Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Similar documents
Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Autocalibration Systems for In Situ Oxygen Analyzers

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

HFID Heated Total Hydrocarbon Analyzer Module

A New Standard of Excellence

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Model 144H. Product Data Sheet , Rev DB February Content

Oxymitter 5000 Hazardous Area Oxygen Transmitter

Zircomat Oxygen Analyzers

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Zirconia Oxygen Probe

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Model D12-IR. Digital Gas Transmitter...

High Pressure Conductivity Monitor

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

CLARITY II TURBIDIMETER

Rosemount 3051CFP Integral Orifice Flowmeter

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Model 144H. Product Data Sheet , Rev DB February Content

Zareba Sensepoint Pro

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Hazardous Area Zirconia Oxygen Systems

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Description. Applications

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Using the DewTrak II Dew Point/ Humidity Transmitter

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Sitron s CF Line of Flow Switch Monitors

Rosemount 2051T In-line Pressure Transmitter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Rosemount 3051CFC Compact Flowmeter

Dräger Polytron 7000 Fixed gas detector

Rosemount 2051T In-Line Pressure Transmitter

SEC Signature Process Gas Analyzer

Dependable Solutions for Gas Detection

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

ULTIMA X5000. MSAX5000.com

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Rosemount 3051L Level Transmitter

Using the Model 1500 Portable Chilled Mirror Hygrometer

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Rosemount 4500 Hygienic Pressure Transmitter

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Figure 1 DirectLine DL423 Sensor. Description, continued

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Dräger REGARD -1 Control System

Products and performance

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Ultrasonic Switches. Features & Benefits

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Industrial Grade Gas Detection Detecting The Difference

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Figure 1 DirectLine DL423 Sensor. Description, continued

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

THERMOCOUPLE & RTD INSTRUMENTS. Measuring your world since 1965

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Rosemount 3100 Series Ultrasonic Level Transmitters

The A-series Eletta Flow Monitor with local indication and analog output

APPLICATION DATA SHEET

Dew-Point Transmitters and Instruments

Hydrazine Analyzer Series 2171 Specifications

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

M5200 Industrial Pressure Transducer

Electronic Pressure Digest. Pressure and Temperature Transmitters

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Industrial Grade Gas Detection

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Specification VFD

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Temperature Solutions Line Card

Series 5000 Hydrazine Analyzer Model 60002

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Transcription:

OCX 4400 Product Data Sheet PDS 106-440.A01 February, 2001 Oxygen/Combustibles Transmitter Both oxygen and combustibles measurements in a single instrument Unique architecture - electronics mounted with sensor housing Simplified installation - no electronics box, probe cable or conduit - universal power supply provides automatic line voltage selection - adaptable to any O 2 /combustibles installation Robust, highly integrated electronics - surface mount technology improves reliability and vibration resistance Optional explosion-proof rating Digital HART communications - AMS/PlantWeb compatible Fully field repairable THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS Rosemount Analytical is the leader in oxygen flue gas analyzer technology. Our in situ, zirconium oxide oxygen analyzers have long been established as industry standards. Now we ve combined the reliability of the zirconium oxide oxygen measurement with the added benefit of a combustibles measurement. The OCX 4400 O 2 /Combustibles Transmitter is a rugged, industrial analytical instrument designed to detect oxygen and combustibles concentrations in flue gas temperatures up to 2600 F (1427 C). Typical applications include: Refinery process heaters Petrochemical reactor furnaces Small package hot water and steam boilers Inert process atmospheres Gas and oil boilers The combustibles analog output is 4-20 madc and the combustibles detector range is 0-1000 PPM to 0-5% combustibles. Individual analog signals (4-20 madc or 20-4 madc, selectable) are provided for O 2 and combustibles. With the option of internally mounted safe barriers on the analog output, the output is intrinsically safe. The OCX 4400 offers an optional NRTL CSA Class I, Div 1 Groups B,C,D and CENELEC EEx d IIB + H 2 certifications. HART communication is available. The HART protocol is accessible through a Model 275 handheld communicator or through a PC utilizing Asset Management Solutions (AMS) software. The HART protocol provides a link into Fisher-Rosemount s Plantweb field based architecture. Instrument technicians can interface with the O 2 /combustibles transmitter from the control room or any location where the analyzer s signal wires terminate. Service diagnostics and calibrations can be performed remotely as well. As an option, a Local Operator Interface (LOI) located on the analyzer electronics allows local communications to the electronics. The OCX 4400 offers a single alarm output. Optionally, relay outputs for low O 2 level alarm, high combustibles level alarm and unit fail can be provided by a separate HART device. The arrangement for the measurements is close coupled to the process flue gas and requires no sample conditioning. A sample is drawn from the process stream by an airoperated aspirator. The sample is drawn past the sensors. Dilution air is drawn in and mixes with the flue gas before passing the combustibles sensor. The OCX offers the unique ability to measure combustibles even with no oxygen left in the flue gas- a key advantage in detecting major combustion upsets, such as: Burner fouling Process tube leaks Major variations in fuel BTU values Loss of flame events Visit our website at www.processanalytic.com On-line ordering available.

THE OCX 4400 TRANSMITTER IS COMPLETELY FIELD REPAIRABLE The OCX 4400 is fully field repairable. The probe's design provides convenient access to internal probe components and electronics so technicians can service the unit in house. The sensing cell and heater/thermocouple are fully field-replaceable. We offer sample probes in different materials and lengths up to 9 foot for flue gas temperatures up to 2600 F (1427 C). The electronics can be mounted on the probe or separate to provide electronics and operator indication at grade level. We have built the O 2 /combustibles measurement around the time-proven Oxymitter oxygen cell and added a combustibles measurement with dilution air. This means the combustibles measurement is valid with or without oxygen in the flue gas stream and is extremely useful in reducing conditions. This situation is ideal for optimization of your fuel/air ratio or indication of your combustion process from a safety standpoint. OCX 4400 Housing Electronics Housing with Local Operator Interface OCX 4400 OXYGEN/COMBUSTIBLES TRANSMITTER FEATURES AND BENEFITS Features HART Communications Rapid, accurate, and reliable measurement of excess oxygen and combustibles Integrated sensors and electronics simplifies installation Temperature controlled combustible sensor Field-replaceable cell and heater/thermocouple assembly and plug-in electronics module Suitable for process temperatures up to 2600 F (1427 C) Probe Material of construction 316 LSS, inconel 600 and ceramic Oxygen cell sensitivity increases logarithmically when oxygen decreases Automatic line voltage selections Benefits All information from analyzer is updated constantly and provided to the operator or technician. Low cost to maintain. Provides inputs for significant fuel savings which normally pay for the analyzer in less than one year. Eliminates costs of mounting separate electronics. Eliminates cabling and conduit between sensors and electronics. Minimize drift and better sensitivity. Ease of maintenance. Suitable for use in most combustion applications. High resistance to corrosion and higher temperatures. Very useful for low oxygen levels. Ideal for low excess air burners. Automatically selects from 90 to 240 VAC and 50/60 Hz. without configuration or setup. Communicate with the OCX 4400 almost anywhere via the HART Protocol HART Model 275 Hand held interface Distributed control system with HART/AMS interface capability Page 2

SPECIFICATIONS ➀ OCX 4400 OXYGEN/COMB TRANSMITTER Net O 2 Range 0-1% to 0-40% O 2 Fully field selectable via HART Combustibles 0-1000 ppm to 0-5% Fully field selectable via HART Accuracy: Oxygen Combustibles ±.75% of reading or.05% O 2, whichever is greater ± 2% F.S. System Response to Test Gas: O 2 10 sec T90 Combustibles 25 sec T90 Temperature Limits: Process 32 to 2600 F (0 to 1427 C) Sensors Housing -40 to 392 F (-40 to 200 C) Internal Electronics Housing -40 to 185 F (-40 to 85 C) ➁ Probe Lengths, Nominal and Approximate Shipping Weights: 18 in (457 mm) package: 54 pounds (24.5 kg) 3 foot (0.91m) package: 55 pounds (24.5 kg) 6 foot (1.83 m) package: 57 pounds (26 kg) 9 foot (2.74 m) package: 59 pounds (26.8 kg) Mounting and Mounting Position: Sensors Flange Electronics Wall/Pipe Materials: Probes: 316L stainless steel - 1300 F (704 C) Inconel 600-1832 F (1000 C) Ceramic - 2600 F (1427 C) Enclosures: Low-copper aluminum Calibration: Semi-automatic or automatic Calibration Gas mixtures recommended: 0.4% O 2, Balance N 2 8% O 2, Balance N 2 1000 ppm CO, Balance N 2 (3 bottles test gas kit 1A99119G04) Calibration Gas Flow: 5 scfh (2.5 l/m) Reference Air: 2 scfh (1 l/m), clean, dry, instrumentquality air (20.95% O 2 ), regulated to 35 psi (238 kpa) Eductor Air: 5 scfh (2.5 l/m), clean, dry, instrumentquality air (20.95% O 2 ), regulated to 35 psi (238 kpa) Dilution Air: Blowback Air: (Optional) Sensors Housing: Electronics Housing:.1 scfh (0.5 l/m), clean, dry, instrumentquality air (20.95% O 2 ), regulated to 35 psi (238 kpa) Clean, dry, instrument quality air (20.95% O 2 ) regulated to 55 psi (374 kpa) NEMA 4X, IP55 Two ¾ -14 NPT conduit ports NEMA 4X, IP55 Two ¾ -14 NPT conduit ports Electrical Noise: Meets EN 50082-2 Electromagnetic Compatibility Generic Immunity Std., Part II Includes ENG 1000 4-R for Electrostatic Discharge 4 Kv contact, 8 Kv in air Includes ENG 1000 4-R Namurincreased 8 Kv contact, 16 Kv in air Includes IEC 801-4 fast transients-2 Kv on power supply and control lines Optional Hazardous Area Configurations: CSA NRTL/C Class I, Div. 1, Groups B, C, D CENELEC EEx d IIB + H 2 T3 Line Voltage: Universal 90 to 240 VAC, 48 to 62 Hz. No switches or jumpers required 3/4-14 NPT conduit port Isolated Output: O 2, 4-20mAdc, 950 ohm max with HART capability COMB, 4-20mAdc, 950 ohm max Logic Signals: SPA HART ALARM Module (Optional) Low O 2 Alarm High Comb Alarm Calibration Status Unit Failure Alarm Output Relay - Dry contact, 30mA and 30Vdc capacity Power Consumption Limits: Power Consumption of Heaters: 650 W nominal max Power Consumption of Electronics: 50 W nominal max Fisher-Rosemount has satisfied all obligations coming from the European Legislation to harmonize the product requirements in Europe. ➀ All static performance characteristics are with operating variables constant. Specifications subject to change without notice. ➁ Operating temperature of electronics inside of electronics housing, as measured by a HART Communicator, or Fisher- Rosemount Asset Management Solutions Software, or local operator interface. Page 3

OUTLINE DIMENSIONS FOR OCX 4400 OXYGEN/COMB TRANSMITTER 72 2.8 213 8.4 241 9.5 89 3.5 41 1.6 65 2.6 2" PIPE 28 1.1 299 11.8 56 2.2 203 8.0 194 7.7 89 3.5 68 2.7 389 15.3 B 2.8 72 125 4.9 452 18 A 5/8-11 STUDS (4) PLS EQ SP ON A 4.75 BC BOLT ADAPTOR PLATE TO OUTSIDE WALL SURFACE FIELD WELD PIPE TO ADAPTOR PLATE 2.50 DIA 6.00 2.50 MIN DIA IN WALL 3.50 O.D. REF 3.00 SCHED 40 PIPE SLEEVE 6.00 WELD OR BOLT ADAPTOR PLATE TO METAL WALL STACK OR DUCT METAL WALL JOINT MUST BE AIRTIGHT OF STACK OR DUCT. JOINT MUST BE AIR TIGHT. OUTSIDE WALL SURFACE MASONRY STACK WALL METAL WALL STACK OR DUCT CONSTRUCTION MASONRY WALL STACK CONSTRUCTION Table I. Mounting Plate Dimensions Dia. In. (mm) ANSI DIN JIS Flange (x) 6.00 7.5 6.5 (153) (190) (165) StudSize 5/8" - 11 M12 X 1.75 M16 x 2 4 Studs Eq. 4.75 BC 5.12 BC 5.71 BC Sp. on B.C. Table II. Removal/lnstallatlon Dim "A" Dim "B" Probe Insertion Removal Length Depth Envelope 18 in. (457 mm) 18.00 34.00 Probes (457) (864) 3 ft. (0.91 m) 36.00 52.00 Probes (914) (1321) 6ft.(1.83m) 72.00 88.00 Probes (1829) (2235) 9ft. (2.74 m) 108.00 124.00 Probes (2743) (3150) Page 4

ORDERING INFORMATION FOR GENERAL PURPOSE OCX44A O2 /Combustibles Transmitter O2 /Combustibles Transmitter - Instruction Book Code Probe Length and Material 11 18" (457mm) 316 SS up to 1300 F (704 C) 21 18" (457mm) Inconel 600 up to 1832 F (1000 C) 31 18" (457mm) Ceramic up to 2600 F (1426 C) 12 3' (0.91m) 316 SS up to 1300 F (704 C) 22 3' (0.91m) Inconel 600 up to 1832 F (1000 C) 32 3' (0.91m) Ceramic up to 2600 F (1426 C) 13 6' (1.83m) 316 SS up to 1300 F (704 C) 23 6' (1.83m) Inconel 600 up to 1832 F (1000 C) 14 9' (2.7m) 316 SS up to 1300 F (704 C) Code Probe Mounting Assembly 10 ANSI (N. American Std.) 20 DIN (European Std.) 30 JIS (Japanese Std.) Code Mounting Hardware - Stack Side 0 No Mounting Hardware ("0" must be chosen under "Mounting Hardware - Probe Side" below) 1 New Installation - Square weld plate with studs 2 Mounting to Model 218/240 Mounting Plate (with Model 218/240 Shield Removed) 3 Mounting to Existing Model 218/240 Support Shield 4 Mounting to Other Mounting (1) 5 Mounting to Model 132 Adapter Plate 6 Mounting to Ametek WDG-IVC 7 Mounting to Servomex Xendos 2700 8 Mounting to Elsag Bailey SMA-90 Code Mounting Hardware - Probe SIde 0 No Mounting Hardware 1 Probe Only (ANSI) (N. American Std.) 4 Probe Only (DIN) (European Std.) 7 Probe Only (JIS) (Japanese Std.) OCX44A 11 10 1 1 Cont'd Example Page 5

Code Code Electronic Housing - NEMA 4X, IP55 HART Communication -std (2) 0 1 Basic Unit 2 Local Operator Interface 3 Calibration Solenoids 4 IS Barrier (3) 5 Local Operator Interface and Calibration Solenoids 6 Local Operator Interface and IS Barrier (3) 7 Calibration Solenoids and IS Barrier (3) 8 Local Operator Interface and Calibration Solenoids and IS Barrier (3) Code Code Electronic Mounting 0 1 Integral to Sensor Housing Electronics 2 Split Electronics and no cable 3 Split Electronics and 6M (20 ft) cable 4 Split Electronics and 12M (40 ft) cable 5 Split Electronics and 18M (60 ft) cable 6 Split Electronics and 24M (80 ft) cable 7 Split Electronics and 30M (100 ft) cable 8 Split Electronics and 45M (150 ft) cable Code Accessories 00 None 01 Cal Gas Rotometer, Flow Rotometers and Reference Gas Set 11 Blowback Option and Cal Gas Rotometer, Flow Rotometer and Reference Gas 0 1 0 1 01 Example Note [1]: Where possible specify SPS number; otherwise provide details of existing mounting plate as follows: Plate with studs Plate without studs Bolt circle diameter, number and arangement of studs, stud thread, stud height above mounting plate. Bolt circle diameter, number and arrangement of holes, thread, depth of stud mounting plate with accessories. [2]: If the Local Operator Interface (LOI) is not implemented remote access and functionality available via Hart Communications (Model 275 Handheld Communicator) with O 2 /combusitibles device descriptor (DD) required. [3]: Use of IS Barrier prevents the use of the combustibles 4-20 ma output. Page 6

ORDERING INFORMATION FOR HAZARDOUS AREA OCX44C O2 /Combustibles Transmitter - Explosion Proof Explosion Proof O2 /Combustibles Transmitter - Instruction Book Code Probe Length and Material 11 18" (457mm) 316 SS up to 1300 F (704 C) 21 18" (457mm) Inconel 600 up to 1832 F (1000 C) 31 18" (457mm) Ceramic up to 2600 F (1426 C) 12 3' (0.91m) 316 SS up to 1300 F (704 C) 22 3' (0.91m) Inconel 600 up to 1832 F (1000 C) 32 3' (0.91m) Ceramic up to 2600 F (1426 C) 13 6' (1.83m) 316 SS up to 1300 F (704 C) 23 6' (1.83m) Inconel 600 up to 1832 F (1000 C) 14 9' (2.7m) 316 SS up to 1300 F (704 C) Code Probe Mounting Assembly 10 ANSI (N. American Std.) 20 DIN (European Std.) 30 JIS (Japanese Std.) Code Mounting Hardware - Stack Side 0 No Mounting Hardware ("0" must be chosen under "Mounting Hardware - Probe Side" below) 1 New Installation - Square weld plate with studs 2 Mounting to Model 218/240 Mounting Plate (with Model 218/240 Shield Removed) 3 Mounting to Existing Model 218/240 Support Shield 4 Mounting to Other Mounting (1) 5 Mounting to Model 132 Adapter Plate 6 Mounting to Ametek WDG-IVC 7 Mounting to Servomex Xendos 2700 8 Mounting to Elsag Bailey SMA-90 Code Mounting Hardware - Probe SIde 0 No Mounting Hardware 1 Probe Only (ANSI) (N. American Std.) 4 Probe Only (DIN) (European Std.) 7 Probe Only (JIS) (Japanese Std.) OCX44C 11 10 1 1 Cont'd Example The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Page 7

Code Code Electronic Housing - NEMA 4X, IP55 HART Communication -std (2) 0 1 Basic Unit 2 Local Operator Interface 3 Calibration Solenoids 4 IS Barrier (3) 5 Local Operator Interface and Calibration Solenoids 6 Local Operator Interface and IS Barrier (3) 7 Calibration Solenoids and IS Barrier (3) 8 Local Operator Interface and Calibration Solenoids and IS Barrier (3) Code Code Electronic Mounting 0 1 Integral to Sensor Housing 2 Split Electronics and no cable 3 Split Electronics and 6M (20 ft) cable 4 Split Electronics and 12M (40 ft) cable 5 Split Electronics and 18M (60 ft) cable 6 Split Electronics and 24M (80 ft) cable 7 Split Electronics and 30M (100 ft) cable 8 Split Electronics and 45M (150 ft) cable Code Accessories 00 None 01 Cal Gas Rotometer, Flow Rotometers and Reference Gas Set 11 Blowback Option and Cal Gas Rotometer, Flow Rotometer and Reference Gas 0 1 0 1 01 Example Note [1]: Where possible specify SPS number; otherwise provide details of existing mounting plate as follows: Plate with studs Plate without studs Bolt circle diameter, number and arangement of studs, stud thread, stud height above mounting plate. Bolt circle diameter, number and arrangement of holes, thread, depth of stud mounting plate with accessories. [2]: If the Local Operator Interface (LOI) is not implemented remote access and functionality available via Hart Communications (Model 275 Handheld Communicator) with O 2 /combusitibles device descriptor (DD) required. [3]: Use of IS Barrier prevents the use of the combustibles 4-20 ma output. ACCESSORIES Part Number Description 1A99119H01 Oxygen Bottles 0.4% balance N2 1A99119H02 Oxygen Bottles 8.0% balance N2 1A99119H06 CO Bottle 1000 PPM balance N2 1A99120H02 Regulator for Oxygen (may need 2) 1A99120H02 Regulator for CO 1A99119G06 3 wide wall mount bracket for gas bottles 1A99119G05 Calibration gas regulators kit 1A99119G04 Calibration gas bottles kit 1A99292H01 Moore Industries SPA for low O2 alarm, High CO alarm, calibraion status and unit fail 275D9EI5D0000 275 HART Communicator with 12 Meg buffer Emerson Process Management Rosemount Analytical Inc. Process Analytic Division 1201 North Main Street P. O. Box 901 Orrville, OH 44667-0901 USA T (330) 682-9010 Toll Free in US and Canada 1 (800) 433-6076 F (330) 684-4434 e-mail: gas.csc@emersonprocess.com www.processanalytic.com Rosemount Analytical Inc., 2001. All rights reserved. Printed in U.S.A. on recycled paper.