The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Similar documents
Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Building Multi Air Conditioner with Higher Efficiency and Fault Detection Function

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

High Efficiency R-134a Compressor for Domestic Refrigerator

Purdue e-pubs. Purdue University

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Low GWP Refrigerants for Air Conditioning Applications

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

System Using Exhaust Heat from Residential GHPs

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Performance of CO2 Cycles with a Two-Stage Compressor

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Efficiency of Non-Azeotropic Refrigerant Cycle

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

System Modeling of Gas Engine Driven Heat Pump

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Compressor Capacity Control: A New Direction

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Sub-Critical Operation of the CO2 Expander/ Compressor

The Development of the Energy-Saving Technology by the Composition Control of R407C

Comparison of the High Side vs

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Performance Testing of Unitary Split-System Heat Pump with an Energy Recovery Expansion Device

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

A study of Transient Performance of A Cascade Heat Pump System

High-efficiency Turbo Chiller (NART Series)

Two-Step Capacity Modulation of a Single Cylinder Compressor

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Compressor Capacity Control

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Chapter-8 Capacity Control of Refrigeration Systems

Experimental Study on the Performance of Twisted Capillary Tube

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Geothermal ORC Systems Using Large Screw Expanders

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Design of Compressors to Meet the Performance Ranges Required for Residential Air Conditioning

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Low Global Warming Refrigerants For Commercial Refrigeration Systems

High-Performance, High-Reliability Gas Heat Pump

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

A Study on Compression Characteristic of Wet Vapor Refrigerant

R32 Compressor for Air conditioning and Refrigeration applications in China

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

Study of R161 Refrigerant for Residential Airconditioning

Drink Showcase Equipped with Inverter Freezer

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities Y. J. Hwang LG Electronics Ltd. G. S. Choe LG Electronics Ltd. C. M. Kim LG Electronics Ltd. B. Y. Chung LG Electronics Ltd. Follow this and additional works at: http://docs.lib.purdue.edu/iracc Hwang, Y. J.; Choe, G. S.; Kim, C. M.; and Chung, B. Y., "The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities" (2002). International Refrigeration and Air Conditioning Conference. Paper 543. http://docs.lib.purdue.edu/iracc/543 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R4-3 THE DEVELOPMENT OF HIGH EFFICIENCY AIR CONDITIONER WITH TWO COMPRESSORS OF DIFFERENT CAPACITIES *Yoon-jei Hwang, PhD, Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics. 327-23, Gasan-dong, Keumchin-Gu, Seoul, 152-023, Korea; Tel: +82-2-818-7830, Fax: +82-2-856-0313, E-Mail: hyj@lge.com Gyu-sang Choe, PhD, Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics. 327-23, Gasan-dong, Keumchin-Gu, Seoul, 152-023, Korea; Tel: +82-2-818-7933, Fax: +82-2-856-0313, E-Mail: gsc@lge.com Cheol-min Kim, Senior Research Engineer, Digital Appliance Research Laboratory of LG Electronics. 327-23, Gasan-dong, Keumchin-Gu, Seoul, 152-023, Korea; Tel: +82-2-818-7825, Fax: +82-2-856-0313, E-Mail: kcm@lge.com Baik-young Chung, PhD, Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics. 327-23, Gasan-dong, Keumchin-Gu, Seoul, 152-023, Korea; Tel: +82-2-818-7940, Fax: +82-2-856-0313, E-Mail: bychung@lge.com ABSTRACT An air-conditioner driven by two compressors with different capacity was developed to improve energy efficiency by use high efficiency components and load matching. An algorithm for driving the two-compressor system was devised for optimum capacity modulation, and seasonal energy efficiency increased by 22%, when compared with that of a conventional air-conditioner of the same rated cooling capacity. If this achievement converted to electric power consumption, we confirmed that the monthly electric power consumption decreases 35% with the new system. INTRODUCTION The energy efficiency regulation of air-conditioner becomes tightened every year, because of the worldwide environmental protection movement. However, it became more difficult than ever, to reduce energy consumption without retail price increase. It is known that a variable speed compressor system shows higher efficiency, but the higher cost has not attracted consumers as many as the manufacturers expected. Therefore a new method was developed to improve the efficiency without adopting the expensive variable speed compressor. There are two ways in indicating the energy efficiency, COP (Coefficient of Performance) and SEER (Seasonal Energy Efficiency Ratio). So far, the investigation for high efficiency was focused on the first method, but, in the view of saving the running cost during the cooling season, the second method which is represented by SEER can be more useful. The reason why the capacity modulation method is powerful to increase the energy efficiency of air-conditioning system is as follows. When measuring COP, the test unit operates at one rated test condition, but SEER considered entire cooling load conditions include the rated and minimum condition. In COP measuring system, there is an underlying assumption that the system with higher efficiency at one test condition would show higher efficiency at other operating conditions. But, this measurement omits the fact that the frequent cyclic start-and-stop operation of a compressor could lead to a sharp decrease in energy efficiency, which occurs at a minimum or low cooling loads. When the compressor stops, the high pressure refrigerant migrates into the low pressure side to level out the pressure difference. (1) When the compressor starts, it takes time to recover the high pressure, and it is one of the main reason for the energy loss in the constant capacity air-conditioner. When the cooling load is low, the variable capacity system slows down, and reduces the number of cyclic start and stop operation of the compressor, which saves lots of energy consumption. Figure 1 lists several ways of capacity modulation. In this study, two-compressor system was selected based of

a previous research results in Kim et al (2). A capacity modulation system driven by two compressors was studied and its operating characteristics and energy saving effects were discussed. EFFICIENCY IMPROVING TECHNIQUE Synopsis To increase the efficiency of air-conditioning system, it is necessary to improve the performance of compressor itself and design the heat exchanger efficiently to reduce the pressure gap between the condenser and evaporator. And another important thing is to develop the high efficiency components of system for reducing the power consumption. For example, we need to use high efficient circuit parts, which operate the compressor and the fan, and the chassis with less resistance and the fan with large air-flow. Also it is necessary to change the operation mode to minimum for preventing waste of electricity in case of light cooling load. Actually it means that, in the minimum operation mode, each components of the system also become high efficiency as they were at the rated operation mode. In this study, we tried to increase the efficiency by means of decreasing the power consumption. Using this concept, we can make the high-efficiency system not only in the minimum load but also in the rated load. With this system we saved a lot of electric power in summer season. The representative application technique is as follows; new cycle technique using a common accumulator, low vibration and resonance prevention design of pipe system, the optimum design of evaporator and condenser, the high efficiency motor (SRM: Synchronize Reluctance Motor) for indoor unit fan, a newly-developed outdoor axial fan, the optimized algorithm to control the degree of superheat and the room temperature, the minimization of a waiting electric power with SMPS (Switching Modulation Power Supply). With these techniques, we can save the power consumption by 35% compared with the existing model,. The typical specification and results are shown in Table 1. New Cycle With A Common Accumulator The schematic of system with a common accumulator and check valves is shown in Figure 2. Normally, in two compressors system, it is easy to occur the mal-distribution of the oil, and the reason is as follows. When the evaporated refrigerant flows into two compressors, the flow type of refrigerant is the annular flow. At this time, the vapor refrigerant and some oil which flow through the center of pipe can be distributed according to the capacity of compressors, but some of oil which flows on the wall of pipe is different in distribution effected by the shape and the mounted angle of the distributor and operation condition of compressor, so there will be the mal-distribution of oil in two compressor system. To overcome this effect, the common accumulator is newly developed as shown in Figure 3. Capacity Modulation Control of RPM - Variable Speed - Constant Displacement Control of Stroke Distance - Constant Speed - Variable Displacement Inverter Pole Change 2 Compressor Multiple Cylinder Reverse Rotating Motor Hot Gas By-pass By-pass Suction Delay Figure 1: Classification of capacity modulation.

A refrigerant, evaporated in evaporator, flows into a common accumulator, and there the vapor refrigerant flows into each compressor through a suction line while the liquid refrigerant and oil are accumulated at the bottom of the accumulator. At this time, oil is recovered to the compressor through the oil-return hole with vapor refrigerant. And in this system, check valves at the outlet of two compressors play important roles. During the minimum operation mode, it makes the stopped compressor as a receiver tank preventing the increase of the refrigerant charging amount. Its another role is to prevent the backflow of the refrigerant. Without check valve, partial refrigerant, compressed in driving compressor, flows into the stopped compressor and flows backward through suction pipe. It causes the decrease of mass flow rate, so the condensing pressure is increasing and the evaporating pressure is decreasing, finally the efficiency goes to bad. Of course, the check valves installed at the outlet of compressors would cause the a bad performance owing to pressure drop of vapor refrigerant, for that reason, the optimum design is necessary to minimize the pressure drop in system. We can improve SEER by 3% with this check valves configuration to prevent the non-uniform recovery of oil and the backflow of refrigerant into the stopped compressor. Low Vibration And Resonance Prevention Design of Tubing System In this system, there are two rotary compressors that vibrate largely compared with scroll compressor, so it is important to prepare the injury of pipe system caused by the resonance. First, we choose several pipe system through the analysis of the natural frequency with FEM (Finite Element Method), the modal testing and examination of geometry. And then by the field tests for various condition such as a standard condition, overload condition, variable load and RPM of compressor, we modified the shape and the position of pipe system, decided the magnitude of additional mass for vibration deduction. As a result, we can obtain small acceleration value, 1.3g which is enough to satisfy the regulation limit of our company, below 2g. The final shape of pipe system is shown in Figure 4 and the testing results are shown in Figure 5. Previous Present Compressor 1 Comp. 2 Comp. Cooling capacity 7,200/3,850 7,200 (W) (Rated/Minimum) SEER 3.20 3.91 Power consumption (kwh/month) 491 320 Running Cost (USD/month) 89.6 37.1 Size of Outdoor unit (W H D) 870 655 320 870 655 320 Table.1 The comparison of developed system

Condenser Common accum ulator Evaporator Gas refrigerant Liquid refrigerant & Oil 12 3 Check valve Oil Return hole LEV Com p.1 Com p.2 Figure 2 : Schematics of developed cycle. Figure 3 : A common accumulator. Acc. [g] Vibration data ofcom pressor1 tube 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 52 53 54 55 56 57 58 Frequency ofcom pressor1(h z) Acc. [g] Vibration data ofcom pressor2 tube 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 52 53 54 55 56 57 58 Frequency ofcom pressor2(h z) Figure 4 : Design of pipe system. Figure 5 : Acceleration values of the connecting tube. Figure 6 : Components of indoor unit fan motor.

Optimum Design of Evaporator As an expansion device, we use EEV(Electronic Expansion Valve) instead of capillary tube. It can be more precision mass flow rate control of the system for wide range, but it is located in the outdoor unit. Therefore, it is necessary to optimize the refrigerant path in evaporator. We carried out both the computer analysis and experiments for the constant temperature distribution in each pass of evaporator. As a results, the cooling performance improved by 4% compared to the conventional one-compressor model. High Efficiency SRM The SRM (Switched Reluctance Motor) for indoor unit fan operates the rotator using the torque made by switching of phase. As a result, we can improve SEER by 3.4%. The real features of the original and the developed motor are shown in Figure 6. Axial Fan of Outdoor Unit The axial fan of outdoor unit spends a large part of the total electric power as 6~7%. The important design parameters of axial fan are pitch angle, the area of blade, sweep angle, and so on. In order to reduce the torque and the noise, we decrease the pitch angle, the area of blade and increase the sweep angle in equal rpm. So, we raised the rpm as much as the reduction of noise and moved the driving point of the motor. As a result, we saved 30W in condition of the same noise and air-flow rate as those of the original fan. The original and the developed axial fan are shown in Figure 7. Algorithm Optimization To Control The Degree of Superheat It is important in cycle design to satisfy not only the efficiency but also the stability. Independent of the capacity variation and the combination of indoor/outdoor and desired temperature, the system operates stably when the degree of superheat which is the difference of temperature between the compressor inlet and the evaporator would maintains specific value. As stated above, we use electric expansion valve for expansion device that can control mass flow rate precisely, so we can improve the stability of system. Moreover, we applied a proper control function, which is suitable to variable cycle characteristics and we can follow the changeable temperature condition like real situation. Figure 8 shows the experimental results for several control function to reach the target degree of superheat. In this figure, the third non-linear function represents excellent result. Specially, we choose another control algorithm for the first 90 seconds after operation to protect the compressor, Because a suction pressure can be decreased largely at the time of starting, so there could occur the liquid compression. Indoor Air Temperature Control Algorithm From the experimental results for preventing over-cooled condition, we developed the indoor air temperature control algorithm working without the hunting of temperature in case of repetitive on/off operation. We could reduce the operation cost by the maximum use of variable capacity modulation. We apply the peculiar standard for judgment of the operating compressor by the indoor load and the average value of the accumulated operating time of compressor after starting. Figure 9 shows the result of the developed control algorithm. As the result of this, both power saving and comport are realized. SMPS The efficiency of power supply unit was improved by way of changing the linear transformer, which supplies the alternating voltage to the micro processor, into SMPS(Switching Modulation Power Supply) and then we can minimize the power consumption to 0.4W level.

Figure 7 : Axial fan. 20 15 Degree ofsuperheat( ) 10 5 0-5 -10-15 -20 Starting contro l Real-tim e contro l Targetvalue Proportion PID Non-linear1 Non-linear2 Non-linear3 0 100 200 300 400 500 600 700 800 900 Tim e(sec) Figure 8 : Variation of control characteristics according to superheat control function. Indoor Temperature [ ] 26 25 24 23 22 21 20 100% OFF 100% OFF 100% OFF 100% Old New 100% Mode 40% Mode 0:00 0:05 0:10 0:15 0:20 0:25 0:30 0:35 Time [min] Fig.9 Comparison of indoor air temperature control algorithm.

RESULTS AND DISCUSSION SEER SEER (Seasonal Energy Efficiency Ratio) is used as a standard to define the annual power consumption of system. CSPF (Cooling Seasonal Performance Factor) is defined as follows for the capacity modulation system. [KS 9306(1999)] CSPF = Q c Pc Q c = Total Cooling Capacity during Cooling Time P c = Total Electric Power during Cooling Time In this study, when the outdoor temperature is above 34 º C, the system operates continuously, because the rated cooling capacity is smaller than the building load. In case of outdoor temperature is below 33 º C and the building load is between the rated cooling capacity and the minimum cooling capacity, the system operates in regular and minimum operation mode alternately. But, the building load is below the minimum cooling capacity, the system operates in minimum operation mode. The reason that the CSPF or SEER of capacity modulation system is higher than that of the previous one-compressor system is as follows. The power consumption is reduced when the number of repetitive on/off is decreased. Moreover, during the minimum operation mode, COP (Coefficient Of Performance, The relationship between the cooling capacity and power consumption) is improved as compared to the previous one-compressor system, because the decrement ratio of power consumption is more than that of cooling capacity. In the minimum operation mode, the capacity of condenser and evaporator is increased more than that of compressor as compared to regular operation mode. So, the difference between the condensing pressure and the evaporation pressure decreases, and as the results, the power consumption of the compressor decreases. Descriptions SEER LP255CA 3.20 Two Comp. Drop in 2.877 Evaporator New Design 3.558 Dual Accumulator Two Valve Cycle 3.657 Outdoor Unit Air Flow Optimization 3.674 Indoor Unit Air Flow Optimization 3.692 Outdoor Unit Fan & Shroud Design 3.753 Indoor Unit Fan Optimization 3.775 SRM 3.913 Table.2 SEER enhance technology

Analysis of Contribution to SEER Improvement Through this study, SEER of the previous one-compressor model is increased up to 3.91 (roughly 22% rise) and the electric power is saved by 35%. For the each technique mentioned before, the degree of contribution for total SEER improvement is calculated with simple SEER processing program and shown in Table 2. CONCLUSIONS & FURTHER STUDIES A new air-conditioner with two compressors, brand name WHISEN, was developed to reduce electric power consumption. (1) The monthly electricity consumption decreases 35% from 491 kwh to 320 kwh with the new system using the capacity modulation algorithm. (2) An oil recovery system was devised in which the two compressors share an accumulator in the air-conditioner, whereas a conventional system adopts an oil separator or an oil pressure equalizing pipe. (3) The improvement of SEER saves the running cost greatly in case the country like Korea have a progressive cost scale system for electricity. We are planning to modify the two-compressor system and try to develop an advanced method for variable capacity modulation. REFERENCES 1. Tetsuo Sano, Capacity Control in Residential Air conditioners, Refrigeration (Japanese), Vol. 74, No. 863, pp. 2 9-354, 1999. 2. C. M. Kim et al, The experimental study on the comparison in performance of the system which used modulated compressors, Proceedings of the SAREK 2001 summer annual conference(iii), pp. 1114-1120, 2001. 3. Korea standard association, Air conditioner KS C 9306, pp. 75-90, 1999. 4. S. A. Tassou, C. J. Marquand and D. R. Wilson, Comparison of the Performance of Capacity Controlled and Con ventional On/Off Controlled Heat Pumps, Applied Energy, Vol. 14, pp. 241-256, 1983.