Thermo-hygrometer. Use and maintenance manual Update 3 Apr INSTUM_01378 Pag. 1/8

Similar documents
EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

MP 601A Humidity Probe INSTRUCTION MANUAL

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

testo 316-EX gas leak detector Instruction manual

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric)

HYGROMER - MP 400 A Meteorology probe

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

HYGROMER MP 100 A Meteorology probe

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Alarm system For oil-water separator

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

ATM Lighting sp. z o.o

CMT MANUAL 6. NMC SENSORS

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

HYGROPHIL H process hygrometer

Flame Rod Manual. Publication Rev A

Heater Core And Evaporator Core Housing

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

Certificate of Compliance

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ATM Lighting sp. z o.o

Certificate of Compliance

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

OilSET-1000 (12 VDC)

Quick Start Guide For the

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

MBCE-110/230UV Flame Sensor Module

SIMRAD GD10PE IR GAS DETECTOR

Familiarization with the Training System

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

COMPACT FLAME CONTROLLER CFC 2000

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Snifter ATEX22 VERSION. User Manual. Distributor

Using the Model 1500 Portable Chilled Mirror Hygrometer

Manual Hygrometer PCE-555

Snifter. User Manual. Distributor

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Aerosol Inlet Dryer. User s manual. Part Number: AE33-AEDN. User's manual Version 1.5 December /30

Outside Humidity and Temperature Sensor

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

PM-200 Power Module Operating Instructions

Passive infrared ceiling sensor

COMPACT FLAME CONTROLLER CFC 1000

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

S304 and S305 Dust Emission Monitors. User Manual. Distributor

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

MBCE-110/230FR Flame Sensor Module

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

DEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications

Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Unit THE NATURE OF HEAT

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Eclipse Self-Check UV Scanner

INSTRUCTION MANUAL (ATEX / IECEx)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

EC3-X33 Stand-alone Superheat Controller Technical Data

MBCE-110/230FR Flame Sensor Module

MODEL RWM RADIATION WASTE MONITOR LUDLUM MODEL RWM RADIATION WASTE MONITOR INSTALLATION MANUAL

Software Version 2.01 LEVEL MONITOR MODEL 220

Laser Distance Sensor Type M Analog-Output

3.4 Humidity. Types of instruments

Dry Contact Probe DCP (#30008)

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Remote Relay Module (RRM)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Operating Manual MS220KA and MSR220KA

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

OPTISENS TUR 2000 Technical Datasheet

HUM-M2 Humidity Sensor Module Description

ECOLOG Data logger series we prove it.

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Transcription:

Thermo-hygrometer DMA867 and DMA875 Use and maintenance manual Update 3 Apr 2014 INSTUM_01378 Pag. 1/8

Index 1 Description... 3 1.1 Main features... 3 1.2 Models and technical specifications... 3 2 Product installation... 4 2.1 General safety rules... 4 2.2 How to choose the survey site... 4 2.3 Mechanical mounting... 5 2.4 Dip-switches configuration... 5 2.5 Electrical connection... 5 3 Application note... 6 3.1 Measuring humidity in high temperature environments... 6 4 Diagnostics... 6 4.1 External visual check... 6 4.2 Internal visual check... 6 5 Maintenance... 7 5.1 Cleaning the antiradiant shield... 7 5.2 Cleaning the measuring elements and the porous filter... 7 6 Accessories / Spare parts... 7 7 Disposal... 8 8 How to contact LSI LASTEM... 8 INSTUM_01378 Pag. 2/8

1 Description 1.1 Main features Thermohygrometers DMA867 and DMA875 are instruments to measure environmental temperature, relative humidity and dew point. The determination of dew point takes place according to the formulations specified by ISO 7726. The measuring element is housed inside a radiation shield, available with both natural and forced ventilation, to achieve measuring conditions equivalent to a Stevenson shelter. The measurement system is made up of a sensor, the radiation shield in natural or forced ventilation and the connection cable type DWA. 1.2 Models and technical specifications Order numb. DMA867 DMA875 Measurements C, RH% Hydrometric output Programmable: RH% or Dew Point Output 2 x 0/4 20 ma Power consumption 3 W 1 W Ventilation Forced Natural Common features Temperature Principle Pt100 1/3 DIN B Measuring range Programmable: -30 70 C, -50 50 C, -50 100 C Uncertainty 0.2 C (@0 C) Resolution 0.04 C Relative humidity Response time (T90) Principle 20 s Capacitive Measuring range 0 100 % Uncertainty ±1.5% RH (@5 95 %) Response time (T90) 1 min General Power supply 10 30 Vac/Vdc information Connector 7 pin IP65 watertight connector Protection IP65 Electric protection/power supply Transzorb + Emifilter Operative temperature -40 C 80 C INSTUM_01378 Pag. 3/8

2 Product installation 2.1 General safety rules Please read the following general safety rules in order to avoid injuries to people and prevent damages to the product or to possible other products connected with it. In order to avoid any damages, use this product exclusively according to the instructions herein contained. The installation and maintenance procedures must be carried-out only by authorized and skilled service personnel. Power the instrument in a suitable manner. Pay attention and observe the power supplies like indicated for the model in your possession. Carry-out all connections in a suitable manner. Pay strict attention to the connection diagrams supplied with the instrument. Do not use the product in case of suspected malfunctions. In case of suspected malfunction, do not power the instrument and contact authorized technical support immediately. Do not set working the product in an explosive atmosphere. Before you carry-out any operation on electrical connections, power supply system, sensors and communication apparatus: Disconnect the power supply. Discharge the accumulated electrostatic discharges touching an earthed conductor or apparatus. 2.2 How to choose the survey site Select a site with conditions representative of the environment being examined. Thermohygrometers must be assembled in sites where the morphological conditions of the earth, the urban structures and the environmental conditions in general make them particularly representative of the general conditions in which the measurement is to be performed. It is important that there are no structures in the nearby areas which might radiate heat, such as cement floors, asphalt, walls, etc. The thermo-hygrometers should be installed at 1.5-2 m from the INSTUM_01378 Pag. 4/8

2.3 Mechanical mounting Fit the DYA049 or DYA051 supporting collar to the pole at the desired height, usually at 1,5-2 m, and tighten the screws using an allen key n. 6. Thermo-hygrometer DMA867-875 Use and maintenance manual Fix the sensor to the supporting collar by tightening the two bolts indicated with arrows in the picture. Connect the DWA cable to the sensor and to the data acquisition system according to drawing DISACC5901d. when a forced ventilation radiation shield is in use, feed the fan engine with a suitable power supply. 2.4 Dip-switches configuration The factory settings are: Electric output: 4 20 ma Hygrometric output: UR % Temperature range: -30 70 C To change the settings open the sensor box, set the dip-switches according to your needs (the arrangement of the dip-switches is shown inside the box cover and on the drawing DISACC5901d) and close the box. 2.5 Electrical connection Power the instrument according to the technical specifications. For optimal operation, ensure proper earthling of the power and communication lines. INSTUM_01378 Pag. 5/8

3 Application note 3.1 Measuring humidity in high temperature environments In very wet tropical areas, humidity values may acquire a very low dynamic range, close to saturation conditions and, at the same time, to have a low temperature dynamic range and very low wind speed values. In certain periods of the year, these conditions may occur even in milder areas for short periods of time. In such conditions, the hygrocapacitive element can get wet (from dew) and have no time to get dry and restore its measuring capacity. In this case, even if the humidity value decreases, the humidity measurement stabilizes to the saturation value or is at any rate underestimated. Two conditions may occur. The first one refers to every category of exchange type humidity sensor; the second one is typical of capacity-measurement humidity sensors: a) The layer of dew over the measuring element can reach 0,25 mm. Penman s theory states that 8 hours are needed for the layer of dew to evaporate (30 C, 80 RH% with no air speed), or 4 hours (30 C, 60 RH% with no air speed). These time periods can be shorter in case of forced ventilation (not less than 1.5 m/s). b) The manufacturers of hygrocapacitive elements inform that a persistent humidity level on the element could produce a secondary absorption phenomenon, as well as cause a temporary shift of the humidity measurement equal to about +6%. This error disappears when the element is exposed for some hours to lower humidity values. These considerations confirm that the hygrocapacitive element can be used when humidity values reach a sufficient dynamic range to enable the sensor adjustment based on the stress condition. 4 Diagnostics 4.1 External visual check 1. Check that the external anti-radiant shield is clean and with no dents (a suitably clean shield will have a higher reflecting capacity). 2. Check for the fan (in the forced ventilation models) proper operation. 4.2 Internal visual check Draw out the sensor from the shield and: 1. Check that the porous filter protecting the sensitive element is properly clean (see 5.2). 2. Check that the hygrocapacitive element is properly clean. Check for any presence of dust or dew on the capacitive plate (if possible also with the help of a magnifying lens). Check as well that contacts are free from oxidations. Do not touch the capacitive plate with your hands. If necessary, clean the element (see 5.2). INSTUM_01378 Pag. 6/8

5 Maintenance This sensor is a precision measurement apparatus. In order to maintain the specified measurement precision over the time, LSI LASTEM recommends check it periodically (at least twice a year); it is moreover suggested the replacement of the measure element according to the place of installation (in persistent conditions of high humidity, pollution, dust and chemical substances presence, the sensitive element deteriorate faster than the one placed in a location with less adverse conditions). It is, anyway, a good rule to replace the sensitive element at least once every two years. Please, remind that the sensitive element ML3015, when used, is no under guarantee. 5.1 Cleaning the antiradiant shield Clean the external anti-radiant shield with the aid of a small brush or a wet rag. 5.2 Cleaning the measuring elements and the porous filter 1. Disconnect the cable from the probe; 2. Unscrew the cable seals at the bottom and pull out the sensor from the shield; 3. Unscrew the filter; 4. Clean the filter with a cold air jet. 6 Accessories / Spare parts Code DYA049 DWA510 DWA525 DWA526 DWA527 ML3015 MM0315 MM0316 DZC301.S MG2251 Description Mast-mounting device for Ø45 65 mm pipe Cable L = 10 m Cable L = 25 m Cable L = 50 m Cable L = 100 m Sensitive element (spare part) Fan for forced ventilation shield DYA231 (12 Vdc) Fan for forced ventilation shield DYA232 (24 Vac) Calibration certificate 7 pin free female connector. INSTUM_01378 Pag. 7/8

7 Disposal This product is a device with high electronic content. In accordance with the standards of environmental protection and collection, LSI LASTEM recommends to handle this product as waste of electrical and electronic equipment (RAEE). For this reason, at the end of its life, the instrument must be kept apart from other wastes. LSI LASTEM is liable for the compliance of the production, sales and disposal lines of this product, safeguarding the rights of the consumer. Unauthorized disposal of this product will be punished by the law. 8 How to contact LSI LASTEM In case of problem contact the technical support of LSI LASTEM sending an e-mail to support@lsi-lastem.it, or compiling the technical support request module at www.lsi-lastem.it. For further information, refer to addresses and numbers below: Phone number: +39 02 95.414.1 (exchange) Address: via ex S.P. 161 Dosso n. 9-20090 Settala Premenugo, Milano Web site: www.lsi-lastem.it Commercial service: info@lsi-lastem.it After-sales service: support@lsi-lastem.it, riparazioni@lsi-lastem.it INSTUM_01378 Pag. 8/8