Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Similar documents
1850 Series TRIPLE TREAT Operation Manual

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

Clean Water Made Easy

FLECK 5600 WATER SOFTENER INSTALLATION

CWS Plus Sediment Filter Installation & Start Up Guide

Clean Water Made Easy

NovoSoft 465 Series SIM Water Softener Operation Manual

WS1 Greensand Installation & Start Up Guide

WS1 Softener Installation & Start-Up Guide

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

MP-MBA-45T-1/60T-1 / 75T-1

Owner's Manual. WS Series. Water Softener

5900S Softener Installation & Start-Up Guide

7500-S Sediment Backwash Filter Guide

Fleck 2510 SXT Catalox Installation & Start Up Guide

5700-E Sediment Filter Installation & Start-Up Guide

5900-BT Softener Installation & Start-Up Guide

Installation and Operation Manual

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

Fleck 5600 Carbon Filter Installation & Start Up Guide

What to expect from your water softener

7800 Neutralizer Installation & Start-Up Guide

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

RAINFRESH CGFE GREENSAND FILTERS FOR REMOVAL OF IRON, MANGANESE & HYDROGEN SULFIDE. Installation & operation instructions

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

Clean Water Made Easy

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

Installation & Service Manual

7000 Meter Initiated Valve

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

Fleck 7000 Sediment Filter Installation & Start-Up Guide

IMPORTANT SAFETY INFORMATION READ ALL...

2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL

Installation and Operations Manual

Fully Automatic Water Filters

RevV4 Valves & Systems Service Manual. Innovative Solutions for Your Water

Cabinet Non-Electric Water Softener

High Flow 7000 SXT Series Water Softeners

High Flow 7000 SXT Water Softener

165 Series Iron Filter Valve Manual

Owner s Manual / 5600 Econominder

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Clean Water Made Easy

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

GE & PROFILE SmartWater Softener Systems

Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide

C Series Water Softeners Installation & Operation Manual (Please save for future reference)

565 TLC Softener & Tannins Reduction System

Fleck 2510 Softener Installation & Start Up Guide

C Series Water Softener Installation & Operation Manual (Please save for future reference)

The WateRx Plant. Features/Benefits. Applications (for municipal water usage) Great water throughout the home or office. Automatic weekly backwash

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

565 HIM Softener, Iron & Manganese Reduction System

TFM Series Water Softener Installation & Operation Manual (Please save for future reference)

ProFlo SXT Valve Downflow / Upflow

5900e Greensand Filter Installation & Start-Up Guide

High Performance System

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

Installation Instructions & Owner's Manual. IM & INT Series

Econoflo SXT Automatic Meter Initiated Water Softener

5900e Neutralizer Installation & Start Up Guide

Installation Instructions and Owner s Manual. HE, IM & INT Series. Water Softener System

Owners Manual Models: 080-MXX-100, 080-MXX-150, 080-MXX-200, 080-MXX-250. US Water Systems Matrixx Commercial Water Softener

Metermatic Water Softener. Operation Manual

ProMate EcoMax. Owner s Manual

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

6700XTR Valve Downflow

FULLY AUTOMATIC WATER SOFTENER

Owner s Manual HELLENBRAND, INC.

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

Water Softener Installation Guide Effective for all Softeners from our Range

CMP & C METERED SERIES

Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models

Autotrol Performa FA Valve

Installation Instructions & Operating Manual. EM Series. Water Softener System

5900S Arsenic Filter Operation & Maintenance Manual

Evolve Series. Water Softeners and Conditioners. For Models: EV1 EV2 EVR EVRC EVRS EVRCS. For Cabinet Models: EVC EVCS

Fleck 2510 Sediment Filter Installation & Start-Up Guide

OptiSoft Softeners Simple Install Steps 1-17

FUSION PROFESSIONAL-GRADE METERED NITRATE REMOVAL SYSTEM

Water Softener Installation / Operation Manual

Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,

INSTALLATION INSTRUCTIONS

TotalCare, CareSoft Elite CareSoft Pro. and. Series. Water Softeners and Conditioners. For Models: TC1 TC2 CSE CSERC CSP CSPRC

Installation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C

Pro-Ox 5900S Installation & Start-Up Guide

Downloaded from manuals search engine

Water Softening. system. Water Softening System. ge.com. Safety Information...2 Installation Instructions Step-by-step instructions...

Installation Instructions and Owner s Manual. N, NMS, NES, & INT2 Series. Water Softening Systems

Tier1 Water Home Filtration System

INSTALLATION AND OPERATING INSTRUCTIONS

Fully Automatic Water Softeners

Plumbline 1000 Series Timered Softeners Owners Manual Water Softener Models

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

HD / HDL Valves & Systems Service Manual

Model 700MM Water Softener

Transcription:

Water Softener & Single Tank Triple Treat System Installation Overview Using 1850 Metered Valves

System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe. Do not exceed 125 psi water pressure. Do not exceed 110F water temperature. Do not subject unit to freezing conditions. All plumbing must be in compliance with local and state plumbing codes. Determine a suitable location for the system. The chosen location should provide you adequate access to service the unit. Ensure that the location is after the main water supply control valve with access to the water line that feeds the home (prior to hot water heater).

OVERVIEW Plumbing connections o Shut off main o Release water pressure o Make pipe connections Level I valve programming (Initial settings) o Time of day o Date o Number of people o Water hardness Level II programming (settings made at factory) Brine tank set up and initial fill Brine line connection Drain line connection System start-up (in backwash)

! Plumbing Connections Be sure to comply with all required plumbing codes. 1. Shut off main water supply to the home. 2. Release water pressure by opening a faucet at the kitchen sink or other location. Important! - Be sure to lubricate the o-rings on the quick connect fittings prior to installation. 3. Make final main water connections to the valve, using quick connect fittings. Includes: (2) 3/4 male threaded 90 quick connect fitting (2) 1 male threaded straight quick connect fitting a) Install fittings on the by-pass by removing the red locking clips. b) Return the red locking clips to secure the fitting. Fig. 1

1850 Valve (Metered for demand regeneration) Features By-pass valve is included and comes with ¾ and 1 quick connect pipe fittings. Metered for demand regeneration. Ideal for softeners, iron, sulfur, carbon and sediment filters. For tanks to 16 (softeners). For tanks to 10 (filters). Easy to program. Operational data shown on LED, including flow rate, last regeneration date, gallons remaining and more!

Valve Programming FIRST - UNLOCK VALVE Press and hold for 3 seconds to unlock the valve for programing.

Settings 1) Menu Key Press this key to enters or exit menu Valve button programing control definitions 2) Set / Save Regen Key Press this key to select a program or to save a setting 3) Up arrow Key Press these keys to go to the previous menu 4) Down arrow Key Press these keys to go to the next menu

Level-1 Level-I Set up Parameters (Required for initial set-up) Time Enter the time of valve set up. Date - Enter Today s date at time of valve set up. Number of People Enter # of full-time residence (default 4). Water Hardness set it to your test results ( default 20 gpg). Vacation Mode default is no, changing this setting will change the valve operation to a calendar cycle.

Making Adjustments Level I All programing is adjusted using the methods described in the programing method. Setting level I programing Time 1) Press * to enter menu. (hr. display will be highlighted) 2) Press to enter hour setting (must be flashing to edit) 3) Press or to adjust Hr. 4) Press to save and move to minute setting (flashing). 5) Press or to adjust minute. 6) Press to save and move to AM/PM setting (flashing). 7) Press or to adjust AM/PM. 8) Press to save and move to Hr. spot (not flashing). 9) Press to go to current date set up or to cycle through level I settings. (continue to set all level I setting) 10) Press * to exit menu and return to main screen. *Note: if valve is locked you will need to press and hold menu for 3 seconds. Valve will beep when changing menu s or parameters. Highlighted parameter must flash to be able to adjust setting.

Level-II Programming (Settings have been pre-set at the factory) Level-II These settings have been made at the factory, and are held in memory. Level-II settings will not be lost during a power outage. However, if adjustments are desired, follow the directions below. Language Valve operation Regen. Mode Regen. Time Capacity Calc. Resin Volume (FT3) Salt Settings (lbs./ft3) Refill Flow Rate (GPM) Unit Capacity (grains) Reserve Capacity Backwash (min) Brine/Rinse (min) Rapid Rinse (min) Refill (min). Reasons to change Level-II setting (examples) 1) Initial start up configurations. 2) Using tanks other than 9X48. 3) Using Valve for Carbon or Iron Filter. 4) Setting valve up for use in in Iron filter. 5) Adjusting any cycle or setting to enhance performance.

Making Adjustments Level II All programing is adjusted using the same methods as for Level-I programming. Setting level II programing Backwash 1) Press and together to enter menu (5 sec.). 2) Press or scroll to backwash setting. 3) Press to enter menu (flashing). 4) Press or to adjust minutes (flashing). 5) Press to save setting and advance to tenths of minute. 6) Press or to adjust tenths of minute for backwash 7) Press to save. 8) Press or to move to another menu. 9) Press to exit menu and return to main screen. Note: Valve must be in manual mode to adjust and save capacity and refill duration. *Note: If the valve is locked you will need to press and hold menu for 3 seconds. Valve will beep when changing menu s or parameters. Highlighted parameter will flash when you are able to adjust setting.

Softener Settings Level-II Parameters (factory settings) Tank Size System Language Valve Operation Regen. Mode 9X48 English Softener Meter Delay 12X52 Triple Treat English Softener Meter Delay Regen. Time 2:00 AM 2:00 AM Resin Volume Carbon Volume Unit Capacity Reserve Capacity Backwash Brine/ Rinse Rapid Rinse 1.00 None 30,000 75 10 60 10 1.00 1.0 30,000 75 10 60 10 Factory settings: Capacity Calculation (AUTO), Refill Flow Rate (0.70 GPM), 10 lbs. salt settings. All settings may be adjusted; however, to change gallons capacity and re-fill, valve must be set up in MANUAL MODE to save altered settings for these two fields.

Brine Tank Installation

Brine Tank Components (Softeners) Brine tank components are packed in the brine tank. 1) Brine tank with cover. 2) Brine well assembly. 3) Brine line Ferrell fitting and nut. 4) Salt grid with legs (4). 5) Brine line tubing (approx. 6 ft).

Installing the Salt Grid 1) Carefully line up the Brine Line hole, in the side of the tank, with the salt grid, so that the Brine Well assembly will line up to the brine line hole making it easier to plumb without bending the tubing. 2) Insert assembled salt grid, legs down. 3) Push the salt grid to the bottom of the tank, the position tabs on the outer edge of the salt grid make it a tight fit to keep the grid from floating if the tank runs out of salt.

Installing the Brine Well 1) Remove nut and tube Ferrell from brine well assembly. (Ferrell is inside the brine well tube connection) Note: you may need to retrieve Ferrell from inside fitting. 2) Insert brine well assembly into tank, push to the bottom of the tank. 3) Rotate the Brine well to line up the brine line hole in the tank and the Ferrell nut connection on the brine well assembly.

Connecting Brine Line 1) Feed brine line tube through the hole in the side of the brine tank. 2) Place Ferrell nut on tube. 3) Insert Ferrell into brine line tubing. 4) Insert tubing w/ Ferrell into brine well assembly. Note: Removing the cap, to the brine well assembly, and hold the threaded connection to make is easier to get a good seal. 5) Hand tighten Ferrell nut to brine well assembly. Brine Tank is now ready to be connected for service Do not add salt at this time!

Connect Brine & Drain Lines 1) Connect drain Line to the valve Slide drain line tube over barbed drain line connection fitting until secured. 2) Connect brine line to the valve. a) Remove Blue collet clip (hold on to it, it goes back). b) Insert 3/8 tubing into John Guest fitting. c) Press tubing in again to ensure a good seal. d) Replace blue collet clip.

Add Water to the Brine Tank Be sure to have the brine tank in its final position before proceeding. DO NOT ADD SALT AT THIS POINT Add only water to the brine tank with a sanitary hose until water is 3 4 above the grid plate. *If you are using a tank that does not have a grid plate, fill water until it is above the air check in the brine tank.

System Installation OUT Turn the by-pass valves to the OFF position (red valves) pointing across the valve as shown. IN With the faucet still on, open the main water supply valve Off Position! CAUTION: Inspect all plumbing connections. Check for leaks and make repairs as needed.

System Start Up Notice: For initial start-up, the Inlet and Outlet valves on the bypass should be in the closed position. 1) Press and hold to enter Manual Regen. Mode. (press for 3-5 seconds) 2) Press to enter edit mode (flashing). 3) Press or to select immediate (flashing). 4) Press to save. 5) Press to show Advancing to Backwash. Note: Valve will reset backwash cycle to delay after manual regen. cycle has finished.

Fill the Mineral Tank! CAUTION: Allow time for glued connections to cure before proceeding. If the mineral tank was not filled, do so at this time following the directions below: 1) With bypass valves in the OFF position turn on the main water supply. 2) Open Inlet valve slowly ¼ turn clockwise to fill the media tank. Continue to open inlet all the way.! CAUTION: Inspect all plumbing connections. Check for leaks and make repairs as needed.

Start-Up In Backwash Inlet on by-pass is open Outlet on by-pass is closed. 1) Screen will now display Backwash and flash Remaining XX min 2) Run Backwash cycle until drain line runs clear. Note: When advancing to another cycle, valve will show advancing to. Once the valve is in a subsequent cycle, you may press any button to advance to another cycle. Valve cannot be advanced in the advancing to position. Note: Watch to see if the backwash flow rate is proper do not obstruct drain line. This is particularly important for Iron and Sulfur filters.! Check for leaks and repair as needed.

System Installation Leave the system in backwash for a minimum of five to ten minutes until the water runs clear. This will flush loose particles from and preservatives from the media. REPEAT of the initial backwash cycle may be required should the backwash discharge water does not run clear after unit has finished the first cycle. Press to advance to the next cycle Advancing to Brine NOTE: It s common to run multiple backwash cycles with carbon and Iron filters due to the amount of fines in the media.

Brine Rinse (Draw) Look for the water level to drop in brine tank. NOTE: This is critical to ensure proper operation. (Hold the brine line to feel for flow) Press Press to go to Advancing to Rinse to go to Advancing to Refill

Brine Tank Re-fill Watch... The water level in the brine tank go up during refill. Otherwise there will not be sufficient brine water for the next regeneration cycle (for softeners). The water level should fill to 3 to 4 above the salt grid. (Hold the brine line to feel for the flow) Press to show Advancing to Service

Ready for Service 1) Slowly open outlet to supply water to the house. 2) Open a faucet on the treated water side in the house until water runs clear. Finally... Add salt to the brine tank.

Weather Cover (For outdoor installations)! WARNING If the water treatment system is to be installed outside, exposed to the weather and/or UV Rays, it is necessary to install a weather cover over the valve. The weather cover will protect the valve from the damaging effects of UV Rays on the LCD Screen and is required to submit a warranty claim.