CORTEC. CORTEC

Similar documents
Installation Operation Maintenance Instructions

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

Module 7: Air Supply System

3M Aerosols. Electrical Products Division. 3 Innovation

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

automatic FiReFighTing SYSTeMS in PainT booths

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

Exceeding Expectations

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

ELECTRO STATIC PRECIPITATOR [ESP]

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Reducing the Cost and Risk of Dust Collection in Coal

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices

Desiccant Breathers: A Front Line Defense in the War on Contamination

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Advanced heat transfer technology

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

industry revolves around VMMD Series Membrane Air Dryer

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Installation & Maintenance Instructions

R100 Oil-Less Refrigerant Recovery Unit

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

Design Manual Installation Operation Maintenance

Installation, Operation and Maintenance Manual

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

CPVS PRODUCT DESCRIPTION

COMBUSTIBLE DUST SAFETY PROGRAM

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Burner Comparisons. Typical Competitor s Burner

CMMD Series Membrane Air Dryer

Efficiency & Savings through On-Line Chemical Cleaning

P23 MELT CONFINED SPACE LOG

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

USER S INFORMATION MANUAL

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

OPERATION & MAINTENANCE MANUAL RHS680

Temperature Control for

PDF Created with deskpdf PDF Writer - Trial ::

CPF PRODUCT DESCRIPTION

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

USER S INFORMATION MANUAL

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

USER S INFORMATION MANUAL

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

IN THE PULP AND PAPER INDUSTRY

Industrial Ventilation: It s not just Blowing Smoke! Eric Anderson, M.S., P.E.

HIGH QUALITY AUTOMOTIVE AND INDUSTRIAL CLEANING SOLUTIONS

INTRODUCTION TO SOLAR THERMAL POWER STATIONS We shall look at some of the different methods of supplying solar energy to the power stations.

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

CPC PRODUCT DESCRIPTION

GIRTON CABINET WASHER MODEL 794A

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

KOCH Curtain Coaters

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

2x58 MW Coal Fired Power Plant at Mauritius

Introduction to Bulk Solids. The Basics

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

DUST COLLECTION TRAINING. Revision 2013

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

Discover the Difference

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Typical damages to Boilers & Economizers

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Special Occupancy Requirements

ACCELERATE YOUR CURING TIME

AIR SENTRY DESICCANT BREATHERS

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

CRU-S Series Stainless Steel Condensate Recovery Unit

Installation GUIDE 6 SERIES. Built-in Electric Single and Double Wall Ovens MVSOE630 / CMVSOE630 MVDOE630 / CMVDOE630

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Patio Heater_ _V4_ENG.book Page 1 Tuesday, September 2, :00 AM. AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

Transcription:

Case Study 1 How do you cut lay-up costs...25%... 50%... even 75%? A large processing plant in Texas was going to take a system out of service for two years and then bring it back on line. The system contains a variety of heat exchangers, boilers, vessels and expensive valves. A substantial reduction in lay-up costs looked attractive. But there were additional considerations -- severe environment, extended exposure, and primarily carbon steel construction. All the equipment was to be stored outside in weather conditions with very high humidity and severe temperature fluctuations between day and night-for two years. With thousands of feet of tubing and interior surfaces in vessels, tanks and valves, effectively stopping corrosion was a major challenge. How it was done. The interior of all the equipment (tubes, cavities, void spaces) were fogged with CORTEC VCI-309 at a rate of 1/2 ounce per cubic foot. They were fogged using a conventional gun and compressed air. It was fast, safe and efficient. VCI action was a great way to protect hard-to-reach interior and recessed areas. After fogging, the openings to all the voids and cavities of the equipment were capped and sealed. Afterwards, the equipment was left outside, uncovered. VCI protection provided considerable savings. Conventional treatment would have cost 3 to 4 times as much. However, after two years of outside storage would this reduction hold or would reconditioning and reinstallation expenses wipe out the initial savings? The Moment of Truth. Two years go by. The results? No visible corrosion upon inspection of the equipment. Not even any signs of corrosion in areas where humidity had condensed, and settled as water in low spots. Additionally the CORTEC VCI-309 Powder helped speed up returning the equipment to operation. The equipment was put into service without unnecessary cleaning.

Case Study 2 How do you avoid failure of relay contacts in corrosive environments? Considering the reliability of thousands of electronic relay contacts in operation, their individual performance record is noted only when one goes down. It failed not because the contact did not perform to spec. It probably stopped because the contact couldn't withstand the corrosive attack. Severe corrosion attack may occur infrequently, perhaps only once every few years. Unfortunately, no geographic area is immune. There can be brief periods of intense attack from excessive humidity, industrial gases and outside pollutants. Not all relay contacts are in a humid coastline environment. But at some time, many relay contacts could be temporarily exposed to this type of climate. Reliability of a relay contact is too important to leave to the corrosive atmospheric conditions in a plant. These factors illustrate the astute reasoning behind a rather severe test that a major manufacturer of electrical enclosures recently conducted. The test consisted of KUP industrial relays in four electrical enclosures with their covers closed for normal operation. Two enclosures were set as the control sample; the other two contained CORTEC VCI- 110 Emitters. The four enclosures were then subjected to six weeks of continuous condensing humidity at elevated temperatures (110 F +/43 C +). During this time the relays were constantly powered, cycling over one million times. At the completion of the test, the contact resistance for each relay was measured. The two enclosures without CORTEC VCI- 110 Emitters, the contact resistance of the relays increased to over 90,000 OHMS. The relays protected by the CORTEC VCI-II0 Emitters showed normal contact resistance. Can we help you? Just use the reply card, or call 1-800-4-CORTEC CORTEC Vapor Corrosion Inhibitors may have a new answer for you JULY/ 1993

Case Study 6 How do you ship tubulars across the ocean and store outdoors for 2 years without corrosion? Combustion Engineering Inc., a major manufacturer of power plant equipment, boiler pipes, etc. was experiencing internal and external corrosion on tubulars shipped to overseas locations. The pipes are typically capped on the ends and external surfaces are coated with shop applied primer. The internal corrosion is attributed to condensation of moisture experienced during shipment from changes in climate, and due to day/night temperature cycles. The "red" primer applied to the external surfaces has limited protection capability of up to 6 months outdoors, and the corrosion is aggravated in the areas of mechanical damage due to shipping and loss of adhesion. Combustion has been searching for a suitable method of protection that would provide both internal and external protection. The additional requirement for any material applied to the critical tubing and other components, is that it must be free of any contaminants and should be easily removable from weld areas and during start-up of the plant. In many cases the coating is expected to burn-off from boiler-wall surfaces, but should not form polluting and toxic decomposition products. After considerable testing and evaluation of commercially available products, Combustion Engineering has selected two Cortec materials for this application: VCI-368 for external surfaces and VCI-309 for internal surfaces How it was done. The exterior of all headers, upper and lower feeder pipes, machined flange surfaces, valves and associated equipment is sprayed evenly with VCI-368 to the dry coating thickness of 3-4 mils (75-100 microns). VCI- 368 will air dry at ambient conditions in 30-90 minutes to dry, self-healing film. At this point the equipment and pipes are ready for handling and shipment and the VCI-368 coating will provide protection at points of touching and friction between components, or on metal surfaces in direct contact with wooden pallets or crating. Results The results are very positive indicating overall protection after 2 years of outdoor storage. The external surfaces are protected to a large extent, even after shipment across the ocean, and extended storage exposed to high humidity, direct rain, snow and salts. VCI-368 coating does not become brittle or show signs of loss of adhesion, and above all, it is self healing and very effective in protecting metals in corrosive conditions.

Case Study 10 How to protect heavy equipment during field storage. 1.) Coal shuttle cars returned to storage areas as they were taken out of service. Equipment such as this is usually heavily contaminated with coal residue and excess build-up of grease and oil which tends to pick up airborne dust, etc. 2.) Equipment must be elevated to a suitable height to allow easy access to underbody surfaces. 3.) Larger coal aggregate is removed from hoppers and conveyor chains. High pressure water blasting is carried out to remove surface contaminants. 4.) When all surfaces are cleaned, electrical enclosures are protected by placing a CORTEC VCI device of the correct size in the top of each such enclosure. Units are then sealed. CORTEC VCI-329 Oil Preservative Inhibitor is then fogged into all oil reservoirs including hydraulics. Entire exterior surface is then coated with CORTEC VCI-368 Heavy-Duty Inhibitor. Thickness of film will depend on tenure of protection and will vary from 2-5 mils (50 to 125 microns). Areas that are expected to accumulate excess moisture may be treated to a thickness up to double that. 5.) Equipment is left in a ready-to-use condition. Removal of coating is not usually necessary as added corrosion protection will be gained when equipment is returned to service. Driving compartment may be steam cleaned to remove CORTEC VCI-368. If machinery is to be placed back on the ground, any damage to the coating caused by chains used for lifting should be "touched up" prior to storage.

Case Study 13 How to prevent corrosion from damaging vessel internals and flange faces in storage. A leading Oilfield Exploration & Production Company entrusted the job to MB Tecserv. Two Technicians treated 8 vessels in one day using advanced Vapor Corrosion Inhibitor Technology. Cortec VCI-329 Concentrate was misted into each vessel using a pressurized spray unit - Flange covers were replaced & secured. A powerful anti corrosion vapor is released within the vessel which migrates to all recessed areas giving total internal protection.

Case Study 14 How to protect complex pipework and vessels against corrosion damage from manufacture to commissioning. MB Tecserv Technicians preserved internal surfaces using the latest Vapor Corrosion Inhibitor technology. CORTEC VCI-309 Powder was dispersed throughout the system using a dry fogging technique. CORTEC VCI-309 Powder was directed to all sections of the system by systematically opening and closing valves. CORTEC VCI-309 generates a powerful anti corrosion vapor within the system which migrates to all recessed areas and protects against corrosion for up to 2 years even with moisture present.

Case Study 15 How to refurbish expensive tube bundles and prevent subsequent deterioration in storage. BP Exploration entrusted the job to Motherwell Bridge. Each bundle was refurbished by MB Thermal and preserved by MB Tecserv using advanced Vapor Corrosion Inhibitor Technology. Crates were lined with CORTEC VCI-126 PLASTIC FILM for corrosion and moisture protection. CORTEC VCI-307 VCI POWDER was fogged into tube internals and over external surfaces before each crate was sealed. The enclosed atmosphere is conditioned with a powerful anti corrosion vapor which provides total protection for up to 2 years.

Case Study 16 Internal surfaces of pipework are subject to corrosion attack after hydrotesting during shutdown and in storage. MB Tecserv's new application systems provide fast, efficient distribution of CORTEC Vapor Corrosion Inhibitors which give total internal protection for up to 2 years. A range of VCI Powders and Liquids can now be dispersed effectively throughout small and large bore pipework in straight lengths or complex configurations. These portable application systems can be hand carried to any location and a simple connection to an L.P. compressed air source makes them operational in minutes.

Case Study 21 STORAGE SHUTDOWN SHIPMENT MAINTENANCE How to prevent the development of corrosion on pipe internals during shipment to site and avoid expensive clean up costs before commissioning? MB Tecserv developed a protection program in which CORTEC VCI-649 Concentrate is applied by wet fogging immediately after hydrotesting. This procedure provides total internal corrosion protection for up to 2 years and avoids the need to dispose of large volumes of inhibited water. Can we help you? Just use the reply card, or call 1-800-4-CORTEC OCTOBER/1993

Case Study 22 STORAGE SHUTDOWN SHIPMENT MAINTENANCE How to prevent corrosion from damaging a "Texas Tower" tube bundle during an 8 month storage period. MB Tecserv produced a 3 stage program which provided optimum corrosion protection for both internal and external surfaces. 1) Tube internals were treated with CORTEC VCI-307 Powder Inhibitor which was dry fogged with an MB Tecserv blower. 2) External surfaces were treated with CORTEC VCI-369 Open Atmosphere Inhibitor. 3.) The bundle was protected from the elements with custom made weather proof sheets. Can we help you? Just use the reply card, or call 1-800-4-CORTEC

Case Study 23 PROBLEM STORAGE SHUTDOWN SHIPMENT MAINTENANCE How to prevent corrosion from damaging expensive power equipment during a 12 month shutdown in a humid, tropical environment. MB Tecserv developed a program to protect all equipment and systems at Tema Power Station, Ghana. CORTEC Vapor Corrosion Inhibitors were added to all lubricating oil systems, water cooling systems and fuel oil systems and circulated. Electrical systems were protected with CORTEC VCI-170 Impregnated Tapes. Special Wet Fogging techniques were used to enhance protection in fuel oil tanks, pumps, crankcases, turbochargers and exhausts. Can we help you? Just use the reply card, or call 1-8004-CORTEC CORTEC Vapor Corrosion Inhibitors may have a new answer for you.

Case Study 25 STORAGE SHUTDOWN SHIPMENT MAINTENANCE How to protect the internal surfaces of pipe systems, pipe spools and vessels against corrosion without introducing liquid inhibitors. CORTEC VCI-309 Powder was applied using a new dry fogging technique developed by MB Tecserv. The powder was dispersed by an MB Tecserv Blower which ensures fast, efficient distribution throughout the system, providing total internal protection for up to 2 years. All vents were sealed with proprietary caps to retain CORTEC's protective vapor. Can we help you? Just use the reply card, or call 1-800-4-CORTEC OCTOBER/1993

Case Study 26 STORAGE SHUTDOWN SHIPMENT MAINTENANCE How to ensure that critical motor spares are stored corrosion free and ready for immediate use. MB Tecserv solved the problem by wrapping the rotors in CORTEC VCI-137 Impregnated Foam and then sealing the storage containers. The vapor mechanism of CORTEC VCI- 137 ensures that all surfaces of the rotors, even recessed areas, are protected for up to 2 years. This modern approach to corrosion protection is safe, clean and fast, and avoids expensive degreasing and clean up costs before installation. Can we help you? Just use the reply card, or call 1-800-4-CORTEC OCTOBER/1993