Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1

Similar documents
HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

EduCam360-B. Fisheye Panorama Network Camera Manual

HDAVS ICR IR Water proof Dome Camera User s Manual

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

4 MP HDCVI PTZ In-ceiling Camera

Multi-sensor Panoramic IR Bullet Camera

HDCVI PTZ Network Camera

Dahua 2-inch Network Speed Dome Installation Manual Version Dahua Technology CO., LTD

3-inch 2 Megapixel Intelligent Network Speed Dome Installation Manual. Version 1.0.0

2-inch Network Speed Dome Installation Manual

HDCVI PIR Camera User s Manual

Network Speed Dome Installation Manual

2 MP PTZ In-ceiling Network Camera

IR Intelligent Positioning System Installation Manual

2-inch HDCVI Speed Dome Installation Manual

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

2 MP Network PTZ Camera

Dahua K Series Cube Network Camera Quick Start Guide

360 Multi-sensor Panoramic Plus PTZ Dome Network Camera

IR Intelligent Speed Dome Installation Manual

High Speed Positioning System Installation Manual

Intelligent Speed Dome Installation Manual. Version 1.0.0

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

IR Intelligent Speed Dome Installation Manual

AHD SPEED DOME CAMERA

6-inch Intelligent Speed Dome Installation Manual

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

User s Manual for ZKIR3 Series IR Day & Night

IndigoVision Alarm Panel. User Guide

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Network Camera. Quick Guide DC-T1233WHX. Powered by

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

IDoorBell Fon DP68 Quick Installation Guide

Four-Door Access Controller User s Manual

Installation and Operation Manual

Cleaning Instructions for Symbol IP54 Devices

IR Speed Dome. Quick Guide UD.6L0201B1357A01

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Ultrasonic Aroma Diffuser AD-SD1-CE

CEILING FAN OWNER S MANUAL

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Digijock Home Security

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Added password for IP setup page : Password must be in IP format!

The Bose 151 SE Environmental Speakers. Owner s Guide

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Hive Active Heating. Thermostat installation guide

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

EW25 EW30 EW35 USER & INSTALLATION MANUAL. Model. Model. Model

DS-2TD Thermal & Optical Network Bullet Camera

MiNi IP Camera Quick User Manual

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Snifter ATEX22 VERSION. User Manual. Distributor

ACTIVE INFRARED BARRIER

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

XPS-ProDry User s Guide Dryer Base

5 Inch Speed Dome Installation Manual V2.0.0

User s Manual for ZKIR3 Series IR Day & Night

Explosion-proof Dome Quick Start Guide. Explosion-proof Dome. Quick Start Guide UD04569B

Outdoor Housing PIH-510 H/L/G & 510 H/L/G IP INSTRUCTION MANUAL

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1.

Maintenance. Maintenance

CONTENTS BEFORE YOU BEGIN

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

O2LPR67 Full HD Bullet IP LPR Camera

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:


Duct and Rough Service Carbon Monoxide Sensor

CRISTAL Built-in Dish Sterilizer Instruction Manual

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Electric Wall/Ceiling Projection Screen

Bravo II. High Performance Multi-Purpose Speaker

Intelligent Waterproof Network Outdoor Camera. 3-axis rotation design, stylish housing, IP67 water-proof rating

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

USER MANUAL. PEDESTAL FAN (16 Inch)

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Installation and Operation Manual. Wireless Indoor Strobe

Transcription:

Quick Start Guide 4MP Vandal Dome Fixed Lens IP Camera O4D1 Version 1.1.1

Welcome Thank you for purchasing this Network camera! This manual is designed to be a reference tool for your system. Please read this manual carefully before operating the unit and retain it for future reference. Should you require any technical assistance, please contact Speco Technologies Technical Support. i

Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to local electrical safety codes. Use a certified/listed 12VDC Class 2 power supply only. Please note: Do not connect two power supplying sources to the device at the same time; it may result in device damage! The product must be grounded to reduce the risk of electric shock. Improper handling and/or installation could run the risk of fire or electrical shock. 2.Environment Heavy stress, violent vibration or exposure to water is not allowed during transportation, storage and installation. This product should be installed in a cool, dry place away from direct sunlight and heat sources. Do not install the product in extreme temperature conditions. Do not expose the camera to electromagnetic radiation. Otherwise it may result in CMOS sensor failure. Do not block any ventilation openings. Do not allow water and liquid intrusion into the camera. 3. Operation and Daily Maintenance Please shut down the device and then unplug the power cable before you begin any maintenance work. Do not touch the CMOS sensor optic component. You can use a blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, use a cloth dampened with a small quantity of neutral detergent. Finally use the dry cloth to clean the device. Please use a professional optical cleaning method to clean the enclosure. Improper enclosure cleaning (such as using cloth) may result in poor IR functionality and/or IR reflection. The grounding holes of the product are recommended to be grounded to further enhance the reliability of the camera. Dome cover is an optical device, please don t touch or wipe cover surface directly during installation and use, please refer to the following methods if dirt is found: Stained with dirt Use oil-free soft brush or hair dryer to remove it gently. Stained with grease or fingerprint Use oil-free cotton cloth or paper soaked with alcohol or detergent to wipe from the lens center outward. Change the cloth and wipe several times if it is not clean enough. ii

Warning This camera should be installed by qualified personnel only. All the examination and repair work should be done by qualified personnel. Any unauthorized changes or modifications could void the warranty. Statement This guide is for reference only. Product, manuals and specifications may be modified without prior notice. Speco Technologies reserves the right to modify these without notice and without incurring any obligation. Speco Technologies is not liable for any loss caused by improper operation. Note: Before installation, check the package and make sure that all components are included. Contact your rep or Speco customer service department immediately if something is broken or missing in the package. Accessory Name Amount Network Camera Unit 1 Quick Start Guide 1 Installation Accessories Bag 1 CD 1 iii

Table of Contents 1 Physical Specifications... 1 1.1 Components... 1 1.2 Dimensions... 2 1.3 Alarm Setup... 2 2 Device Installation... 5 2.1 Installation Steps... 5 2.2 Micro SD Card Installation... 7 3 IP Scanner... 8 3.1 Overview... 8 3.2 Operation... 8 4 Web Operation... 9 4.1 Login and Main Interface... 9 iv

1 Physical Specifications 1.1 Components Note: The following figure is for reference only, which is used to indicate the components and the functions. Refer to the following figure for component structure. See Figure 1-1. Figure 1-1 Component structure Please refer to the following table for detailed information. Port Port Name Note Port 1 DC power jack Connect to DC 12V power Port 2 Ethernet Port Connect to standard Ethernet cable. Supports POE. Port 3 Audio input port Input audio signal Port 4 Audio output port Output audio signal to speaker Port 5 I/O port Alarm signal input/output 1

See below for detailed information regarding the I/O. Port Name Port Sequence Port name Function Description 1 ALARM_IN1 Sensor input I/O Port 2 ALARM_OUT1 Relay output 3 ALARM_GND Connect ground 1.2 Dimensions Please refer to the following figure for dimension information. The unit is in mm. See Figure1-2. Figure1-2 1.3 Alarm Setup 2

Figure1-3 Alarm input, output description: Step 1 Connect alarm input device to the alarm input of the I/O cable. Step 2 Connect alarm output device to the alarm output of the I/O cable. Alarm output is an open collector circuit which connects 10K resistor to 3.3V externally. Step 3 Open the web viewer and set the alarm input and output correspondingly. When there is an alarm signal, the alarm input device will generate high and low level signals. Set the corresponding type to NO or NC. Step 4 Set the alarm output. The alarm output is for the alarm output port of the device. Please refer to the following figure for alarm input information. See Figure 1-4. Alarm input: When the input signal is idle or grounded, the device can collect the different status of the alarm input port. When the input signal is connected to 3.3V or it is idle, the device collects logic 1. When the input signal is grounded, the device collects logic 0. Figure 1-4 Please refer to the following figure for alarm output information. See Figure 1-5

When alarm output is OC, it needs to increase pull-up resistance externally to work normally; output signal is high and low level. After external pull-up resistance is increased, the default of output signal is high level, and it switches to low level when there is alarm output. The working current of alarm output port is recommended as <= 10mA. The max current which is used to drive the external circuit is 80mA and it is advised to add a relay if it is beyond the value. Figure 1-5 4

2 Device Installation 2.1 Installation Steps Note: Before installation, please make sure the installation surface can support a minimum of 3 times the weight of the camera Figure 2-1 Device installation illustration Step 1 Use inner hex wrench in the accessories bag to open dome enclosure by unfastening three inner hex screws on enclosure. Step 2 Put installation template on the designated surface where you will install the device (wall or ceiling). Step 3 Drill holes according to position of the holes on the installation template and then insert the expansion bolts in the holes. Secure these three bolts firmly. Note: If user pulls out cable from top of installation surface, you must dig an exit hole on installation surface according to the installation template. If user pulls out cable from side of cable channel, it must go through the U-shape channel on dome pedestal, and take out cable from the side exit hole on pedestal. Step 4 5

Adjust the device installation pedestal to the proper position and then pull cable through the exit hole on Installation surface. Make direction of TOP sign same as it is on the installation template. Line up the three screw holes in the device pedestal to the three plastic expansion bolt holes in the installation position. Put the three self-tapping screws in the three plastic expansion bolts firmly. Fix dome body on installation surface. Step 5 Hold both sides of the rotation bracket bottom with hands, rotate horizontally along the axis, and adjust lens horizontal direction to designated position. Hold the LED decoration cover with hand, rotate along the vertical direction, adjust the lens vertical direction to designated position; it is okay to loosen the fix screws on both sides of the bracket first if it is too tight to adjust (just make it loose, do not take it out), then adjust the lens, tighten the fix screws after adjustment. Hold the LED decoration cover with hands, rotate horizontally along the axis, and adjust the lens image to designated position. Range of lens: vertical (0 ~+64 ), horizontal (0 ~+355 ), image rotation direction (0 ~+355 ). Note: When tilted to 64 vertically, please make sure to set the image rotation correctly in order to avoid the outer cover blocking the IR light which would result in IR reflection. Figure 2-2 Note: Long press the Reset button shown in Figure 2-2 for 10 seconds when the device is powered on if the device needs to be restored to the factory default setting. Step 6 Take up the dome enclosure, put it back on the camera properly regarding to screw and hole, and fasten the three inner hex screws with the wrench. 6

2.2 Micro SD Card Installation Note: Please disconnect the device before installing the micro SD card. Step 1 Find the micro SD card slot in figure 2-2; open the slot according to the direction in figure 2-3. Step 2 Adjust the card to the proper direction and install it into the slot. Step 3 According to the direction in figure 2-4, close the micro SD card slot and keep it locked. Figure 2-3 Micro SD Card installation illustration 1 Figure 2-4 Micro SD Card installation illustration 2 7

3 IP Scanner 3.1 Overview IP Scanner can search for the device on the local network. Please note that only devices that are on the same subnet can be discovered. 3.2 Operation Open up IP Scanner. Figure 3-1 In the device list, you can view the IP address, model number, and MAC addresss of each device. Select the applicable device and double click to open up the web viewer. Figure 3-1 IP Scanner

4 Web Operation This device supports viewing and management via a web browser on a PC. 4.1 Login and Main Interface Open the browser and input network camera address in the address bar or double click the device in IP Scanner. See Figure 4-1. Input your IP address here Figure 4-1 IP address The login interface is shown as below. See Figure 4-2. Please input your user name and password. Default user name is admin and password is 1234. Note: For security purposes, please change the password after initial login. Figure 4-2 Web login After logging in, follow directions to install applicable plugins.