D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

Similar documents
D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Notification Appliance Circuit Module

D7212GV2. Operation and Installation Guide. Control Panel

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

DS7465i. Installation Instructions. Input/Output Module

D2412 Control / Communicator Installation Manual

Installation Guide. Control/Communicator

Battery charger modules

D7053. Installation Instructions Multiplex Input/Output Module

Multiplex Eight Input Remote Modules

D7212 Control/Communicator Operation and Installation Manual

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

D7052. Installation Instructions Multiplex Dual Input Module

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

D2412U, D2412UE Control / Communicator Installation Manual

Operation and Installation Guide. Zone Expansion Module D8125

R A D I O N I C S. D7212 Control/Communicator Operation and Installation Manual B 2/ Radionics

D7044. Installation Instructions Multiplex Single Input Module

AL600ULADA. NAC Power Extender. Installation Guide

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Addressable NAC Output Module D327A

30.45 Electric Release PDRP-2001

XR10/XR20 Command Processor Panels Installation Guide

Control Panels D9412GV4/D7412GV4 v2.03. Installation and System Reference Guide

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

Fire Control/Communicator

FireNET Plus Wiring Instructions

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

D1255RB/D1256RB/D1257RB

AL800ULADA. NAC Power Extender. Installation Guide

TECHNICAL DATA OBSOLETE

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Independent Zone Control (I.Z.C.)

Installation Guide. XRSuper6 / XR20 / XR40

InstallatIon GuIde XR500 series CanadIan ContRol Panel

Booster Power Supply Manual

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Control Panels B5512/B4512/B3512. en UL Installation Instructions

DS7400Xi Addressable Control/ Communicator

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

FMR Installation Instructions. Addressable Fire System Controller

D250A/D253/D261AW/D280A/D290 Series

MR-2602 Two Zone Fire Alarm Control Panel

D7024 Fire Alarm Control Panel

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

D2071A. Operation & Installation Guide Fire Alarm Control Panel

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

LifeAlarm Fire Alarm Control Panels

SENTROL ZX440F. Security System Control. Installation/ Programming

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Duct smoke housings, 4-wire D341/D341P and D342/D342P

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

EVO192 v3.0 Fire and Burglary What s New

PSN-1000 & PSN 1000(E) Installation Manual

Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for models:

INSTALLATION GUIDE XR150/XR550 SERIES CONTROL PANEL

Specification/ Data Sheet

Integrated Security Solutions

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Addressable Fire Alarm Control Panel

Installation Guide for models:

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Model 17A00 Expansion Enclosure

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

SIGA-CC1 Single Input Signal Module Installation Sheet

Release Control Fire Alarm Systems

Integrated Security Solutions

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Series. Access Power Controllers. Installation Guide

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

D2212 Control/Communicator Installation Manual

InstallatIon GuIde XR150fc/XR550fc series Panel

Release Notes for Version 7.05 January 2007

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Remote NAC Power Supply D7038

E S L I N S T A L L A T I O N A N D O P E R A T I O N S M A N U A L ESL Fire Alarm Control Panel ESL

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Transcription:

D9412GV2/D7412GV2 EN Approved Applications Compliance Guide Control Panels

D9412GV2/D7412GV2 Approved Applications Compliance Guide Listings and Approvals Listings and Approvals Fire UL The D9412GV2 and D7412GV2 Control Panels are UL Listed for Central Station, Local, Auiliary, Proprietary, and Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm and Encrypted line Security when communicating via a network. Department of Defense (DOD) The D9412GV2/D7412GV2 was granted approval for Department of Defense (DoD) installations in Sensitive Compartmented Information Facilities (SCIF). 2 Bosch Security Systems, Inc. /08 F01U003639-03

. Contents 1.0 Introduction...4 2.0 Optional Compatible Equipment...4 2.1 Burglary Applications... 4 2.2 Bank Safe and Vault Applications... 4 2.2.1 Control Panel Enclosure Requirements... 4 2.2.2 Battery Connections... 4 2.2.3 Bell Requirements... 4 2.2.4 System Configuration Requirements... 4 2.2.5 Eit Delay... 5 2.2.6 Equipment Requirements... 5 2.2.7 Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel... 5 2.3 Fire Applications... 8 2.3.1 Four-Wire Smoke Detectors... 8 2.3.2 Two-Wire Smoke Detectors... 8 2.3.3 Two-Wire Smoke Detector Specifications... 8 2.3.4 NFPA Style A (Class B ) Circuit... 8 2.3.5 Other Devices... 8 2.3.6 UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B... 9 2.3.7 UL Listed Synchronization (Sync) Modules and Strobes Compatible with the D9412GV2/D7412GV2... 11 2.4 Enclosures... 11 2.4.1 D83 Enclosure... 11 2.4.2 D88A Enclosure... 11 2.4.3 D89 Red Fire Enclosure... 11 3.0 UL/NFPA Compliant Installations... 12 3.1 Required Components... 12 3.2 Installing Combination Fire and Intrusion Alarm Systems... 12 3.2.1 SDI Bus Devices... 12 3.2.2 Zone Bus Devices... 12 4.0 Ground Fault Detect Enable... 13 5.0 Compatible UL Listed Components... 15 6.0 System Wiring Diagrams, Issue A... 16 6.1 D9412GV2 Wiring Diagrams... 16 6.2 D7412GV2 Wiring Diagrams... 19 7.0 Current Ratings Charts... 22 7.1 D8125MUX... 22 7.2 Standby Battery Calculations... 24 8.0 NFPA 72 Fire Alarm Applications... 27 8.1 Household Burglary and Commercial Burglary... 27 8.2 Bank Safe and Vault... 27 8.3 Standby Battery Calculation... 27 8.4 Central Station or Local Systems... 28 8.5 Remote Station or Auiliary Systems... 28 D9412GV2/D7412GV2 Approved Applications Compliance Guide Contents 8.6 Household Fire Warning Equipment... 29 Figures Figure 1: Rothenbuhler 51/4001-42 High Security Bell Wiring Configuration... 6 Figure 2: Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel... 7 Figure 3: Ground Fault Detection... 13 Figure 4: Area 5 Silent Alarm Relay in RPS... 14 Figure 5: D9412GV2 System Wiring Diagram, Power Supply Side... 16 Figure 6: D9412GV2 System Wiring Diagram, Input Points, and Peripheral Devices... 17 Figure 7: D9412GV2 System Wiring Diagram, SDI Devices... 18 Figure 8: D7412GV2 System Wiring Diagram, Power Supply Side... 19 Figure 9: D7412GV2 System Wiring Diagram, Input Points, and Peripheral Devices... 20 Figure : D7412GV2 System Wiring Diagram, SDI Devices... 21 Tables Table 1: UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B... 9 Table 2: Synchronization Module and Strobe Compatibility... 11 Table 3: UL Listed Components Compatible with the D9412GV2 and D7412GV2 Control Panels... 15 Table 4: Current Rating Chart for D8125MUX... 23 Table 5: Current Rating Chart for Standby Battery Calculations... 25 Table 6: Standby Battery Requirements... 27 Table 7: General Ampere-Hour (Ah) Calculation Formula... 27 Table 8: Central Stations or Local Systems Ah Calculation Formula... 28 Table 9: Remote Station or Auiliary Systems Ah Calculation Formula... 28 Table : Household Fire Ah Calculation Formula... 29 Bosch Security Systems, Inc. /08 F01U003639-03 3

D9412GV2/D7412GV2 Approved Applications Compliance Guide 1.0 Introduction 1.0 Introduction The UL System Chart (Table 3 on page 15) references the components that are evaluated and listed by UL for compatibility with the control panel. These components meet the basic system requirements for the applicable standard. The System Wiring Diagrams, Issue A (Figure 5 to Figure on pages 16 to 21) show the relationship between the control panel and the accessory components referred to in Figure 5. 2.0 Optional Compatible Equipment UL Listed components not requiring evaluation for electrical compatibility can be used in many applications when installed according to the manufacturer s instructions. 2.1 Burglary Applications UL Listed burglary alarm sensors not requiring evaluation for electrical compatibility can be used in burglary applications. In some cases, a UL Listed interface module must be used with the sensors. Consult the individual component specification and installation documents to determine suitability. Test Weekly: UL Standard 23 requires a weekly test for residential burglary applications. 2.2 Bank Safe and Vault Applications The UL Listed Model 51 Bell and Model 4001-42 Eternal Line Balancer (both made by Rothenbuhler) must be used for the bell and balanced line module in bank safe and vault applications. Modify the D88A Attack-Resistant Enclosure to meet UL Standard 681. Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault applications. 2.2.1 Control Panel Enclosure Requirements UL Standard 681 for Installation and Classification of Mercantile and Bank Burglary Alarm Systems requires foil lining or equivalent protection of the control unit enclosure. The D88A Attack-Resistant Enclosure does not have a foil lining, but acceptable protection is provided by mounting electronic vibration sensors inside the enclosure. Refer to Figure 1 on page 6. Do not use proimity alarms (capacitance) to protect the control panel enclosure. Install the same electronic vibration sensors in the D88A that are used to protect the safe or vault. Mount the Sentrol 5402, Potter EVD-S, or Arrowhead S-38 electronic vibration detection (EVD) system inside the D88A to meet the UL 681 requirements. Mount the EVD sensor directly inside the metal cabinet of the D88A as shown in Figure 1. Do not install the EVD sensor within 6.4 mm (0.25 in.) of the components or traces of the printed circuit assembly. Install and test the EVD sensor according to the manufacturer s instructions. 2.2.2 Battery Connections Using a D122 Dual Battery Harness, connect two 12 V batteries in the control panel enclosure. Refer to Figure 1 for battery placement information. Use a separate D88A for the 12 V batteries. When using a D122L Dual Battery Harness, wire the batteries in parallel and connect the harness to Terminals 4 and 5 of the control panel. Auiliary power, limited to 300 ma for 72 h, is required for standby. 2.2.3 Bell Requirements Use the following Rothenbuhler bell and balanced line modules with the control panel: UL Listed Model 51 Bell UL Listed Model 4001-42 Eternal Line Balancer Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault applications. 2.2.4 System Configuration Requirements The following configuration and programming options are required for UL Bank Safe and Vault Systems. Refer to the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for programming information. Safe and Vault Protective Circuits To test the devices that protect the safe(s) or vault(s) without sounding the bell, specify the devices points as controlled zones and supervised for trouble conditions. Refer to Point Inde in the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for more information. 4 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment. Bell Configuration UL 365 requires the bell time to be 15 to 30 min. The Rothenbuhler 51 Bell provides selectable bell time through manipulation of its jumpers. Refer to the manufacturer s installation instructions for more information. In addition to the jumper settings inside the bell, you can activate the control panel for a bell time of 15 min. UL 365 requires a Bell Test at arming and must be enabled in control panel programming. Refer to Bell Parameters in the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for more bell time and test programming information. Bell Test To enable the bell test feature, you enable an unused area of the control panel. Enable the bell test feature for the unused area only. Program Relay B as the area bell relay for the unused area. All pass codes that have authority to the safe or vault protection must be valid in this area. Program the area for a fivesecond eit delay. Refer to Figure 1 on page 6 for test connections. To complete the installation for this feature, connect the output to a D133 Relay Module. 2.2.5 Eit Delay The control panel s programmed maimum eit delay must not eceed 30 sec. 2.2.6 Equipment Requirements D9412GV2 or D7412GV2 Control Panel Two (2) D126 12 V, 7 Ah batteries Two (2) D1218 12 V 18 Ah batteries D8132 Battery Charger Module Two (2) D88A Enclosures D122 Dual Battery Harness D122L Dual Battery Harness D133 Relay Module EVD System (Listed Safe/Vault) 2.2.7 Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel Warning: Wear ear protection when installing and testing the Rothenbuhler High Security Bell. Sound levels greater than 95 dba at 3 m ( ft) can occur. 1. Remove all power from the control panel. 2. Use si-conductor 1.2 mm (18 AWG) shielded stranded wire between the control panel and the 51 Logic Board (located in the bell enclosure). 3. If you do not have a Silence switch, temporarily install a 1 Ω resistor across TB1-1 and TB1-6 on the 51 Logic Board. The resistor keeps the 51 s bell silent during the installation and alignment procedures. Also place a temporary wire jumper across the TB1-6 Bell Relay and TB1-7. Refer to Figure 2 on page 7 for wiring a Silence switch. 4. Mount the D88A s 4001-42 Eternal Balanced Line Module and wire it to the 51 Logic Board using two-conductor 0.8 mm (22 AWG) cable. 5. Wire the 4001-42 to the control panel. Refer to Figure 2 and the Rothenbuhler installation manual. 6. Before supplying AC and DC power to the control panel and bell, ensure you are wearing ear protection. The bell sounds for 2 sec and then silences during power up. Bosch Security Systems, Inc. /08 F01U003639-03 5

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment Figure 1: Rothenbuhler 51/4001-42 High Security Bell Wiring Configuration 1 2 3 1 0.64 mm (1/4 in.) minimum distance 4 5 6 7 8 9 + - + - 11 12 11 13 16 14 15 17 1 - Self-contained vibration sensor 2 - Control panel 3 - Accessory modules 4 - High line security module 5-4001-42 Balanced Line Module 6-51 Bell 7 - D133 Relay 8 - Zone input 9 - D122 Battery Harness* * Use a D113 Battery Lead Supervision Module to supervise the battery connections. - D126 Battery 11 - D88A Enclosure 12 - D122L Battery Harness* 13 - Proimity/control unit 14 - Normally open (NO) 15 - Normally closed (NC) 16 - End-of-line (EOL) resistor 17 - Safe 6 Bosch Security Systems, Inc. /08 F01U003639-03

. Figure 2: D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel 4 1 6 5 1 13 2 3 4 2 RED ORG WHT BL K 9 7 9 3 6 7 12 9 8 1 2 3 6 3 11 9 N/O 1 COMM 1 N/C 1 X1 - X1+ 1-51 Logic Board 2-4001-42 Eternal Line Balancing Module 3 - D9412GV2 or D7412GV2 Control Panel 4 - Alarm output 5 - Alternate alarm 6 - Common 7 - +12 VDC Use Terminal 11, 13, 14, 17, 19, 20, or 22. (Select only one.) 8 - Alarm zone input* 9 - kω resistor - Optional Silence switch 11 - D133 Relay Module 12 - BBL In 4 13 - BBL Out 5 14 - Terminal TB1 Bosch Security Systems, Inc. /08 F01U003639-03 7

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment 2.3 Fire Applications UL Listed fire initiating devices not requiring electrical compatibility evaluation can be used in any application. For eample, the four-wire smoke detectors, heat detectors, waterflow switches, and manual pull stations are suitable fire initiating devices. Consult the individual component specification and installation documents to determine suitability. 2.3.1 Four-Wire Smoke Detectors When using four-wire smoke detectors, install a power supervision device according to the manufacturer s instructions. You can connect any number of four-wire smoke detectors to the 9000GV2 Series Control Panels (subject to available auiliary power). The Reset Sensor command is available from the keypads when the Reset Sensor is enabled. Connect the smoke detectors to a suitable interface such as the D125B or D129, or to the D8127/D9127 Modules when used with a D9412GV2 or D7412GV2 Control Panel. Smoke detectors can also be connected to the on-board points to meet UL and NFPA requirements. When using four-wire smoke detectors, install a power supervision unit according to the manufacturer s instructions. Refer to Section 2.3.5 Other Devices. 2.3.2 Two-Wire Smoke Detectors Two-wire smoke detectors connect to the control panel only through the D125B Powered Loop Interface. Two-wire detectors must be evaluated for electrical compatibility, and be UL Listed for use with the control panel. Refer to Table 1 on page 9 for the two-wire smoke detectors that are UL Listed for compatibility and the maimum number of detectors that can be connected to each loop of the D125B Powered Loop Interface Module. You can also consult the smoke detector manufacturer to determine if a particular smoke detector is UL Listed for use with the D9412GV2 and D7412GV2 Control Panels. The Reset Sensor command is available from the keypads when Reset Sensor is enabled. 2.3.3 Two-Wire Smoke Detector Specifications Voltage Range: 8.0 VDC to 14 VDC UL Compatibility Identifier: Type A (for control panel, detector, and base) The control panel does not support multiple detectors in alarm. The control panel is intended to handle detectors with optional features. Detectors from different manufacturers cannot be mied on the same circuit. 2.3.4 NFPA Style A (Class B ) Circuit Loops A and B on the D125B Module are NFPA Style A (Class B ) initiating circuits suitable for connecting any fire alarm initiating device, including two-wire and four-wire smoke detectors. To connect initiating devices to on-board points (1 through 8) on the D9412GV2 or D7412GV2 Control Panel: Use a D125B Powered Loop Interface Module with two-wire initiating devices. Use a D129 Dual Class A (NFPA Style D) Initiating Circuit Module with any type of initiating device, ecept a two-wire smoke detector. Use the following guidelines when connecting fire alarm initiating devices to off-board points: Do not connect two-wire smoke detectors to POPITs or MUX bus inputs. Use the D9127U or D9127T POPIT Modules to connect four-wire smoke detectors when using a D9412GV2 or D7412GV2. 2.3.5 Other Devices Use a D130 Relay Module, D8129 OctoRelay, or Switched Au (Terminal 8) to provide reset capability to other initiating devices such as: D125B Powered Loop Interface Module (2-wire smoke detector module) D129 Dual Class A Initiation Circuit Module (4- wire smoke detector) D9127T/U POPITs On-board points Install devices according to the manufacturer s instructions. Refer to Off-Board Relays in the D9412GV2/D7412GV2 Operation and Installation Guide (P/N: F01U003641). For battery calculations, refer to Table 5 on page 25 and Section 8.0 NFPA 72 Fire Alarm Applications on page 27. Test Weekly: Perform a Fire Test weekly. Both the AC power and battery are tested according to UL 864. 8 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment. 2.3.6 UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B A D125 or D125B Powered Loop Interface Module is required to connect smoke detectors to the on-board points (1-8). Table 1: UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B Manufacturer Detector Model Base Model Maimum Number of Detectors per Loop D125 D125B 12 VDC 12 VDC 24 VDC 1 Bosch Security Systems, Inc. D262 D263 D263TH D263S D263THS D281 D282 D283 D285 D285DH D285TH D340 D286 D603 D604 D605 DS230 DS230F DS233F DS250 DS250TH DS260 DS282 DS282TH DS282S DS282THS DS290 F220P F220PTH F220PC F220PTHC F220-135 F220-135F F220-190F D260 D280 D280 D280 D287, D288 D340 D287, D288 D287, D288 D287, D288 D287, D288 D287, D288 MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL F220-B6 F220-B6 F220-B6 F220-B6 F220-B6 F220-B6 F220-B6 20 2 25 2 80 80 80 1 Requires a UL1481 regulated power-limited Power Supply. 2 Remote Test Station works only when used at 24 VDC. Bosch Security Systems, Inc. /08 F01U003639-03 9

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment Table 1: UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B (Continued) Manufacturer Detector Model Base Model Maimum Number of Detectors per Loop D125 D125B 12 VDC 12 VDC 24 VDC 1 Detection Systems Radionics Honeywell DS200 DS200HD DS230 DS230F DS233F DS250 DS250DH DS250TH DS260 DS282 DS282TH DS282S DS282THS DS290 D262 D263 D263TH D263S D263THS D281 D282 D283 D285 D285DH D285TH D340 D286 D603 D604 D605 TC805C-00 TC804C-01 TC804C-19 System Sensor 1499 2400 2400TH 1451DH MB200-2W MB200-2W MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL MB2W, MB2WL DS290 MB2W, MB2WL MB2W, MB2WL D260 D280 D280 D280 D287, D288 D340 D287, D288 D287, D288 D287, D288 D287, D288 D287, D288 14506587 and 14506587-004 14506587 and 14506587-004 14506587 and 14506587-004 DH400 2 20 2 20 20 2 25 2 60 60 80 80 80 40 40 40 40 40 40 40 1 Requires a UL1481 regulated power-limited Power Supply. 2 Remote Test Station works only when used at 24 VDC. Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment. 2.3.7 UL Listed Synchronization (Sync) Modules and Strobes Compatible with the D9412GV2/D7412GV2 To be UL 864 edition compliant, you must use only these models of synchronization modules and strobes with the D9412GV2 and D7412GV2 Control Panels. Table 2: Synchronization Module and Strobe Compatibility Synchronization Manufacturer Module Model Strobe Model System Sensor MDL S1224MC Wheelock DSM-12/24 RSS-121575-FW RSS-241575-FW Input Power Source Control panel (12 VDC) Eternal power supply (12 VDC)* Eternal power Candelas (cd) Number of Strobes 15 cd 8 15 cd 23 15 cd 50 supply (24 VDC)* 1 cd 28 Control panel 15 cd 4 (12 VDC)* Eternal power supply (12 VDC)* Eternal power supply (24 VDC)* 12 cd 11 75 cd 33 * Requires a UL1481 regulated power-limited Power Supply. 2.4 Enclosures Bosch Security Systems offers three optional enclosures for the control panel. Sections 2.4.1 D83 Enclosure, 2.4.2 D88A Enclosure, and 2.4.3 D89 Red Fire Enclosure describe the three options. 2.4.1 D83 Enclosure The D83 is suitable for residential fire and burglary installations and commercial burglary applications that do not require attack resistance or the approval by Factory Mutual (FM) or New York City Materials and Equipment Acceptance (NYC-MEA). Refer to Table 3 on page 15 for acceptable applications. 2.4.2 D88A Enclosure The D88A is attack resistant and intended primarily for UL commercial burglar alarm and mercantile safe and vault applications requiring a local bell. This enclosure can be used in any burglar or fire alarm application where the D89 Enclosure is suitable. The D88A, with some modification, can be used for bank safe and vault applications as described in Section 2.2 Bank Safe and Vault Applications on page 4. UL lists the D88A for all commercial fire alarm applications. It is approved by FM, CSFM, and the NYC-MEA. 2.4.3 D89 Red Fire Enclosure Generally, the D89 is used for fire alarm applications. UL lists the D89 for all commercial fire alarm applications. It is approved by FM, CSFM, and the NYC-MEA. All references to NFPA and related requirements are based on compliance with the NFPA 72, National Fire Alarm Code. Because installation specifications are generally based on a specific edition of a standard that was legally adopted by the authority having jurisdiction (AHJ), consult with the appropriate AHJ for confirmation. Bosch Security Systems, Inc. /08 F01U003639-03 11

D9412GV2/D7412GV2 Approved Applications Compliance Guide 3.0 UL/NFPA Compliant Installations 3.0 UL/NFPA Compliant Installations 3.1 Required Components To install a D9412GV2 or D7412GV2 that is UL and NFPA compliant, the following items must be included: D89 Red Fire Enclosure D192C or D192G Bell Supervision Module D928 Dual Phone Line Module D8004 Transformer Enclosure Ground Fault Detect enabled on the control panel Refer to Table 3 on page 15 for specific application installation requirements. 3.2 Installing Combination Fire and Intrusion Alarm Systems When installing a combination fire and intrusion alarm system, you must adhere to the following requirements in order to comply with Sections 56.1, 56.2, and 56.4 of the 9 th Edition of UL864. 3.2.1 SDI Bus Devices Keypads (Command Centers) Keypads used eclusively for intrusion system operation are not allowed. Keypads connected to the D9412GV2 and D7412GV2 Control Panels must include the scope of all fire-related points and must be assigned to include Area 1 in the scope. D9131A Parallel Printer Interface Module Do not connect the D9131A Parallel Printer Interface Module to any fire alarm system. The earth ground lug on the printer s electrical cable is not isolated, causing the control panel to be in a ground fault trouble condition. Interface Modules Connect the DX4020 Network Interface Module and the D92B Access Control Interface Module to the SDI bus only if the interface module is located within the control panel enclosure or in a separate enclosure in the same room within 6.1 m (20 ft) of the main control panel. Route all SDI bus wiring in EMT (electrical metallic tubing) conduit. 3.2.2 Zone Bus Devices D8125 POPEX Modules When connecting a D8125 POPEX Module to Zone Bus 1 or 2, D8127U/T or D9127U/T POPIT modules should supervise only all fire or all nonfire devices. Do not connect fire and non-fire devices to the same D8125 POPEX Module. Using Zone Bus 1 eclusively for fire devices and Zone Bus 2 eclusively for non-fire devices is acceptable. D8125MUX Multiple Interface Modules When connecting a D8125MUX module to Zone Bus 1 or 2, all multiple modules should supervise only all fire or all non-fire devices. Do not connect fire and non-fire devices to the same D8125MUX module. Using Zone Bus 1 eclusively for fire devices and Zone Bus 2 eclusively for non-fire devices is acceptable. D8125INV Wireless Interface Module The D8125INV is not listed for commercial fire applications. Do not install a D8125INV on a control panel used for commercial fire applications. D8128D OctoPOPIT Modules If any fire devices are connected to Zone Bus 1 or Zone Bus 2 through the D8125 POPEX Module or D8125MUX Module, all devices connected to all D8128D OctoPOPIT Modules must also be fire points. Do not connect fire and non-fire devices to the same D8128D OctoPOPIT Module. Using Zone Bus 1 eclusively for fire devices and Zone Bus 2 eclusively for non-fire devices is acceptable. Install all D8128D OctoPOPIT Modules used for fire devices within the control panel enclosure or in a separate enclosure in the same room within 6.1 m (20 ft) of the main control panel. Route all Zone bus wiring in EMT (electrical metallic tubing) conduit. D8129 OctoRelay Modules If any fire devices are connected to Zone Bus 1 (or Zone Bus 2), you must use all D8129 OctoRelay Modules connected to Zone Bus 1 (or Zone Bus 2) only for fire applications. Install all D8129 OctoRelay Modules used for fire devices within the control panel enclosure or in a separate enclosure in the same room within 6.1 m (20 ft) of the main control panel. Route all Zone bus wiring in EMT (electrical metallic tubing) conduit. 12 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 4.0 Ground Fault Detect Enable. Auiliary (AUX) Power Terminals If any fire device is connected to an auiliary (AUX) power terminal on the control panel, do not connect any non-fire device to the same AUX power terminal. For eample, if a four-wire smoke detector is connected to Terminal 8 (SWITCHED AUX), no other non-fire devices can be connected to the same terminal. 4.0 Ground Fault Detect Enable To enable the Ground Fault Detect Enable feature: 1. Lock (close) the S4 Ground Fault Detect Pin on the control panel as shown in Figure 3. If your control panel has Version 7.02 firmware or below, you must do Step 2. Figure 3: 3 Ground Fault Detection 1 2 GROUND FAULT DETECT Enabled Disabled RED TIP PHONE LED S4 ON when communicating OFF when idle PHONE LINE SEIZED TELCO CORD MODEL D161 RING 2. Program the Area 5 Silent Alarm Relay to a nonzero value (1 to 128). In remote programming software (RPS), the Area 5 Silent Alarm Relay is located in RELAY PARAMETERS, Area Wide Relays, and Silent Alarm Area 5 as shown in Figure 4. For more information, refer to the D9412GV2/D7412GV2 Operation and Installation Guide (P/N: F01U003641) and the D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636). 1 - With S4 closed, control panel detects ground faults. 2 - With S4 open, control panel does not detect ground faults. 3 - S4, Ground fault detect enable. Bosch Security Systems, Inc. /08 F01U003639-03 13

D9412GV2/D7412GV2 Approved Applications Compliance Guide 4.0 Ground Fault Detect Enable Figure 4: Area 5 Silent Alarm Relay in RPS 14 Bosch Security Systems, Inc. /08 F01U003639-03

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 5.0 Compatible UL Listed Components 5.0 Compatible UL Listed Components In Table 3, the tet in the columns and rows has the following meanings: No = Not acceptable for this application Req. = Required for this application Opt. = Optional for this application. [Empty bo] = Not used for this application Table 3: UL Listed Components Compatible with the D9412GV2 and D7412GV2 Control Panels Household Burglary Household Fire Minimum Hours of Standby Battery 4 24 + 4 min alarm Household Fire/ Burglary Combined Central Station Burglary Police Connected Burglary Local Burglary Local Fire/Burglary Combined Local Fire 4 4 4 24 + 5 min alarm D83/D89 Enclosure Opt. Opt. Opt. Opt. No Opt. No Opt. Opt. No No Opt. No D88A Enclosure Opt. Opt. Opt. Opt. Req. Opt.. Req. Opt. Opt. Req. Req. Opt. Opt. D125B Class B, Style A Powered Loop Interface* D129 Class A, Style D Initiating Module* Local and Central Station Fire Combined Local and Central Station Fire/ Burglary Central Station Fire/ Burglary Combined Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D928 Dual Phone Line Module Opt. Opt. Opt. Opt. Opt. Opt. Required if using two telephone lines for communication. D192G Class B, Style Y Bell Circuit Supervision D268/D269H Independent Zone Control Opt. Opt. Opt. Opt. Opt. Opt. Req. Req. Req. Req. Req. Req. Optional. Only connect to Zones 1 to 8. No No No No No No No DS7432 Eight Input Remote Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. DS7457iF Single Zone Input Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. DS7560i Dual Zone Input Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. DS7461i Single Zone Input Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. DS7465i Input/Output Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D130 Relay Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D1255 and D1260 Keypads Opt. Opt. Opt. Opt. Opt. Opt. No No No No No No No D1256 Command Center and D1257 Annunciator Opt. Opt. Opt. Opt. Opt. Opt. No No No No No No No D1255B and D1260B Keypads Opt. Opt. Opt. Opt. Opt. Opt. No No No No No No No D1255RB, D1256RB, D1257RB No Opt. Opt. No No No Req. Req. Req. Req. Req. Req. D1640 Transformer Required for all applications. D8004 Transformer Enclosure Opt. Opt. Opt. Opt. Opt. Opt. Req. Req. Req. Req. Req. Req. D8125 Class B, Style 4.0 POPEX Required for the D9127T/U POPITs. Module D8125MUX Class B, Style 4.0 Required for MUX devices. Refer to Section 7.1 D8125MUX on page 22. D9127T/U Class B, Style A POPIT Modules Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D8128D OctoPOPIT Opt. No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D8129 OctoRelay Optional. For remote annunciation of system functions. D8130 Release Module Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D8132 Battery Charger Refer to Table 5 on page 25. No No No No No No No D9131A Parallel Printer Interface Opt. No No Opt. Opt. Opt. No No No No No No Opt. D92B Access Control Interface No No No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. No * The D125B is required to connect two-wire fire alarm initiating devices. The D125B provides two powered loops for connecting listed two-wire smoke detectors. The D129 provides two non-powered Class A initiating circuits. Central Station Fire Electrically Actuated Transmitter Bosch Security Systems, Inc. /08 F01U003639-03 15

PHONE LINE SEIZED RED GRN D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A 6.0 System Wiring Diagrams, Issue A The System Wiring Diagrams, Issue A (Figure 5 on page 16 to Figure on page 21) show the relationship between the control panel and the accessory components referred to in Table 3 on page 15). 6.1 D9412GV2 Wiring Diagrams Figure 5: D9412GV2 System Wiring Diagram, Power Supply Side D113 BAT 2- CHGR- BAT 2+ BAT 1- BAT 1+ VAUX+ SUPV CHGR+ - + - + 3 2 4 2 2 5 - + - + 2 2 8 AUX PWR ALARM TRIG COM SUPV IN ALARM CKT 6 + - 6 9 7 6 CLASS 2 TRANSFORMER 1 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet 2 Do Not Share With Other Equipment 3 + AUX POWER 4 BATTERY NEGATIVE ONLY Maimum Charging Current 1.4 Amps. 5 BATTERY POSITIVE ONLY PROGRAMMABLE 6 RELAY A ALARM OUTPUTS Terminals 7 RELAY B 6 and 7 SWITCHED AUX Terminal 8 RELAY C 8 9 COMMON EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 Point 8 S3 Option D9412GV2 D5200/D5360 PROG CONN 11 D928 6 14 6 6 TIP TELCO ON when PHONE communicating LED OFF when idle PHONE LINE SEIZED TIP TELCO CORD MODEL D161 RING RING 11 12 13 14 15 16 Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Bo 220 KΩ 13 12 15 16 1 - If required by local AHJ, connect D113 Battery Lead Supervision Module. 2 Batteries 3 - D122 Dual Battery Harness, as required 4- D1640 Transformer and D8004 Transformer Enclosure required for NFPA Applications 5 - D8132 Dual Battery Charger with two batteries (Batteries are not supervised.) 6 - Power limited, supervised 7 - Power limited 8 - To Relay A or Relay B 9- To Relay A or Relay B - Listed Audible Signaling Devices rated at 12.0 VDC nominal (Do not use vibrating type horns.) 11- C900V2 or C900TTL-E (optional) 12- RJ31X, jack 13-560 Ω, 2 W EOL Resistor (P/N: 15-03130-005) 14- RJ31X, secondary phone line 15- RJ31X, primary phone line 16- To earth ground All eternal connections ecept Terminal 5 (battery positive) are power limited. 16 Bosch Security Systems, Inc. /08 F01U003639-03

RED D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A. Figure 6: D9412GV2 System Wiring Diagram, Input Points, and Peripheral Devices 1 2 3 4 5 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER BATTERY NEGATIVE ONLY Maimum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY D9412GV2 6 7 8 RELAY A RELAY B RELAY C PROGRAMMABLE ALARM OUTPUTS Terminals 6 and 7 SWITCHED AUX Terminal 8 9 COMMON + - EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 VOLTAGE RANGES Open 3.7-5.0 VDC Normal 2.0-3.0 VDC Short 0.0-1.3 VDC Point 5 Point 6 Point 7 Point 8 Point 8 S3 Option D5200/D5360 PROG CONN D130 ON when PHONE communicating LED OFF when idle PHONE LINE SEIZED TIP TELCO CORD MODEL D161 RING 11 12 13 14 15 16 17 18 19 20 21 22 Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Bo 220 KΩ GRN PHONE LINE SEIZED TIP RING TELCO P5F P5BL D125B Sw. Au Pwr 1 Zone B 2 Zone A 3 Pnl Common 4 Pnl Common 5 Loop B- 6 Loop A- 7 Loop B+ 8 Loop A+ 9 Earth Ground D129 Loop B+ Loop B- Loop B- Loop B+ Zone B Au Power Earth Ground Common Zone A Loop A+ Loop A- Loop A- Loop A+ 1 2 3 4 5 6 7 8 9 11 12 13 1 - (Optional): For 24 V applications use a UL Listed 24 VDC requires a regulated powerlimited Power Supply, with a D130 Relay Module. Refer to the D130 Installation Instructions (P/N: 74-06262-000) for correct wiring requirements. 2 - D125B Powered Loop Interface Module 3 - To UL Listed two-wire smoke detectors. Refer to Section 2.3.2 Two-Wire Smoke Detectors on page 8 for information and Table 1 on page 9 for a listing of compatible two-wire smoke detectors. 4 - P5 1 kω EOL resistor (P/N: 14-03130-004): Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 5 - P5BL1 1 kω EOL resistor: For typical burglar alarm applications. 6 - D129 provides optional Waterflow Alarm Retard feature. Not suitable for two-wire smoke detectors. Use zero retard ecept for waterflow devices. All eternal connections ecept Terminal 5 (battery positive) are power limited. Bosch Security Systems, Inc. /08 F01U003639-03 17

GRN D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure 7: D9412GV2 System Wiring Diagram, SDI Devices D9412GV2 PERIPHERAL DEVICE CONNECTIONS RED POWER + 32 YELLOW DATA BUS A 31 GREEN DATA BUS B 30 BLACK COMMON 29 N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX OUT 1 28 ZONEX IN 1 27 ZONEX OUT 2 26 ZONEX IN 2 25 ZONEX POWER + 24 ZONEX COMMON 23 Point 8 S3 Option D5200/D5360 PROG CONN Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Bo 220 KΩ + - + - 1 - Up to eight supervised D1255RB, D1256RB, D1255, D1256, D1260B, or D1260 Keypads, or D1257RB or D1257 Fire Annunciators 2 - Up to 8 D92B Access Control Interface Modules 3 - Up to 3 supervised 9131A Parallel Printer Interface Modules, or other SDI devices 4 - Power limited, supervised 1 5 - Power limited 6 - D9133TTL-E or DX4020 Network Interface Module or other SDI device Fire and Burg devices must be on separate circuits. 1 2 7 - D8125 POPEX No.1 8 - D8125 POPEX No. 2 9- Up to 119 D9127U/T POPITs or up to 63 D8127U/T POPITs - Zone 1: 15 D8128Ds 2 11 - Zone 2: 15 D8128Ds maimum 2 12 - Zone 1: Up to 8 D8129s maimum 2 13 - Zone 2: Up to 8 D8129s maimum 2 The number of D8129 OctoRelays that can be connected to each zone terminal on the control panel is limited by the number of D8128D OctoPOPITs connected to the same terminal. Refer to the D8128D Installation Guide (P/N: 41242) or the D8129 Operation and Installation Guide (P/N: 74-04562-000) for specific information. Do not connect the D9131A to systems that require Commercial Fire listings. The electrical ground on the D9131A does not isolate earth ground. All eternal connections ecept Terminal 5 (battery position) are power limited. 18 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0. 6.2 D7412GV2 Wiring Diagrams System Wiring Diagrams, Issue A Figure 8: D7412GV2 System Wiring Diagram, Power Supply Side BAT 2- BAT 2+ BAT 1- BAT 1+ CHGR- VAUX+ SUPV CHGR+ 3 5 4 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D7412GV2 BATTERY NEGATIVE ONLY 6 Maimum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A PROGRAMMABLE ALARM OUTPUTS AUX PWR ALARM TRIG COM + SUPV IN ALARM CKT 4-4 7 RELAY B RELAY C COMMON EARTH GROUND Terminals 6 and 7 GROUND FAULT DETECT Enabled Disabled SWITCHED AUX Terminal 8 Point 1 Point 2 Point 3 Point 4 8 D928 4 PHONE RED LED TIP ON when communicating OFF when idle PHONE LINE SEIZED TELCO RING 11 12 13 14 15 16 9 4 4 12 PHONE LINE SEIZED TIP TELCO RING 11 13 14 1 If required by local AHJ, connect D113 Battery Lead Supervision Module. 2 Batteries 3 - D122 Dual Battery Harness, as required 4 - Power limited, supervised 5 - Power limited 6 - D192G Bell Supervision Module 7- To Relay A or Relay B 8- Listed Audible Signaling Devices rated at 12.0 VDC nominal (Do not use vibrating type horns.) 9- C900V2 or C900TTL-E (optional) - RJ31X, jack 11-560 Ω, 2 W EOL Resistor (P/N: 15-03130-005) 12- RJ31X, secondary phone line 13- RJ31X, primary phone line 14- To earth ground All eternal connections ecept Terminal 5 (battery positive) are power limited. Bosch Security Systems, Inc. /08 F01U003639-03 19

D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure 9: D7412GV2 System Wiring Diagram, Input Points, and Peripheral Devices CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D7412GV2 BATTERY NEGATIVE ONLY Maimum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C PROGRAMMABLE ALARM OUTPUTS Terminals 6 and 7 SWITCHED AUX Terminal 8 COMMON + - EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 VOLTAGE RANGES Open 3.7-5.0 VDC Normal 2.0-3.0 VDC Short 0.0-1.3 VDC Point 5 Point 6 Point 7 Point 8 RED PHONE LED ON when communicating OFF when idle PHONE LINE SEIZED TIP TELCO CORD MODEL D161 RING 11 12 13 14 15 16 17 18 19 20 21 22 PHONE LINE SEIZED TIP RING TELCO Sw. Au Pwr 1 Zone B 2 Zone A 3 Pnl Common 4 Pnl Common 5 Loop B- 6 Loop A- 7 Loop B+ 8 Loop A+ 9 Earth Ground Loop B+ Loop B- Loop B- Loop B+ Zone B Au Power Earth Ground Common Zone A Loop A+ Loop A- Loop A- Loop A+ 1 2 3 4 5 6 7 8 9 11 12 13 1 - (Optional): For 24 V applications use a UL Listed 24 VDC regulated power-limited Power Supply with a D130 Relay Module. Refer to the D130 Installation Instructions (P/N: 74-06262- 000) for correct wiring requirements. 2 - D125B Powered Loop Interface Module 3 - To UL Listed two-wire smoke detectors. Refer to Section 2.3.2 Two-Wire Smoke Detectors on page 8 for information and Table 1 on page 9 for a listing of compatible two-wire smoke detectors. 4 - P5 1 kω EOL resistor: Suitable for nonpowered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 5- P5BL1 1 kω EOL resistor: For typical burglar alarm applications. 6 - D129 provides optional Waterflow Retard feature. Not suitable for two-wire smoke detectors. Use zero retard ecept for waterflow devices. All eternal connections ecept Terminal 5 (battery positive) are power limited. 20 Bosch Security Systems, Inc. /08 F01U003639-03

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 Figure : D7412GV2 System Wiring Diagram, SDI Devices System Wiring Diagrams, Issue A D7412GV2 PERIPHERAL DEVICE CONNECTIONS PERIPHERAL DEVICE CONNECTIONS RED POWER + RED POWER + YELLOW YELLOW DATA BUS A DATA BUS A GREEN GREEN DATA BUS B DATA BUS B BLACK BLACK COMMON COMMON NFPA Style NFPA3.5 Signaling Style 3.5 Line Signaling Circuits Line Circuits ZONEX OUT 1 ZONEX OUT 1 ZONEX IN 1 ZONEX IN 1 NOT USED 26 NOT USED 25 ZONEX POWER + 24 ZONEX COMMON 23 Point 8 S3 Option D5200/D5360 PROG CONN Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Bo 220 KΩ GRN + - 1 - Up to eight supervised D1255RB, D1256RB, D1255, D1256, D1260B, or D1260 Keypads, or D1257RB or D1257 Fire Annunciators 2 - Up to 8 D92B Access Control Interface Modules 3 - Up to 1 supervised 9131A Parallel Printer Interface Module, or other SDI device 4 - Power limited, supervised. Fire and burg devices shall be on separate circuits. 5 D9133TTL-E or DX4020 Network Interface Module or other SDI device 6 - D8125 POPEX No.1 7 - Up to 67 D9127U/T POPITs or up to 63 D8127U/T POPITs 8 - Zone 1: Up to 9 D8128Ds* 9- Zone 1: Up to 8 D8129s maimum* * The number of D8129 OctoRelays that can be connected to each zone terminal on the control panel is limited by the number of D8128D OctoPOPITs connected to the same terminal. Refer to the D8128D Installation Guide (P/N: 41242) or the D8129 Operation and Installation Guide (P/N: 74-04562-000) for specific information. Do not connect the D9131A to systems that require commercial fire listings. The electrical ground on the D9131A does not isolate earth ground. All eternal connections ecept Terminal 5 (battery positive) are power limited. Bosch Security Systems, Inc. /08 F01U003639-03 21

D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Ratings Charts 7.0 Current Ratings Charts 7.1 D8125MUX Complete the chart in Table 4 to determine the maimum currents for the D8125MUX and its accessories. Transfer the total figures to Table 5 on page 25. The maimum current draw for each MUX Bus is 75 ma. 22 Bosch Security Systems, Inc. /08 F01U003639-03

. Table 4: D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Rating Chart for D8125MUX Current Ratings Charts Accessory Module DS7432 DS7457i DS7460i DS7465i AC Power Off Maimum Current (ma) Used Each Unit Total System Each Unit In Alarm Maimum Current (ma) Total System = = 0.35 = 0.35 = 1 = 1 = 1 = 1 = Ratings of other devices on the MUX Buses that are not shown above*: * Refer to the device s installation guide for current draw values. = = = = = = = = = = = = = = = = = = = = = = = = = = = = Column A Total = Column B Total = Bosch Security Systems, Inc. /08 F01U003639-03 23

D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Ratings Charts 7.2 Standby Battery Calculations Table 5: Current Rating Chart for Standby Battery Calculations Model Number D9412GV2/ D7412GV2 D125B D127 D129 D185 D192G D1255/D1255B D1256/D1257 D1255RB D1256RB D1257RB D1260/D1260B D720 D8125 D8125MUX 1 D8128D D8129 D8130 D9127T/U D9131A D92B Used A B C AC Power On Normal Current (ma) AC Power Off Minimum Current (ma) Each Unit 1 Total Each 1 Total Unit In Alarm Maimum Current (ma) Eac h Unit 1 225 1 = 225 225 1 = 225 300 1 = 300 25 5 23 245 35 4 4 4 4 4 140 20 60 25 20 7 0.8 21 1 Total = 25 = 168 = = 5 = 55 = = 23 = 25 = = 245 = 300 = = 35 = 0 = = 6 = 206 = = 6 = 206 = = 6 = 225 = = 6 = 225 = = 6 = 225 = = 140 = 250 = = 20 = 0 = = 60 = 60 = = = = = 25 = 50 = = 20 = Refer to footnote 2 = = 7 = 60 = = 0.8 = 0.8 = = 21 = 23 = = 1 = 1 3 = 24 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Ratings Charts. D928 20 = 20 = 0 = DX40i 50 = 50 = 55 = DX4020i 80 = 80 = 84 = Ratings of other devices in the system that are not shown above: = = = = = = = = = = = = = = = Total A = Total B = Total C = 1 Refer to Table 4 on page 23 to determine maimum currents for the D8125MUX and its accessories. 2 The In Alarm calculation for the D8129 is: 20 + (16.25 number of relays) 3 Use 1 ma + reader current. Do not eceed 260 ma. Bosch Security Systems, Inc. /08 F01U003639-03 25

D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0 NFPA 72 Fire Alarm Applications 8.0 NFPA 72 Fire Alarm Applications 8.1 Household Burglary and Commercial Burglary Four hours of standby battery capacity are required. 8.2 Bank Safe and Vault Because of changing regulations, verify the necessary time with your local authority having jurisdiction (AHJ). UL 365 requires 72 h of standby battery capacity. Limit the auiliary power current for all devices, including keypads, to 300 ma or less to meet this requirement. Table 6: Standby Battery Requirements Type Required Capacity Calculations Household Burglary and Commercial 4 h Burglary Bank Safe and Vault 72 h (UL 365). Auiliary power current for all devices, including keypads, must be limited to 300 ma or less to meet this requirement. Central Station or Local Fire Alarm 24 h + 5 min of alarm operation. Refer to Table 8 on page 28. Remote Station or Auiliary Fire Alarm 60 h + 5 min of alarm operation. Refer to Table 9 on page 28. Household Fire Warning Equipment 24 h + 4 min of alarm operation. Refer to Table on page 29. 8.3 Standby Battery Calculation Because of changing regulations, verify the necessary time with your local authority having jurisdiction (AHJ). Refer to Table 5 on page 25 for totals B and C used in the formulas below. When connecting two batteries, use either the D122 Dual Battery Wiring Harness or the D8132 Battery Charger Module. Table 7: General Ampere-Hour (Ah) Calculation Formula Total B 1 Hours Total C 1 Alarm Operation 2 Contingency Total Ah 3 ( 24 ) + ( 0.083) + % = 1 Refer to Table 5 on page 25. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not eceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah 26 Bosch Security Systems, Inc. /08 F01U003639-03

D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0. 8.4 Central Station or Local Systems NFPA 72 Fire Alarm Applications Central Station or Local Systems require 24 h of standby plus 5 min of alarm operation at the end of the 24- hour period. A single battery is sometimes adequate for central station systems, but two batteries must be installed to meet the basic standby requirements for a local system installation. Use the battery ampere-hour (Ah) calculations to confirm compliance. The formula in Table 8 includes the calculation for 5 min of alarm operation at the end of the 24-hour period, as well as a % contingency factor that allows for depletion of battery capacity with age. Because of changing regulations, verify the necessary time with your local AHJ (authority having jurisdiction). Table 8: Central Stations or Local Systems Ah Calculation Formula Total B 1 Hours Total C 1 Alarm Operation 2 Contingency Total Ah 3 ( 24) + ( 0.083) + % = 1 Refer to Table 5 on page 25. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not eceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah 8.5 Remote Station or Auiliary Systems Remote Station or Auiliary Systems require 60 h of standby plus 5 min of alarm operation at the end of the 60-hour period. A D8132 Battery Charger Module with additional batteries installed in a separate D89 or D88A Enclosure might be required in the system to meet the basic standby requirements for a remote station or auiliary system installation. Use battery Ah calculations to confirm compliance. The formula in Table 9 includes the calculation for 5 min of alarm operation at the end of the 60-hour period, as well as a % contingency factor that allows for depletion of battery capacity with age. Because of changing regulations, verify the necessary time with your local AHJ (authority having jurisdiction). Table 9: Remote Station or Auiliary Systems Ah Calculation Formula Total B 1 Hours Total C 1 Alarm Operation 2 Contingency Total Ah 3 ( 60) + ( 0.083) + % = 1 Refer to Table 5 on page 25. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not eceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah Bosch Security Systems, Inc. /08 F01U003639-03 27

D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0 NFPA 72 Fire Alarm Applications 8.6 Household Fire Warning Equipment The Household Fire Warning Equipment Standard requires 24 h of standby current plus 4 min of alarm operation at the end of the 24-hour period. Use battery Ah calculations to confirm compliance. The formula in Table includes the calculation for 4 min of alarm operation at the end of the 24-hour period, and a % contingency factor that allows for depletion of battery capacity with age. Because of changing regulations, verify the necessary time with your local AHJ (authority having jurisdiction). Table : Household Fire Ah Calculation Formula Total B 1 Hours Total C 1 Alarm Operation 2 Contingency Total Ah 3 ( 24) + ( 0.067) + % = 1 Refer to Table 5 on page 25. 2 Value = Minutes of alarm operation 60 3 Total Ah requirements must not eceed the Ah capacity of batteries: One D126 Battery = 7 Ah Two D126 Batteries = 14 Ah One D1218 Battery = 17.2 or 18 Ah Two D1218 Batteries = 34.4 or 36 Ah 28 Bosch Security Systems, Inc. /08 F01U003639-03

. D9412GV2/D7412GV2 Approved Applications Compliance Guide Notes Notes Bosch Security Systems, Inc. /08 F01U003639-03 29