Refrigerators

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

INSTALLATION and OPERATION INSTRUCTIONS

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

COMPACT REFRIGERATOR

User Manual. Wine Cellar

Installation and User's Manual for Refrigerator Model SCR33

QA Passed. Inspired living HRF-253 E. OPERATING MANUAL Refrigerator

INSTALLATION and OPERATION INSTRUCTIONS

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

Concepts Serving Systems

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Hoshizaki America, Inc.

Compact Refrigerator. Hoffman Estates, IL Model: cu. ft. Capacity. Installation. This Manual!

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Installation Instructions 36 Inch Refrigerator

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

BR7000SS Fridge for the KC7000SS Kegerator

Countertop Refrigerator

OSD10, OSD20 & OSD30 DRINK DISPENSER

Owner s Guide Installation & Operation

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

Built-in Beverage Cooler CBR901SG. Owner s Manual. For more information on other great EdgeStar products on the web, go to

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Installation & Operation Manual

Installation and Operation Guide For

Upright Freezer 048-GM-48307

Duke Manufacturing Co.

Installation & Operation Manual

Refrigerator / Freezer

SERIES NAV S Display Merchandisers

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

Upright Chiller & Freezer Service, Installation and Care Manual

Wine Cabinet Manual. We know you don t want to read through this manual, but trust us, there is good information in here.

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

Food Waste Disposer Instruction Manual

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Operation Manual and Parts Directory

Viking Installation Guide

User s Manual and Operating Instructions

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Beverage Air IMPORTANT

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Sears, Roebuck and Co., Hoffman Estates, IL 60179

E-Chef Hot Food Table Installation and Operation Manual

Milk, Ice Cream and Milk & Ice Cream Dispensers

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Operation Manual and Parts Directory

Transcription:

S6163-CU-MMC-010 0910-LP-109-2287 TECHNICAL MANUAL FOR SILVER KING MAJESTIC MILK DISPENSERS MODELS SKMAJ1/2/3 DISTRIBUTION STATEMENT C: DISTRIBUTION AUTHORIZED TO U.S. GOVERNMENT AGENCIES AND THEIR CONTRACTORS; ADMINISTRATIVE/OPERATIONAL USE; 1 JUNE 2006. OTHR REQUESTS FOR THIS DOCUMENT MUST BE REFERRED TO NSWC, PHILADELPHIA CODE 944. WARNING: THIS DOCUMENT CONTAINS TECHNICAL DATA WHOSE EXPORT IS RESTRICTED BY THE ARMS EXPORT CONTROL ACT (TITLE 22, U.S.C. SEC. 2751 ET.SEQ.) OR EXECUTIVE ORDER 12470. VIOLATIONS OF THESE EXPORT LAWS ARE SUBJECT TO SEVERE CRIMINAL PENALTIES. DESTRUCTION NOTE: DESTROY BY ANY METHOD THAT WILL PREVENT DISCLOSURE OF CONTENTS OR RECONSTRUCTION OF THE DOCUMENT. PUBLISHED BY DIRECTION OF COMMANDER, NAVAL SEA SYSTEMS COMMAND 15 JULY 2009

Technical Manual and Replacement Parts List Majestic Milk Dispensers MODEL SKMAJ1 MODEL SKMAJ2 MODEL SKMAJ3 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (763) 923-2441 1 Specifications Subject to Change Without Notice.

TECHNICAL MANUAL MAJESTIC SERIES BULK MILK DISPENSERS Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most reliable equipment in the industry today. Please read this manual and the accompanying warranty information before operating your new Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty. Upon delivery of your new Silver King unit, inspect the carton and unit for shipping damages. Report any damage immediately to the transportation carrier and file a written freight damage claim to protect your investment. If a claim is to be filed, save all packaging materials. INSTALLATION The stainless steel exterior of the cabinet has been protected by a plastic covering during manufacturing and shipping. This covering can be readily peeled before installation. After removing this covering, wash the interior and exterior surfaces using a warm mild soapy water solution and a sponge or cloth, rinse with clean water and wipe dry. Drip Tray: Follow the instructions supplied with the drip tray for mounting it to the unit. Location: When locating your new milk dispenser, convenience and accessibility are important considerations, but the following factors must be observed: When placing the unit on a counter, the counter must be able to support a minimum of 300 pounds. When wall mounting the unit, follow the instructions supplied with the wall mounting kit. When placed on a counter, the unit must be on the legs supplied and secured to the counter with the Hold Down Brackets supplied. If the legs are not installed the unit will not operate properly and the warranty will be void. There must be at least four (4) inches of clear space above the unit, two (2) inches on each side and back and open in front. At no time should anything be stored or placed on top of the unit. Correct serving height is important so that those using the dispenser can operate the dispenser properly. The unit must be level. The feet on the front legs are adjustable to aid in leveling the unit. Avoid placing the unit next to an oven, heating element or hot air source which would adversely affect the performance of the unit. Electrical Connections: Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The specifications on the data plate supersede any future discussion. The standard dispenser is equipped with a seven (7) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious injury. The circuit must be protected with a 15 or 20 ampere fuse or breaker. Refrigerant: Use HFC-134A. 1

OPERATION Initial startup: After satisfying the installation requirements, the milk dispenser is ready to start. The unit will start when the power cord is connected to a live electrical receptacle. If the compressor is not running when the unit is initially plugged in, check to make sure that the Temperature Control is not set to the off position. Allow the unit to run a minimum of two hours before loading it with product. Preparation For Use: Once the unit has achieved proper operating temperature, observe the procedures noted in the label on the door liner for loading milk into the milk dispenser. When removing an empty milk krate, be sure to raise the valve arm fully before pulling the milk tube out of the valve. The last half inch of upward valve travel will lock the valve jaw in place and prevent it from coming out of the valve. Temperature Control: The Temperature Control, located on the front of the unit behind the valve splash guard (see label on door liner), is factory set at the midpoint position, which will maintain an average product temperature of around 36-38 Deg F. To access the temperature control, follow the instructions on the door liner. To obtain cooler temperatures turn the Temperature Control stem clockwise and vise versa with a flat blade screwdriver. Allow the unit a minimum of six (6) hours to respond to a control setting adjustment if the product is in the cabinet. Temperature Indicator: The Temperature Indicator, mounted on the door, is factory set to indicate the temperature of the product within two (2) degrees. Should the Temperature Indicator read inaccurately there are instructions for recalibrating it located on the door liner. Defrost: The Silver King Majestic milk dispenser is a manual defrost unit. The unit should be defrosted whenever the walls accumulate a frost bank that is 1/2 inch thick. To defrost the unit, either turn the Temperature Control knob to the off position or disconnect the power cord from the electrical receptacle, and open the door. After the frost has melted or come loose from the cabinet walls, wipe out the cabinet interior. Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit. MAINTENANCE Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of the appliance. Cabinet Surfaces: The cabinet interior and exterior are stainless steel and should be cleaned periodically with a solution of warm water and a mild soap, rinsed and wiped dry with a clean soft cloth. A stainless steel cleaner can also be used. Should a surface become stained or discolored, do not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleaner and rub with the grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners. Valves: To clean the valve start by removing the bottom valve body cap (item 32) by prying it down and off. Remove the valve jaw (item 33) by pushing up through the bottom of the valve and pulling it out the top of the valve. Clean all loose parts and the valve (in place) with a solution of warm water and mild soap or a sanitizing solution and rinsing afterwards. Replace the valve jaw by sliding it into the valve from above and pressing down on the valve jaw until it snaps firmly onto the valve push rod. Replace the bottom valve body cap. Leaking Valves: To stop a valve from dripping milk start by removing the splash guard (item 10) by hand and the apron (item 12) with a Phillips screwdriver. Locate and loosen the adjustment nut and bolt shown in the valve cross section on page 3. Remove the milk tube from the valve. Raise and drop the valve arm (item 34) several times until the valve jaw (item 33) is tight to the front of the valve opening when the valve arm is fully lowered. Re tighten the adjustment nut and bolt and replace the apron and splash guard. Also make sure that the milk tube is cut as close as possible to the valve. MODEL SERIAL NO. DATE INSTALLED 2

REPLACEMENT PARTS DIAGRAM SKMAJ1 3

WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS 4

REPLACEMENT PARTS DIAGRAM SKMAJ2 5

WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS 6

REPLACEMENT PARTS DIAGRAM SKMAJ3 7

WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS 8

FORM NO. 35768 REV A 9

Ref: NAVSEAINST 4160.3A NAVSEA S0005-AA-GYD-030/TMMP NAVSEA/SPAWAR TECHNICAL MANUAL DEFICIENCY/EVALUATION REPORT (TMDER) INSTRUCTIONS: Continue on 8 ½ x 11 page if additional space is needed. 1. Use this report to indicate deficiencies, problems and recommendations relating to publications. 2. For CLASSIFIED TMDERs see OPNAVINST 5510H for mailing requirements. 3. For TMDERs that affect more than one publication, submit a separate TMDER for each. 4. Submit TMDERs at web site https://nsdsa2.phdnswc.navy.mil or mail to: COMMANDER, CODE 310 TMDER BLDG 1389, NAVSURFWARCENDIV NSDSA, 4363 MISSILE WAY, PORT HUENEME CA 93043-4307 1. PUBLICATION NUMBER 2. VOL/PART 3. REV/DATE OR CHG/DATE 4. SYSTEM/EQUIPMENT ID 5. TITLE OF PUBLICATION 6. REPORT CONTROL NUMBER (6 digit UIC-YY-any four: xxxxxx-03-xxxx) 7. RECOMMEND CHANGES TO PUBLICATION 7a. Page # 7b. Para # 7c. RECOMMENDED CHANGES AND REASONS 8. ORIGINATOR S NAME AND WORK CENTER 9. DATE 10. ORIGINATOR S E-MAIL ADDRESS 11. TMMA of Manual (NSDSA will complete) 12. SHIP OR ACTIVITY Name and Address (Include UIC/CAGE/HULL) 13. Phone Numbers: Commercial ( ) - DSN - FAX ( ) - NAVSEA 4160/1 (Rev. 7-2003) S/N 0116-lf-985-4100

FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE INCLUDE COMPLETE ADDRESS USE PROPER POSTAGE FOR OFFICE USE ONLY COMMANDER CODE 310 BLDG 1389 NAVSURFWARCENDIV NSDSA 4363 MISSILE WAY PORT HUENEME, CA 93043-4307 FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE