Dual Axis Inclinometer - Active

Similar documents
Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Homeowner s Guide / 1

Digital Marine Exhaust Temperature Alarm

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Using the QRAE Plus personal multigas monitor

Analog Room Pressure Monitor RPC Series

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Sensor Control Panel

918TS Manual 1/26/09-1 -

2100 Series Mechanical Ball-in-Tube Inclinometers

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Terex Operation Manual

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Introduction. OM-THA2

RAE Systems Systems. User Presentation. October Protection Through Detection

Synergy 405PLUS User Guide Manual

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

Follett Performance Plus

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

USER MANUAL Digital CO Monitor Model CO30

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

IMR IX176 Portable Gas Detector User Manual

X64 Wireless Training

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

IDS816 User Manual H Issued January 2009

Contents. Glossary

Proximity Detection Systems. Reliable, proven solutions for mining safety

DEFA HOME. User Manual Base Unit PRO

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Water Tank Level Monitor

ANEMOMETER 4403-RF-BAT

C2 Compact Range Installation & Programming Manual

WIRING DIAGRAM AND INSTRUCTIONS

Watchguard WGAP864 User Manual

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

KFP-CF Series Operation Manual

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Carbon Monoxide Transmitter

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

aura-t TP536/GBR ventilation systems

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

USER MANUAL MINITRACER PORTABLE SNIFFER

Installation Settings Guide

Lyric T6 & T6R Smart Thermostat

user manual Document No , Revision 03 November 2015

COLOUR WEATHER STATION MODEL: AWS888N USER S MANUAL

Wet Bulb Thermo-Hygrometer Datalogger

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Pioneer-R16 Gas Monitor Operator s Manual

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Ax60+ Multi-Gas. Service Manual

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

FLOW CONTROLLER TYPE S/601

High Resolution Display WIRELESS COLOR WEATHER STATION

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

CAREL IR33+ CONTROLLER

CT224 Setup Tutorial

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

SCAN20 Series Gas Detection Controller

EVac II Programmable Digital Vacuum Gauge

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

ZSC100 Gas Detection and Alarm System Controller

BURGLAR ALARM PANEL BS-468/A

Fire Command Keypad. XR5 User s Guide

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Colour Observation System

BURGLAR ALARM PANEL BS-468

Quick start guide. English

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

User Guide ems25plus. Page 1. Normal operation. Product interface

GRAVINER Mk 6 OIL MIST DETECTOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SMART THERMOSTAT WITH HOT WATER CONTROL

Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

IPCM INTELLIGENT PRESSURE CONTROL MODULE INSTALLATION AND OPERATIONS MANUAL FOR CONSTANT PRESSURE CONTROL APPLICATIONS VERSION 1.0

THX-DL Data Logger USER & INSTALLATION MANUAL V

Dixell Installing and Operating Instructions release 7.0

D3D Wi-Fi GSM Smart Alarm System -User Manual

aura-t TP536/EU ventilation systems

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

TV2 Room Pressure Monitor Quick Start Guide

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Transcription:

A full colour dual-axis inclinometer giving operators of machinery an accurate pitch and roll read out. Ideally suited for mining and civil engineering equipment. Powerful Performance The Active Inclinometer measures pitch and roll using a remote incline sensor. The use of a remote sensor allows the display to be positioned at an optional angle for operator visibility whilst allowing for accurate angle measurement. Warning and alarm levels are user configurable through the password protected menu. When a warning level is exceeded, the critical reading will be highlighted yellow and an optional internal audible alarm will begin to beep. When an alarm level is exceeded, the critical reading will be highlighted red and the alarm will sound continuously. Two positive drive outputs are provided that can be set to activate or deactivate on warning and alarm. Installation is simple with the only external wiring required being power and ground. The external sensor plugs into the loom provided. The sensor wiring can be extended if required. The inclinometer display is supplied with a RAM mounting system which allows the display to be orientated optimally for the operator. Optional windscreen mounting kits are available on request. The sensor should be ideally be mounted horizontally with the mounting tabs down and the wires exiting to the rear of the vehicle. For best results, mount the sensor as close to the centre of the vehicle as possible Features The sensor can be calibrated to remove errors due to small offsets in mounting and can be damped to optimise accuracy in high vibration environments. An optional RF sensor is available on request. The unit is multi voltage and can work in 12V and 24V vehicles. Pitch and Roll measurement Configurable warning and alarm levels Outputs for warning alarm Full colour display Remote incline sensor Sensor damping configurable Optional RF sensor Internal buzzer Password protected menu Rugged RAM mounting system, Multi Voltage

Red: Power Black: Ground Green: RS485A Yellow: RS485B White: Warning Blue: Alarm Max 25m 1A fuse Typical wiring diagram Technical Specifications and Ordering Information Part Number (including remote sensor) Part Number (including RF sensor) Part Number (spare remote sensor) Part Number (spare RF sensor) Mounting system Input Voltage 9-36V Power consumption Dimensions (Display unit) Dimensions (Sensor) Sensor cable length Sensor resolution HMDS2000 HMDS2000RF HMTS2M0000B HMTS2M0000BRF 1 RAM mount with diamond base Less than 2W 130mm (width) x 94mm (height) x 25mm (depth) 82mm (length) x 58mm (width) x 36mm (height) 7m 1 degree Operating temperature -40 to 85 degrees

Sensor dimensions

Navigating the Menus Press the Menu key (far left) to open the menu. Using the Keypad The Menu key cancels or goes back one level. The Up key navigates up, or increases a value. The Down key navigates down, or decreases a value. The Enter key (far right) selects an option or confirms a setting. Mode Display Settings There are three display modes Pitch and Roll, Pitch Only and Roll Only, selecting which tilt measurements appear on the Inclinometer. Brightness Controls the brightness of the display, from 1 (dimmest) to 10 (brightest) Alert Settings The Alert Settings menu allows the configuration of the angles at which the Inclinometer enters a warning or alarm state. The angles are given in the unit selected (degrees of percent-gradient) in the System Settings menu. Forward Warning warning state when pitching forwards. Forward Alarm n alarm state when pitching forwards. Backward Warning warning state when pitching backwards. Backward Alarm n alarm state when pitch backwards. Left Warning warning state when rolling left. Left Alarm n alarm state when rolling left. Right Warning warning state when rolling right. Right Alarm n alarm state when rolling right.

Calibrate Sensor Settings Opens the calibration submenu. Reset Calibration Removes the calibration set with the Calibrate option. Response Speed Sets the speed at which the measured angle changes, 1 is the slowest and 10 is the fastest. A slower response speed makes the Inclinometer less prone to sudden changes. Sensor The Inclinometer can use both wired (HMTS2M0000B or HMTS2M3000B) or wireless (HMTS2M0000BRF or HMTS2M3000BRF). This option must be set to match the type of sensor being used. Sensor Address The address of the sensor being used. It is recommended that users use the Scan function, below, rather than changing the address. Scan Scans for either wired or wireless sensors, depending on what is selected with the Sensor option, above. Load Default Settings System Settings Resets all settings to the factory defaults. Angle In Selects whether angles should be shown in degrees or percent-gradient. Warning Output Warning Output Level Selects whether the Warning Output is normally off and switches to power when activated (active-high), or is normally powered and switches off when activated (active-low). Alarm Output Selects whether the Alarm Output is enabled for both Pitch and Roll alarms, just pitch, just roll, or is disabled. Alarm Output Level Selects whether the Alarm Output is normally off and switches to power when activated (active-high), or is normally powered and switches off when activated (active-low). Latch Outputs Allows the warning and alarms states to automatically be held on for a period of time. This is useful to prevent the buzzer and the outputs from switching off and on repeatedly when near an alert level. Mute Time Sets the time that the enter key will mute the buzzer and disable the outputs. Buzzer Enables or disables the internal buzzer. Password Enables or disables the password. Set Password Sets the password required to enter the menu. Calibration Submenu Shows the current calibration. Pressing enter will set the current position of the sensor to zero pitch and roll. The menu key returns the user to the Sensor Settings menu. Selects whether the Warning Output is enabled for both Pitch and Roll warnings, just pitch, just roll, or is disabled.