Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Similar documents
Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Performance Measurement of R32 Vapor Injection Heat Pump System

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

ABSTRACT. Professor Reinhard Radermacher, Department of Mechanical Engineering

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Performance of CO2 Cycles with a Two-Stage Compressor

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Manufacturing & Testing of Air-to-Refrigerant Heat Exchangers Based on 0.8mm Diameter Tubes

Purdue e-pubs. Purdue University

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Effect of Inclination Angle on the Air-Side Performance of Aluminum Parallel Flow Heat Exchangers Under Wet Conditions

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Air-Cooled Heat Exchanger Performance for R410A

Low GWP Refrigerants for Air Conditioning Applications

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

The Effects of Hydrophilicity on Water Drainage and Condensate Retention on Air-Conditioning Evaporators

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Purdue e-pubs. Purdue University. Ian H. Bell Purdue University. Eckhard A. Groll Purdue University

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers


Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Heat Transfer Characteristics and Heat Exchanger Performances for R407C Using Herringbone Heat Transfer Tube

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Sub-Critical Operation of the CO2 Expander/ Compressor

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Investigation of Evaporator Performance with and without Liquid Overfeeding

Study of R161 Refrigerant for Residential Airconditioning

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Compression of Fins pipe and simple Heat pipe Using CFD

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Experimental investigation of the performance of industrial evaporator coils operating under frosting conditions

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Testing of Unitary Split-System Heat Pump with an Energy Recovery Expansion Device

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Simultaneous Heat and Mass Transfer in a Wetted Heat Exchanger, Part I: Experiments

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Designated vs Non-designated Areas for Condenser Subcooling

A-Type Heat Exchanger Simulation Using 2-D CFD for Airside Heat Transfer and Pressure Drop

Refrigerant Mass and Oil Migration During Start-up Transient

Experimental Investigation of Tube Configuration for a Surface Condenser

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Developing Two-Phase Flow Distribution in Horizontal Headers With Downward Minichannel-Branches

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling Yunho Hwang yhhwang@umd.edu Sahil Popli Reinhard Radermacher Follow this and additional works at: http://docs.lib.purdue.edu/iracc Hwang, Yunho; Popli, Sahil; and Radermacher, Reinhard, "Enhancement of Round Tube and Flat Tube-Louver Fin Heat Exchanger Performance Using Deluge Water Cooling" (2012). International Refrigeration and Air Conditioning Conference. Paper 1264. http://docs.lib.purdue.edu/iracc/1264 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2331, Page 1 Enhancement of Round Tube-Louver Fin Heat Exchanger Performance Using Deluge Water Cooling Sahil POPLI, Yunho HWANG*, Reinhard RADERMACHER Center for Environmental Energy Engineering Department of Mechanical Engineering, University of Maryland 4164 Glenn L. Martin Hall Bldg., College Park, MD 20742, USA * Corresponding Author Tel: (301) 405 5247, E-mail: yhhwang@umd.edu ABSTRACT An experimental study has been conducted to evaluate the performance of a compact round-tube louver-fin condenser, each with frontal areas of 0.25 m 2 in both dry and wet conditions. Deluge water cooling is achieved by incorporating a perforated bottom plate-type water distributor on top of the round tube heat exchanger. Water is used as a refrigerant, and enters the heat exchanger tubes at 35 C temperature. Ambient air and deluge cooling water are both maintained at 22 C temperature. Heat exchanger capacity and air-side pressure drop are measured with the heat exchanger angle set at 0 and 21 from vertical, with a frontal air velocity of 1.4 m/s and 3.5 m/s without deluge water cooling, and a frontal air velocity of 1.4 m/s with deluge water cooling. For both heat exchangers, the capacity was significantly enhanced with the use of deluge water cooling and with the heat exchanger angle set at 21 from vertical. 1. INTRODUCTION Compact round tube heat exchangers with plain plate or louver fin geometry are widely used as condensers and coolers in power generation, air-conditioning, refrigeration and process cooling applications. Typically air flows over the tube bundle through fin-side of the heat exchanger and condenses or cools the heat transfer fluid circulating through tube-side. Since heat transfer in such heat exchangers is constrained on air-side due to high thermal resistance, enhanced fin surfaces are typically utilized to increase fin-tube heat exchanger performance (Wang et al., 1999). Extended surfaces are often incorporated with a series of flow interruptions such as louvers and off-strips that induce turbulent mixing of air flow and prevent growth of thermal boundary layer from leading edge (Chang and Wang, 1997). Due to low manufacturing cost louver fins are more commonly used to enhance heat transfer in fin tube heat exchangers. However, at high ambient air-conditions air-cooled even louvered fin round-tube heat exchangers do not provide sufficient cooling capacity and higher condenser temperature reduces thermodynamic cycle efficiency by up to 1% for every degree increase in condensing temperature (Leidenfrost et al., 1979). In addition, further increase in fin density provides marginal increase in capacity at the cost of considerable increase in air-side pressure drop. One way to enhance heat transfer in louvered fin round-tube heat exchangers is to utilize deluge or spray water cooling (Yank and Clark, 1975). The water forms a thin film over heat exchanger tubes which enhances air-side heat transfer through latent heat of evaporation at the interface and forced convection in liquid film. This forms the objective of work presented in this paper which experimentally evaluates round tube louver-fin heat exchanger performance as hybrid condenser in dry conditions and wet conditions using deluge water cooling. Condenser capacity of round tube heat exchanger has been experimentally evaluated in dry conditions by several authors in the past including, Rich (1973), Elmahdy and Biggs (1979), Senshu et al. (1981), Gray and Webb (1986), Kang et al. (1994), Wang et al. (1996), and Yan and Sheen (2000). Rich (1973) experimentally tested a four row heat exchanger and found that both heat transfer and friction factor to be independent of fin pitch. It was also found that heat exchanger capacity reduces with increase in number of tube rows at low Re and increases slightly for high Re numbers.

2331, Page 2 Elmahdy and Biggs (1979) presented an empirical correlation of dry case heat transfer in flat plate round tube condenser with multi-row staggered tube valid over 200 to 2,000 air side Re. Senshu et al. (1981) conducted experiments on two-row round tube heat exchanger and found the effect of longitudinal and transverse fin pitch on heat transfer coefficient to be insignificant. Wang et al. (1996) found the effect of fin spacing on heat transfer capacity and effect of fin thickness on both heat transfer capacity and air-side pressure drop to be negligible. Yan and Sheen (2000) reported an increase in both heat exchanger capacity and air-side pressure drop for heat exchangers with smaller fin pitch. Therefore, there is an agreement that smaller fin pitch increases air-side pressure drop while heat transfer capacity is relatively unaffected. Kang et al. (1994) experimentally determined effect of fin spacing and geometry on condenser heat transfer and air-side pressure drop for slotted plain fin, wavy fin and plain plate fin heat exchangers with 2.0, 2.6 and 3.2 mm fin spacing for all fin geometries. Highest and lowest dry case condenser capacity was obtained for slotted plain fin and plain plate fin configuration, respectively. In comparison to condenser performance data of round tube heat exchanger in dry conditions, published experimental studies in wet conditions is limited in the open literature. Yank and Clark (1975) experimentally investigated the effect of spray cooling 1.26 to 2.52 ml/s water and ethylene glycol mixture on heat transfer capacity and air-side pressure drop of plain-finned, louvered, and perforated fin heat exchangers with 3.94 copper fins per cm. It was found that spray cooling does not affect pressure drop and heat transfer coefficient is enhanced by approximately 40% and 45% for air Reynold numbers of 1,000 and 500, respectively. The authors attributed a lower enhancement in condenser capacity at higher Re air =1,000 to break up of liquid film on fin surface. Furthermore as spraying both water and ethylene glycol provided similar improvement in heat exchanger condenser capacity, it was concluded that thin film formation contributes more towards condenser capacity enhancement than latent heat of vaporization. COP enhancement and energy saving of approximately 211% and 58% was reported by Vrachopoulos et al. (2007) for typical refrigeration systems utilizing spray cooled round tube heat condensers. Leidenfrost et al. (1979) developed a mathematical model to evaluate condenser capacity of evaporative cooled plate-fin round-tube heat exchanger at different air and wetting water flow rates. It was found that the condenser capacity could be increased by a factor of approximately three and five for saturated inlet air and low inlet air humidity respectively in wetting conditions and refrigeration cycle COP could be increased by up to 37%. Therefore, it is established that deluge or spray water cooling could enhance heat transfer capacity of fin tube heat exchangers that could enhance power plant efficiency, refrigeration cycle COPs and offer substantial energy savings. However, there is no experimental study which focuses on condenser performance of compact round tube louver fin heat exchangers in hybrid conditions. Therefore, the objective of this paper is to experimentally evaluate condenser heat transfer capacity and air-side pressured drop for round tube louver fin heat exchangers in both dry and wet conditions and investigate the effect of wetting on heat exchanger heat transfer louvered-fin surfaces. 2. EXPERIMENTAL FACILITY OVERVIEW This section describes the experimental facility presented in Figure 1 used for testing the condenser performance of round-tube louvered-fin heat exchanger in dry and wet conditions. The experimental setup mainly consists of airside, refrigerant-side and wetting-water side loop which are discussed in Sections 2.1, 2.2 and 2.3, respectively. Table 1 presents the specifications for off-the-shelf round-tube louvered-fin test heat exchanger which is mounted in the test section of the experimental setup shown in Figure 1. 2.1 Air-side Loop The schematic of air-side loop in experimental facility which is a typical calorimetric wind-tunnel consisting of an axial fan, nozzles, air-mixer, guide vanes, visualization section, heat exchanger and wetting water drain is presented in Figure 2. Variable frequency drive (VFD) controlled the speed of axial fan, which drives the air-flow out of the wind tunnel at the desired test case velocity. Heat exchanger was installed in the wind-tunnel with a provision of varying angle of inclination of heat exchanger with vertical from approximately 0 to 60 as shown in Figure 2. Relative humidity (RH) and temperature of air were recorded at inlet and outlet of heat exchanger using a PT 100 RH sensor and a 3x3 T-type thermocouple grid respectively. Air mixer, guide vane and settling means were installed to ensure uniform flow and accurate measurement of RH and temperature measurement at the outlet.

2331, Page 3 Figure 1: Experimental facility used for testing the condenser performance of round-tube louvered-fin heat exchanger in dry and wet conditions. Table 1: Specifications for round tube heat exchanger. Parameter Value Tube Configuration Staggered Divergent Number of Tube Banks 4 Number of Tubes per Bank 20 Tube Length (mm) 454 Tube Outer Diameter (mm) 10.6 Tube Thickness (mm) 0.35 Tube Horizontal Spacing (mm) 17.8 Tube Vertical Spacing (mm) 22.9 Fins per Inch 16 Fin Thickness (mm) 0.18 Heat Exchanger Length (mm) 406 Heat Exchanger Width (mm) 101 Figure 2: Schematic of air-side loop in experimental facility

2331, Page 4 The differential pressure across the heat exchanger and nozzles was measured using differential pressure transducer in accordance with ASHRAE Standard 41.2 (1987). The differential pressure across the nozzles was then used to calculate the air velocity and flow rate. Heat exchanger was sealed at the walls of test section to prevent bypass of air-flow and entire air-side loop is closed to minimize energy-losses. 2.2 Refrigerant Loop Schematic of refrigerant-side loop in experimental facility is presented in Figure 3. Hot water used as heat transfer fluid enters the test heat exchanger at 35 C and is cooled by air flowing through louver fins across the condenser tubes in dry case tests. When wetting water was used a two-phase flow of air and wetting water cools the heat transfer fluid flowing through condenser tubes. Temperature of hot water was measured at inlet and outlet of test exchanger using high precision PT 100 resistance temperature detector (RTD). Tap water was used as hot water fluid. Valve V2 provided water used for priming the centrifugal pump prior to start-up. A 0.75 kw VFD controlled centrifugal pump drives flow through hot-water loop which consists of a water filter placed before turbine flow meter. The desired temperature at test exchanger inlet was maintained using heat supplied by a typical R-22 heat pump cycle using 4 kw fixed speed compressor, and a 4 kw auxiliary heater. Heat pump cycle was incorporated with a bypass valve between the compressor outlet and evaporator outlet, which enabled reducing the capacity of test heat exchanger condenser without changing the speed of the compressor by allowing certain amount of refrigerant to bypass from the compressor discharge line back to suction line. A 15 kw water chiller was utilized to cool overheated water and serves as additional temperature control along with bypass and temperature control valves. Figure 3: Schematic of hot water loop in experimental facility 2.3 Wetting-Water Loop Figure 4 presents the schematic of hot water and wetting water loop in experimental facility. Deluge water required for testing condenser performance in wet conditions was distributed evenly over test round tube heat exchanger using a perforated bottom tray-type applicator shown in Figure 5 which was designed to allow 0.16 l/s wetting water to fall over heat exchanger tubes. Tap water was used as wetting water fluid. Valve V6 provided water used for priming the centrifugal pump prior to start-up. Temperature of wetting water was measured at inlet and outlet of test exchanger using high precision PT 100 RTD. A 0.25 kw fixed speed centrifugal pump drives flow through wettingwater loop which also consists of a turbine flow meter. The wetting water flow can be controlled using ball-valve V7 shown in Figure 4. Wetting water can be cooled or kept at a constant inlet temperature using a 15 kw vapor compression water chiller.

2331, Page 5 Figure 4: Schematic of hot water and wetting water loop in experimental facility Figure 5: Perforated bottom plate-type water distributor on top of round tube heat exchanger 2.4 Test Conditions and Measuring Instruments Experimental test matrix, and air, refrigerant and wetting water parameters for testing round-tube louver-fin heat exchanger are summarized in Tables 2 and 3, respectively. Dry case tests were performed at 1.4 m/s and 3.5 m/s air velocity with heat exchanger at 0 and 21 angle, and at 1.4 m/s with heat exchanger at 0 and 21 angle for wet case. Heat exchanger was not tested at higher air velocity as wetting water was blown out of the condenser. Table 4 summarizes the systematic error of each instrument used in the experimental analysis.

2331, Page 6 Table 2: Experimental test matrix for round-tube louver-fin heat exchanger Test No. Case Air Velocity (m/s) Angle 1 1 Dry 1.4 0 2 Dry 3.5 0 3 Wet 1.4 0 4 Dry 1.4 21 5 Dry 3.5 21 6 Wet 1.4 21 Note: 1. Angle of heat exchanger with the vertical. Table 3: Air, refrigerant and wetting water parameters for testing round-tube louver-fin heat exchanger Parameter Average Value Unit Air Parameters Inlet temperature 294.5 to 295.1 K Heat exchanger frontal air velocity 1.2 m/s 3.5 m/s Heat exchanger angle with vertical 0, 21 degrees Refrigerant Parameters Inlet temperature 308 to 308.4 K Mass flow rate 2.9 m 3 /s*(10 4 ) Wetting-Water Parameters Inlet temperature 294.5 to 295.1 K Mass flow rate 1.6 m 3 /s*(10 4 ) Table 4: The systematic error of each instrument used in the experiment Instrument Type Range Systematic Uncertainty Unit Water mass flow meter Turbine 0.63 to 6.3 ±1% full scale m 3 /s*(10 4 ) Wetting water mass flow meter Turbine 1.1 to 10.1 ±1% full scale m 3 /s*(10 4 ) RTD PT 100 173 to 673 ±0.06 K Thermocouple T-Type 73 to 623 ±0.5 K Relative humidity sensor PT 100 0 to 90 ±2 % Differential pressure transducer Strain 0 to 1245.0 ±1% full scale Pa 3. Results and Discussion Experimentally measured air, refrigerant and wetting-water parameters such as flow rate, temperature and relative humidity are used to calculate condenser heat transfer capacity in dry and wet conditions. Experimental test conditions for each test in Table 2 are summarized in Table 3. Dry case air-side capacity,, is calculated using Equation (1).,,,, (1) Both dry and wet case refrigerant-side capacity,, is calculated using Equation (2). Equation (3) is used to calculate dry case energy balance,,. (2)

2331, Page 7 (3) Wet case air-side capacity,, is calculated using Equation (4).,, 1 (4) Wetting-water capacity,, is calculated using Equation (5).,,,, (5) Equation (6) is used to calculate dry case energy balance,,. The total uncertainty of measured variables such as air-aide pressure drop is calculated using the sum of systematic error of each instrument as summarized in Table 4 and random error which is the standard deviation of measured variable. Round tube heat exchanger capacity, air-side pressure drop and energy balance along with measurement uncertainty is presented in Table 5. The energy balance in both dry and wet case studies was found to be less than 5%. Table 5: Round tube heat exchanger capacity, air-side pressure drop and energy balance along with measurement uncertainty. S. No Case Air Velocity (m/s) Angle 1 Heat Exchanger Air-side Pressure Energy Balance Capacity (W) Drop (Pa) (%) 1 Dry 1.4 0 2912± 211 27±13 4.2 2 Dry 3.5 0 5069±203 132±14 3.0 3 Wet 1.4 0 7652±227 64±14 2.0 4 Dry 1.4 21 2953±228 29±13 1.2 5 Dry 3.5 21 5128±230 137±14 4.2 6 Wet 1.4 21 8311±291 67±14 0.6 (6) A comparison of heat exchanger capacity and air-side pressure drop at 0 and 21 angle for both dry and wet conditions at different air-velocities is presented in Figures 6 and 7, respectively. As shown in Figures 6 and 7, increasing air velocity from 1.4 m/s to 3.5 m/s enhances the condenser heat transfer capacity and air-side pressure drop by approximately 74% and 380%, respectively, for both 0 and 21 angle of heat exchanger with the vertical. The capacity increase is achieved at the cost of a substantial increase in air-side pressure drop. Therefore, it is clear that increasing air velocity to 3.5 m/s is not a good option to enhance heat exchanger condenser capacity. It is also observed that in dry conditions, changing the angle of heat exchanger has a negligible effect on heat transfer capacity and on air-side pressure drop for round tube louver-fin heat exchanger. Deluge water cooling was provided to condenser by wetting water at approximately 22 C which flowed through a perforated bottom tray type applicator installed on top of test heat exchanger. At 1.4 m/s air velocity deluge water cooling enhances heat transfer capacity of the heat exchanger by approximately 162% and 181% and air-side pressure drop by approximately 137% and 135% for 0 and 21 angle, respectively with the vertical. As a result it is concluded that increasing the heat exchanger angle enhances heat transfer rate of the condenser due to enhanced drainage of wetting water through narrow fin spacing. Similar to the dry case results, changing the angle of heat exchanger resulted in a negligible change in air-side pressure drop for round tube louver-fin heat exchanger tested at 1.4 m/s in both dry and wet conditions.

2331, Page 8 Heat Exchanger Capacity (kw) 10 9 8 7 6 5 4 3 2 1 0 0 Angle 21 Angle Dry Case (1.4 m/s) Dry Case (3.5 m/s) Wet Case (1.4 m/s) Figure 6: Comparison of round tube heat exchanger capacity at 0 and 21 angle for both dry and wet conditions at different air-velocities. 160 140 0 Angle 21 Angle Air-side Pressure Drop (Pa) 120 100 80 60 40 20 0 Dry Case (1.4 m/s) Dry Case (3.5 m/s) Wet Case (1.4 m/s) Figure 7: Comparison of round tube heat exchanger airside pressure drop at 0 and 21 angle for both dry and wet conditions at different air-velocities. 5. CONCLUSIONS Round tube louver fin compact heat exchanger condenser s capacity and air-side pressure drop are experimentally evaluated in both dry and wet conditions. It is found that under dry conditions increasing the air velocity from 1.4 to 3.5 m/s enhances heat exchanger capacity and air-side pressure drop by approximately 74 % and 380%, respectively in case of both 0 and 21 angle with vertical. Thus increasing the air velocity in dry conditions causes a much higher pressure drop that does not justify the increase in heat exchanger capacity. Furthermore, in dry conditions there is no significant effect of angle of inclination on both heat exchanger capacity and air-side pressure drop.

2331, Page 9 Under wetting conditions, heat exchanger capacity increases by 162% and 181%, and pressure drop increases by 137 % and 135 %, respectively for the case of 0 and 21 angle with vertical. Therefore, use of wetting water and change in angle of the heat exchanger with the vertical, offer better options for enhancing condenser heat transfer capacity compared to increase in air velocity. Thus, it is clear that significant capacity enhancement can be achieved by deluge cooling of compact round tube heat exchangers. Moreover, this work lays the foundation for several comprehensive studies that could be performed in the designed experimental facility to test the effect of wetting on hot heat exchanger surfaces by varying wetting water flow rate, angle of inclination, air velocity, orientation of heat exchanger tubes, fin geometry and applying various coatings to develop best wetting strategy for different heat exchangers. It is envisaged that such studies would enhance understanding of water hold up mechanisms, wetting water application methods, expected heat and mass transfer improvements, and optimized geometry for sufficient water evaporation to maximize energy efficiency, and water economy for compact round tube heat exchangers. NOMENCLATURE COP coefficient of performance ( ) Subscripts h enthalpy (J/kg) a air mass flow rate (kg/s) eb energy balance heat transfer rate (W) in inlet stream ρ density (kg/m 3 ) out outlet condition T temperature ( C) w water V volume flow rate (m 3 /s) ww wetting water x humidity ratio ( ) REFERENCES ASHRAE, 1987, Standard Methods for Laboratory Airflow Measurement, ANSI/ASHRAE 41.2-1987. Chang, Y.J., and Wang, C.C., 1997, A generalized heat transfer correlation for louver fin geometry, Int. J. Heat Mass Transfer, vol. 40, no. 3: p. 533-544. Elmahdy, A. H., Biggs, R. C., 1979, Finned tube heat exchanger correlation of dry surface heat transfer data, ASHRAE Transactions, vol. 85, no.2: p. 262-273. Gray, D. L., and Webb, R L., 1986, Heat Transfer and Friction Correlations for Plate Finned Tube Heat Exchangers Having Plain Fins, Proceeding 8th International Journal of Heat Transfer Conference, Vol. 6, p. 2745-2750. Kang, H.J., Li, W., Li, H.Z., Xin, R.C., and Tao, W.Q., 1994, Experimental Study on Heat Transfer and Pressure Drop Characteristics of Four Types of Plate Fin and Tube Heat Exchanger Surfaces, J. of Thermal Science, vol. 3, no. 1. Leidenfrost, W., and Korenic, B., 1979, Analysis of Evaporative Cooling and Enhancement of Condenser Efficiency and of Coefficient of Performance, Warme-und Stoffubertragung, vol. 12, p. 5-23. Rich, D. G., 1973, The Effect of Fin Spacing On the Heat Transfer and Friction Performance of Multi Row, Smooth Plate Fin-and-Tube Heat Exchangers, ASHRAE Trans., vol. 79, p. 137-145. Senshu, T., Hatada, T. and Ishibane, K., 1981, Heat and Mass Transfer Performance of Air Coolers under Wet Conditions, ASHRAE Transactions, p. 109-115. Wang, C. C., Chang, Y. J., Hsieh, Y. C. and Lin, Y. T., 1996, Sensible Heat and Friction Characteristics of Plate Fin and Tube Heat Exchangers Having Plane Fins, Int. J. Refrigeration, vol. 4, p. 223 230. Wang, C. C., Lee, C.J., Chang, C.T., and Lin, S.P., 1999, Heat transfer and friction correlation for compact louvered fin and tube heat exchangers, Int. J. Heat Mass Transfer, vol. 42, p. 1945-1956. Yan, W. M. and Sheen, P. J., 2000, Heat Transfer and Friction Characteristics of Fin-and Tube, Heat Exchangers, Int. J. Heat Mass Transfer, vol. 43, p. 1651-1659. Yang, W.J., and Clark, D.W., 1975, Spray Cooling of Air-Cooled Compact Heat Exchangers, Int. J. Heat Mass Transfer, vol. 18, p. 311-317. Vrachopoulos, M.G., Filios, A.E., Kotsiovelos, G.T., and Kravvaritis, E.D., 2007, Applied Thermal Engineering, vol. 27, p. 823-828.

2331, Page 10 ACKNOWLEDGEMENT We gratefully acknowledge the support of this effort from the sponsors of the Alternative Cooling Technologies and Applications Consortium, the Center for Environmental Energy Engineering (CEEE) at the University of Maryland, and Güntner AG.