M-20 Oil Mist Concentration Detection and Alarm Device

Similar documents
CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment

TYPE TESTING PROCEDURE FOR CRANKCASE EXPLOSION RELIEF VALVES JULY 2016

E-17 Flammable Gas Detection and Alarm System

L-08 LIFEBOAT RELEASE MECHANISM

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

Guideline No.: S-02(201510) S-02 Navigation Light and Signal Light Controllers. Issued date: October 20,2015. China Classification Society

C-01 FIRE DECKS AND BULKHEADS

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS)

E-16 Main Engine Remote Control System

Rules for Classification and Construction Additional Rules and Guidelines

F-03 FIXED FIRE DETECTION AND FIRE ALARM SYSTEM

Procedure for the Approval of New Fire Detection and Alarm Technologies

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Code of Practice Version 2 Metal Detection and X-Ray Systems

CONTENTS AUTOMATIC TRANSFER SWITCHES

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

GL-CO-RFG Channel Gas Leak Alarm System

Glass fibre rovings - Non-metallic materials

Warranty Registration

Iranian Classification Society Convention and Legislation Department Code: Tech Contents

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Spark Extinguishing Systems

DiscovR R134a Refrigerant Identifier

Safe Operation Manual. Honeywell IQ Force Gas Detector

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Approval Standard for Electrical Equipment for Use in Hazardous (Classified) Locations - General Requirements

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

State of Nevada Department of Transportation Materials Division

City of Duluth Festival Center 04/25

EU RO Mutual Recognition Technical Requirements

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Operation and Maintenance Manual

CERTIFICATE OF FIRE APPROVAL

Sprinkler Permit Applications

and Refrigerant Identifier

Design Manual Installation Operation Maintenance

Union County Vocational - Technical Schools Scotch Plains, New Jersey

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

100 & 120 Series Pressure and Temperature Switches Safety Manual

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

HYDROGEN DETECTION INSTRUMENTATION FOR THE SIAC HYDROGEN RECOMBINERS. Summary

RESOLUTION MSC.145(77) (adopted on 5 June 2003) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS

Axial flow fan AXICO ANTI-STALL

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

Type UB-2502A and UB-3002A Forced-Air Heater

United Electric Controls One Series Safety Transmitter Safety Manual

SECTION AUTOMATIC TRANSFER SWITCHES

Code for Design of Clean Room

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

COMPANY INTRODUCTION

Pressure Switches Precautions 1 Be sure to read this before handling.

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

PQS Independent type-testing protocol

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Coatings for protection of FRP structures with heavy rain erosion loads

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

SOUND RECEPTION SYSTEM

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

Heating controller with optimisation functions

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Test Unit GTL 100 for Fire Detectors

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

INTERNATIONAL STANDARD

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

SimpleVIS Viscometer Reference Guide P

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Shipboard incinerators with capacities up to 4000 kw

CHEMICAL FUME HOOD PROGRAM

40KMC KMQ

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

INFORMATION BULLETIN No. 150

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

RESOLUTION MSC.188(79) (adopted on 3 December 2004) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS AND SINGLE HOLD CARGO SHIPS

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

GLASS FIBRE REINFORCEMENTS

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

KERN MFB Type MGE Version GB

Transcription:

Guideline No.M-20 (201510) M-20 Oil Mist Concentration Detection and Alarm Device Issued date: 20 th October, 2015 China Classification Society

Foreword This Guideline is a part of CCS Rules, which contains technical requirements, inspection and testing criteria related to classification and statutory survey of marine products. This Guideline is published and updated by CCS and can be found through http://www.ccs.org.cn. Comments or suggestions can be sent by email to ps@ccs.org.cn. Historical versions and release date: Main changes and effective date:

CONTENTS 1 Application...4 2 Basis for approval and inspection...4 3 Terms and definitions...4 4 Plans and documents...4 5 Materials and components...5 6 Design and technical requirements of products...5 7 Selection of typical samples...6 8 Type test...6 9 Unit/batch inspection...9 3 / 10

Oil Mist Concentration Detection and Alarm Device 1 Application This Guideline applies to the approval and product inspection for oil mist concentration detection and alarm device of crank case fitted to marine diesel engine and also applies to oil mist concentration detection and alarm device of gearbox. 2 Basis for approval and inspection 2.1 CCS Rules for Classification of Sea-Going Steel Ships 2.2 IACS/UR/M67 Iacs Type Test Procedure for Oil Mist Detection Monitoring and Alarm Device of Crank Case 2.3 IACS/UR/M10 Explosion Proof for Crank Case of Internal Combustion Engine 2.4 CCS Guideline on Type Approval Test of Electric and Electronic Products 3 Terms and definitions 3.1 The relevant definitions of CCS Rules for Classification of Sea-going Steel Ships apply to this Guideline. 4 Plans and documents 4.1 When applying for approval, applicants are to submit the plans and documents as described below to CCS for approval: 4.1.1 Main product performance specification table; 4.1.2 General assembly plan; 4.1.3 Main parts plan; 4.1.4 Electrical schematic diagram; 4.1.5 Factory test program; 4.1.6 Type test program. 4.2 Plans/documents to be submitted to CCS for information: 4.2.1 Technical standards applicable to products; 4.2.2 Performance test report of first product (if any); 4 / 10

4.2.3 Product Operation Instructions; 4.2.4 Samples of product nameplate, certificate of inspection, etc. 5 Materials and components 5.1 Materials and components mainly include phototube, controller, etc. 6 Design and technical requirements of products 6.1 The detector exposed to the air inside the crank case and diesel engine lubricating oil splash is to be designed and installed in such a way that the suction port of the detector is not covered or blocked under the working condition of continuous splash and spray of the lubricating oil. This design is to be as recommended by the manufacture and approved by CCS, and then expressly indicated in the Operation Instructions to inform the diesel engine manufacturer. 6.2 For the detector exposed to vapor (may affect the sensitivity of the detector) in the air of crank case, verification is to be made to ensure the functions of the detector are not impaired under this working condition. The effectiveness of improvement measures such as heating, etc. is to be tested provided that the exposure to vapor and/or condensate water has been proved to be a possible factor causing malfunction of the detector. Test is to be carried out according to the procedure recommended by the manufacturer and agreed by CCS. Note: This test is done to mainly take into consideration the effect of vapor condensation on the detection on condition that the temperature of detector is lower than that of air in the crank case. 6.3 The detector has connectors connected to the auxiliary devices (e.g. remote display, control relay, etc.), provided that the open-circuit or short-circuit fault of these connectors are not to affect the normal operation of detector. 6.4 The products are to have the function of being tested on board whether they work normally. 6.5 The sampling pipeline and device are to have enough mechanical strength and the capability of high temperature resistance and oil resistance. 6.6 Where the lens are under the worst condition of contamination specified by the manufacturer, the normal use of oil mist concentration detector is not to be affected and functions normally, and appropriate measures are to be taken to clean the lens. 6.7 The equipment for verifying the function of the device is to be provided to control, measure and record oil mist concentration (mg/l) required in this Guideline with an accuracy to ± 10%. The weighing of the filter is to be accurate to 0.1 mg, and the volume of air/oil mist sample is to be accurate to 10 ml. 5 / 10

7 Selection of typical samples 7.1 The oil mist concentration detection and alarm device is generally to be selected from the production line of the manufacturer for the first approval. Two sets of devices are to be selected for the test. One is tested under the condition of clean environment, and the other is tested under the condition representing the worst contamination state of the lens specified by the manufacturer. The sample is to be a representative of the plant in terms of processing capability and manufacturing level, with the same fundamental principle, electrical arrangement and basic functions. 8 Type test 8.1 The oil mist concentration detection and alarm device consists of oil mist detector and monitoring/alarm device. Although the test procedures are intended for oil mist detector, they are also applicable to monitoring/alarm device. 8.2 Type test items are to include: 8.2.1 Appearance inspection 8.2.2 Functional test 8.2.3 Power variation test 8.2.4 Power failure test 8.2.5 Dry heat test 8.2.6 Damp heat test 8.2.7 Vibration test 8.2.8 High voltage test 8.2.9 Insulation resistance test 8.2.10 Static and dynamic inclining tests 8.2.11 Enclosure protection test 8.2.12 Electromagnetic compatibility test 8.2.13 Other test items as considered necessary by CCS or specified in the plans/documents. 8.3 The test condition is to meet the following requirements: 6 / 10

8.3.1 Where the plant laboratory/test bench is used as the site of approval test, the Surveyor of CCS is to check and confirm whether it is satisfactory according to relevant requirements. Otherwise, all tests are to be carried out at the certification/test organization recognized by CCS. 8.3.2 The measuring instrument/meter for the test is to have valid metrological calibration certificate 8.4 Test methods and requirements are to include: 8.4.1 The type test is to meet the following requirements: (1) SAE 80 single-viscosity-grade mineral oil or other similar product is to be selected for oil mist. And an appropriate device is to be used as test container with after supply volume not less than 1 m 3. The maximum size of the oil drop is not to exceed 5 μm. Note: The size of oil drop is to be checked with precipitation method. (2) The oil mist concentration is to be confirmed with weighing method or other equivalent methods. Note: For this test, the difference of weight before and after filtration of 1 m 3 of oil mist by 0.8-μm millipore filter is measured with weighing method to determine the concentration of oil mist. The container of oil mist test is to be fitted with circulating fan. (3) The oil mist is to be sampled according to the specified time interval. And the relationship curve is to be plotted for the measurement result and the output of detector. The oil mist detector is to be close to the place where the oil mist sample is taken out. (4) In the analysis of the oil mist concentration with weighing method, where the calibration curve gradient ascends with the reading of oil mist detection, which is resulted from the incomplete uniform diffusion of oil mist, the measurement result is regarded as invalid and is to be abandoned. All single results lower than 10% below the calibration curve, which is resulted from the destruction of the integrality of filter and not all oil is collected on the filter paper, are to be abandoned. (5) The weighing of the filter is to be accurate to 0.1 mg, and the volume of air/oil mist sample is to 10 ml. (6) The oil mist concentration is to be measured respectively at the top and the bottom of test container. The deviation of results measured at the two positions is not to exceed 10%. (7) The oil mist monitoring equipment is to be able to measure the oil mist concentration within 0 ~ 10% (or x%, corresponding to a percentage not less than two times the setting value for maximum oil mist concentration alarm) lower explosive limit (LEL). Note: LEL corresponds to the oil mist concentration of about 50 mg/l (mass concentration of 4.1%). 7 / 10

(8) Oil mist concentration alarm is to be set to give an alarm with the maximum concentration not exceeding 5% LEL or about 2.5 mg/l. (9) Each type of oil mist detection and alarm device applied for approval by the manufacturer is to be type-tested. Where the detection sensitivity level is adjustable, the test is to be performed at the minimum, middle and maximum set value within the detection range. (10) The oil mist detector is to be installed and tested according to the directions (vertical, horizontal or inclined) on the diesel engine or gearbox in practice. (11) Where the alarm setting value is adjustable, the methods of adjusting and showing the setting point are to be verified according to the Operation Instructions of the manufacturer. (12) Where type approval is required by CCS, the Surveyor or CCS authorized personnel is to witness the test. (13) Multiple tests are to be carried out to verify the repeatability of calibration curve. (14) The following functional tests may be conducted provided that the above requirements have been met and the oil mist concentration gradient curve has been calibrated. 8.4.2 Functional tests are to include: (1) Multi-cylinder detection time interval test The test is conducted to verify whether the multi-cylinder sampling time interval stated by the manufacturer complies with the design requirements. The test environment is to simulate the actual environment of the crank case as applicable. (2) Verification test of deviation between bottom and top oil mist concentration The test is conducted to verify whether the deviation of oil mist concentration at the bottom and the top of test container meets the requirement that the deviation of concentration measured at the two positions is not to exceed 10%. (3) Basic functional test Oil mist or equivalent smoke is generated and input into the oil mist detector, with the concentration controlled to be gradually increased from normal value to alarm point. Check whether the alarm system has early warning and whether it works at the alarm point. (4) Alarm gain adjustment test Change the alarm setting value. Verify adjustment and displaying methods according to the instructions of the equipment manufacturer. Record and confirm whether the oil mist 8 / 10

concentration (or the measured value by standard detector) in the test container at the time is within the range stated by the equipment manufacturer. Note 1: The oil mist monitoring equipment is to be able to detect the oil mist in the air concentration with 0 ~ 10% LEL. Note 2: LEL equals to about 50 mg/l oil concentration (mixture of 13% oil and air). Note 3: Verify that the oil mist concentration alarm device in the air gives an alarm at the maximum setting point (5% LEL or about 2.5 mg/l). Other equivalent methods may be used to make the verification. (5) Electrical fault simulation test Each detector is to be provided with fault indicator indicating power failure of the detector, open circuit or short circuit of the circuit connecting the detector, and the short circuit of the circuit inside the detector, etc. Simulate the electrical fault, and verify whether the alarm indication exists. (6) Alarm time delay verification test (where applicable) Where the oil mist is pumped into the detector through pipelines, the longest and the shortest pipeline recommended by the manufacturer are to be used to verify whether the time delay from the moment the sample oil mist is pumped out from the crank case to the moment an alarm is given is within the range stated by the manufacturer. (7) Lens contamination simulation test Verify if the lens still can meet the functional requirements of the user provided that the lens is under the worst condition of contamination stated by the manufacturer. (8) In addition to the above, after consultation between the Surveyor and the applicant, special and special-shaped products and other test items are to be tested as deemed necessary by CCS or required by plan/technical conditions. 8.4.3 Other electrical test items excluding functional tests are to comply with the requirements of Guideline on Type Approval Test of Electric and Electronic Products (2006). It is recommended that those test items be tested at the test organization recognized by CCS. 9 Unit/batch inspection 9.1 After the type approval is obtained from CCS, the oil mist detector produced by the plant in accordance with the acceptable conditions (including assembly, process, etc.) may be installed on board after passing the unit/batch inspection by CCS. 9 / 10

9.2 After type approval, the plant will be informed in written form of the detailed product inspection method when CCS issues type approval certificate. 9.3 Unit/batch inspection is to be performed according to the items described below. 9.3.1 Functional tests (1) Multi-cylinder detection time interval test (2) Basic functional test (3) Alarm gain adjustment test (4) Electrical fault simulation test (5) Lens contamination simulation test 9.3.2 Electrical tests (1) Power variation test (2) Power failure test (3) High voltage test (4) Insulation resistance test (5) In addition to the above, after consultation between the Surveyor and the applicant, special and special-shaped products and other test items are to be tested as deemed necessary by CCS or required by plan/technical conditions. 9.4 When applying for product inspection, the manufacture is to submit completed inspection reports or documents and product quality certificates. The certificate will be issued after the Surveyor finishes the inspection if CCS requires that the relevant tests be witnessed. 10 / 10