General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

General Specifications

Model 144H. Product Data Sheet , Rev DB February Content

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Software Version 2.01 LEVEL MONITOR MODEL 220

General Specifications

Sanitary Pressure Transmitter

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Process Gas Chromatograph

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Model 144H. Product Data Sheet , Rev DB February Content

Enraf Servo Gauge 854 XTG

EXA Conductivity & Resistivity Analysers

Model DM8 Vibration Type Density Meter

Rosemount 2051T In-Line Pressure Transmitter

Absolute and Gage Pressure Transmitter

Dräger Polytron 5720 IR Toxic Gas Detection

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Enraf Servo Gauge 854 ATG

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

High Pressure Conductivity Monitor

Rosemount 2090P Pulp and Paper Pressure Transmitter

Dräger Polytron 5720 IR Detection of carbon dioxide

General Specifications

Dräger Polytron 8720 IR Detection of carbon dioxide

OIL FILM DETECTOR (Long-distance correspondence Version)

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Annubar Flowmeter Series

User s Manual YTA610 and YTA710 NEPSI Certification

ALTAIR 5X Multigas Detector Product Specification

Temperature Measurement Transmitters for field mounting

SIL 2. Ultima X Series Gas Monitors CERTIFIED

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

General Specifications

Rosemount 2090F Hygienic Pressure Transmitter

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 8100 EC Detection of toxic gases and vapors

ULTIMA X5000. MSAX5000.com

WH EN IGH T T C LO SED

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

SEC Signature Process Gas Analyzer

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Rosemount 2051T In-line Pressure Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Models TX-KE and TX-KP Toxic Gas Transmitters

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Temperature Controllers

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

PUV, PIR and PFO Series BROCHURE

Two global companies, one solution.

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Certificate of Compliance

Continuous level measurement Ultrasonic transmitters

General Specifications

Dräger Polytron 7000 Fixed gas detector

Section B Field Instruments

Dräger Polytron 7000 Detection of toxic gases and oxygen

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Certificate of Compliance

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Transmitters/Sensors. OLCT Series

Dräger Polytron Pulsar 2 Open Path Gas Detector

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Dräger Polytron 8310 Stationary gas detector (DSIR)

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Technical Data. Dimensions

General Specifications

Level Measurement Continuous level measurement - Ultrasonic transmitters

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Low Temperature Zirconia Oxygen Analyzer

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Model D12-IR. Digital Gas Transmitter...

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Druck DPI 705/DPI 705 IS Series

Ultrasonic Switches. Features & Benefits

Transcription:

General Specifications Model GD402 Gas Density Meter Overview The Model GD402 gas density analyzer and Model GD40 detector not only provide continuous measurement of gas density, but also several other valuable parameters, including specific gravity and molecular weight. The GD40 detector is designed for intrinsically safe and explosion-proof, explosion protected applications. It is designed to be virtually maintenance free for all accepted applications. The Model GD402 is a rugged microprocessor-based converter designed in two versions to meet both general area and explosion-proof application requirements. In addition to the display of several key data items, the converter also provides the choice of three different means for calibration: automatic; semi-automatic and one-touch manual operation. Features Proven design Highly responsive and sensitive measurement of density. Specific gravity, molecular weight and gas concentration can also be displayed using Yokogawa's gas density analyzing techniques. Detector features 1. Resistant to external vibrations. 2. Outstanding stability against sudden changes in gas temperature (within 1 g/m 3 for sudden changes in gas temperature of 10 C). 3. The multi-mode self-oscillation circuit minimizes drift caused by the sensor itself or by oil mist, dust, moisture, etc. sticking to the sensor. 4. Easy cleaning and regeneration of sensor. Should the sensor be contaminated with dust and/or mist, then it can be easily cleaned and returned to its original condition. 5. Only routine maintenance is required. (for example, once per 3 months depending on application.) Simple, user-friendly interface Configuration can be performed locally via the front panel or remotely by using the (optional) "Brain" terminal. Low installation cost Both explosion-proof and general purpose converters are designed for easy mounting on a pipe. Wiring between the detector and converter is based on a two-wire system, keeping installation cost to a minimum. GD40G, R, T, V Detector GD402G General Purpose Converter GD402R, T, V Explosion-proof Converter Certificate is approved for model GD402G, GD402R, GD40R. Copyright Oct. 1997 (YK) 2nd Edition: June 2000 (YG)

2 1. General Specification 1.1 System Components (1) GD40G,T,R,V detector : Rainproof for outdoor use (equivalent to IP65 / NEMA 4X) (see note under 2.2 Ambient condition on page3.) Ambient Temperature : 10 to 60 C Ambient Humidity : 5 to 95%RH GD40T : FM Explosion-proof and Intrinsically safe Approval. Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. with Intrinsically Safe sensor for Class I, II, III, Division 1, Groups B, C, D, E, F and G. Enclosure : NEMA Type 4X Temperature Code : T5 Electrical connection : 1/2NPT female Process connection : 1/4NPT female GD40V : CSA Explosion-proof and Intrinsically safe Approval. Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. with Intrinsically Safe sensor for Class I, II, III, Division 1, Groups B, C, D, E, F and G. Enclosure : Type 4X Temperature Code : T5 Electrical connection : 1/2NPT female Process connection : 1/4NPT female GD40R : TIIS Explosion-proof and Intrinsically safe Approval. Explosion-proof code : Exd [ia] IIB+H2T5 Temperature Code : T5 Electrical connection : G3/4 female Process connection : Rc1/4 female (2) GD402G, T, V, R Converter : Rainproof for outdoor use (equivalent to IP65 / NEMA 4X) Ambient Temperature : 10 to 55 C Ambient Humidity : 5 to 95%RH GD402G: General purpose converter. (Non Explosionproof) Electrical connection : 21mm (0.9inch) in diameter. Pg13.5 cable glands included GD402T : FM Explosion-proof Approval. Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Enclosure : NEMA Type 4X Temperature Code : T5 Electrical connection : 1/2NPT female GD402V : CSA Explosion-proof Approval. Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Enclosure : Type 4X Temperature Code : T5 Electrical connection : 1/2NPT female GD402R : TIIS Explosion-proof Approval. Explosion-proof code : Exd [ia] IIB+H2T6 Temperature Code : T6 Electrical connection : G3/4 female (3) EJA310 Absolute press transmitter (optional) FM Explosion-proof Approval: Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Hazardous(classified locations, indoors and outdoors (NEMA 4X) Temperature Code : T6 Ambient Temperature : 40 to 60 C Ambient Humidity : 5 to 100%RH (at 40 C) Electrical connection : 1/2NPT female Process connection : 1/4NPT female CSA Explosion-proof Approval: Explosion-proof for Class I, Division 1, Groups B, C and D; Dust Ignition-proof for Class II, III, Division 1, Groups E, F and G. Division2 SEALS NOT REQUIRED Enclosure : Type 4X Temperature Code : T4, T5, T6 Max. Process Temp.: T4 120 C, T5 100 C, T6 85 C Ambient Temperature : 40 to 80 C Ambient Humidity : 5 to 100%RH (at 40 C) Electrical connection : 1/2NPT female Process connection : 1/4NPT female TIIS Explosion-proof Approval: Explosion-proof code : Ex do IIC T4X Temperature Code : T4 Ambient Temperature : 20 to 60 C Ambient Humidity : 5 to 100%RH (at 40 C) Electrical connection : G1/2 female Process connection : Rc1/4 female *1 FM Explosion-proof and Intrinsically Safe Approval. *2 CSA Explosion-proof and Intrinsically Safe Approval. *3 TIIS Explosion-proof and Intrinsically Safe Approval. *4 FM Explosion-proof Approval. *5 CSA Explosion-proof Approval.

3 1.2 Characteristics GD402 specification list Item 3 3 Density kg/ m Density lb/ft Specific Gravity M olecular Weight MW Concentration vol% Range 0-6 0-0. 4 0-5 0-140 0-100 Minimum Range 0. 1 0.01 0. 1 4 Response Time 90% approx. 5 sec approx. 5 sec approx. 5 sec approx. 5 sec approx. 5 sec Linearity +/- (0.001 range) + 1 % of set 4 + /- (1x10 + 1% of set range - ) + 1 % of +/- (0.001 set range) + /- 1 % of set range +/- 1 Repeatability + /- 0.001 /- 1 x 10 4 + - /- 0.00 1 Long term stability + + /- 0.02 +/- 0. 5 + /- 0.003/month + /- 0.0002/month + /- 0.003/month + /- 0.07 /month +/- 0.5 /month Density is the basic measurement, the other representations are derived from the Density data. Item H2 in Air vol% H2 in CO2 vol% Air in CO2 vol% Range 85-100 0-100 0-100 Minimum Range Response Time 90% approx. 5 sec approx. 5 sec approx. 5 sec Linearity +/- 1 +/- 1 +/- 1 Repeatability +/- 0.5 +/- 0.5 +/- 0.5 Drift +/- 0.5 /month +/- 0.5 /month +/- 0.5 /month Caloric value MJ/m 3 British Thermal Unit kbtu/ft 3 0-130 0-3.5 8 0.25 approx. 5 sec approx. 5 sec +/- 1 % of set range +/- 1 % of set range +/- 0.040 +/- 0.001 +/- 0.1 /month +/- 0.0025 /month Caloric Value and BTU are possible representations of the Density. GD402 does not contain table information, only a single mathematical equation. 1.3 Output Signals Output 1: 4-20 ma DC Isolated from inputs; load resistance: 600Ω maximum (Load resistance of 250-550Ω required when in the BRAIN communication mode) Output 2: 4-20 ma DC Isolated from inputs; load resistance: 600Ω maximum 1.4 Power Supply Rated voltage range: 100 to 240 V AC, 24V DC Allowable voltage range: 85 to 264 V AC, 21.6 to 26.4V DC Rated frequency: 50 or 60 Hz Allowable frequency range: 47 to 63 Hz 1.5 Power Consumption Approximately 12 W. 2. GD40G,R Detector For flow rate and allowable pressure, see page 5. 2.1 Material exposed to gas SUS316 stainless steel, NBR and FRM 2.2 Ambient conditions Temperature: -10 to 60 C (14 to 140 F) Humidity: 5 to 95% RH Installation: Pipe-mounted or on panel Construction: Intrinsically safe, Explosion-proof Though the detector construction makes it relatively insensitive to sudden changes in the gas temperature, extra precision can be achieved by keeping ambient temperature conditions as constant as possible. In measurements where optimum precision is required it is therefore not recommended to install the detector in an outdoors environment, especially not if such installation is prone to direct sunlight. 2.3 Finish Cover: equivalent to Munsell 0.6GY3.1/2.0 Case: equivalent to Munsell 2.5Y8.4/1.2 2.4 Weight Appox. 7 kg (with Pipe-mounting Bracket) 2.5 Detector unit When the system is ordered to be used as a hydrogen purity analyzer an optional pressure analyzer is required for pressure compensation. If /EJAJ1 or /EJAF2/EJAF3/EJAF4 are ordered, the detector unit and the pressure transmitter and the tubing in between will all be integrated on a single mounting plate. This allows the space where the pressure transmitter is normally mounted to be used effectively for other purposes. 2nd Edition 2000.05.10-00

4 3. GD402G or GD402R Converter 3.1 Display Reading: Digital (5 digits maximum) Data items shown: Measured value: Always on display. Alarm indications: Abnormal concentration, abnormal pressure range of input and abnormal values of calibration Parameters for calibration: Time of calibration, settling time, starting time of calibration and calibration cycle Self-diagnostic indications: Sensor oscillation shutdown, abnormal oscillation frequency of sensor, failure in sensor temperature detection, failure in A/D conversion stage and memory failure Alarm settings: The contact state can be set to either normally open (NO) or normally closed (NC) depending on the needs of the application. Temperature: Temperature of gas being measured 3.2 Contact Outputs/Input Contact output: Contact capacity: 250 V AC at 3A or 30 V DC at 3A Types of signals: Maintenance, Fail, Hi/Lo alarms Contact input: Signal for switching between the Hydrogen Purity meter and the Replacement meter 3.3 Calibration Manual (one touch), Semi automatic, Automatic calibration 3.4 Communication Protocol: BRAIN communication Data items that can be transmitted by the hand-held terminal are numerical data, such as concentration, temperature and pressure, alarm setpoint and selfdiagnostic parameters. 3.5 Ambient Conditions Temperature: -10 to 55 C (14 to 131 F) Humidity: 5-95% RH 3.6 Installation Non-explosion-proof models: Pipe-, panel- or wall-mounted Explosion-proof models: Pipe-mounted 3.7 Finish Model GD402G (general purpose): Front cover:equivalent to Munsell 0.6GY3.1/2.0 Case:equivalent to Munsell 2.5Y/8.4/1.2 Model GD402R (explosion-proof): equivalent to Munsell 0.6GY3.1/2.0 3.8 Weight Model GD402G (general purpose): approx. 3 kg (6.6 pounds) Model GD402T, V, R (explosion-proof): approx. 15 kg (33.1 pounds) MODEL SPECIFICATIONS 1. Gas Density Converter Model GD402G GD402T GD402V GD402R Power supply Label and approval Basic code -D -A -E -J Instruction Manual -E Options Option code /PA /U Description General purpose model, 6 cable glands included. FM certified explosion proof model. Gland threads 1/2NPT. No cable glands included. CSA certified explosion proof model. Gland threads 1/2NPT. No cable glands included. TIIS certified explosion proof model. Gland threads G3/4. No cable glands included. 24V DC 100-240V AC English label TIIS approval, English label (only GD402R) English Panel mounting Universal (Pipe and Wall) Mounting [Note] Mounting hardware is for only GD402G. Explosion -proof models, GD402T, V, R have only pipe-mounting hardware as standard. 2-1. Gas Density Detector Model GD40G GD40R Label approval Options Basic code -E -J Option code /EJAJ1 /EJAF2 Description General purpose detector. NPT 1/4 gas threads and NPT 1/2 gland threads. No cable gland included. Mounting hardware included. TIIS certified explosion proof detector. Rc1/4" gas threads and PF 1/2" gland threads. Cable gland included. Mounting hardware included. English label, no approval (only GD40G) TIIS approval, English label (only GD40R) TIIS certified EJA mounted with detector on mounting plate. Rc 1/4" gas threads and PF 1/2" gland thread. Cable gland included. (only GD40R) EJA mounted with detector on mounting plate. NPT 1/4" gas threads and NPT 1/2" gland threads. No cable gland included. (only GD40G)

5 2-2. Gas Density Detector Model Basic code Option code Description GD40T FM certified explosion proof detector. 1/4NPT gas threads and 1/2NPT gland thread. No cable gland included. Mounting hardware included. GD40V CSA certified explosion proof detector. 1/4NPT gas threads and 1/2NPT gland thread. No cable gland included. Mounting hardware included. Options /EJAF3 FM certified EJA mounted with detector on mounting plate. 1/4NPT gas threads and 1/2NPT gland thread. No cable gland included. (only GD40T) /EJAF4 CSA certified EJA mounted with detector on mounting plate. 1/4NPT gas threads and 1/2NPT gland thread. No cable gland included. (only GD40V) 3. Hardware for Connection with External Cables (For Explosion-Proof use) Part No. L9811LL Description G3/4 explosion proof cable gland. Cable's outside diameter 8 to 16 mm. Used for the GD402R converter. Note: Specify the number of cable glands for converter in hazardous area. 5. Brain Terminal (Optional) Model Suffix Codes Description BT200 Brain terminal [Note] Printer Options -N -P 00 Standard type (without printer) With printer Always 00 / [Note] BT200 has following accessories, two communication cables, one with IC clips and another with alligator clips, handy carrying case and five AA 1.5 V dry batteries. OPTIONS FOR BT200 Options Description Option codes Communication cable With a 5-pin connector (Note 1) (for the signal conditioner) C1 Intrinsically safe type CSA Intrinsically safe approval (Note 1)(Note 2) Class I, Groups A, B, C and D Temp. CS1 Code:T4 (Note 1) Optional code /C1 can not be combined with /CS1. (Note 2) Applicable only for Model BT200-N00. See GS1C0A11E for "BT200" brain terminal in detail. 6. Pressure transmitter (optional) /EJAJ1 means EJA310-DAS0A-80NN/JF3/G11/A/K1 /EJAF2 means EJA310-DAS5A-87NN/A/K1 /EJAF3 means EJA310-DAS5A-87NN/FF1/A/K1 /EJAF4 means EJA310-DAS5A-87NN/CF1/A/K1 See GS1C21D1-E for "EJA310" pressure transmitter in detail if a different selection from pre-selected options seems necessary. 4. Two-Core, Double-Shielded Cable Normally two conductor shielded cable can be used, but when failure arises from noises disturbance, this cable is recommended for connection between the GD402 converter and GD40 detector. Model GDW Basic code Description Two core, double shielded cable, both ends finished with cable pins. Length -L Length in meters, 500 meter maximum.

6 System Configuration (for wiring, see Instruction Manual IM11T3E1-01E.) Sample gas line Filter Switching valve Flowmeter Note 3 Note 1 P1 Note 2 P2 P EJA (Explosion-proof pressure transmitter) Gas for zero point calibration Note 4 Note 4 Detector unit Note 5 (Supplied by Yokogawa) Gas for span point calibration Note 4 Pressure regulator for gas cylinder Supplied by customer. Note 1: P1 (inlet pressure) Max. 0.5 MPa (71psi) Note 2: P1 (inlet pressure) - P2 (outlet pressure) 0.5 kpa (0.071psi) (depending on the size and length of the pipe) Note 3: Flowrate = 0.1 to 1 l/min Note 4: The cylinder pressure must be reduced to P1 (inlet pressure). Note 5: Optional /EJAJ1, EJAF2, EJAF3, EJAF4 and GD40 detector mounted on plate.

7 WIRING DIAGRAM (See Instruction Manual IM11T3E1-01E for details on cable installation.) GD402 Converter MAINTENANCE contact output *5 ALARM contact output *5 FAIL contact output *5 FUNCTION contact output *5 SELECT GAS contact output *5 Power supply, 85 to 264 V AC or 21.6 to 26.4 V DC *1 *8 14 15 16 17 18 19 20 21 22 23 24 25 26 Class 3 grounding (grounding resistance 100 or less) *4 MAINT ALM FAIL CONT IN ANLG OUT 1 ANLG OUT 2 + - + - + - 1 2 3 4 5 6 Contact input (range selection for Hydrogen purity meter) *9 Isolated output signal, 4 to 20 ma DC Load resistance: 600 or less *7 (250 to 550 for Brain communication) Isolated output signal, 4 to 20 ma DC Load resistance: 600 or less *7 Pressure transmitter SPAN/FUNC 7 SNSR + *3 PWR 8 ZERO/SEL GAS - - SNSR + 9 Case grounding terminal L or + INP - 10 + N or - DET + 11 INP - 12 *2 Case grounding 13 terminal SHIELD - 1 2 + Case grounding terminal GD40 detector *1: Power supply Use a two-conductor cable with an OD of 8 to 16 mm. *2: Connection to the detector a. Use a two-conductor shielded cable with an OD of 8 to 16 mm. In addition, the go-and-return resistance must be 50 or less (for conductors with a cross sectional area of 1.25 mm 2 and a length no greater than 1.4 km). b. Be sure to ground the two-conductor shielded cable at either end of the shield. If an unusual phenomenon occurs due to noise, increase the countermeasures against noise. (For example, ground the detector body or use a double-shielded cable. If a double-shielded cable is used, ground shields of each conductor on either side of the cable. Ground the end of the outer shield on the detector side to the case of the detector and connect that end on the converter side to terminal 13.) See the Instruction Manual for more precise instructions on cable installation. c. Terminal 13 is for the detector only. *3: Connection to the pressure transmitter a. Use a two-conductor shielded cable with an OD of 8.5 to 11 mm. In addition, the go-and-return resistance must be 50 or less (for conductors with a cross sectional area of 1.25 mm 2 and a length no greater than 1.4 km). b. Be sure to ground the two-conductor shielded cable at either end of the shield. *4: Be sure to ground the case of the converter. *5: The contacts for the contact outputs are all dry contacts whose NO/NC state can be freely set except for the FAIL contact which is an NC contact and cannot be freely set. Their contact rating is 250 V AC, 3 A or 30 V DC, 3 A each. *6: If the detector is to be installed and used in a hazardous area, be sure to implement class 1 grounding work (grounding resistance is 10 or less). In addition, the grounding point of class 1 grounding must be located in a non-hazardous area. *7: Use a two-conductor shielded cable with an OD of 8 to 16 mm for any output signal. Be sure to ground the two-conductor shielded cable at either end of the shield. *8: Terminal 26 is connected to the case-grounding terminal. *9: For hydrogen purity meter, the contact input is used for range selection. Open: Concentration measurement for air in carbon dioxide Close: Concentration measurement for hydrogen in carbon dioxide NOTE ; The following cable with an OD size between instruments is used. Instrument Converter GD402R Expilosion-proof GD402G Non-Expilosion-proof Detector GD40 10 to 13.5 10 to 12 Pressure transmitter EJA310 8.5 to 11 GD402T, V Converter and GD40R, V Detector is no cable gland included. (The outside diameter of the cable is chosen by cable gland to use.) Output signal 8 to 16 6 to 12 Class 1 grounding (grounding resistance 10 or less) *6 Contact input/output 8 to 16 6 to 12 *10: GD402V, GD40V; All wiring shall comply with Canadian Electrical Code and Local Electrical Codes. GD402T, GD40T; All wiring shall comply with National Electrical Code and ANSI/NFPA70 and Local Electrical Codes.

8 EXTERNAL VIEWS AND DIMENSIONS 1. GD402G Converter (Non-Explosion-Proof): Unit: mm (in.) Weight: approximately 3 kg (6.6 pounds) Four holes, 6 mm (0.24) in dia., 8 mm (0.31) deep M6 80 (3.1) 144 (5.7) 80 (3.1) 144 (5.7) 23 (0.9) 112 (4.4) Cable inlet (21 mm (0.9) in dia.) Compatible with a Pg13.5 cable gland 36 (1.4) 38 (1.4) 36 36 (1.4) (1.4) Grounding terminal (4 mm (0.16) screws) Cable gland Connection Pressure transmitter A, B Analog output Contact Input C Detector D, E Contact Output F Power Supply

9 2. Pipe and Wall-Mounting Hardware (Optional) Hardware for Pipe Mounting: /U 188 (7.4) Unit: mm (in.) Weight: approximately 3 kg (6.6 pounds) Four holes, 6 mm (0.2) in dia. 50 (2) Mounting pipe of JIS 50 A nominal size (60.5 mm in outer dia.) Optional hardware 135 (5.3) 13 (0.51) 224 (8.8) Optional hardware Three holes, 10 mm (0.4) in dia. 70 (2.8) 100 (4) 23 (0.9) 100 (4) +2 139 0 (5.47 +0.08 ) 0 35 (1.4) 174 (6.9) 200 (7.9) 100 Hardware for Wall Mounting: /U Four holes, 6 mm (0.2) in dia. 224 (8.8) 15 (0.6) Hardware for Panel Mounting: /PA 12 mm (0.5) maximum (panel thickness) Four holes, 6 mm (0.2) in dia. Weight: approximately 3 kg (6.6 pounds) Optional hardware Dimensions of panel cutout 178 (7) +2 139 0 (5.47 +0.08) 0

10 3. GD402T, V, R Converter (Explosion-proof) Unit: mm (in.) Weight: approximately 15 kg (33.1 pounds) Approx. 212 (8.3) in dia. Approx. 200 (7.9) Approx. 209 (8.2) Approx. 182 (7.2) Approx. 173 (6.8) A Approx. 36 (1.4) 140 (5.5) Approx. 242 (9.5) Side view from arrow A direction Cable glands not included 24 (0.9) 200 (7.9) Mounting pipe of JIS 50 A nominal size (60.5 mm (2.4) in outer dia.) Pipe-mounting hardware Two holes, 8 mm (0.3) in dia., one on each side (Used to fix the pipe-mounting hardware) 39 (1.5) A B C 54 (2.1) D E F Grounding terminal (5 mm (0.2) screw) 56 (2.2) 56 (2.2) Six wiring holes, G3/4 threaded (GD402R) 1/2NPT threaded (GD402V, T) Cable gland Connection A Power Supply B, C Contact Output D Detector E, F Pressure from Transmitter, Analog Output, Contact Input 2nd Edition 2000.05.10-00

11 4. Detector Unit Model GD40 - /EJAJ1, EJAF2, EJAF3, EJAF4 Unit: mm (in.) Weight: approximately 15 kg (27.8 pounds) GD40 Detector wiring port See Table Cable gland is included only in EJAJ1 (350 (13.8)) (120) EJA wiring port See Table Approx. 105 Four panel-mounting holes, 12 mm in diameter (93) Gas out See Table Approx. 26 35 85 (350 (13.8)) (35) 5 Gas in See Table Cable gland is included only in /EJAJ1 (196) (40 (1.6)) Option code GD40 wiring EJA wiring Gas out/in /EJAJ1 G1/2 G1/2 Rc1/4 /EJAF2 1/2NPT 1/2NPT 1/4NPT /EJAF3 1/2NPT 1/2NPT 1/4NPT /EJAF4 1/2NPT 1/2NPT 1/4NPT

12 5. GD40 Detector Hardware for Pipe Mounting: GD 40 Approx. 191 (7.5) Approx. 92 (3.6) Approx. 264 (10.4) Approx. 193 (7.6) Grounding terminal (3 mm (0.11) screw) Pipe-mounting hardware Wiring hole, GD40R: G1/2 GD40V: 1/2NPT GD40T: 1/2NPT GD40G: 1/2NPT Approx. 117 (4.6) Sample gas inlet GD40R: Rc1/4 GD40V: 1/4NPT GD40T: 1/4NPT GD40G: 1/4NPT Mounting pipe (JIS 50 A (60.5 mm in outer dia.) nominal size) Sample gas outlet GD40R: Rc1/4 GD40V: 1/4NPT GD40T: 1/4NPT GD40G: 1/2NPT Note: Cable gland is included only in GD40R.

13 GD402 Gas Density Meter Inquiry Form 1. General Customer : Tag No. : Plant name : Measuring point : Purpose of use : Monitoring Control Alarm Transaction Other Quantity to be measured: Density, Specific gravity, Moleular weight, Caloric value BTU, H2 in Air, Air in CO2 H2 in CO2, Concentration Measuring range : Document : English 2. Utilities and Installation Conditions Power supply : VAC % Hz % 24VDC Instrument air : Pressure psi, Pa Steam supply : Pressure psi, Pa Temperature C, F Cooling water : Pressure psi, Pa Temperature C, F Distance between gas sampling point and analyzer: m 3. Process Conditions Gas composition Pressure at gas sampling point : psi, kpa Temperature at gas sampling point : C, F Quantity of dust : g/m 3 Moisture : vol% : C, Fsaturated Corrosiveness : No Yes 4. Installation Conditions Temperature: C Maximum, F Minimum, Corrosive gas : No Yes Vibration : No Yes Location : Indoors Outdoors 5. Other Specific Items 6. Scope of Estimation Converter units Non-explosion-proof Explosion-proof Detector units Gas sampling system (special order) sets Others sets Gas composition NOR Concentration (vol%) MAX MIN Density 1 2 3 4 5 6 7 8 9 10 11 12 Notes 2nd Edition 2000.05.10-00

14 Measurement Principle Multi-mode self-oscillation system This system is based on the characteristic that the resonance frequency of a thin-film cylindrical vessel varies with the density of ambient gas. When two types of frequency are supplied to the same cylinder and the ratio of the resonance frequencies of the cylinder is measured, the measured frequencies are a function of the density. The density can therefore be measured without the effect of disturbance. O-ring RTD O-ring GAS OUT GAS IN O-ring Resonator O-ring Detector Construction YOKOGAWA ELECTRIC CORPORATION World Headquarters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN Tel.:+81-422-52-5617 Fax.:+81-422-52-0622 World Sales Headquarters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN Tel.:+81-422-52-6339 Fax.:+81-422-52-6552 YOKOGAWA ELECTRIC ASIA PTE. LTD. 11 Tampines Street 92, SINGAPORE 528872 Tel.:+65-783-9537 Fax.:+65-786-2606 YOKOGAWA EUROPE B.V. P.O.Box 163,3800 AD Amersfoort, Vanadiumweg 11, 3812 PX Amersfoort, THE NETHERLANDS Tel.:+31-33-4-641611 Fax.:+31-33-4-641610 YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan, GA 30265-1040, U.S.A. Tel.:+1-770-254-0400 Fax.:+1-770-254-0928 YOKOGAWA AMERICA DO SUL S.A. Avenida Jurua, 149 Alphaville CEP 06455-010 Barueri Sao Paulo BRAZIL Tel.:+55-11-7295-6282 Fax.:+55-11-421-3538 Represented by: KE-1 Subject to change without notice. Printed in Japan, 005(YG)