Watermist nozzle issues and test methods

Similar documents
Standards and third party certification

Personal Protection Systems (PPS)

New Approaches to Design for Fire Safety - Residential sprinklers, open plan flat layouts and water mist

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

TECHNICAL DATA OBSOLETE

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

quick response horizontal sidewall sprinkler vk360 (K8.0)

Loss Prevention Standard

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

STANDARD/quick. Sprinkler 42o. August 8, 2011

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

Standard Spray concealed horizontal sidewall sprinkler VK481

standard response Fusible Link Upright sprinkler VK204 (K8.0)

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

BS 5839: Part THE CHANGES

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Microfast quick response Fusible element hsw sprinkler

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

December 14, 2015 Page 1 of 7 TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

microfast and microfasthp quick conventional sprinklers

Fire Performance of external thermal insulation for walls of multistorey buildings

Loss Prevention Standard

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

esfr pendent sprinkler vk510 (k25.2)

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

standard response elo upright sprinkler

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

esfr pendent sprinkler vk510 (k25.2)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Worldwide Contacts.

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. Page 1 of 5

Non-Storage / Special Protection / Storage Sprinklers

quick response Sprinkler 105a October 25, 2010

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

The Worldwide Use of Fire Sprinklers

Sprinkler Identification Numbers

TECHNICAL DATA. Wet 26a. February 22, 2009

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

standard response elo upright and pendent sprinklers (storage-density/area)

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Water Spray Systems: NFPA 15

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

standard response fusible link sidewall sprinkler VK112 (K5.6)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Loss Prevention Standard

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Sprinkler Identification Numbers

TECHNICAL DATA OBSOLETE

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

Transcription:

Watermist nozzle issues and test methods Louise Jackman Fire Protection Systems: Fit for purpose and reliable in service? BRE Global and the National Fire Chiefs Council (NFCC) seminar 24 April 2018 Part of the BRE Trust

What s special about watermist nozzles? Watermist nozzle

Bespoke designs Engineering precision Material selection (e.g. stainless steel, Teflon) Dynamic forces (e.g. valve function) Integral detection (e.g. bulb) Flow paths (K-factor) Availability (e.g. strainers) Manufacturing Assembly

Elements of a watermist nozzle Automatic nozzle Body, fittings and openings Valve Detector Water-filled Under-pressure Openings exposed to atmosphere detector

Timeline of a watermist nozzle Pressure at a remote nozzle P Operating pressure range Standby pressure t dete ctor

Watermist nozzle challenge ambient (no fire) detector Exposure (years): Pressure changes Temperature cycling Movement Mass concentration changes Environmental pollutants (paint, cleaning products ) On-going status: Detection 100% available No accidental detection Pressure maintained No Leaks Potential problems: Corrosion (cracks, pits, deposits) Valve seat (leak, lock) Elastomer migration, adhesion Detector (cracks, deposits)

Watermist nozzle challenge - fire Functions: Immediate action Detection Actuate, open valve Water flow through openings Need: Sensitive detector Sufficient force to open valve, i.e. no stuck valves No obstruction to small orifices, i.e. pressure/flow regime for spray achieved

Watermist nozzle pressure Pressure at a remote nozzle P Operating pressure range Standby pressure dete ctor

Sprinkler heads: qualitative analysis - causes of failures SERGE ZHUIYKOV, Ph.D.* and VINCE DOWLING *Materials Scientist CSIRO, Manufacturing and Infrastructure Technology, Industrial & Research Services, Australia FIRE SAFETY SCIENCE PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM, 2005 3% O-ring adhesion of the sprinkler head; 4% Undetected rupture of bulb wall; 4% Systems dosed with sodium silicate in order to overcome small leaks; 7 % Heavy deposits of hardened sediment; 8% Heavy build-up of dirt and debris on the frame, heat sensitive element and deflector; 15% Intergranular corrosion of the leadtin-bismuth eutectic solder ; 29% Unlisted sprinkler heads; 30% Extensive deposit of paint on the deflector and the glass bulb or fusible link.

How are watermist nozzles tested? Watermist nozzle

Component tests Assessment of performance against standardised methodologies Testing to address: robustness, continuous availability. Ensure a consistent approach with a standard baseline 100 + samples, minimum 6 months testing, BREG test report Watermist nozzle test based on sprinkler component tests from EN 12259-1

Nozzle tests body and valve No accidental detection No Leaks Pressure maintained Tests: Thermal shock Strength of body Service load Leakage Water Hammer Vibration Impact resistance t Corrosion (with parts exposed) Stress (brass/ss) Sulphur dioxide Salt mist Moist air Long term aging

Long term aging (heat exposure) Sprinkler baseline criteria Standby/service pressure 121 degc minimum 90 days Post aging tests Function (at Pmin) Leak (at Pmax) Operating temperature

Nozzle tests - detection Detection within limits No accidental detection Tests: Operating temperature Thermal response detector Thermal shock Strength of body Service load

Service load Nozzle assembly criteria Applied service load Torque precision Tests Determine frame load Bulb strength

Nozzle tests - actuate and deliver Detector responds No stuck valves No obstructions Tests: Function test (at standby pressure) Long term aging K-factor

K-factor Nozzle manufacturing criteria Opening Internal chambers Tests Operating Pressure range Measured flow Determined k-factor

In conclusion BS 8489:2016 and BS 8458:2015 6.11 Components, 6.11.1 General Components should be in accordance with BRE publication LPS 1283 [N1], FM 5560, or other appropriate standard that can be shown to give equivalent performance (e.g. a listed component in the LPCB Red Book Live [15]). NOTE Tests for nozzles, check valves, pressure switches and strainers are under development in CEN. They are at committee draft stage at the time of publication of this British Standard. LPS 1283:2014 The LPCB approval of watermist systems requires both individual components and complete system fire performance to be assessed. The scope for the field of application of an LPCB watermist system approval is defined within the relevant LPS standard: LPS 1283: Issue 1.1 - Requirements and test methods for the approval of watermist systems for use in commercial low hazard occupancies. LPS 1285: Issue 1.1 - Requirements and test methods for the approval of watermist systems for use in domestic and residential occupancies. BS xxxx (2018) watermist nozzle component test specification www.redbooklive.com

Thank you Louise Jackman BRE Global Bucknalls Lane Watford WD25 9XX GB +44 (0)1923 664948 Louise.Jackman@bre.co.uk www.redbooklive.com Watermist components - nozzles Watermist systems LPS 1283 and LPS 1285 Third party approvals - increase confidence in product and system performance