OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

Similar documents
SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

Manual Supplement. Product/System Title: Premium Clean Room Monitor. Contents of this manual supplement include:

Analog Room Pressure Monitor RPC Series

ESSEX ENGINEERING CORPORATION

Pump-Up Controller MODEL 4062

Pump-Down Controller MODEL 4052

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model 4001 Series Single Channel Controller

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Sierra Series 900 Single & Dual Channel System. Instruction Manual

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Pioneer-R16 Gas Monitor Operator s Manual

Carbon Monoxide Transmitter

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Delta P Plus Control

SEC 2000 Millenium Infrared Gas Detector

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Construction Electrical

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

RPM1600 Series Room Pressure Monitors

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Delta P Plus Control

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1

Instruction Manual Model A

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Flopurge TS. Operation Manual

Product Manual SZ1145

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

ACCURATE ELECTRONICS INC

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Temperature Controllers

Product Manual SZ1144

Series RSM Room Status Monitor. Specifications - Installation and Operating Instructions 5-13/32 [137.16] 8 [203.20] 4-5/8 [117.

Specification/ Data Sheet

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

EC Series Wall Unit Humidifier

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

RELEASE DEVICE CONTROLS

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

B-40/B-41 Modulating Temperature Controller

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

E340 BOILER CONTROL INSTALLATION MANUAL

ADC150 Automatic Draft Control

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Delta P Control. Installation and Operation Manual. Installation, Operation, and Service Information. English Master Language

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Accuracy by Design Products for the HVAC Professional

Power Supply Display Module PSDM. Installation and Operation Manual

Flostop TS D7E and A8E. Operation Manual

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Ammonia Leak Detector Manual

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Public Safety DAS Annunciator Panel

Installation Guide for models:

DE20 INSTRUCTION MANUAL

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Series. Access Power Controllers. Installation Guide

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Sapphire Series TSVW & TWWS Chillwater Digital Thermostats

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

PRYCO, INC. FUEL CONTROL

Scully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System

Electric Coils. Blower Coils. Product Information

Humidity Controller Specification and Installation Instructions. Model HRO20

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

ENERVEX ADC100 DRAFT CONTROL

Transcription:

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM PARAGON CONTROLS INCORPORATED P.O. BOX 99 FORESTVILLE, CALIFORNIA 95436-0099 (707) 579-1424 /SPM REV. 7, 7/24/09

TABLE OF CONTENTS SECTION PAGE 1.0 BASIC OPERATION 1 2.0 GUARDIAN FEATURES 1 2.1 Power Supply 2.2 Alarm Status 2.3 Alarm Selection 2.4 Audible Alarm Acknowledge 2.5 Remote Alarm Relay 2.6 Remote Room Pressure Selection 2.7 Remote Auxiliary Alarm 2.8 Display 2.9 Display Selection 2.10 Key Locked Access Door 3.0 CENTRAL MODULE CONFIGURATION 2 3.1 Equipment Required 3.2 Positive/Negative Space Pressure Alarming 3.3 Remote Positive/Negative Space Pressure Selection 3.4 Audible Alarm Activation/Deactivation 3.5 Analog Space Pressure Output Signal 3.6 Process Output Selection 4.0 PRE-STARTUP CHECK 3 4.1 Equipment Needed 4.2 Pre-Startup Check 5.0 DIFFERENTIAL PRESSURE TRANSDUCER CALIBRATION 4 5.1 Equipment Needed 5.2 Calibration Procedure 6.0-2.5v REFERENCE, ANALOG OUTPUT AND DISPLAY SCALING CALIBRATION 5 6.1 Equipment Needed 6.2 Calibration Procedure

1.0 BASIC OPERATION The Guardian is a complete system package consisting of space and reference pressure sensors and the central signal processing module. The central module measures and displays the pressure differential with a resolution of up to one ten thousandth of an inch water column. The LED display can be factory set for engineering units of either Inches Water Column or Pascals. An analog output which is linear to the pressure differential is provided for remote monitoring, control and data logging. An alarm condition will occur when the space pressure falls outside the preset operating range. During an alarm condition a local LED will illuminate, a local audible alarm circuit will be enabled, and an alarm relay shall energize for remote alarming purposes. An optional remote auxiliary alarm is available with an adjustable delay which will activate a local LED and the audible alarm. A key locked front panel allows for controlled access to the field configurable functions of the Guardian. These functions include pressure alarm setpoint adjustment, audible alarm on/off selection, adjustable delay of the pressure alarm to prevent nuisance alarms which would occur due to normal foot traffic, and differential pressure transducer calibration. 2.0 GUARDIAN FEATURES 2.1 POWER SUPPLY The Guardian utilizes an isolated linear type power supply generating +15vdc and 5vdc to power the pressure transducer sensor, scaling and digit circuitry. Input power to the Guardian is 24VAC. The power supply is fused with a 3/8 Amp Slow Blow Pico fuse, located near the input power terminal. 2.2 ALARM STATUS Both Normal and Alarm operating status is locally indicated via LED s on the Guardian face plate. 2.3 ALARM SELECTION The Guardian can be field configured to provide either Positive or Negative room pressure alarming function. In the Positive mode the alarm activates when space pressure falls below the alarm setpoint value. When in the Negative mode the alarm activates when space pressure rises above the setpoint value. 2.4 AUDIBLE ALARM ACKNOWLEDGE Muting of the local audible alarm during a loss of the required pressurization level. The audible alarm circuit shall be reset once the monitored pressurization level is within the acceptable operating range. 2.5 REMOTE ALARM RELAY A single-pole double-throw relay is energized whenever the space pressurization level is outside of the acceptable operating range. 2.6 REMOTE ROOM PRESSURE SELECT The Room Pressure Monitor can be configured for positive or negative room monitoring remotely by the closure of a dry contact. 2.7 REMOTE AUXILIARY ALARM 3

The auxiliary alarm can be activated either by a contact closure or contact opening. The alarm can be delayed up to 30 seconds and will activate the audible alarm. 2.8 DISPLAY The 3-1/2 digit LED is factory scaled to indicate the space pressurization level in engineering units of either Inches Water Column or Pascals. 2.9 DISPLAY SELECTION The 3-1/2 digit LED space pressure indicating meter is also utilized for indicating and adjusting the Alarm Setpoint value by depressing a push button switch located under the access door on the cover plate. Pressing of this push button toggles the indicated value between space pressure and alarm setpoint. If the switch is not pressed for approximately 60 seconds the display will automatically defaults to indicate the measured space pressure. 2.10 KEY LOCKED ACCESS DOOR The Key Locked Access Door allows for controlled access to Guardian configuration, alarm setpoint display and adjustment, alarm delay on activation adjustment, activation/deactivation of the local audible alarm, and differential pressure transducer calibration. 3.0 CENTRAL MODULE CONFIGURATION (Refer to Figures 2 and 3 for jumper locations) 3.1 Equipment Required 3.1.1 Small Needle Nosed Pliers 3.2 Positive/Negative Space Pressure Alarming 3.2.1 Positive space pressure alarming is established by placing jumper H3/ALARM SP in the + position, and jumper H4/SPACE in the POS position. 3.2.2 Negative space pressure alarming is established by placing jumper H3/ALARM SP in the -- position, and jumper H4/SPACE in the NEG position. 3.3 Remote Positive/Negative Space Pressure Selection 3.3.1 To configure for remote space pressure selection, set H3 & H4 jumper to AUTO position. 3.4 Audible Alarm Activation/Deactivation 3.4.1 To activate the local audible alarm function, place jumper H11/AUDIBLE ALARM in the ON position. 3.4.2 To deactivate the local audible alarm function, place jumper H11/AUDIBLE ALARM in the OFF position. 3.5 Analog Space Pressure Output Signal 4

3.5.1 To provide a 0 to 10vdc analog output signal for remote monitoring of the space pressurization level place jumper H5/PROCESS in the V position. 3.5.2 To provide a 4 to 20mAdc analog output signal for remote monitoring of the space pressurization level place jumper H5/PROCESS in the I position. 3.6 Process Output 1) Process Output signal can be changed between voltage or current by positioning H5 jumper to I or V. The following table gives the jumper position and corresponding output selection. H5 JUMPER SELECTION I V OUTPUT SELECTION 4-20 MA 0-10VDC TABLE 3.5 OUTPUT SELECTION 4.0 PRE-STARTUP CHECK (Refer to Figure 1, 2 & 3 For Test Point and Adjustment Locations) 4.1 Equipment Needed 4.1.1 4-1/2 Digit Digital Multi Meter (Fluke Model 8062A Or Equivalent DMM) 4.1.2 Potentiometer Adjustment Tool (Spectrol) 4.2 Pre-Startup Check 4.2.1 With 24VAC power applied to the Guardian, Verify LED displays illuminate. 4.2.2 Monitor TP2 and verify a reading of +5.5 +.6 vdc. 4.2.3 Monitor TP3 and verify a reading of -4.8 +.6 vdc. 4.2.4 Monitor TP4 and verify a reading of +15.6 vdc. 4.2.5 Monitor TP5 and verify a reading of +2.5.1vdc. 4.2.6 Monitor TP6 and verify a reading of -2.5.1vdc. 4.2.7 Open access door and connect the positive (+) probe of DMM to TP7 (DPT) and the common (-) probe to TP1 (). Disconnect one side of ROOM and REFERENCE pneumatic tubing from fittings. Verify a reading of 0.005vdc. If out of specification, adjust ZERO potentiometer (R4) for 0.000vdc +.001vdc. 5

FIGURE 1 TEST SET-UP 5.0 DIFFERENTIAL PRESSURE TRANSDUCER CALIBRATION PROCEDURE (Refer to Figure 1 For Test Set-Up) 5.1 Equipment Needed 5.1.1 4-1/2 Digit Multi Meter (Fluke Model 8062A Or Equivalent DMM) 5.1.2 Precision Manometer (Ashcroft Model ATE-100 Or Equivalent) 5.1.3 Compressed Air source (Paragon Model AP-100 Air Pump) 5.1.4 Low Pressure Signal Generator (Paragon Model PS-100) 5.1.5 Potentiometer Adjustment Tool (Spectrol) 6

5.2 Calibration 5.2.1 Disconnect the pneumatic tubing from the left hand fitting labeled ROOM and REFERENCE. This will produce a zero differential input pressure to the transducer. Adjust the ZERO (R4) potentiometer for a reading of 0.000vdc, + 0.001vdc at TP7. 5.2.2 Obtain the full scale input range from the label located on the back of the access door. With the pneumatic signal generator apply the required full scale pressure to the left side ROOM pneumatic port. Adjust the SPAN (R10) potentiometer for a reading of 1.00vdc, + 0.001vdc at TP7. 5.2.3 Repeat steps 1 and 2 to verify that they meet specification tolerances. Large adjustments to either zero or span may result in a slight shift in the other adjustment. 6.0-2.5v REFERENCE, ANALOG OUTPUT AND DISPLAY SCALING CALIBRATION Notes: 1. Removal of Guardian from the wall will be required to perform the following calibration procedure. 2. All voltage measurements will be performed with DMM common (-) probe attached to TP1. 3. Refer to Figure 1.0 for test set-up and Figure 2.0 & 3.0 for test point locations. 4. Analog output configuration (CURRENT or VOLTAGE) must be confirmed prior to calibration. To determine the output configuration, refer to the label on the back side of the access door and confirm by checking jumper H5/PROCESS. 5. For CURRENT output configuration, disconnect field wiring from J2/PROCESS- OUT terminal. Place DMM in current mode, and install leads in series with field wiring. 6.1 Equipment Needed 6.1.1 4-1/2 Digit Multi Meter (Fluke Model 8062A Or Equivalent DMM) 6.1.2 Precision Manometer (Ashcroft Model ATE-100 Or Equivalent) 6.1.3 Compressed Air source (Paragon Model AP-100 Air Pump) 6.1.4 Low Pressure Signal Generator (Paragon Model PS-100) 6.1.5 Potentiometer Adjustment Tool (Spectrol) 6.2 Calibration 6.2.1 Monitor TP6 and adjust R106(-2.5v ADJ) for a reading of -2.5.001v. 6.2.2 With zero input pressure to the transducer 6.2.2.1 CURRENT (Uni-Polar Range)- Adjust R89 (ZERO) for a reading of 4.0mA,.01mA. CURRENT (Bi-Polar Range)- Adjust R89 (ZERO) for a reading of 12.0mA,.01mA. 7

6.2.2.2 VOLTAGE (Uni-polar Range)- Adjust R75 (ZERO) for a reading of 0.00vdc,.01vdc between J2 PROCESS (OUT+) and () terminals. VOLTAGE (Bi-polar Range)- Adjust R75 (ZERO) for a reading of 5.00vdc,.01 vdc between J2 PROCESS (OUT+) and () terminals. 6.2.3 With full scale pressure applied to the high port (See label on back of access door) 6.2.3.1 CURRENT - Adjust R87 (SPAN) for a reading of 20.0mA. 6.2.3.2 VOLTAGE - Adjust R84 (SPAN) for a reading of 10.00vdc between J2 (OUT+) and () terminals. 6.2.3.3 Adjust R38 (DISPLAY) for full scale value on the LED display. 6.2.4 Repeat steps 2 and 3 to verify that they meet specification tolerances. Large adjustments to either zero or span may result in a slight shift in the other adjustment. 8

REFERENCE PRESSURE SENSOR 1/4"X.170 TUBE BARB (CONDUIT BETWEEN SENSORS AND MONITOR PANEL MAY BE REQUIRED). J1 24VAC POWER EARTH GROUND J2 ROOM PRESSURE SENSOR SEE DETAIL A NA PROCESS OUTPUT(0-10VDC/4-20MA) NA MONITOR PANEL J4 NC COM NO REMOTE POS/NEG SELECT (OPTION) AUXILIARY ALARM (OPTION) REMOTE ALARM TRIPLE GANG DOUBLE DEEP ELECTRICAL BOX (T&B PART NUMBER: H3BD-3/4-1 OR EQUAL) ELECTRICAL CONNECTIONS ROOM 24VAC POWER IN+ OUT+ OUT+ EXT. SP. PROCESS CONT REFERENCE NC COM NO ALARM ROOM PRESSURE CONNECTION REFERENCE PRESSURE CONNECTION DETAIL A FIGURE 2 9

T1 TRANSFORMER COMPONENT SIDE R38 H4 SPACE AUTO POS NEG R106-2.5V ADJ. H2 ALARM CONT. DISPLAY SPAN H3 ALARM SP + - AUTO SP. PROCESS CURRENT OUTPUT ZERO & SPAN PROCESS VOLTAGE OUTPUT ZERO & SPAN R89 R87 H5 R75 CURRENT ZERO CURRENT SPAN VOLTAGE ZERO SPAN F1 J1 24VAC IN+ OUT+ J2 OUT+ H10 CL OP ROOM REFERENCE TP1 TP1 TP2 +5V TP3-5V TP7 DPT TP4 +15V TP5 +2.5V TP6-2.5V INV NON- J4 INV NC COM NO ALARM R84 H1 RELAY CONT. S.P. INPUT ROOM PRESSURE CONNECTION REMOTE POS/NEG ROOM SELECT REMOTE AUXILIARY ALARM REFERENCE PRESSURE CONNECTION FIGURE 3 10