The System 5000 Operating Manual

Similar documents
The RPT-485W/RPT-485WF

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

Supplement to the AM2020/AFP1010 Voice Alarm Multiplex Manual Number 15889, Revision F1, dated 12/11/97

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Annunciator Modules. for Fire Lite Fire Alarm Control Panels. Document # /30/95 Revision:

EXTINGUISHING AGENT RELEASE MODULE

The MC-1. Master Clock System

CHG-120 Battery Charger Instruction Manual. Document /06/2002 Rev: B1 PN 50641: B1 ECN

FCPS-24/FCPS-24E. Field Charger/Power Supply. Installation, Operation and Application Manual.

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

CMP-2401B/CMP-2402B. Fire Alarm Control Panel. Installation, Maintenance and Operating Instruction Manual

Conventional Fire Alarm Control Panel

PN:51264:A2 ECN Remote Fire Annunciator FDU-80. Document /14/00 Rev: A.

CFP-2401B/CFP-2402B. Fire Alarm Control Panel. Installation, Maintenance and Operating Instruction Manual.

PN: 51604:A ECN Voice Evacuation Control Panel FIRE COMMAND 25/50X & FIRE COMMAND 25/50XE. Document # /17/02 Rev.

The ACM-8R Annunciator Control Module

MS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual

AFP-300/AFP-400 Analog Fire Panel

HP101U Conventional Fire Alarm Control Panel Installation And Operation Manual

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

ECC-50DA/E ECC-125DA/E ECC-50BDA/E. Distributed Audio Amplifiers. Installation Manual C. Document LS FL-E 1/30/2014 Rev:

SILENT KNIGHT. Model SK-2/E & SK-4/E. Installation and Operations Manual. Fire Alarm Control Panel. Part Number Rev. A ECN /08/05

PN: 51883:D ECN Field Charger/Power Supply FCPS-24FS6 FCPS-24FS8. Document # /14/05 Revision: D

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Lamp Driver Module LDM-32F

PS-Tools. User s Guide for the 50 Pt Addr Panel

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Panic. Part Number SYSTEMS, Inc.

Digital Alarm Communicator/Transmitter. Document # /07/00 Rev. P/N 50921:C ECN

Digital Alarm Communicator/Transmitter 411UD. Document # /07/00 Rev. P/N 50759:C ECN

MS-5012 Control Communicator

The ADT SLC Signaling Line Circuit Manual

4100U City and Relay Cards Installation Instructions

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

MR-2602 Two Zone Fire Alarm Control Panel

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

ONYXWorks. ONYXWorks NOTIFY IP. Installation & Operation Manual. Document /23/11 Rev: A3 P/N: 53620:A3 ECN:

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

RAX-LCD-LITE. Remote Annunciator. Installation and Operation Manual

Field Charger/Power Supply FCPS-24S6 FCPS-24S8. Document # /06/03 Revision: C1 PN: 51977:C1 ECN

Fire Alarm Control Panels MS-2 & MS-4 MS-2E & MS-4E. Instruction Manual. Document /6/2014 Rev: G3 P/N 51512:G3 ECN

KP600F/L LED/LCD KEYPADS. Owner's Manual. Use with AV6500 & SP850 Control panels

ANNUNCIATOR FIXED MODULE

INSTRUCTION MANUAL PC255O

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

RE 2554 RE Automatic Fire Alarm Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Beacon 800 Gas Monitor Operator s Manual

Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

PN 50257:E ECN NOTI FIRE NET. Manual. Document 50257:E 7/5/01 Rev: E. Technical Manuals Online! -

INSTRUCTION MANUAL PC255O

SC-6 Six Supervised Control Module

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

Automatic Phone-Out Home Monitoring Systems

Network Display Unit Installation Instructions

Using your LED Plus keypad

NX-148 LCD CODE PAD TABLE OF CONTENTS

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

RAM-3500-LCD. Remote Annunciator. Installation and Operation Manual

Installation, Operating and Maintenance Manual

Long Range Radio Alarm Transmitter

Alarm Tone Generator Model AG17

Model SK Installation and Operations Manual. Fire Control / Communicator. Document Rev: P P/N :P ECN:

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

AFP-100 Intelligent Fire Panel

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

NFPA 72 Code Changes vs 2013

Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head)

636 and 646 Keypads. User s Manual

Model SS2000SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head)

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Quick Reference Guide

The MS-4424 FIRE ALARM CONTROL PANEL

Fire Command Keypad. XR5 User s Guide

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

Functional Performance Test

Long Range Radio Alarm Transmitter

TABLE OF CONTENTS TABLE OF CONTENTS 1

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

December Scorpio. Fire Control Panel. Installation, Operation & Maintenance Manual. P/N UL Listing File No. S2422.

TECHNICAL DATA OBSOLETE

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

MR-2316-AT/Z Remote Annunciator

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Operation & Maintenance Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Design Manual Installation Operation Maintenance

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SFC-200 SERIES LED FIRE ALARM PANEL

Model SS2000C31 SmartSystem Load Management System

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Transcription:

12 Clintonville Road, Northford, CT 06472-1610 203-484-7161 FAX: 203-484-7118 The System 5000 Operating Manual C Document 15581 04/17/97 Rev: P/N 15581:C ECN 97-148

Installation Precautions - Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is energized. Do not attempt to install, service, or operate this unit until this manual is read and understood. CAUTION - System Reacceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 72-1993 Chapter 7 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. This system meets NFPA requirements for operation at 0-49 O C/32-120 O F and at a relative humidity of 85% RH (non-condensing) at 30 O C/86 O F. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a nominal room temperature of 15-27 O C/60-80 O F. Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a 10% I.R. drop from the specified device voltage. Like all solid state electronic devices, this system may operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely immune from lightning transients and interferences, proper grounding will reduce susceptibility. Overhead or outside aerial wiring is not recommended, due to an increased susceptibility to nearby lightning strikes. Consult with the Technical Services Department if any problems are anticipated or encountered. Disconnect AC power and batteries prior to removing or inserting circuit boards. Failure to do so can damage circuits. Remove all electronic assemblies prior to any drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, and printed circuit board location. Do not tighten screw terminals more than 9 in-lbs. Over tightening may damage threads, resulting in reduced terminal contact pressure and difficulty with screw terminal removal. This system contains static-sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. Use static suppressive packaging to protect electronic assemblies removed from the unit. Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment. FACP operation and reliability depend upon proper installation. Fire Alarm System Limitations While installing a fire alarm system may make lower insurance rates possible, it is not a substitute for fire insurance! An automatic fire alarm system - typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control with remote notification capability can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. Any fire alarm system may fail for a variety of reasons: Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second floor detector, for example, may not sense a first floor or basement fire. Furthermore, all types of smoke detectors - both ionization and photoelectric types, have sensing limitations. No type of smoke detector can sense every kind of fire caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signaling, and/or power. If detectors are not so located, a developing fire may damage the alarm system, crippling its ability to report a fire. Audible warning devices such as bells may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. A fire alarm system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time. Rate-of-Rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Equipment used in the system may not be technically compatible with the control. It is essential to use only equipment listed for service with your control panel. Telephone lines needed to transmit alarm signals from a premise to a central monitoring station may be out of service or temporarily disabled. The most common cause of fire alarm malfunctions, however, is inadequate maintenance. All devices and system wiring should be tested and maintained by professional fire alarm installers following written procedures supplied with each device. System inspection and testing should be scheduled monthly or as required by National and/or local fire codes. Adequate written records of all inspections should be kept. FCC Warning WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which is designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his own expense. Canadian Requirements This digital apparatus does not exceed the Class A limits for radiation noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. Technical Publishing Document PRECAULG.P65 12/31/96

Table of Contents 1. The System 5000 Automatic Fire Alarm System 1.1 Central Processor Unit Module (CPU-5000)... 4 1.2 Initiating Zone Module (IZM-8)... 4 1.3 Indicating Circuit Module (ICM-4)... 4 1.4 Control Relay Module (CRM-4)... 4 1.5 Audio Message Generator (AMG-1)... 4 1.6 Audio Amplifier (AA-30/AA-100/AA-120)... 5 1.7 Voice Control Module (VCM-4) and Voice Control Expander (VCE-4)... 5 1.8 Dual Channel Module (DCM-4)... 5 1.9 Fire Fighter's Telephone (FFT-7)... 5 1.10 Basic Operation... 5 1.11 Typical System 5000 Installation... 6 2. Operating Instructions 2.1 General System Operating Instructions... 7 2.2 CPU-5000 Module, Controls and Indicators... 8 2.3 IZM-8 Initiating Zone Module, Controls and Indicators... 9 2.4 ICM-4 Indicating Circuit Module, Controls and Indicators... 10 2.5 CRM-4 Control Relay Module, Controls and Indicators... 10 2.6 VCM-4 Voice Control Module, Controls and Indicators... 11 2.7 DCM-4 Dual Channel Module, Controls and Indicators... 11 2.8 AMG-1 Audio Message Generator, Controls and Indicators... 12 2.9 AA-30 Audio Amplifier Status Indicators... 13 2.10 AA-100/AA-120 Audio Amplifier Status Indicators... 14 2.11 FFT-7 Fire Fighter's Telephone, Controls and Indicators... 15 2.12 Optional MPS-24A Main Power Supply, Status Indicators... 16 2.13 AVPS-24 Audio-Visual Power Supply, Status Indicators... 16 3. Periodic Testing and Maintenance 3.1 Periodic Testing and Servicing... 17 3.2 Operational Checks... 17 Table of Figures Figure 1.1 A Typical System 5000... 6 Figure 2.1 The CPU-5000 Central Processing Unit... 8 Figure 2.2 The IZM-8 Initiating Zone Module... 9 Figure 2.3 The ICM-4 Indicating Circuit Module... 10 Figure 2.4 The CRM-4 Control Relay Module... 10 Figure 2.5 The VCM-4 Voice Control Module, Controls and Indicators... 11 Figure 2.6 The DCM-4 Dual Channel Module, Controls and Indicators... 11 Figure 2.7 The AMG-1 Audio Message Generator, Controls and Indicators... 12 Figure 2.8 The AA-30 Audio Amplifier... 13 Figure 2.9 The AA-30 Audio Amplifier, Status Indicators... 13 Figure 2.10 The AA-100/AA-120 Audio Amplifier... 14 Figure 2.11 The AA-100/AA-120 Audio Amplifier, Status Indicators... 14 Figure 2.12 The FFT-7 Fire Fighter's Telephone, Controls and Indicators... 15 Figure 2.13 Optional MPS-24A Main Power Supply Status Indicators... 16 Figure 2.14 The AVPS-24 Audio-Visual Power Supply... 16 System 5000 Operation 15581:C 04/17/97 3

Section 1 The System 5000 Automatic Fire Alarm System 1.1 Central Processor Unit Module (CPU-5000) The CPU-5000 is a controller-based module that communicates with all system modules and directs all system operation. Key components of the CPU-5000 include: two supervised indicating circuits that usually control notification appliances, such as bells, chimes, horns, and strobes an alarm relay that can be connected to control external devices including elevators, doors, and air handling equipment a Remote Signaling-Municipal Tie output that can connect to a municipal fire department, central station, or a remote monitoring station CPU-5000 controls and indicators (described in Section 2.2) 1.2 Initiating Zone Module (IZM-8) Each Initiating Zone Module (IZM-8) can monitor up to eight initiating zones (groups of initiating devices such as smoke detectors, pull stations, heat detectors, etc.) for alarm activation. The IZM-8 also checks the integrity of wiring connections to the CPU and the status of initiating devices. The IZM-8 module transmits the status of wiring and the initiating zones to the CPU module. When directed by the CPU-5000, the IZM-8 lights LED indicators to display alarm and trouble (such as broken wire, inactive circuit, etc.) conditions. The IZM-8 module includes an alarm indicator (red LED), a trouble indicator (yellow LED), and a control switch for each zone (described in Section 2.3). 1.3 Indicating Circuit Module (ICM-4) Each Indicating Circuit Module (ICM-4) controls and monitors up to four Notification Appliance Circuits (expandable to eight with the ICE-4) with notification appliances such as bells, chimes, horns, or strobes. The ICM-4 module transmits the status of the NACs and wiring to the CPU. When directed by the CPU-5000, the ICM-4 lights LEDs to display activation and trouble (broken wire, inactive circuit, etc.) conditions. Notification Appliance Circuits activate automatically during an alarm condition according to programmed instructions stored in CPU memory. The NACs can also be activated manually. The ICM-4 module includes an activation indicator (green LED), a trouble indicator (yellow LED), and a control switch for each circuit (described in Section 2.4). 1.4 Control Relay Module (CRM-4) Each CRM-4 can control up to four relays (expandable to eight with the CRE-4), which control external devices including elevators, doors, and air handling equipment. Control relays activate automatically during an alarm according to programmed instructions stored in CPU memory. A control relay can be manually activated using a CRM-4 control switch. A CRM-4 module includes an activation indicator (green LED), a trouble indicator (yellow LED), and a control switch for each relay (described in Section 2.5). 4 System 5000 Operation 15581:C 04/17/97

1.5 Audio Message Generator (AMG-1) The AMG-1, which is the heart of a System 5000 Voice Alarm System, provides digitally-recorded messages, a variety of tones, and paging capability. Digitally-recorded messages and/or tones activate automatically during an alarm according to programmed instructions stored in CPU memory. Live voice paging can override recorded messages and tones. 1.6 Audio Amplifier (AA-30/AA-100/AA-120) An AA-30/AA-100/AA-120 amplifies AMG-1 messages and tones before they are switched to speaker circuits. Refer to Sections 2.8 and 2.9 for LED and switch function descriptions. 1.7 Voice Control Module (VCM-4) and Voice Control Expander (VCE-4) Each VCM-4 can control and monitor up to four speaker or telephone circuits (expandable to eight with the VCE-4). These modules transmit the status of each speaker or telephone circuit and the wiring to the CPU. VCM-4/VCE-4 modules light LEDs to display activation and trouble (broken wire, inactive circuit, etc.) conditions, as directed by the CPU. Speaker or telephone circuits activate automatically during an alarm according to programmed instructions stored in CPU memory. These circuits can be activated manually. The VCM-4 and VCE-4 modules include an activation indicator (green LED), a trouble indicator (yellow LED), and a control switch for each circuit. LED and switch functions are described in Section 2.6. 1.8 Dual Channel Module (DCM-4) The DCM-4 gives the System 5000 the capability of delivering different messages, to different areas, at the same time. For example, the System 5000 can deliver an evacuation message to the fire area and a warning message to the non-fire areas at the same time. Channel selection occurs automatically during an alarm condition according to programmed instructions stored in CPU memory. Channel selection can also be made manually. The DCM-4 includes a channel indicator (green LED), and a control switch for each circuit. LED and switch functions are described in Section 2.7. 1.9 Fire Fighter's Telephone (FFT-7) The FFT-7 provides the System 5000 with fire fighter's telephone capabilities. Refer to Section 2.11 for LED and switch function descriptions. 1.10 Basic Operation Activation of a compatible detector or a normally open fire alarm initiating device will cause the following: 1) activation of alarm, indicating, control, and signaling outputs, as programmed 2) flash the red System Alarm LED and corresponding initiating zone alarm LEDs 3) sound a steady audible tone. Alarm indicating, control, and signaling outputs remain active until the alarm is reset or silenced (refer to Section 2) Alarm LEDs flash and a continuous audible tone sounds until the alarm is silenced or acknowledged. Silencing or acknowledging an alarm turns the audible tone off and switches LED operation from flashing to steady. Subsequent alarms will resound the audible tone and flash their indicating LEDs. Alarm signals latch until the control is reset. System 5000 Operation 15581:C 04/17/97 5

1.11 Typical System 5000 Installation The System 5000 requires a CPU-5000 module (top left position), and one IZM-8 module. Additional modules are optional. Figure 1.1 illustrates a typical System 5000 installation in a four-row cabinet (CAB D) with optional modules: CPU-5000 Central Processing Unit IZM-8 Initiating Zone Module CRM-4 Control Relay Module* AMG-1 Audio Message Generator* FFT-7 Fire Fighter's Telephone* ICM-4 Indicating Circuit Module* VCM-4 Voice Control Module* (configured for speaker circuits) VCM-4 Voice Control Module* (configured for telephone circuits) AA-30, AA-100 or AA-120 Audio Amplifier* (under blank dress plate) * Optional module. Figure 1.1 Typical System 5000 Installation Note: The System 5000 is available in four cabinet sizes: CAB A (one row) CAB B (two rows) CAB C (three rows) CAB D (four rows). 6 System 5000 Operation 15581:C 04/17/97

Section 2 2.1 General System Operating Instructions Operating Instructions Normal Standby Operation - green AC Power LED on, all red alarm LEDs off, and all yellow trouble LEDs off. Alarm condition - When an alarm occurs, the control panel does the following: lights the red System Alarm LED and associated initiating zone alarm LEDs. Alarm LEDs flash until the alarm is acknowledged or silenced. sounds a steady audible tone until the alarm is acknowledged or silenced (see table below). activates alarm indicating, control, and signaling output circuits as programmed. Trouble condition - A trouble signal under normal operation indicates a condition that requires immediate correction. Carefully note which yellow LEDs light; then contact your local service representative. When a trouble occurs, the control panel does the following: lights the yellow System Trouble LED and the yellow LED on the output circuits with a trouble. Trouble LEDs flash until someone acknowledges or silences the alarm. sounds a pulsed audible tone until the trouble is acknowledged or silenced. A trouble LED lights until the trouble is corrected. Troubles are self-resetting and clear as soon as the trouble is corrected. If the Reminder feature is enabled, the trouble sounder pulses every 2 minutes for an acknowledged trouble. To silence a trouble, follow the instructions in the table below. Operating the control panel - The following table contains instructions for operating the control panel: T o... Do this... Comments Acknowledge an alarm or trouble Silence an alarm Warning: Do not silence an alarm until making sure that building evacuation is not required. Reset an alarm Disable or enable an output circuit* Warning: Disabling a circuit will reduce or eliminate fire protection. Manually activate an ouput circuit* Press Acknowledge Silence Tone to turn the audible tone off and switch operation of active LED(s) from flashing to steady. Press Signal Silence to silence indicating devices. Locate and correct the alarm condition; then press System R eset to reset the control panel. Press and hold D isable/enable; then press a control switch on a module to toggle the selected circuit to be disabled or enabled. Press the module On/Off switch and the circuit LED (red or green) lights. New alarms and/or troubles will resound the audible tone and flash the corresponding LEDs. 1) New alarms can reactivate alarm outputs. 2) Alarm silencing may be totally or partially disabled or delayed in some systems. 3) If the Reminder feature is enabled, the sounder pulses every 15 seconds for an acknowledged alarm. System will reset, but if any device is still in alarm or reactivates, the system will go back into alarm. 1) Only use this feature to temporarily bypass a malfunction or to remove a circuit while servicing the system. 2) To disable a circuit: press and hold D isable/enable; then press the control switch of the circuit. The yellow LED for the circuit lights to indicate a disabled circuit. 1) Subsequent alarms can activate a deactivated output circuit. 2) Manual activation of an output circuit can be disabled from the control panel. * Output circuits include: indicating, speaker and telephone circuits, and control relay circuits System 5000 Operation 15581:C 04/17/97 7

2.2 CPU-5000 Module, Controls and Indicators (See Figure 2.1) AC Power - A green LED that lights to indicate normal AC power and extinguishes when the AC line voltage is below normal. System Alarm - A red LED (normally off) that lights to indicate an alarm condition. Alarms are indicated by flashing LEDs and a continuous audible tone until silenced or acknowledged. Silencing or acknowledging an alarm turns the audible tone off and switches LED operation from flashing to steady. Subsequent alarms will resound the audible tone and flash their indicating LEDs. Alarm signals latch until the control panel is reset. Trouble Indicators - Trouble indicators (yellow LEDs) are normally off and light to indicate trouble conditions and/or disabled outputs. Troubles are indicated by flashing LEDs and a pulsed audible tone until the trouble is acknowledged or corrected. Acknowledging a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble will resound the audible tone and flash the LEDs. All trouble signals are normally selfresetting and clear as soon as the trouble condition is corrected. System Trouble - Indicates a trouble condition in the system. Module Failure - Indicates the failure of a system module. AC/BATT/GND Fault - Indicates 1) a power supply is not working correctly, 2) AC line voltage is below normal, 3) improper battery voltage, or 4) a ground fault. Additional information displays on internal LEDs located on power supply assemblies. Refer to Sections 2.6 and 2.7. Signal Silenced - Indicates that an output circuit is silenced. The LED remains on until the System Reset switch is pressed. Disabled Circuits - Indicates that part of the system has been manually shut down. Local Sounder (not shown) - Sounds a pulse tone for a trouble, a disabled output, and a supervisory; sounds a continuous tone for an alarm. Figure 2.1 The CPU-5000 Central Processor Module Acknowledge/Silence Tone - Pressing Acknowledge/Silence Tone switch turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble or alarm resounds the audible tone and flashes the indicating LEDs. While pressing and holding this switch, trouble LEDs do not indicate off-normal conditions. Acknowledge/Silence Tone also automatically acknowledges all annunciators in the system. Signal Silence - Returns all silenceable outputs, which were automatically activated by the alarm condition, to their non-alarm state. A subsequent alarm can reactivate alarm outputs. 8 System 5000 Operation 15581:C 04/17/97

CPU-5000 Module, Controls and Indicators (See Figure 2.1) System Reset - Resets the system, causing all outputs to return to normal. If an alarm or trouble still exists, the system will return to an alarm or trouble condition. Pressing and holding this switch sequentially lights all LEDs (lamp test). Disable/Enable - Use this switch with the module switches to enable and disable control, initiating, and signaling circuits. To illuminate the LEDs of disabled circuits, press and hold the Disable/Enable switch. Green LEDs (output circuits) - Normally off, LEDs light to indicate an activated output. A flashing LED indicates automatic activation until acknowledged. A steady LED indicates manual activation. Yellow LEDs (output circuits) - Normally off, LEDs light to indicate trouble conditions or disabled outputs. A flashing LED and a pulsed audible tone indicates a new trouble until the trouble is silenced or corrected. Silencing a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble from a different circuit resounds the audible tone and flashes the LED. Trouble signals are normally selfresetting and clear as soon as the trouble conditions are corrected. On/Off switches (output circuits) - Use to activate and deactivate outputs. Notes: 1) The switch function may be disabled for selected outputs. 2) Subsequent alarms will reactivate deactivated outputs. 3) Pressing the On/Off switch while pressing and holding the Disable/Enable switch alternately enables and disables the output. 2.3 IZM-8 Initiating Zone Module, Controls and Indicators (See Figure 2.2) Red LEDs - Normally off, LEDs light to indicate alarm conditions. New alarms are indicated by a flashing LED and a steady audible tone until the alarm is acknowledged or silenced. Silencing an alarm turns the audible tone off and switches LED operation from flashing to steady. Yellow LEDs - Normally off, LEDs light to indicate an initiating zone trouble or disabled zone. New troubles are indicated by a flashing LED and a pulsed audible tone until the troubles are silenced or corrected. Silencing a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble from a different initiating zone resounds the audible tone and flashes the LED. Trouble signals are normally self resetting and clear as soon as the trouble conditions are corrected. While pressing and holding the Acknowledge switch, trouble LEDs do not indicate disabled zones only open initiating zones. While pressing and holding the Disable/Enable switch, yellow LEDs only indicate disabled initiating zones. Display Program switches - Light the red zone alarm LED and the green LEDs on all outputs controlled by the initiating zone. Pressing the display program switch, while pressing and holding the Disable/Enable switch, alternately enables and disables the initiating zone. Figure 2.2 The IZM-8 Initiating Zone Module System 5000 Operation 15581:C 04/17/97 9

2.4 ICM-4 Indicating Circuit Module, Controls and Indicators (See Figure 2.3) Green LEDs - Normally off, LEDs light to indicate an activated Notification Appliance Circuit. Yellow LEDs - Normally off, LEDs light to indicate a Notification Appliance Circuit trouble or a disabled circuit. New troubles are indicated by a flashing LED and a pulsed audible tone until the troubles are silenced or corrected. Silencing a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble from a different circuit resounds the audible tone and flashes the corresponding trouble LED. Trouble signals are normally self-resetting and clear as soon as the trouble conditions are corrected. While pressing and holding the Disable/Enable switch, yellow LEDs only indicate disabled conditions. On/Off switches Use to activate and deactivate Notification Appliance Circuits. Notes: 1) The switch function may be disabled on selected indicating circuits. 2) Subsequent alarms will reactivate deactivated circuits. Pressing the On/Off switch while pressing and holding the Disable/Enable switch alternately enables and disables the corresponding indicating circuit. Figure 2.3 The ICM-4 Indicating Circuit Module 2.5 CRM-4 Control Relay Module, Controls and Indicators (See Figure 2.4) Green LEDs - Normally off, LEDs light to indicate that the control relay is activated. Yellow LEDs - Normally off, LEDs light to indicate a disabled control relay output. On/Off switches Use to activate and deactivate control relays. Notes: 1) The switch function may be disabled (from the CPU) for selected relays. 2) Subsequent alarms will reactivate deactivated outputs. Pressing the On/Off switch while pressing and holding the Disable/ Enable switch alternately enables and disables a selected control relay. Figure 2.4 The CRM-4 Control Relay Module 10 System 5000 Operation 15581:C 04/17/97

2.6 VCM-4 Voice Control Module, Controls and Indicators (See Figure 2.5) Green LEDs - Normally off, LEDs light to indicate an activated speaker circuit. Yellow LEDs - Normally off, LEDs light to indicate a speaker or telephone circuit trouble or a disabled circuit. New troubles are indicated by a flashing LED and a pulsed audible tone until the troubles are silenced or corrected. Silencing a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble, from a different circuit, resounds the audible tone and flashes the associated trouble LED. Trouble signals are normally self resetting and clear as soon as the trouble conditions are corrected. While pressing and holding the Disable/Enable switch, yellow LEDs only indicate disabled conditions. On/Off switches Use to activate and deactivate speaker circuits. Notes: 1) The switch function may be disabled (from the CPU) on selected speaker circuits. 2) Subsequent alarms will reactivate deactivated circuits. 3) Pressing the On/Off switch while pressing and holding the Disable/ Enable switch alternately enables and disables the selected circuit. Figure 2.5 The VCM-4 Voice Control Module 2.7 DCM-4 Dual Channel Module, Controls and Indicators (See Figure 2.6) Green LEDs (left side) - Normally off, LEDs light to indicate selection of channel A (evacuate channel). Yellow LEDs (left side) - Normally off. On/Off switches (left side) - Used to select channel A or channel B. Green LEDs (right side) - Normally off, LEDs light to indicate an activated speaker circuit. Yellow LEDs (right side) - Normally off, LEDs light to indicate a speaker circuit trouble or a disabled speaker circuit. New troubles are indicated by a flashing LED and a pulsed audible tone until the troubles are silenced or corrected. Silencing a trouble turns the audible tone off and switches LED operation from flashing to steady. A subsequent trouble, from a different circuit, will resound the audible tone and flash the associated trouble LED. Trouble signals are normally self resetting and clear as soon as the trouble conditions are corrected. While pressing and holding the Disable/Enable switch, yellow LEDs only indicate disabled conditions. On/Off switches (right side) Use to activate and deactivate speaker circuits. Notes: 1) The switch function may be disabled on selected speaker circuits. 2) Subsequent alarms will reactivate deactivated circuits. Pressing the On/ Off switch while pressing and holding the Disable/Enable switch alternately enables and disables the selected circuit. Figure 2.6 The DCM-4 Dual Channel Module System 5000 Operation 15581:C 04/17/97 11

2.8 AMG-1 Audio Message Generator, Control and Indicators (See Figure 2.7) LED Status Indicators Audio Level - A green LED, which is normally illuminated in normal standby and alarm mode, remains on when the audio level is correct. When paging, talk loud enough to cause the LED to light. If the Audio Level LED remains off for 30 seconds, the CPU activates a system trouble. All Call - A green LED (normally off) lights when pressing the All Call switch. On Line - A green LED indicator normally flashes on and off to indicate communication between the System 5000 and the AMG-1. Trouble - A yellow LED (normally off) lights to indicate a trouble in the audio subsystem (AMG-1, AA-30/AA-100/AA-120, FFT-7). The CPU-5000 also indicates an audio system trouble by flashing Module Trouble and System Trouble LEDs and Figure 2.7 sounding a pulsed audible tone until troubles are The AMG-1 Audio silenced or corrected. Silencing a trouble turns the Message Generator audible tone off and switches CPU-5000 LED operation from flashing to steady. Trouble signals are normally self-resetting and clear as soon as trouble conditions are corrected. Controls All Call switch - If connected and programmed, pressing this switch activates all speaker circuits or a specific group of speakers, according to programmed instructions in CPU memory. Releasing the All Call switch deactivates the speaker circuits if no alarms exist. If an alarm exists, speaker circuits remain active until the speakers are manually turned off or the system is reset. Local Speaker Volume - Use this control to adjust the volume of the speaker located on the AMG-1 only. Microphone - Use to page through the selected speakers. Activate the speakers by pressing the All Call switch or setting the control switches on individual speaker circuits (VCM-4/VCE-4 modules). Press the microphone switch and speak into the microphone, speaking loudly enough to light the green Audio Level LED. 12 System 5000 Operation 15581:C 04/17/97

2.9 AA-30 Audio Amplifier, Control and Indicators (See Figures 2.8 & 2.9) 1) Use the status indicators (located under the blank dress panel) on an audio amplifier for troubleshooting the system. 2) The CPU indicates a Speaker Trouble, Amplifier Trouble, Battery Trouble, or Brownout Trouble in an audio amplifier by flashing CPU Power Failure and System Trouble LEDs and sounding a pulsed audible tone until silencing or correcting the trouble. Silencing a trouble turns the audible tone off and switches CPU- 5000 LED operation from flashing to steady. Trouble signals are normally self-resetting and clear as soon as the trouble conditions are corrected. 3) The Incorrect Level LED only indicates that the audio level needs adjustment not a system trouble. Figure 2.8 The AA-30 Audio Amplifier Speaker Trouble LED An open circuit condition in the 4- wire speaker loop. Amplifier Trouble LED Loss of the audio input signal, or trouble in the audio in or audio out circuitry. Battery Trouble LED sufficient voltage level. The secondary (DC) power source is below a Brownout LED The primary (AC) power source is below a sufficient level. Note: During a complete loss of AC power, no LEDs will light on the AA-30. Incorrect Level LED During normal (non-alarm) conditions, this LED indicates that the AA- 30 is out of adjustment. When this LED is on and the Normal Level LED is off, the audio level is adjusted too low. When both this LED and the Normal Level LED are on, the audio level is adjusted too high. Normal Level LED During normal (non-alarm) conditions, when this green LED is on and the Incorrect Level LED is off, the AA-30 is adjusted properly and operating correctly. Note: During complete loss of primary (AC) power, when the AA-30 is operating on secondary (battery) power, no LEDs will light on the AA-30 (to conserve secondary power). Figure 2.9 AA-30 Audio Amplifier Status LEDs System 5000 Operation 15581:C 04/17/97 13

2.10 AA-100/AA-120 Audio Amplifier, Control and Indicators (See Figures 2.10 & 2.11) Audio Gain Switch Description This multi-position rotary switch lets the installer adjust the gain of the audio output signal to compensate for audio line losses. After correct adjustment, the AA-120 produces its maximum rated output power of 25 V rms and the AA-100 produces 70.7 V RMS. Adjusting the Audio Gain Level After installing amplifiers and circuitry and setting the amplifier for normal standby, use a small, slotted screwdriver to turn the rotary switch until the Normal Level LED is lit and the Incorrect Level LED is off. At this point, the audio gain is properly adjusted. Note: To calibrate an audio amplifier, a 470 ohm resistor must be installed at the end of the low level audio loop. Audio Gain Figure 2.10 The AA-100/AA-120 Audio Amplifier Normal Level LED During normal (nonalarm) conditions, when this green LED is on and the Incorrect Level LED is off, the audio amplifier is adjusted properly and operating correctly. Note: During complete loss of AC power no LEDs will light on the AA-100/AA-120 while the AA-100/AA-120 operates on battery power (to conserve battery power). Battery Trouble LED sufficient level. The battery voltage is below a Brownout LED AC power source is below a sufficient level. During a complete loss of AC, no LEDs will light on the AA-100/AA-120. Speaker Trouble LED An open circuit condition in the 4-wire high-level output. Incorrect Level LED During normal Input Trouble LED Loss of the low-level audio input (non-alarm) conditions, indicates that the signal, or amplifier failure. audio amplifier needs adjustment. When this LED is on and the Normal Level LED Amplifier Trouble LED Loss of the low-level audio is off, the audio level is adjusted too low. input signal, or amplifier failure. When both this LED and the Normal Level LED are on, the audio level is adjusted too high. Note: The amplifier will not indicate a trouble condition until 40 seconds after these faults occur. Figure 2-11: AA-100/AA-120 Audio Amplifier Status LEDs Selecting the AA-100/AA-120 Default Backup Tone Use SW1, located in the lower right-hand corner of the AA-100/AA-120 circuit board, to select Hi/Lo or Slow Whoop as the default backup tone. The backup tone starts automatically if a low-level audio input to the AA-100/AA- 120 is lost. SW1 Backup Tone switch HI/LO SLOW WHOOP 14 System 5000 Operation 15581:C 04/17/97

2.11 FFT-7 Fire Fighter's Telephone, Control and Indicators (See Figure 2.12) LED Status Indicators Page Mode - A green LED lights while pressing the Page Mode switch. On Line - A green LED (normally on) indicates that the System 5000 is powering the Fire Fighter's Telephone system. Phone Trouble - A yellow LED (normally off) lights to indicates a trouble in the Fire Fighter's Master Telephone (FFT-7) circuit. Line Trouble - A yellow LED (normally off) lights to indicate a trouble in the wiring between the FFT-7 and corresponding VCM-4 modules. Note: The CPU also shows a Phone Trouble or Line Trouble on the CPU-5000 by flashing Module Trouble and System Trouble LEDs and pulsing an audible tone until silencing or correcting the trouble. Silencing a trouble turns the audible tone off and switches CPU-5000 LED operation from flashing to steady. Trouble signals are normally self resetting and clear as soon as the trouble conditions are corrected. Figure 2.12 The FFT-7 Fire Fighter's Telephone Controls Page switch - Press to page through an FFT-7. To enable paging from a remote FFT-7, follow these instructions: 1) Press the Page switch 2) Select the speaker circuits for paging by setting the control switches on VCM-4 speaker or telephone circuits or press the All Call switch (see instructions above) 3) Tell the person paging to speak into the FFT-7 handset. Note that paging should be loud enough to light the green Audio Level LED on the AMG-1 System 5000 Operation 15581:C 04/17/97 15

2.12 Optional MPS-24A Main Power Supply, Status Indicators (See Figure 2.13) Trouble Indicators The MPS-24A includes four trouble indicators (yellow LEDs, normally off) that light to show trouble conditions. Trouble signals are normally self resetting and clear as soon as the trouble condition is corrected. L ED Indicates... A C Power Fail (LED 2) 1) loss of AC line voltage; 2) low AC line voltage; or 3) open circuit breaker. B attery Fail (LED 3) improper battery voltage. G round Fault (LED 4) ground fault on the panel. G round Fault (LED 5) ground fault on the panel. Trouble Indicators: Negative Ground Fault Positive Ground Fault Battery Fail AC Power Fail not used Figure 2.13 MPS-24A Main Power Supply Status Indicators 2.13 AVPS-24 Audio Visual Power Supply, Status Indicator The AVPS-24 includes a trouble LED (yellow LED, normally off) that lights to show the following trouble conditions: 1) a power supply malfunction; 2) loss of AC line voltage; Trouble LED 3) low AC line voltage; 4) open circuit breaker; or 5) open battery lead. Figure 2.14 The Audio Visual Power Supply (AVPS-24) 16 System 5000 Operation 15581:C 04/17/97

Section 3 Periodic Testing and Maintenance 3.1 Periodic Testing and Servicing Periodic testing and servicing, by qualified service personnel, is essential to ensure proper and reliable operation. Test and service according to the schedules and procedures outlined in: 1) NFPA standard 72-1993, Chapter 7 Inspection, Testing, and Maintenance ; 2) System 5000 Troubleshooting Manual; and 3) service manuals and instructions for the system peripheral devices. Report any trouble condition or malfunction to your service representative immediately. 3.2 Operational Checks Between formal periodic testing and servicing intervals, do the following operation checks monthly or more often as required by the Authority Having Jurisdiction. 1) Check that the green AC Power LED is on. 2) Check that all yellow LEDs are off. 3) Press and hold System Reset. All System 5000 LEDs should light sequentially. 4) Before activating any part of the system: a) notify fire department and/or central alarm receiving station if alarm conditions are transmitted; b) notify facility personnel of the testing, so that alarm sounding devices are ignored during test period; c) when necessary, prevent activating alarm signaling devices by pressing the On/Off switch on the signaling circuit(s) to be disabled, while pressing and holding the Disable/Enable switch. 5) Activate an initiating zone through an alarm initiating device and check that active signaling devices sound, and alarm indicators light. Check the paging function (if connected). Reset alarm initiating devices and the System 5000. 6) Repeat step 5 for each initiating zone 7) If the system contains fire fighter telephones, check operation of each telephone circuit. 8) Enable any signaling circuit(s) disabled in step 4(c). To enable a circuit press the On/Off switch on the disabled circuit(s) while pressing and holding the Disable/Enable switch. 9) Check that all yellow LEDs are off and that the green AC Power LED is lit. Reset all installed equipment. 10) When finished testing, immediately notify fire, central station and/or building personnel. System 5000 Operation 15581:C 04/17/97 17

Limited Warranty NOTIFIER warrants its products to be free from defects in materials and workmanship for eighteen (18) months from the date of manufacture, under normal use and service. Products are date stamped at time of manufacture. The sole and exclusive obligation of NOTIFIER is to repair or replace, at its option, free of charge for parts and labor, any part which is defective in materials or workmanship under normal use and service. For products not under NOTIFIER manufacturing date-stamp control, the warranty is eighteen (18) months from date of original purchase by NOTIFIER 's distributor unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. This warranty is void if the product is altered, repaired or serviced by anyone other than NOTIFIER or its authorized distributors or if there is a failure to maintain the products and systems in which they operate in a proper and workable manner. In case of defect, secure a Return Material Authorization form from our customer service department. Return product, transportation prepaid, to NOTIFIER, 12 Clintonville Road, Northford, Connecticut 06472-1653. This writing constitutes the only warranty made by NOTIFIER with respect to its products. NOTIFIER does not represent that its products will prevent any loss by fire or otherwise, or that its products will in all cases provide the protection for which they are installed or intended. Buyer acknowledges that NOTIFIER is not an insurer and assumes no risk for loss or damages or the cost of any inconvenience, transportation, damage, misuse, abuse, accident or similar incident. NOTIFIER GIVES NO WARRANTY, EXPRESSED OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. UNDER NO CIRCUMSTANCES SHALL NOTIFIER BE LIABLE FOR ANY LOSS OF OR DAMAGE TO PROPERTY, DIRECT, INCIDENTAL OR CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR INABILITY TO USE NOTIFIER PRODUCTS. FURTHERMORE, NOTIFIER SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF, OR AS A RESULT OF, PERSONAL, COMMERCIAL OR INDUSTRIAL USE OF ITS PRODUCTS. This warranty replaces all previous warranties and is the only warranty made by NOTIFIER. No increase or alteration, written or verbal, of the obligation of this warranty is authorized. "NOTIFIER" is a registered trademark. 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Technical Publishing Document WARNBG-C.P65 04/02/96