POLYMER positive-temperature-coefficient (PPTC) resettable

Similar documents
Implementing a Reliable Leak Detection System on a Crude Oil Pipeline

ON-LINE SENSOR CALIBRATION MONITORING AND FAULT DETECTION FOR CHEMICAL PROCESSES

The Use of Fuzzy Spaces in Signal Detection

Benefits of Enhanced Event Analysis in. Mark Miller

Implementation of High Throughput Radix-16 FFT Processor

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

1066. A self-adaptive alarm method for tool condition monitoring based on Parzen window estimation

Global Journal of Engineering Science and Research Management

False Alarm Analysis of the CATM-CFAR in Presence of Clutter Edge

The effect of write current on thermal flying height control sliders with dual heater/insulator elements

A Novel Algorithm for Intelligent Home Energy Management System

Fuzzy Logic Based Coolant Leak Detection

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Reduction of False Alarm Signals for PIR Sensor in Realistic Outdoor Surveillance

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

A Study on Process Capability on Connecting Rod in Assembly Line

Compression of Fins pipe and simple Heat pipe Using CFD

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Flexibility, scalability andsecurity

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

Failure Modes, Effects and Diagnostic Analysis

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Video Smoke Detection using Deep Domain Adaptation Enhanced with Synthetic Smoke Images

Battery Performance Alert

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Fire Detection Using Image Processing

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b

Research Article Footstep and Vehicle Detection Using Seismic Sensors in Wireless Sensor Network: Field Tests

Alarm Correlation Research and Implementation Based on Similar Data Sources

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

ENSC 388: Engineering Thermodynamics and Heat Transfer

Applied Data Science: Using Machine Learning for Alarm Verification

UL268 7 th challenge with single infrared smoke detector

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Virtual Refrigerant Pressure Sensors for Use in Monitoring and Fault Diagnosis of Vapor- Compression Equipment

American International Journal of Research in Science, Technology, Engineering & Mathematics

Brief Contributions. Vulnerability of Sensor Networks to Unauthorized Traversal and Monitoring 1 INTRODUCTION 2 PROBLEM FORMULATION

Results of Recent DOE Research on Development of Cable Condition Monitoring and Aging Management Technologies

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Advanced HART Diagnostic Suite

AS a principal element of a large-scale power plant, it is essential

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Intrusion Detection System: Facts, Challenges and Futures. By Gina Tjhai 13 th March 2007 Network Research Group

Design of Humidity Monitoring System Based on Virtual Instrument

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Application Note. Application Note for BAYEX

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

WeatherLink for Alarm Output Addendum

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

2. HEAT EXCHANGERS MESA

Experimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss

Altanium Temperature Controllers

Use of Autoassociative Neural Networks for Signal Validation

Statistical Analysis of Criteria and Key Aspects for Urban Design Quality Assessment of Built Environment

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Model Predictive Control of Pilot Spray Dryer Unit Designed and implemented for an Educational Institute

A Monte Carlo Approach for the Design of Thermal Fire Detection System

Study on the North China Rural Water Supply Project O&M Cost Standard Rating

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d

Reliability and availability analysis of a 10 K helium refrigerator

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Performance Study of Triple Concentric Pipe Heat Exchanger

Computers and Chemical Engineering

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Stability of Inclined Strip Anchors in Purely Cohesive Soil

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Experimental Study of Dual Heater Slider Touchdown Detectability

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Temperature Data Logging

White Paper: Video/Audio Analysis Technology. hanwhasecurity.com

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Transcription:

420 IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, VOL. 12, NO. 2, JUNE 2012 Anomaly Detection of Polymer Resettable Circuit Protection Devices Shunfeng Cheng, Member, IEEE, KwokTom,Member, IEEE, and Michael Pecht, Fellow, IEEE Abstract As circuit protection devices, failure or abnormal behavior of polymer positive-temperature-coefficient resettable devices can cause damage to circuits. It is necessary to detect anomalies in the resettable circuit protection devices to provide early warning of failure and avoid damage to a circuit. In this paper, a novel anomaly detection method, the cross-validation-based sequential probability ratio test, is developed and applied to the failure precursor parameters of the resettable circuit protection devices to conduct anomaly detection. The cross-validation-based sequential probability ratio test integrates the advantages of both the sequential probability ratio test for in situ anomaly detection and the cross-validation technique for model parameter selection to reduce the probability of false and missed alarms in anomaly detection. The cross-validation-based sequential probability ratio test solves the model parameter selection difficulty of the traditional sequential probability ratio test and improves its performance in anomaly detection. Index Terms Anomaly detection, cross-validation-based sequential probability ratio test, failure precursor parameter, polymer positive-temperature-coefficient (PPTC) resettable circuit protection device, power supply protection. Fig. 1. device. Picture of a radial through-hole PPTC resettable circuit protection I. INTRODUCTION POLYMER positive-temperature-coefficient (PPTC) resettable circuit protection devices are widely used to protect circuits in electronics, such as automotive circuits (e.g., the protection of micro-motors in window lifts, seats, and door locks), computers (e.g., the protection of the circuits in hard disk drives, interface ports, and cooling fan motors), telecommunication devices (e.g., cell phones), power supplies of various devices (e.g., computer, medical devices, and security and alarm systems) and batteries (e.g., Lithium-ion/Lithium battery, Nickel Cadmium cells, and Nickel Metal Hydride battery) [1] [4]. Although there are different types of package styles of PPTC resettable circuit protection devices, such as surface mount and Manuscript received July 15, 2011; revised September 10, 2011; accepted September 26, 2011. Date of publication October 6, 2011; date of current version June 6, 2012. S. Cheng was with the Prognostics and Health Management Consortium, Center for Advanced Life Cycle Engineering, University of Maryland, College Park, MD 20742 USA. He is now with Intel, Hillsboro, OR 97124 USA (e-mail: shunfengcheng@gmail.com). K. Tom is with the Army Research Laboratory, Adelphi, MD 20783 USA (e-mail: kwok.tom.civ@mail.mil). M. Pecht is with the Center for Advanced Life Cycle Engineering, University of Maryland, College Park, MD 20742 USA, and also with the Centre for Prognostics and System Health Management, City University of Hong Kong, Hong Kong, China (e-mail: pecht@calce.umd.edu). Color versions of one or more of the figures in this paper are available online at http://ieeexplore.ieee.org. Digital Object Identifier 10.1109/TDMR.2011.2170689 Fig. 2. Operation process of a PPTC resettable circuit protection device. radial through-hole styles (shown in Fig. 1), the operational principles and processes are the same for each. Fig. 2 shows a schematic drawing of the operational process of a typical PPTC resettable circuit protection device [1]. Under normal ambient temperature, the PPTC resettable circuit protection device works in a low resistance state when the normal current (less than the hold current, I hold, which is the maximum steady-state current the device can carry without tripping at the ambient temperature) passes through it. When a fault current (higher than the trip current, I trip, which is the minimum current that causes the device to trip at the ambient temperature) occurs, the resistance of the PPTC circuit protection device increases sharply. Because of the sharp increase in resistance, the current is decreased to protect the circuit. The sharp increase in resistance is called a trip. After the trip, a PPTC resettable circuit protection device does not break as does a traditional fuse. Instead, it maintains a high resistance state and allows a small 1530-4388/$26.00 2011 IEEE

CHENG et al.: ANOMALY DETECTION OF RESETTABLE CIRCUIT PROTECTION DEVICES 421 trickle current to pass through the circuit. The PPTC resettable circuit protection device will reset to a low resistance state within a short time after the heat or fault current is removed and/or the power is switched off [1], [5] [7]. The trip time is defined as the time required for a PPTC resettable circuit protection device to decrease the current of the circuit to 50% of the trip current at the ambient temperature [7]. When the current is higher than the trip current, the PPTC circuit protection device will trip. When the current is lower than the hold current, the device will not trip. When the current is between the hold current and the trip current, the device may or may not trip [6], [7]. After a number of trip reset cycles, the PPTC resettable circuit protection device will degrade and failures will occur [1]. Although the PPTC resettable circuit protection device is not intended to be used under repeated faults or prolonged tripped conditions, the actual operation of the device will be in a trip hold reset condition if it is tripped by abnormal conditions. When a PPTC resettable circuit protection device is tripped, it may hold the tripped state until it is reset. After a number of trip hold reset operations, the circuit protection performance of the device will degrade. Failure or abnormal behavior of PPTC resettable circuit protection devices may cause damage to circuits, abnormal operation of circuits (e.g., inability to work at normal current), or unnecessary operations that force operators to switch off and on the power to reset the circuit. It is necessary to monitor the PPTC resettable circuit protection devices in situ to provide advance warning of failures and predict the remaining useful life (RUL) of the devices to prevent damage to the circuits. Prognostics and health management (PHM) has been emerged as an effective method to monitor systems in situ and provide an RUL estimate. PHM is an enabling discipline consisting of technologies and methods to assess the reliability of a product in its actual life cycle conditions to determine the advent of failure and mitigate system risk [8], [9]. PHM can be implemented by data-driven methods, which can extract information, detect anomalies, and identify trends from the in situ monitored product data[9], [10]; model-based methods, which are based on an understanding of the physical processes that cause degradation and failures of a product [9], [10]; and the fusion of these two methods [10], [11]. Typically, anomaly detection is a necessary process for datadriven PHM methods to provide advanced warning. This paper focuses on using a cross-validation-based sequential probability ratio test (CV-SPRT) to conduct anomaly detection on in situ monitored failure precursor parameters to provide early warning of failure of PPTC resettable circuit protection devices. CV-SPRT can solve the problem of model parameter selection faced by traditional SPRT and reduce false alarms and missed alarms from anomaly detection. II. FAILURE PRECURSOR PARAMETERS Failure modes, mechanisms, and effects analysis (FMMEA) [12], [13] and a series of experimental tests were conducted to determine the failure precursor parameters of PPTC resettable circuit protection devices. The failure modes of PPTC TABLE I POTENTIAL FAILURE PRECURSOR PARAMETERS resettable circuit protection devices were defined by authors as follows [1]. 1) A device trips at less than normal current ( I hold ) at the specific ambient temperature. 2) A device does not trip at fault current ( I trip ) at the specific ambient temperature. 3) Deviations in the trip time (trip time becoming longer or shorter). Trip in a longer time increases the risk of damage to the circuit because of the longer exposure of the circuit to a high fault current. A shorter trip time makes the circuit more likely to be disturbed by noisy currents, which may result in unnecessary faults in circuit operation. 4) A device becomes high in resistance after reset. The increase in resistance after reset shortens trip time and decreases the voltage drops on other components, which may cause abnormal operation of the circuit. 5) Opens or increases in resistance occur at the physical internal connections between different parts of a device. 6) Physical cracks, breaks, separations, and/or degradation in the dielectric materials occur in the outside package. Table I shows the potential precursor parameters based on the results of FMMEA. The current through the device, the voltage across the device, and the surface temperature of the device can be monitored in situ. The resistance during the trip can be calculated by Ohm theory using the monitored current and voltage. The resistance after trip can be measured by a datalogger using a 4-wire connection. Trip time can be calculated by the difference between the time when the fault current occurs and the time when the current decreases to the hold current. This can be measured by a current meter or sensors. Trip cycle tests were designed to determine whether the trip time, current, resistance, and surface temperature are indicators of degradation in PPTC resettable circuit protection devices. Trip cycle tests were conducted at four different ambient temperature conditions: 10 C, room temperature (RT, 19 C 23 C), 60 C, and 85 C, respectively. Four samples were tested in each condition. In each cycle, current through the circuit protection device, voltage across the device, surface temperature, trip time, and resistance in the resetting process (power switched off) of the device were monitored. Fig. 3 shows the setup of the trip cycle test. The Labview program was used to control a data-logger and the VEE program was used to control a 4-channel power supply, each channel of

422 IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, VOL. 12, NO. 2, JUNE 2012 Fig. 3. Trip cycle test setup. Fig. 5. Trip time at different conditions (each point is the average of every 100 cycles). Fig. 4. Current profile in one trip cycle (current versus time). which provided power to one PPTC resettable circuit protection device. The VEE program recorded the time when the initial high current occurred and the time when the current reduced to the hold current at ambient conditions; it then calculated the trip time of each trip cycle. An Agilent Data Logger 34970 A was used to monitor the resistance in the resetting process and the surface temperatures of each PPTC device. A 4-wire connection resistance measurement was used to remove the effects of the wire and the connection. The surface temperature was measured by thermocouples, each of which was attached on each side of the PPTC circuit protection device; the maximum temperature of these two thermocouples was used to determine the surface temperature of the device. Fig. 4 shows the current profile in one trip cycle. When the power was switched on, a high current was input to the PPTC circuit protection device (20 A for all conditions). The PPTC device was heated by Joule heat and tripped to a high resistance state in several seconds. When the current reduced to the specified hold current at the environmental temperature, the power supply was kept on for 1 additional minute (called 1 minute trip endurance). After that, the power was switched off for 7 minutes to cool the PPTC device and reset it to a low resistance state. Based on the experimental results, the analysis of correlations among the monitored parameters, and the mapping between the changes in monitored parameters and the observed failures, trip time, resistance after reset, and surface temperature were determined as precursor parameters. Since a high correlation between the trip time and surface temperature was observed, and since trip time always indicate failures earlier than surface temperature can, it is reasonable to use trip time (as shown in Fig. 5) and resistance after reset (as shown in Fig. 6) to conduct anomaly detection of PPTC resettable circuit protection devices. Fig. 6. Minimum resistance after reset at different conditions (each point is the average of every 100 cycles). III. CROSS-VALIDATION-BASED SPRT (CV-SPRT) There have been no publications on anomaly detection of PPTC resettable circuit protection devices. In this paper, a novel method, CV-SPRT, is developed to monitor the trip time and resistance after reset to detect anomalies. CV-SPRT combines the advantages of both SPRT in in situ anomaly detection and CV in model parameter selection to reduce the number of false and missed alarms. SPRT is a sequential statistical binary hypothesis test introduced by Wald [14]. SPRT is different from traditional hypothesis testing where it is only after all the data are collected that analysis is conducted and conclusions are drawn [15]. In SPRT, single data is monitored in situ and analyzed directly once it is collected. This ability enables SPRT for the detection of statistical changes against a null hypothesis at the earliest possible time or with the smallest sample size [14]. SPRT has been used in in situ monitoring, anomaly detection, and decision making for electronics, structures, and process controls [10], [16]. General anomaly detection using SPRT is shown in Fig. 7. The training data, which are healthy data from a system, can be obtained from historic data or from stable operational phases when the product is known to be healthy. Statistical features of the training data, such as the distribution, are extracted to create a detection baseline. In the detection procedure, in situ

CHENG et al.: ANOMALY DETECTION OF RESETTABLE CIRCUIT PROTECTION DEVICES 423 Fig. 7. Anomaly detection procedure using SPRT. are used to calculate the SPRT index for mean shift to higher, mean shift to lower, variance increase, and variance decrease of the monitored data, respectively. SPRT 1 = M σ 2 SPRT 2 = M σ 2 SPRT 3 = SPRT 4 = n n n x 2 i i 1 2σ 2 n x 2 i i 1 ( x i M ) 2 ( x i M ) 2 (3) (4) ( 1 1 ) (n/2)lnv (5) V (1 V )+(n/2)lnv. (6) 2σ2 Fig. 8. SPRT procedure. monitored data are compared with the baseline sequentially using SPRT to detect anomalies. The binary hypothesis of SPRT includes one null hypothesis and one or more alternative hypotheses. For a normal distribution, the null hypothesis H 0 represents the healthy state, with mean = 0 and standard deviation = σ. The alternative hypothesis includes four cases: 1) H 1 : the mean of the test data has shifted high to +M, with no change in standard deviation; 2) H 2 : the mean of the test data has shifted low to M, with no change in standard deviation; 3) H 3 : the variance of test data has increased to Vσ 2, with no change in mean; 4) H 4 : the variance of test data has decreased to σ 2 /V, with no change in mean. M and V are the predetermined system disturbance magnitudes, which are decided by the user, and in general they are several times the standard deviation of the training data. Fig. 8 shows the procedure of SPRT. The SPRT calculates the SPRT index for each in situ monitored data point and compares the SPRT index with the boundary to make a decision. The SPRT index is the natural logarithm of the ratio of the probability that accepts the null hypothesis to the probability that accepts the alternative hypothesis, as shown in equation SPRT j =ln(lr j )= n ln Pr(x i H j ) Pr(x i H 0 ) where SPRT j=1 4 is the SPRT index and LR j is the likelihood ratio for an independent process. H j is the jth alternative (unhealthy) hypothesis discussed above and H 0 is the null (health) hypothesis. SPRT j is defined by equation LR j = probability of sequence {X n} given H j true probability of sequence {X n } given H 0 true n n Pr(x i H j ) = Pr(x i H 0 ) = f j (x i ) f 0 (x i ). (2) The SPRT index can be calculated as long as the distribution of the detected data is available. Four SPRT index formulas for normal distribution are shown in Equations (3) (6) [19]. They (1) SPRT uses the probabilities of missed alarms and false alarms to create the thresholds of acceptance and rejection of the null hypothesis, as shown in equation A =ln ( ) β, B =ln 1 α ( 1 β α ). (7) Each SPRT index is compared to the decision boundaries (A, B). For each comparison, there are three possible outcomes: 1) the lower limit is reached, in which case the healthy hypothesis (H 0 ) is accepted, the corresponding index is reset, and sampling continues; 2) the upper limit is reached, in which case the alarm is given, the corresponding index is reset, and sampling continues; or 3) neither limit is reached, in which case the information is not sufficient to make a conclusion, and the sampling continues. Four model parameters should be determined for SPRT detection: the system disturbance magnitude, M, which is m times the standard deviation of the training data; the variation factor, V ; the false alarm probability, α; and the missed alarm probability, β. In practice, these model parameters are selected by experience. Even though the system disturbance magnitudes selected are in this recommended range [19], [20], the actual false alarm probability and/or missed alarm probability may be higher than the user-allowed values. Developing a systematic model parameter selection method for SPRT is necessary to improve its performance and reduce false and missed alarms. However, based on our literature review, there is no publication on a systemic method for SPRT model parameter selection. Some methods, such as simulated annealing algorithms [21], [22], genetic algorithms [23], [24], and particle swarm optimization [25], are reported as general model parameter selection and optimization methods. However, all these optimization methods are required to optimize their own parameters first; otherwise, the performance of these optimization algorithms will be affected. In this paper, a k-fold cross-validation (CV) [26] [28] method is used as a systematic method to select a proper model parameter set (m, V, α, β) for SPRT without the need for experience. CV is much simpler and more accurate than other methods. The shortcoming of CV is its relatively high computation power consumption.

424 IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, VOL. 12, NO. 2, JUNE 2012 Fig. 10. Adding an abnormal data set into an original validation data set to calculate the missed alarm probability (V: validation data set; A: abnormal data set). TABLE II RANGE AND CHANGE INTERVAL OF SPRT MODEL PARAMETERS Fig. 9. Model parameter selection procedure by k-fold CV. The procedure of model parameter selection by k-fold CV is shown in Fig. 9. The first step is to select the training data set, which is composed entirely of healthy data, which become the training data for SPRT after the proper model parameter set is obtained. After the training data is selected, a model parameter set (m, V, α, β) is assigned to SPRT. For each assigned model parameter set, the actual false alarm probability (α ) and missed alarm probability (β ) are then calculated by k-fold CV, whose process is indicated by the flowchart inside the dashed box. In the k-fold CV process, all of the training data are partitioned into k subsets of equal or nearly equal size. A total of k iterations should be conducted to calculate the actual false alarm probability (α ) and missed alarm probability (β ).In each of the k iterations, one different subset is selected as the original validation data, and the remaining k 1 subsets are the training data. If SPRT is only run on the original validation data, which is all healthy data, only the false alarm probability can be calculated. In order to calculate the actual missed alarm probability of SPRT, an abnormal data set should be added into the original validation data set, shown as the filled-in boxes in Figs. 9 and 10. The abnormal data set can be generated by randomly picking up data outside of the range of [μ m σ, μ + m σ]. Here, the μ and σ are the mean and standard deviation of the training data in each CV iteration (the remaining k 1 subsets of the entire training data). In each iteration, both false alarms and missed alarms can be identified based on a comparison of the detection results with the validation data and abnormal data. The false alarm probability and missed alarm probability can be calculated by equations (8) and (9). The process is repeated k times until each of the subsets has been selected as the original validation data set. The mean of the k false alarm probabilities and the mean of the k missed alarm probabilities are calculated by equations (10) and (11) as the final false alarm probability (α ) and final missed alarm probability (β ) when using all of the training data (without the abnormal data) and the selected model parameter set α i Number of false alarms in i th iteration = Number of original validation data in i th iteration (8) β i = Number of missed alarms in ith iteration Number of abnormal data in i th (9) iteration α = 1 k α i (10) β = 1 k β i. (11) The actual false alarm probability and missed alarm probability are compared with the ones in the selected model parameter set. If both the final false alarm probability and the missed alarm probability are less than the user-specified false alarm probability and missed alarm probability, respectively, the model parameter set is considered as a proper model parameter set for SPRT, but it might not be the optimal model set. The optimal model parameter set can be defined as the one with the minimum error probability, which is the minimum sum of the false and missed alarm probabilities. If the criteria are not satisfied, another model parameter set based on the range and interval in Table II should be re-assigned and the performance of the SPRT with the model parameter should be evaluated by k-fold CV again. A model parameter set should be updated when the training data are updated since the actual false alarm and missed alarm probabilities are calculated based on the specific training data.

CHENG et al.: ANOMALY DETECTION OF RESETTABLE CIRCUIT PROTECTION DEVICES 425 IV. ANOMALY DETECTION RESULTS OF PPTC RESETTABLE CIRCUIT PROTECTION DEVICES As a demonstration, trip time under 10 C(asshownin Fig. 5) condition was used individually for anomaly detection by CV-SPRT. First, the first 20 trip-time data points, which represents the trip-time values in the first 2000 cycles, were selected as training data for anomaly detection of trip time. The data may be normalized first using equation (12), where x i is normalized data, x i is original data, and μ and σ are the mean and standard deviation of the training data, respectively. If the data are not normally distributed, a transformation, such as the Box Cox transformation [29] or the Johnson transformation [30], may be used to transform the data into a normal distribution. Here, the normalized training data was normally distributed x i = x i μ. (12) σ Then the model parameters (m, V, α, β) were determined by the k-fold CV process. Parameter k of a k-fold CV is determined based on the size of the training data. If the size is small, a higher k can be chosen. Otherwise, a lower k should be chosen. The higher the k, the more accurate the error rate calculation is. However, the variance of the detection error rate estimation becomes large and the entire CV process is more time-consuming. In this case, 5-fold CV is chosen. An abnormal data set with 20 abnormal data points, which were randomly generated out of the range of [μ m σ, μ + m σ], were added into each validation set. Here, the μ and σ are the mean and standard deviation of the remaining 4 subsets of the training data in each iteration. The updated validation data set is used to calculate the actual false alarm and missed alarm probabilities in each iteration. After the 5-fold CV process, the SPRT model parameter set (m = 4, V =4, α = 0.005, and β = 0.01) was selected for trip-time data under 10 C condition. The SPRT then used these model parameters and the training data to detect the anomalies in situ when a new trip-time data point was collected. Fig. 11 shows the anomaly detection results of trip time using the model parameter set (4, 4, 0.005, 0.01), by which no false alarms or missed alarms were reported. Fig. 12 is a plot of anomaly detection for the trip time using a randomly picked model parameter set (2, 2, 0.02, 0.01), by which some false alarms (shown in zoom-in view) were detected in the training data. CV can identify more than one proper model parameter sets for SPRT and can ensure the selection of the model parameter set with lowest sum of false and missed alarm rates among all the proper model parameter sets. Therefore, CV-SPRT can reduce the error rate of the anomaly detection. One point that should be clarified is that in anomaly detection the false alarm is the alarm triggered by signal that is not defined as an anomaly (for example, anomalies detected in training data are false alarms), instead of an anomaly detected before failure. Detection of an anomaly before failure is a valuable early warning of failure. Early warning allows people to take actions, such as maintenance and replacement, to avoid the occurrence of failures. The other point is that the actual false Fig. 11. Anomaly detection of trip time under 10 C conditions. Fig. 12. Anomaly detection of trip time under 10 C conditions using model parameters (2, 2, 0.02, 0.01) (false alarms detected). alarm or missed alarm rate is affected by the combination of all four parameters in the set. So when we randomly chose a model parameter set, the actual false alarm and/or missed alarm rates may be higher than what were expected; while the model parameter set selected by CV-SPRT had a minimum error rate across all the proper model parameter sets. Table III summarizes the anomaly detection results for PPTC resettable circuit protection devices based on trip time and resistance after reset for all test conditions. The anomaly detection provides the times (cycles) and the corresponding parameters

426 IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, VOL. 12, NO. 2, JUNE 2012 TABLE III SUMMARY OF ANOMALY DETECTION RESULTS (TT: TRIP TIME; MINR: MINIMUM RESISTANCE AFTER RESET) that triggered the alarms. The earliest anomaly among all the precursor parameters was reported as the earliest anomaly for the PPTC resettable circuit protection device. The detection results showed that the CV-SPRT can provide advance warning of actual failures. V. C ONCLUSION In this paper, CV-SPRT was developed for anomaly detection for PPTC resettable circuit protection devices. CV-SPRT can optimize the model parameter set (m, V, α, β) for SPRT without the need for experience to reduce the probability of false and missed alarms. The applications of CV-SPRT on PPTC resettable circuit protection devices showed that CV-SPRT can detect anomalies in advance and provide early warnings of actual failures with a lower error rate than traditional SPRT. Besides anomaly detection for PPTC resettable circuit protection devices, CV-SPRT can be extended to conduct anomaly detection for any conditions and products if the training data and its distribution are available. The model parameter set selection process by the CV method should be conducted once the training data is obtained, and the model parameter set must be updated for each updating of the training data. The whole model parameter selection process is easy to build into the procedure of SPRT as a part of SPRT software and can improve the online monitoring accuracy of SPRT by reducing the detection errors caused by improper model parameters. One shortcoming of the CV-SPRT method is that the computing time may be longer if the size of the training data set is large. But with an increase in the capability of the computer, this will not be a challenge. ACKNOWLEDGMENT The authors would like to thank the companies and organizations that support research activities at the Center for Advanced Life Cycle Engineering (CALCE) at the University of Maryland. The authors would also like to thank the members of the Prognostics and Health Management Consortium at CALCE for their support of this work. REFERENCES [1] S. Cheng, K. Tom, and M. Pecht, Failure precursors for polymer resettable fuses, IEEE Trans. Device Mater. Rel., vol. 10, no. 3, pp. 374 380, Sep. 2010. [2] Bourns, Multifuse Application Note: Lithium-ion/Lithium Polymer Battery Pack Protection, Jun. 6, 2011. [Online]. Available: http://www. bourns.com/pdfs/appnotes_lilp.pdf [3] Tyco Electronics, Application Note: Circuit Protection Solutions for Security and Fire Alarm Systems, Jun. 6, 2011. [Online]. Available: http:// www.digikey.com/web%20export/supplier%20content/tyco_8004/pdf/ Tyco_securityfirean.pdf?redirected=1 [4] Arrow Electronics, Application Sheet: Medical Circuit Protection, Jun. 6, 2011. [Online]. Available: http://www.arrownac.com/solutionsapplications/medical/pdfs/cp_bro.pdf [5] S. Luo and C. Wong, Study on effect of carbon black on behavior of conductive polymer composites with positive temperature coefficient, IEEE Trans. Compon., Packag., Manuf. Technol., vol. 23, no. 1, pp. 151 156, Mar. 2000. [6] Tyco Electronics, Fundamentals of PolySwitch Overcurrent and Overtemperature Devices, 2008, Technical Paper. [7] Standard for Safety for Thermistor-Type Devices, UL 1434, Aug. 2002. [8] S. Cheng, M. Azarian, and M. Pecht, Sensor system for prognostics and health monitoring, Sensors, no. 10, pp. 5774 5797, 2010. [9] M. Pecht, Prognostics and Health Management of Electronics. New York: Wiley-Interscience, 2008. [10] M. Pecht and R. Jaai, A prognostics and health management roadmap for information and electronics-rich systems, Microelectron. Reliab.,vol.50, no. 3, pp. 317 323, Mar. 2010. [11] S. Cheng and M. Pecht, A fusion prognostics method for remaining useful life prediction of electronic products, in Proc. 5th Annu. IEEE Conf. Autom. Sci. Eng., Bangalore, India, Aug. 22 25, 2009, pp. 102 107. [12] M. Pecht and A. Dasgupta, Physics-of-failure: An approach to reliable product development, J. Inst. Environ. Sci., vol. 38, pp. 30 34, Sep./Oct. 1995. [13] IEEE Guide for Selecting and Using Reliability Predictions Based on IEEE 1413, IEEE Standard, IEEE Std. 1413.1-2002, 2003. [14] A. Wald, Sequential Analysis. New York: Wiley, 1947. [15] H. Sohn, D. Allen, K. Worden, and C. Farrar, Statistical damage classification using sequential probability ratio tests, Struct. Health Monit., vol. 2, no. 1, pp. 57 74, Mar. 2003. [16] K. Whisnant, K. C. Gross, and N. Lingurovska, Proactive fault monitoring in enterprise servers, in Proc. Int. Conf. Comput. Des., Jun. 2005, pp. 3 10. [17] S. Cheng, K. Tom, and M. Pecht, A wireless sensor system for prognostics and health management, IEEE Sens. J., vol. 10, no. 4, pp. 856 862, Apr. 2010. [18] Z. Stoumbos and M. Reynolds, The SPRT control chart for the process mean with samples starting at fixed times, Nonlinear Anal., vol. 2, no. 1, pp. 1 34, Mar. 2001. [19] A. Miron, A wavelet approach for development and application of a stochastic parameter simulation system, Ph.D. dissertation, Univ. Cincinnati, Cincinnati, OH, 2001. [20] J. Herzog, S. Wegerich, R. Singer, and K. Gross, Theoretical basis of the multivariate state estimation technique (MSET), Argonne Nat. Lab., Argonne, IL, NT Tech. Memorandum 49, 1997. [21] P. F. Pai and W. C. Hong, Software reliability forecasting by support vector machines with simulated annealing algorithms, J. Syst. Softw., vol. 79, no. 6, pp. 747 755, Jun. 2006. [22] S. Lin, Z. Lee, S. Chen, and T. Tseng, Parameter determination of support vector machine and feature selection using simulated annealing approach, Appl. Soft Comput., vol. 8, no. 4, pp. 1505 1512, Sep. 2008. [23] K. Y. Chen, Forecasting systems reliability based on support vector regression with genetic algorithms, Reliab. Eng. Syst. Safety, vol. 92, no. 4, pp. 423 432, Apr. 2007. [24] A. Oliveira, P. Bragaa, R. Lima, and M. Cornélioa, GA-based method for feature selection and parameters optimization for machine learning regression applied to software effort estimation, Inf. Softw. Technol., vol. 52, no. 11, pp. 1155 1166, Nov. 2010.

CHENG et al.: ANOMALY DETECTION OF RESETTABLE CIRCUIT PROTECTION DEVICES 427 [25] X. Li, S. Yang, and J. Qi, A new support vector machine optimized by improved particle swarm optimization and its application, J. Central South Univ. Technol., vol. 13, no. 5, pp. 568 572, Oct. 2006. [26] B. Efron, Estimating the error rate of a prediction rule: Improvement on cross validation, J. Amer. Stat. Assoc., vol. 78, no. 382, pp. 316 331, Jun. 1983. [27] M. Browne, Cross validation methods, J. Math. Psychol., vol. 44, no.1, pp. 108 132, Mar. 2000. [28] M. Stone, Cross-validatory choice and assessment of statistical predictions (with discussion), J. Roy. Stat. Soc., Ser. B, vol. 36, no. 2, pp. 111 147, 1974. [29] G. Box and D. Cox, An analysis of transformations, J. Roy. Stat. Soc., Ser. B, vol. 26, no. 2, pp. 211 252, 1964. [30] Y. Chou, A. Polansky, and R. Mason, Transforming non-normal data to normality in statistical process control, J. Qual. Technol., vol. 30, no. 2, pp. 133 141, Apr. 1998. Shunfeng Cheng (M 08) received the B.S. and M.S. degrees in mechanical engineering from Huazhong University of Science and Technology, Wuhan, China, and the Ph.D. degree from the Center for Advanced Life Cycle Engineering, University of Maryland, College Park. He was working on nondestructive testing methods and technology before 2006. Since 2006, he has been working on sensor systems for prognostics and health management, advanced data-driven methods, and physics of failure methods for prognostics. He is currently a Process TD Engineer with Intel, Hillsboro, OR. Michael Pecht (F 92) received the M.S. degree in electrical engineering and the M.S. and Ph.D. degrees in engineering mechanics from the University of Wisconsin, Madison. He is the Founder of the Center for Advanced Life Cycle Engineering, University of Maryland, College Park, which is funded by over 150 of the world s leading electronics companies. He is also a Chair Professor in mechanical engineering and a Professor in applied mathematics with the University of Maryland. He is also with the Centre for Prognostics and System Health Management, City University of Hong Kong, Kowloon, Hong Kong. He is the Chief Editor for Microelectronics Reliability. He has written more than 20 books on electronic product development, use, and supply chain management and over 400 technical articles. He has consulted for over 100 major international electronics companies, providing expertise in strategic planning, design, test, prognostics, IP, and risk assessment of electronic products and systems. Prof. Pecht is a Professional Engineer, an ASME fellow, and an IMAPS fellow. He was awarded the highest reliability honor, the IEEE Reliability Society s Lifetime Achievement Award, in 2008. He was the recipient of the European Micro and Nano-Reliability Award for outstanding contributions to reliability research, the 3M Research Award for electronics packaging, and the IMAPS William D. Ashman Memorial Achievement Award for his contributions in electronics reliability analysis. He served as Chief Editor of the IEEE TRANSACTIONS ON RELIABILITY for eight years and on the advisory board of IEEE SPECTRUM. He is an Associate Editor for the IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGY. Kwok Tom (M 74) received the B.S. and M.S. degrees in electrical engineering from The George Washington University, Washington, DC. He is employed by the Army Research Laboratory, Adelphi, MD. A significant amount of his time has been spent in the design of the fuse in the PATRIOT PAC-2 missile system. His work has been in the areas of flight test analysis, simulation, and evaluation of improved signal processors for target detection; target detection algorithm development; target signature collection; and hardware-in-the-loop evaluation of the various fuse designs; he has been a Contracting Officer Technical Representative on the development of fuse design and a Technical Consultant to the Lower Tier Project Office. From 1993 to 1995, he was the Team Leader for the signal processing team on the Steel Crater program dealing with the application of ultrawideband radar in the detection and identification of underground objects. From 1995 to 1999, he was the Team Leader on the development of a Ka-band monopulse fully polarimetric instrumentation-grade radar system. He has been an integral part of the prognostic and diagnostics program since 2004 and is currently the Team Leader for the P&D for the condition-based maintenance program.