NS Series Network Sensors

Similar documents
NS Series Network Sensors

NS Series Network Sensors

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Surface-Mounted NS Series Network Sensors without LCD

Facility Explorer One-to-One Wireless Room Sensing System

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TEC2100 Series Networked Thermostats

TEC210x-2 Series Networked Thermostats

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

TEC1100 Series Thermostats

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

P266 Series Single-Phase Condenser Fan Speed Control

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

CD-Px Series Duct Mount CO 2 Transmitters

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

F261 Series Fluid Flow Switches

Document # R01

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Installation Instructions

Document Introduction Annex A - Protocol Implementation Conformance Statement (Normative) Product Description... 4

T500 Series Non-Programmable Thermostats

MR3CCUHV Temperature/Defrost Control

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control

T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs

TM-3100 Series Room Temperature Sensor

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

TEC Networked Multi-Stage Thermostat

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

TEC and TEC PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers

TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TEC and TEC PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers

TEC21x7-2 Series N2 Networked Thermostat Controllers with Two Outputs

TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No , Rev. C

T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Johnson Controls Fan Coil Units and Direct Digital Controls

TEC and TEC PIR N2 Networked Single-Stage Thermostat Controllers

TEC Networked Single-Stage Thermostat

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

T600HCx-3 Single-Stage Thermostats

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Document # R00

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Fume Hood Operating Display Panel

Accuracy by Design Products for the HVAC Professional

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

TEC1100 Series Thermostat

3M Benchtop Air Ionizer 963E. User s Guide

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

WRS-TTx Series Wireless Room Temperature Sensors

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Location Requirements

LORAIN CIP 4890/48120 DC Power System

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

LORAIN CSP DC Power System

SEE DISCLAIMER ON REVERSE

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

safety & regulatory information

ETAF Series VDC Fan output LCD Fan Coil Thermostat

Net/X US32 Universal Setback Communicating Thermostat

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

ET10 Series Stand-alone LCD Fan Coil Thermostat

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

BAC-4000 Series AppStat

Installation Instructions. Applications. North American Emissions Compliance. Installation. Part No , Rev. Issued February 8, 2010

S541.RF 4G Product Guide

Room thermostats with LCD for wall mounting

Allure EC-Smart-Air Series Communicating sensors

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

CONTENTS. Installation Guide. VT7200 Series

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

T8000 Series T8600 MODBUS Touch Screen Thermostat

TB7200 Series Communicating Zone Thermostats

RLD-H10P Refrigerant Leak Detector

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

RLD-H10G Refrigerant Leak Detectors

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Light Level Detector, Surface Mount 5754PE. Installation Instructions

HEAT COOL. Meets Commercial California Title 24

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Predator Controller Hardware Family

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Isolated Thermocouple Module

ALTAIR 5X Multigas Detector Product Specification

York 25-Ton VAV Rooftop Unit

Transcription:

NS Series Network s Bulletin AHx7x0x-x, APx7x0x-0, ATx700x-x, BCN7004-x, BHx7x0x-0, BPx700x-0, BTx700x-x, DTN70x3-0, FTN7003-x, MHL700x-0, MNN700x-0, MTx700x-0 No. LIT-12011574 Issued March 4, 2013 Supersedes April 25, 2012 Refer to the QuickLIT website for the most up-to-date version of this document. The NS Series Network offering includes NS Series Network Zone s and NS Series Network Discharge Air s. The NS Series Network s are designed to function directly with Metasys system Field Equipment Controllers (FECs), Input/Output Modules (IOMs), Variable Air Volume (VAV) Modular Assembly (VMA16) controllers, and Facility Explorer FX-PC Series Programmable Controllers (FX-PCGs, FX-PCVs, and FX-PCXs). The majority of NS Series Network Zone s monitor room temperature; however, options are available to also monitor zone humidity, carbon dioxide (CO 2 ), local temperature setpoint adjustments, and other variables. This data is transmitted to a controller on the Actuator (SA) Bus. Some models of NS Series Network Zone s include an onboard passive infrared () occupancy sensor that detects motion to determine if a space is occupied. This feature maximizes up to 30% energy savings in high-energy usage environments such as schools, dormitories, offices, hospitals, and hotels by adjusting the temperature of the space based on the occupancy status. In addition, the occupancy sensor facilitates trending of floor space usage in these environments. The NS Series Network Zone s include models with a temperature setpoint dial and Liquid Crystal (LCD) that allows occupants to view the zone temperature, Relative Humidity (RH), and view and adjust the zone temperature setpoint. Some temperature and humidity models include a push button to toggle between temperature and RH on the display. These models also have the capability to set the desired default display to either temperature or RH. A fan mode push button is included to set the desired fan speed (AUTO-OFF-low-medium-high). An occupancy override function allows the user to signal the controller that the zone is occupied to override the scheduled mode. Some models have DIP switches to set a unique address for applications that require multiple sensors. For communication wiring flexibility, the wires connecting the network zone sensor to a controller can be terminated using a modular jack or screw terminals. Figure 1: NS Series Network s Each network sensor includes an SA Bus access port to allow accessories to access the SA Bus. This plug allows accessories to service or commission the connected controller or gain access to any other controller on the same Field Controller (FC) Bus. The NS Series Network Zone offering includes models that can be surface mounted, vertical wallbox mounted, or flush mounted to meet the requirements of the specific application. The NS Series Network Discharge Air s monitor the duct temperature, typically at the discharge of the VAV box, and transmit this data to a local controller on the SA Bus using the 10 ft (305 cm) wiring lead included with the unit. The 10 ft (305 cm) wiring lead consists of four 22 AWG (0.6 mm) trade size color-coded wires encased in a plenum-rated jacket. Each of the wires is stripped and tinned for easy connection to the SA Bus screw terminal block. The NS Series Network Discharge Air s are available with either a 4 or 8 in. (102 or 203 mm) temperature probe. All models include DIP switches for applications requiring multiple discharge air sensors, each with a unique DIP switch address. NS Series Network s Bulletin 1

Table 1: Features and Benefits Features BACnet Master-Slave/Token-Passing (MS/TP) Protocol Communication Backlit LCD Available on Some Models Simple Adjustment Available on Some Models Onboard Available on Some Models Temporary Available on Some Models Field-Selectable Default Setting on Some Models Fahrenheit/Celsius (F/C) Button Available on Some Models Benefits Provides compatibility with Metasys system field controllers and Facility Explorer programmable controllers in a proven communication network. Provides real-time status of the environment with backlighting activated during user interaction. Enables you to change the setpoint with the turn of a dial. Maximizes up to 30% energy savings in high-energy usage environments, and facilitates trending of floor space usage. Provides a timed override command, which temporarily initiates an alternate mode. Allows you to toggle between temperature and RH on the display, and set the desired default for continuous viewing. Toggles the display temperature between degrees Celsius and degrees Fahrenheit. Ordering Information Table 2 through Table 7 list the various NS Series Network Zone s available, and Table 8 lists the various NS Series Network Discharge Air s available. IMPORTANT: The NS Series Network is intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the network sensor could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the network sensor. Repair Information If the NS Series Network Zone or the NS Series Network Discharge Air fails to operate within its specifications, replace the unit. For a replacement sensor, contact the nearest Johnson Controls representative. Table 2: Network Zone Ordering Information Only Models (Part 1 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control ATA7001-0 ATA7002-0 ATA7003-0 ATB7001-0 ATB7002-0 Override Button, Terminals (ST) or Modular 80 x 80 SM Yes Yes Set Yes, No No No MJ No No 80 x 80 SM Yes Yes Set Yes, No No No ST No No 80 x 80 SM Yes Yes Set Yes, No No No ST Yes No 80 x 80 SM Yes Yes Set Yes, No Yes No MJ No No 80 x 80 SM Yes Yes Set Yes, No Yes No ST No No VAV Balancing Feature 2 NS Series Network s Bulletin

Table 2: Network Zone Ordering Information Only Models (Part 2 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control ATB7003-0 ATC7001-0 ATC7002-0 ATD7001-0 ATD7002-0 ATF7001-0 ATF7002-0 ATN7001-0 ATN7001-2 ATN7003-0 ATN7003-2 ATP7001-0 ATP7001-2 ATP7002-0 ATP7002-2 ATP7003-0 ATP7003-2 ATV7001-0 ATV7002-0 BTB7001-0 BTB7001-2 BTB7002-0 BTB7003-0 BTB7003-2 Override Button, Terminals (ST) or Modular 80 x 80 SM Yes Yes Set Yes, No Yes No ST Yes No 80 x 80 SM Yes Yes Set Yes, No No Yes MJ No No 80 x 80 SM Yes Yes Set Yes, No No Yes ST No No 80 x 80 SM Yes Yes Set Yes, No Yes Yes MJ No No 80 x 80 SM Yes Yes Set Yes, No Yes Yes ST No No 80 x 80 SM Yes Yes W/C Yes, No Yes No MJ No No 80 x 80 SM Yes Yes W/C Yes, No Yes No ST No No 80 x 80 SM Yes No N/A No, No No No MJ No No 80 x 80 SM No No N/A No, No No No MJ No No 80 x 80 SM Yes No N/A No, No No No ST Yes No 80 x 80 SM No No N/A No, No No No ST Yes No 80 x 80 SM Yes No W/C Yes, No No No MJ No No 80 x 80 SM No No W/C Yes, No No No MJ No No 80 x 80 SM Yes No W/C Yes, No No No ST No No 80 x 80 SM No No W/C Yes, No No No ST No No 80 x 80 SM Yes No W/C Yes, No No No ST Yes No 80 x 80 SM No No W/C Yes, No No No ST Yes No 80 x 80 SM Yes Yes Set Yes, No Yes No 1 MJ No Yes 80 x 80 SM Yes Yes Set Yes, No Yes No 1 ST No Yes 120 x 80 WB, SM Yes Yes Set Yes, No Yes No MJ No No 120 x 80 WB, SM No Yes Set Yes, No Yes No MJ No No 120 x 80 WB, SM Yes Yes Set Yes, No Yes No ST No No 120 x 80 WB, SM Yes Yes Set Yes, No Yes No ST Yes No 120 x 80 WB, SM No Yes Set Yes, No Yes No ST Yes No VAV Balancing Feature NS Series Network s Bulletin 3

Table 2: Network Zone Ordering Information Only Models (Part 3 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control 120 x 80 WB, SM Yes Yes W/C Yes, No Yes No MJ No No BTF7001-0 120 x 80 WB, SM Yes Yes W/C Yes, No Yes No ST No No BTF7002-0 120 x 80 WB, SM Yes No N/A No, No No No MJ No No BTN7001-0 120 x 80 WB, SM No No N/A No, No No No MJ No No BTN7001-2 120 x 80 WB, SM Yes No N/A No, No No No ST Yes No BTN7003-0 120 x 80 WB, SM No No N/A No, No No No ST Yes No BTN7003-2 120 x 80 WB, SM Yes No W/C Yes, No No No MJ No No BTP7001-0 120 x 80 WB, SM No No W/C Yes, No No No MJ No No BTP7001-2 120 x 80 WB, SM Yes No W/C Yes, No No No ST No No BTP7002-0 120 x 80 WB, SM No No W/C Yes, No No No ST No No BTP7002-2 120 x 80 WB, SM Yes No W/C Yes, No No No ST Yes No BTP7003-0 120 x 80 WB, SM Yes Yes Set Yes, No Yes No 1 MJ No Yes BTV7001-0 120 x 80 WB, SM Yes Yes Set Yes, No Yes No 1 ST No Yes BTV7002-0 120 x 80 WB, SM Yes Yes Set No, Yes Yes No MJ No No MTB7001-0 120 x 80 WB, SM Yes Yes Set No, Yes Yes No ST No No MTB7002-0 120 x 80 WB, SM Yes No N/A Yes, Yes No No MJ No No MTL7001-0 MTL7002-0 120 x 80 WB, SM Yes No N/A Yes, Yes No No ST No No 1. In the VAV balancing models, the fan control button is replaced by a light bulb button used in the VAV balancing process. Table 3: Network Zone Ordering Information and Humidity Models without RH (Part 1 of 2) Johnson Controls Humidity Element Accuracy LCD, RH Override Button, Terminals (ST) or Modular F/C Override Scale Button, Toggle Terminals (ST) or Modular AHA7001-0 80 x 80 SM Yes Yes, No 3% Set Yes, No No MJ No AHA7002-0 80 x 80 SM Yes Yes, No 3% Set Yes, No No ST No AHB7001-0 80 x 80 SM Yes Yes, No 3% Set Yes, No Yes MJ No VAV Balancing Feature 4 NS Series Network s Bulletin

Table 3: Network Zone Ordering Information and Humidity Models without RH (Part 2 of 2) Johnson Controls Humidity Element Accuracy AHB7002-0 80 x 80 SM Yes Yes, No 3% Set Yes, No Yes ST No AHB7003-0 80 x 80 SM Yes Yes, No 3% Set Yes, No Yes ST Yes AHN7001-0 80 x 80 SM Yes None 3% N/A No, No No MJ No AHN7001-2 80 x 80 SM No None 3% N/A No, No No MJ No AHP7001-0 80 x 80 SM Yes None 3% W/C Yes, No No MJ No APA7001-0 80 x 80 SM Yes Yes, No 2% Set Yes, No No MJ No APA7002-0 80 x 80 SM Yes Yes, No 2% Set Yes, No No ST No APB7001-0 80 x 80 SM Yes Yes, No 2% Set Yes, No Yes MJ No APB7002-0 80 x 80 SM Yes Yes, No 2% Set Yes, No Yes ST No APB7003-0 80 x 80 SM Yes Yes, No 2% Set Yes, No Yes ST Yes BHB7001-0 120 x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes MJ No BHB7002-0 120 x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes ST No BHB7003-0 120 x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes ST Yes BHN7001-0 120 x 80 WB, SM Yes None 3% N/A No, No No MJ No BHN7001-2 120 x 80 WB, SM No None 3% N/A No, No No MJ No BHP7001-0 120 x 80 WB, SM Yes None 3% W/C Yes, No No MJ No BPB7001-0 120 x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes MJ No BPB7002-0 120 x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes ST No BPB7003-0 120 x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes ST Yes MHL7001-0 120 x 80 WB, SM Yes No, No 3% N/A Yes, Yes No MJ No MHL7002-0 120 x 80 WB, SM Yes No, No 3% N/A Yes, Yes No ST No Table 4: Network Zone Ordering Information and Humidity Models with or RH (Field-Selectable Default ) Humidity Element Accuracy Override Button F/C Scale Toggle LCD, RH LCD, RH F/C Override Scale Button, Toggle Terminals (ST) or Modular Terminals (ST) or Modular AHR7101-0 80 x 80 SM Yes, Yes 3% Set Yes Yes MJ No AHR7102-0 80 x 80 SM Yes, Yes 3% Set Yes Yes ST No AHR7103-0 80 x 80 SM Yes, Yes 3% Set Yes Yes ST Yes APR7101-0 80 x 80 SM Yes, Yes 2% Set Yes Yes MJ No APR7102-0 80 x 80 SM Yes, Yes 2% Set Yes Yes ST No BHR7101-0 120 x 80 WB, SM Yes, Yes 3% Set Yes Yes MJ No BHR7103-0 120 x 80 WB, SM Yes, Yes 3% Set Yes Yes ST Yes NS Series Network s Bulletin 5

Table 5: Network Zone Ordering Information Motion Detection Only Models (No or Humidity Sensing) LCD (WB), or Terminals (ST), or Modular MNN7001-0 120 x 80 WB, SM No Yes MJ No MNN7003-0 120 x 80 WB, SM No Yes ST Yes Table 6: Network Zone Ordering Information CO 2 Models LCD (mm) (WB), or CO 2 Measurement Range Johnson Controls Terminals (ST), or Modular ing BCN7004-0 120 x 80 WB, SM No 0 to 2,000 ppm Yes ST, MJ DIP Switch (212 to 219) BCN7004-2 120 x 80 WB, SM No 0 to 2,000 ppm No ST, MJ DIP Switch (212 to 219) Table 7: Network Zone Ordering Information Flush-Mount Only Models Mounting LCD FTN7003-0 FTN7003-2 Faceplate Dimensions, 4-1/2 in. x 2-3/4 in. (114 mm x 70 mm) 4-1/2 in. x 2-3/4 in. (114 mm x 70 mm) Measurement Range Flush-Mount No 32.0 F/0.0 C to 104.0 F/40.0 C Flush-Mount No 32.0 F/0.0 C to 104.0 F/40.0 C Johnson Controls Table 8: Network Discharge Air Ordering Information Dimensions, HeightxxDepth Probe Length 10 ft (305 cm) Wiring Lead Included DTN7043-0 DTN7083-0 3 in. x 3 in. x 2 in. (76 mm x 76 mm x 51 mm) 3 in. x 3 in. x 2 in. (76 mm x 76 mm x 51 mm) ing Technical Specifications NS Series Network Zone s Only Models and and Humidity Models (Part 1 of 2) Supply Voltage Current Consumption ing Yes No Terminal Block Terminal Block DIP Switch (200 to 203) DIP Switch (200 to 203) ing 4 in. (102 mm) Yes Terminal Block DIP Switch (204 to 211) 8 in. (203 mm) Yes Terminal Block DIP Switch (204 to 211) 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Only Models with LCD : 21 ma Maximum (Non-transmitting) Only Models without LCD : 13 ma Maximum (Non-transmitting) and Humidity Models with LCD : 25 ma Maximum (Non-transmitting) and Humidity Models without LCD : 17 ma Maximum (Non-transmitting) Modular Jack or Terminal Block AHx7003-0, APB7003-0, ATx7003-0, BHx7003-0, BPB7003-0, BTB7003-0, BTN7003-0, and BTP7003-0 Models: DIP Switch Set from 200 to 203; Factory Set at 203 All Other Models: Fixed of 199 6 NS Series Network s Bulletin

NS Series Network Zone s Only Models and and Humidity Models (Part 2 of 2) Wire Communication Rate Mounting Measurement Range Humidity Measurement Range Type Humidity Type Resolution (Models with LCD) Accuracy Humidity Element Accuracy Time Constant Default Adjustment Range Motion Detection (Models with ) Ambient Conditions Compliance BACnet International United States Canada Europe Australia and New Zealand Accessory (Order Separately) Shipping Weight Modular Jack Models: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block Models: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps : 80 x 80 mm or : 120 x 80 mm 32.0 F/0.0 C to 104.0 F/40.0 C Full Range: 0 to 100% RH Calibrated Range: 10 to 90% RH Local Platinum Resistance Detector (RTD) Thin Film Capacitive ±0.5F /±0.5C ±1.0F /±0.6C APx700x-0 and BPB700x-0 Models: ±2% RH for 20 to 80% RH; ±4% RH for 10 to 20% and 80 to 90% RH AHx700x-0, BHx700x-0, and MHL700x-0 Models: ±3% RH for 20 to 80% RH; ±6% RH for 10 to 20% and 80 to 90% RH 10 Minutes Nominal at 10 fpm Airflow With LCD : 50.0 F/10.0 C to 86.0 F/30.0 C in 0.5 Increments Without LCD : ±5.0F /±3.0C Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m); Based on a Clear Line of Sight Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage with LCD : -4 to 140 F (-20 to 60 C); 5 to 95% RH, Noncondensing Storage without LCD : -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Smart (B-SS) Note: Excludes the ATV700x-0 and BTV700x-0 models. UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. C-Tick Mark, Australia/NZ Emissions Compliant WALLPLATE-0: Adapts an 80 x 80 mm NS Series Network Zone to a Standard 80 x 120 mm Wallbox Axx7xxx-0 Models: 0.20 lb (0.09 kg) Bxx7xxx-0 and Mxx700x-0 Models: 0.25 lb (0.11 kg) NS Series Network s Bulletin 7

NS Series Network Zone s Motion Detection Only Models (No or Humidity Sensing) Supply Voltage 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Current Consumption 13 ma Maximum (Non-transmitting) Modular Jack or Terminal Block ing DIP Switch Set from 200 to 203; Factory Set at 203 (MNN7003-0 Model) Wire Modular Jack Model: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block Model: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Mounting or : 120 x 80 mm Motion Detection Ambient Conditions Compliance Shipping Weight BACnet International United States Canada Europe Australia and New Zealand Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m); Based on a Clear Line of Sight Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Smart (B-SS) UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. C-Tick Mark, Australia/NZ Emissions Compliant 0.25 lb (0.11 kg) 8 NS Series Network s Bulletin

NS Series Network Zone CO 2 Models Supply Voltage Non-isolated: 20 to 30 VAC (18 to 30 VDC), Class 2 or Safety Extra-Low Voltage (SELV) Isolated: 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Current Consumption Non-isolated: 22 ma Average at 24 VAC; 28 ma Average at 24 VDC Isolated: 5 ma Maximum, Non-transmitting (From SA Bus) Power Consumption Non-isolated: Less Than 0.7 W Average Non-isolated Supply: Terminal Block SA Bus: Modular Jack or Terminal Block ing DIP Switch Set from 212 to 219; Factory Set at 212 Wire Modular Jack: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps CO 2 Measurement Range 0 to 2,000 ppm CO 2 Sensing Accuracy Plus or Minus the Sum of 50 ppm and 3.0% of the CO 2 Reading at 77 F (25 C) and 978 hpa or an Altitude of 1,000 ft/300 m Note: All accuracy specifications reflect the testing of the device using high-grade certified gases. This device is intended for an altitude range of 0 ft/0 m to 2,000 ft/600 m above sea level without compensation. Dependence of Output: -0.35% of the CO 2 Reading per 1.8F /1C Typical Pressure Dependence of Output: +0.15% of the CO 2 Reading per 1 hpa Typical CO 2 Sensing Resolution 1 ppm CO 2 Sensing Response Time 1 Minute (0 to 90%) CO 2 Sensing Warm-Up Time Less Than 1 Minute; Less Than 10 Minutes for Full Accuracy CO 2 Sensing Long-Term Stability Less Than ±100 ppm Over 5 Years Mounting or : 120 x 80 mm Ambient Conditions Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point; 700 to 1,200 hpa Storage: -40 to 158 F (-40 to 70 C); 0 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Smart (B-SS) International United States UL Listed, File E107041 CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight 0.35 lb (0.16 kg) NS Series Network s Bulletin 9

NS Series Network Zone Flush-Mount Only Models Supply Voltage Current Consumption 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) 12 ma Maximum (Non-transmitting) per Flush-Mount Network Terminal Block Note: Wire leads are field supplied and are not tinned. ing DIP Switch Set from 200 to 203; Factory Set at 203 Wire 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended; 10 ft (304.8 cm) Wiring Lead Included with the Unit Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Measurement Range 32.0 F/0.0 C to 104.0 F/40.0 C Type Local Platinum Resistance Detector (RTD) Accuracy ±1.0F /±0.6C Ambient Conditions Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Smart (B-SS) International United States UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight 0.25 lb (0.11 kg) 10 NS Series Network s Bulletin

NS Series Network Discharge Air s Supply Voltage Current Consumption 9.8 to 16.5 VDC; 15 VDC Nominal 12 ma Maximum (Non-transmitting) per Discharge Air Four Color-d Wiring Leads, Stripped and Tinned; Factory-Installed at the Discharge Air Terminal Block ing DIP Switch Set from 204 to 211; Factory Set at 204 Wire 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended; 10 ft (305 cm) Wiring Lead Included with the Unit Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Mounting Duct-: 4 or 8 in. (102 or 203 mm) Probe Length Measurement Range 14 F/-10 C to 140 F/60 C Type Local Platinum Resistance Detector (RTD) Accuracy ±1.0F /±0.6C Ambient Conditions Operating: 14 to 140 F (-10 to 60 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Smart (B-SS) International United States UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight DTN7043-0: 1.15 lb (0.52 kg) DTN7083-0: 1.17 lb (0.53 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. United States Emissions Compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case users will be required to correct the interference at their own expense. Canadian Emissions Compliance This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2013 Johnson Controls, Inc. NS Series Network s Bulletin 11 Published in U.S.A. www.johnsoncontrols.com