Shell-and-Tube Heat Exchanger (Four Passes) - Optional

Similar documents
Heat Exchangers and Advanced Temperature Measurement Temperature

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

Familiarization with the Training System

The Refrigeration Cycle

The Refrigeration Cycle

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

Geothermal Training System (46126-A0)

Geothermal Training System

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

CAUTION. Installation Manual

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

STREBEL S-CB + Cascade Kits

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Technical data. Danfoss DHP-A

Job Sheet 1. Geothermal Energy OBJECTIVES. Familiarization with the training system components PROCEDURE

GP SERIES Packaged Chillers

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Planning guide. Atec.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

User Manual. Dryer Controller M720

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

MIX Boiler & Font Range Service Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Oakton TEMP 9500 Advanced Multiparameter Controller

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

2. HEAT EXCHANGERS MESA

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Variable Temperature Microprobe Systems

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

SHELL AND TUBE HEAT EXCHANGER (STHE) - part b

ECL Comfort 110, application 116

MEGATRON MODEL 2, 3, 4, and 5

United Electric Controls One Series Safety Transmitter Safety Manual

Dryer Controller M720

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

THERMAL ICE STORAGE: Application & Design Guide

EDS Solar Thermal ( )

Installation Manual. Instrucciones de instalación y manual de usuario 1

Please read this manual before switching the unit on. Important safety information inside. Dry - Well Temperature Calibrator.

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

DC200 Digital Dispenser Operating Manual

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

EVAPORATION NEEDS ENERGY

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

MASS. MARITIME ACADEMY

Precise Temperature Control; Compact Footprint

Mechanical Engineering Department Sheet (1)

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Thermostatic mixing valves with interchangeable cartridges

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Mix Boiler & Font Range ( #, #, #, , )

Instruction Manual Machine P/N: # & #

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

EUQA Humidifier, for circulated water

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Tune-Rite Software Operation Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Stratomaster Smart Single

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

46126-A2 Geothermal Training System

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CT224 Setup Tutorial

INSTALLATION ADJUSTMENT SERVICE

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

DIRTCAL - DIRTMAG dirt separator

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Product waste disposal - Protection of the environment:

Intelligent cascading kit

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

LOGIC CONTROLLED DEKO 25 EASE OF USE

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

LQQA Humidifier, for circulated water

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

Electric radiator tests

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Bench-Top Vacuum Oven with 28 segments programmable controller

P550W Series Air Dryers

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Reacti-Therm I and III Heating Modules

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Surna 25-Ton Chiller Operating & Maintenance Manual

Transcription:

Exercise 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the design and particularities of the four-pass shell and tube heat exchanger and you will have gained experience characterizing such an exchanger using the energy manager. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Description of a four-pass shell-and-tube heat exchanger Characteristics of the four-pass shell-and-tube heat exchanger Typical applications Using the four-pass shell-and-tube heat exchanger Typical installation. DISCUSSION Equipment symbol Description of a four-pass shell-and-tube heat exchanger A four-pass shell-and-tube heat exchanger is built on the same principles as the single-pass model (please see Ex. 2-3 for details) except that the array of tubes is manufactured in such a way as to make the tube fluid travel in the exchanger a total of four times before leaving the exchanger. This allows a prolonged thermal exposure of the inner fluid (the one in the tubes) with the shell fluid. Using a fourpass exchanger typically allows you to use a much shorter exchanger than if you were to use a single-pass one. This is a great advantage as a longer exchanger is more difficult to build and is typically much more cumbersome. In the example shown in Figure 2-21, the tube fluid enters the tubes and the heads of the exchanger which are designed in such a way as to redirect the fluid to allow for the four tube passes. Note that different designs can be used: You could use almost as many tube passes and shell passes as you want, but this makes the costs and complexity increase sharply without gaining in overall exchanger effectiveness (as each subsequent passes imply smaller and smaller temperature differences between the two process fluids). There is however a gain to be made in terms of the total heat exchanged. Festo Didactic 86011-00 83

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Discussion Figure 2-21. Interior of a typical four-pass shell-and-tube heat exchanger. Characteristics of the four-pass shell-and-tube heat exchanger The shell and tube heat exchanger used in the experiment is shown in Figure 2-22. flows in the tube array while fluid 2 flows in the shell around the tubes. 84 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Discussion 1 2 4 3 Figure 2-22. Four-pass shell-and-tube heat exchanger in counter-flow mode, Model 46905-C. Table 2-53 presents a summary of the main characteristics of the four-pass shelland-tube heat exchanger: Table 2-53. Four-pass shell-and-tube heat exchanger characteristics. Nominal surface (A) 0.242 m 2 (2.6 ft 2 ) Experimental overall heat transfer coefficient (U) for typical operating conditions: : T in = 32 C (90 F) : T in = 18 C (65 F) Flow of both fluids = 12 L/min (3 gal/min) Experimental pressure drops (for the operating conditions stated above) 1300 W/m 2 K (226 Btu/h ft 2 F) Side A (tubes) 5.5 kpa (0.7 psi) Flow direction for counter-flow operation See Figure 2-22 Side B (shell) 5.4 kpa (0.7 psi) Note that the counter-flow and parallel-flow modes of operation are not as clearly defined in a four pass shell-and-tube heat exchanger as it is in the case of a single pass one since the fluid changes direction many times in the four-pass exchanger. The initial direction of the fluid in the tube is used to define parallel and cross-flow modes. Festo Didactic 86011-00 85

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Discussion Typical applications Shell-and-tube heat exchangers are widely used in the industry, mainly because they can be tailored precisely to almost any situation and operating conditions. They can be designed to operate at almost any pressures and temperatures and they can be made to withstand vibration, fouling, corrosion, toxicity, radioactivity, and so on. The limitations of such exchangers are the budget and the availability of the materials chosen for your application. A main drawback is that a shell-andtube heat exchanger usually requires a larger surface area for a given heat exchange compared to a compact heat exchanger such as a plate heat exchanger. Using the four-pass shell-and-tube heat exchanger To ensure an efficient heat transfer as well as to extend the useful life of the heat exchanger, some precautions must be taken. Be sure to follow the guidelines presented in the following pages. Typical installation The following procedure describes the typical steps to install the heat exchanger for a counter-flow application. 1. Place the exchanger in place as indicated in Figure 2-23. 2. Using spring nuts and screws, secure the mounting bracket of the heat exchanger on the process workstation. 3. You may have to install elbow connectors on the ports of the heat exchanger to allow easy connection with other devices. 4. Install a strainer at the inlets to prevent dirt or impurities from clogging the heat exchanger (Ports 2 and 3 in Figure 2-22, while in counter-flow mode). 5. Connect the cold water source to port 2; this is the water that will be heated. The cold water comes from tank B. 6. Connect the hot water source to port 3. The warm water comes from tank A. 7. Connect hoses to port 1 and port 4 which are respectively the outlet of the cold water which was heated and the outlet of the hot water cooled by the exchange process. Make sure each fluid returns to its original tank. As shown in Figure 2-23, a strainer must be installed at the input port of both the cold and warm fluid inlets. This prevents impurities from clogging the heat exchanger. 86 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Outline Strainer (cool water input) Strainer (warm water input) Figure 2-23. Typical installation of the four-pass shell-and-tube heat exchanger. PROCEDURE OUTLINE The Procedure is divided into the following sections: Set up and connections Counter-flow mode measurements Characterization with equal flow rates. Characterization with a fixed flow rate and a variable flow rate. Characterization with a different input temperature for fluid 2. Parallel-flow mode measurements PROCEDURE Set up and connections 1. Verify that the emergency push button is wired so as to be able to cut the power in case of emergency. The Familiarization with the Training System manual covers the security issues related to the use of electricity with the system as well as the wiring of the emergency push button. 2. Make sure the 3531 system is properly set up to use the ing/cooling unit. 3. Connect the equipment according to the piping and instrumentation diagram (P&ID) shown in Figure 2-24 and use Figure 2-25 to position the equipment correctly on the frame of the training system. To set up your system for this exercise, start with the basic setup (minus the control valve) presented in the Familiarization with the Training System manual and add the equipment listed in Table 2-54. Drives 3 and 4 and pumps 3 and 4 must be connected to the setup as explained in the Familiarization with the Festo Didactic 86011-00 87

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Training System manual even though they are not shown explicitly in Figure 2-24. Table 2-54. Material to add to the basic setup for this exercise. Name Model Identification Four-pass shell-and-tube heat exchanger 46905-C - 4 Platinum RTDs 46917 Electromagnetic flow transmitter 46922-0 FIT A Electromagnetic flow transmitter 46922-1 FIT B Paperless recorder (if wished) 46972 - Energy manager 46974 UIY TE A1, TE A2, TE B1 and TE B2 Optionally, you may add the following equipment to measure pressure drops: Name Model Identification 4 Pressure ports 70-85808 - Differential pressure transmitter (high range) 46920 PDIT B Differential pressure transmitter (low range) 46921 PDIT A 88 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Figure 2-24. P&ID Four-pass shell-and-tube heat exchanger experiment. Festo Didactic 86011-00 89

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Figure 2-25. Setup Four-pass shell-and-tube heat exchanger experiment. 4. Do not power up the instrumentation workstation yet. Do not turn on the electrical panel or the heating/cooling unit before your instructor has validated your setup that is not before step 7. 5. Before proceeding further, complete the following checklist to make sure you have set up the system properly. The points on this checklist are crucial elements for the proper completion of this exercise. This checklist is not exhaustive, so be sure to follow the instructions in the Familiarization with the Training System manual as well. 90 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure f Every piece of equipment used is secured to the station with the appropriate bolt-and-nut mechanism. The heat exchanger is properly installed on the station. The hand valves are in the positions shown in the P&ID: Open valves: HV1A, HV1B, HV2A, HV2B, HV5A, and HV5B. Closed valves: HV3A, HV3B, HV4A, and HV4B. The hand valves under the drip trays are in the positions specified in the Familiarization with the Training System manual: Open valves: HV1A, HV1B, HV8A, and HV8B. Closed valves: HV6A, HV6B, and HV7. 6. Ask your instructor to check and approve your setup. 7. Power up the electrical unit. This powers the different measurement devices. Engage the circuits to power the four drives. 8. Start drives 3 and 4 (pumps P3 and P4). These pumps make the water of the two tanks flow in the heating/cooling unit. Ensure the process fluid from each tank is circulating correctly, then power up the heating/cooling unit. Make sure valve HV7 is closed. Continue with the next steps while the water in each tank is respectively heating and cooling toward their temperature set points. 9. Test your system for leaks. Use drives 1 and 2 to make pumps P1 and P2 run at low speed to produce a small flow rate. Progressively increase the frequency output of drives 1 and 2 up to 30 Hz. Repair any leaks that may arise. Optional: Configure, bleed and adjust your differential-pressure transmitters so as to be able to measure the pressure drops across the heat exchanger for each fluid. 10. The temperatures in the two tanks should be stable and at their respective set points by now. If this is not the case, identify the problem or wait a few minutes until the temperatures of the tanks stabilize. Festo Didactic 86011-00 91

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Counter-flow mode measurements Characterization with equal flow rates 11. Adjust the flow rates at 12 L/min (3 gpm) for the two fluids and let the temperature stabilize. Use the infrared thermometer to scan the heat exchanger. How does the temperature gradient look like? 12. Adjust the flow rates of the two fluids as prescribed in either Table 2-55 (SI units) or Table 2-56 (US customary units). Fill in the temperature and heat flow measurements as given by the energy manager. Wait until the readings are stable before recording the data. Discontinue the measurements if the heat flows become larger than about 2 tons 7 kw 24 000 Btu/h, especially if you notice that the heating/cooling unit cannot keep the cold water close to its set point. Optional: Record the pressure drops measured by the differential-pressure transmitters. Table 2-55. Four-pass shell-and-tube heat exchanger measurement Counter-flow SI units. flow 1 flow 2 (kpa) (kpa) 8.0 8.0 12.0 12.0 16.0 16.0 20.0 20.0 24.0 24.0 28.0 28.0 32.0 32.0 36.0 36.0 92 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Table 2-56. Four-pass shell-and-tube heat exchanger measurement Counter-flow US customary units. flow 1 flow 2 (psi) (psi) 1.0 1.0 2.0 2.0 3.0 3.0 5.0 5.0 6.0 6.0 7.0 7.0 8.0 8.0 9.0 9.0 13. Stop the pumps and use your results to perform the required calculations to complete either Table 2-57 or Table 2-58. The average heat flow is used in the calculations. It is strongly suggested to use a spreadsheet software to perform the calculations quickly. Finally, plot a graph of the average overall transfer coefficient as a function of the flow rate. Table 2-57. Four-pass shell-and-tube heat exchanger calculations Counter-flow SI units. Average flow (kw/m 2 C) 8.0 8.0 12.0 12.0 16.0 16.0 20.0 20.0 24.0 24.0 28.0 28.0 32.0 32.0 36.0 36.0 Festo Didactic 86011-00 93

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Table 2-58. Four-pass shell-and-tube heat exchanger calculations Counter-flow US customary units. Average flow (Btu/h ft 2 F) 1.0 1.0 2.0 2.0 3.0 3.0 5.0 5.0 6.0 6.0 7.0 7.0 8.0 8.0 9.0 9.0 Characterization with a fixed flow rate and a variable flow rate 14. Set the flow rate of fluid 1 to 16 L/min (4.0 gal/min) and keep it fixed at this value. Next, adjust the flow rate of fluid 2 so as to fill either Table 2-59 or Table 2-60. Let the heat flow readings stabilize before recording the values. Table 2-59. Four-pass shell-and-tube heat exchanger measurement Counter-flow of fluid 1 fixed SI units. flow 1 flow 2 Average heat flow 16.0 4.0 16.0 8.0 16.0 12.0 16.0 16.0 16.0 20.0 16.0 24.0 16.0 28.0 16.0 32.0 16.0 36.0 94 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Table 2-60. Four-pass shell-and-tube heat exchanger measurement Counter-flow of fluid 1 fixed US customary units. flow 1 flow 2 Average heat flow 4.0 1.0 4.0 2.0 4.0 3.0 4.0 5.0 4.0 6.0 4.0 7.0 4.0 8.0 4.0 9.0 Characterization with a different input temperature for fluid 2 15. Change the temperature set point of fluid 2 (in tank B) to 24 C (75 F). To do so: Locate the thermostat of the cooling circuit and press on the menu button. A blinking SP should appear on the screen. Press menu again to confirm. The current set point (18 C or 65 F) is displayed. Use the arrows to change the set point to 24 C or 75 F and press on the menu button to confirm. The set point is now adjusted. Let fluid 2 warm up to its new set point before continuing. Allow fluids 1 and 2 to circulate at high flow rates in the heat exchanger to speed up the heating process of the cold fluid. This takes a few minutes. Festo Didactic 86011-00 95

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure 16. Perform the same manipulations as in step 14 with fluid 2 now at a higher temperature. Note your measurements in one of the following tables: Table 2-61. Four-pass shell-and-tube heat exchanger measurement Counter-flow of fluid 1 fixed Warmer fluid 2 SI units. flow 1 flow 2 Average heat flow 16.0 4.0 16.0 8.0 16.0 12.0 16.0 16.0 16.0 20.0 16.0 24.0 16.0 28.0 16.0 32.0 16.0 36.0 Table 2-62. Four-pass shell-and-tube heat exchanger measurement Counter-flow of fluid 1 fixed Warmer fluid 2 US customary units. flow 1 flow 2 Average heat flow 4.0 1.0 4.0 2.0 4.0 3.0 4.0 5.0 4.0 6.0 4.0 7.0 4.0 8.0 4.0 9.0 How does the heat exchanger perform in the two cases? In which case is the heat exchange optimized? 96 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure 17. Reset the set point of fluid 2 to its normal value of 18 C (65 F). Let the temperature of fluid 2 adjust while you perform the next step. Parallel-flow mode measurements 18. Stop pumps 1 and 2. Modify the setup slightly to operate the exchanger in parallel-flow mode. Invert the inlet and the outlet of fluid 2 at the ports of the heat exchanger. You may need to change the elbow connectors and to use a special connector (a male-male adapter, P/N 87117). Make sure the strainer and the temperature probe TE B1 are located at the new input for fluid 2. The temperature of fluid 2 in the tank should be at its normal value of 18 C (65 F). If not, wait until it reaches its set point before continuing. 19. Adjust the flow rates at 12 L/min (3 gpm) for the two fluids and let the temperatures stabilize. Use the infrared thermometer to scan the heat exchanger. How does the temperature gradient look like? 20. Adjust the flow rates of the two fluids as prescribed in either Table 2-63 or Table 2-64. Fill in the temperature and heat flow measurements as given by the energy manager. Optional: Record the pressure drops measured by the differential-pressure transmitters. Table 2-63. Four-pass shell-and-tube heat exchanger measurement Parallel-flow SI units. flow 1 flow 2 (kpa) (kpa) 8.0 8.0 12.0 12.0 16.0 16.0 20.0 20.0 24.0 24.0 28.0 28.0 32.0 32.0 36.0 36.0 Festo Didactic 86011-00 97

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Procedure Table 2-64. Four-pass shell-and-tube heat exchanger measurement Parallel-flow US customary units. flow 1 flow 2 (psi) (psi) 1.0 1.0 2.0 2.0 3.0 3.0 5.0 5.0 6.0 6.0 7.0 7.0 8.0 8.0 9.0 9.0 21. Stop the pumps and use your results to perform the required calculations to complete either Table 2-65 or Table 2-66. The average heat flow is used in the calculations. It is strongly suggested to use a spreadsheet software to perform the calculations quickly. Finally, plot a graph of the average overall transfer coefficient as a function of the flow rate. Table 2-65. Four-pass shell-and-tube heat exchanger calculations Parallel-flow SI units. Average flow (kw/m 2 C) 8.0 8.0 12.0 12.0 16.0 16.0 20.0 20.0 24.0 24.0 28.0 28.0 32.0 32.0 36.0 36.0 98 Festo Didactic 86011-00

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Conclusion Table 2-66. Four-pass shell-and-tube heat exchanger calculations Parallel-flow US customary units. Average flow (Btu/h ft 2 F) 1.0 1.0 2.0 2.0 3.0 3.0 5.0 5.0 6.0 6.0 7.0 7.0 8.0 8.0 9.0 9.0 22. Compare the graph obtained at step 21 for parallel-flow configuration with the one obtained at step 13 in counter-flow configuration. For which configuration is the heat exchanger more efficient? 23. Optional: Plot a graph of the average pressure drops as a function of the flow rate for both the counter-flow and parallel-flow modes. 24. Stop the system completely and turn off the power to the electrical panel and to the heating/cooling unit. Store the equipment appropriately. CONCLUSION This exercise allowed to study how a four-pass shell-and-tube heat exchanger is built and to learn on which principles it operates. You also learned to use such an exchanger in the course of characterization procedures designed to expose its behavior in response to different parameter changes. REVIEW QUESTIONS 1. Why is a four-pass shell-and-tube heat exchanger sometimes used instead of a single-pass one? Festo Didactic 86011-00 99

Ex. 2-4 Shell-and-Tube Exchanger (Four Passes) - Optional Review Questions 2. What happens to the overall heat transfer coefficient as the number of tube passes increases? Why? 3. You have the choice between a two-pass and a four-pass shell-and-tube heat exchanger to cool as much as possible a hot process fluid with cold water from a nearby source. Both exchangers have the same total exchange surface. Which one allows you to cool the hot process fluid to the lowest temperature, assuming fixed fluid flows and that the temperature equilibrium between the two fluids is not reached? 4. How would an additional shell pass in an exchanger change the total heat exchange, assuming thermal equilibrium is not attained? 5. Optional: What is the maximum pressure drop recorded across the four-pass shell-and-tube heat exchanger at a flow rate of 28 L/min (7 gal/min)? Compare with the results obtained for the different exchangers in the other exercises if such results are available. Which exchanger causes the smallest pressure drops? 100 Festo Didactic 86011-00