EATON DFDAP-M / FDAP-M Remote Alarm Panels

Similar documents
Remote Alarm Panels Features

DIESEL Engine Fire Pump Controllers Features

FT60 Reduced Voltage - Autotransformer

Transfer Switch Features

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Transfer Switch Features

FDF Foam Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

LMR Electric Fire Pump Controllers Features

EATON LMR Plus Electric Fire Pump Controllers

LMR Electric Fire Pump Controllers Features

PROJECT: CUSTOMER: ENGINEER: DRAWING CONTENTS: WIRING

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Fire Pump Controllers Foam (Additive) Controllers

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Variable Frequency Drive SERIES MP800 VFD

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Across-the-Line SERIES MP300 Combined Manual and Automatic

SERVICE BY QUALIFIED PERSONNEL ONLY

Model A1600 Series Annunciator

ELECTRIC FIRE PUMP CONTROLLER

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Soft Start Series MP700 Solid State, Reduced Voltage

FTA200-A REMOTE ALARM PANEL

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

FD30 Full Voltage - Across the Line July 2011

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Conventional Releasing Control Panel

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

4 & 8-POINT ANNUNCIATORS Instruction Manual

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Specification/ Data Sheet

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Series. Access Power Controllers. Installation Guide

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Commercial and Light Industrial Fire Alarm Control Panel

ESP TECHNOLOGIES LIMITED

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

MPT Electric Fire Pump Controller

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

21-light Remote Annunciator. Owner s Manual

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

SECTION LOW VOLTAGE LIGHTING CONTROLS

INTRODUCTION / TABLE OF CONTENTS

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

SFC-200 SERIES LED FIRE ALARM PANEL

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

FT20 Full Voltage - Limited Service. Electrically and Mechanically

FDJ SERIES Jockey Pump Controllers Features

TO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

MANUAL RESET ALARM RELEASE

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

OPTICAL TURNSTILE SYSTEM

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

SECTION AUTOMATIC TRANSFER SWITCHES

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Product Manual. The `Safety Shoe (shown below):

Powerohm Resistors Digital HRG System

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Beacon 800 Gas Monitor Operator s Manual

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Marley Collection Basin Heater Circuit

SAFETY INFORMATION AND WARNINGS

Operating Instructions. For. Alarm Control Module. Model SSR 500

ECO1ZN3P, ECO2ZN4P ECO

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Transcription:

O & M Manual IM05805008K

O & M Manual IM05805008K TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER 1 2. ELECTRICAL CONNECTIONS 1 2.1 ELECTRICAL CHECKOUT INSTRUCTIONS 2 2.2 ELECTRIC ALARM PANELS 2 2.2.1 Pump Running check 2 2.2.2 Common Alarm check 2 2.2.3 Phase Failure check 2 2.3 DIESEL ALARM PANELS 2 2.3.1 Engine Running' & 'Controller in OFF Mode' check 2 2.3.2 Common Alarm' and 'Low Fuel' check 2 2.4 OPERATION 3 2.4.1 Lamp Test Button 3 2.4.2 Normal and Supervisory (Backup) Voltage 3 2.4.3 Audible Alarm 3 2.4.4 Silence Alarm Button 3 2.4.5 Normal Power ON LED 3 2.4.6 Output Contacts 3 2.4.7 Output Relays 3 2.4.8 Alarm Inputs 3 3. FIGURE 1: ELECTRIC DIMENSIONS & SHIPPING WEIGHTS 4 4. FIGURE 2: DIESEL DIMENSIONS & SHIPPING WEIGHTS 5 5. FIGURE 3: ELECTRIC WIRING SCHEMATIC 6 6. FIGURE 4: DIESEL WIRING SCHEMATIC 7 i EATON Corporation www.chfire.com

O & M Manual IM05805008K INSTALLATION & MAINTENANCE MANUAL FOR REMOTE ALARM PANELS In order to familiarize yourself with the Remote Alarm Panel, please read the instruction manual thoroughly and carefully. Retain the manual for future reference.? Incoming Normal power and Supervisory (backup) power connections are clearly marked L and N and are located on the upper right side of the microprocessor board. 1. Installation and Mounting of the Controller Carefully unpack the controller and inspect thoroughly. The controller is not free standing and must be bolted securely to a wall. For dimensional and weight data please refer to the respective data sheets for the. Figure #1 - Electric Remote Alarm Panel Figure #2 - Diesel Remote Alarm Panel 2. Electrical Connections All electrical connections should meet national and local electrical codes and standards. The controller should be located or so protected that they will not be damaged by water escaping from pumps or pump connections. Current carrying parts of controllers shall be a minimum of 12 inches (305 mm) above the floor level.? Prior to starting, verify all data on the nameplate such as, catalog number and AC line voltage.? Inspect all electrical connections, components and wiring for any visible damage and correct as necessary. Ensure that all electrical connections are tightened before energizing.? Install necessary conduit using proper methods and tools. EATON Corporation www.chfire.com 1

O & M Manual IM05805008K 2.1 Electrical Checkout Instructions (For Use with Eaton ) WARNING:The following procedures should be carried out by a qualified electrician familiar with the electrical safety procedures associated with this product and its associated equipment. 2.2 Electric (Full Service) For Electrical Schematic Refer to Figure #3 Note: The alarm buzzer can be silenced by pressing the 'Silence Alarm' button on the front of the controller. 2.2. - Turn power on to the Fire Pump Controller and to the Remote Alarm Panel - In the Fire Pump Controller press the 'Local Start' pushbutton, the controller will start - The 'Pump Running' LED should illuminate and the alarm will sound on the Alarm Panel - Press the 'Stop' pushbutton on the front of the fire pump controller 2.2. - Move the disconnect handle on the Fire Pump Controller to the 'OFF' Position - The 'Common Alarm' and 'Phase Failure' LED's should illuminate and the alarm will sound on the Alarm Panel - Move the disconnect handle back to the 'ON' Position 2.2.3 - In the menu under the Alarm category, change the phase rotation to the opposite of what it is currently set for. - The 'Common Alarm' and 'Phase Reversal' LED's should illuminate and the alarm will sound on the Alarm Panel - Return the menu setting to the correct rotation. 2.3 Diesel For Electrical Schematic Refer to Figure #4 Note: The alarm buzzer can be silenced by pressing the 'Silence Alarm' button on the front of the controller. 2.3.1 - Turn power on to the Fire Pump Controller and to the Remote Alarm Panel - Place the controller in the 'AUTO' mode by turning the Main Switch to AUTO - Start the controller by pushing the Engine Test" button on the Diesel controller membrane / keypad, then push the Acknowledge button. - The 'Engine Running' light should illuminate and the alarm will sound on the alarm panel - Place the controller in the 'OFF' mode by turning the Main Switch to OFF - The 'Not in Auto Mode' LED will illuminate and the alarm will sound on the alarm panel 2.3.2 - Place the controller in the 'AUTO' mode by turning the Main Switch to AUTO - Start the controller by pushing the Engine Test" button on the Diesel controller membrane / keypad, then push the Acknowledge button. - Place a jumper between Terminal #38 & #11 in the Fire Pump Controller (Low Fuel) - The 'Common Alarm and Low Fuel LED s should illuminate and the alarm will sound on the alarm panel - Place the controller in the 'OFF' mode by turning the Main Switch to OFF 2 EATON Corporation www.chfire.com

O & M Manual IM05805008K 2.4 Operation 2.4.1 Lamp Test Button 2.4.7 Output Relays Each remote alarm panel is equipped with a Lamp Test button that fully tests all LED s when pressed. Operating the lamp test button will not change the state of the internal output relays Two Form-C alarm output relays can be programmed to indicate specific alarm conditions. The relays are printed circuit board style mounted on the alarm panel main circuit board. They are rated for 8 amps / 250VAC. They are de-energized under normal conditions regardless of input status selected. 2.4.2 Normal and Supervisory (backup) Supply Voltage The remote alarm panels will accept both 120 volt 50/60Hz and 240 volt 50/60Hz power supply on either of the normal and supervisory (backup) source inputs. If the normal source of supply is lost, the panel will automatically switch to the supervisory (backup) source. Both the normal and supervisory (backup) sources must be independent of each other. 2.4.8 Alarm Inputs Each controller is equipped with eight user selectable alarm inputs. Each can be selected as normally open (N.O.) or normally closed (N.C.) by the use of jumpers on the microprocessor board. 2.4.3 Audible Alarm When any alarm conditions are present, the audible alarm will sound. It will continue to sound until either the silence alarm button is pressed, or the alarm condition is satisfied. 2.4.4 Silence Alarm Button An audible alarm silencing button is provided that silences all active alarms when pressed. Pressing the button has no effect on the associated alarm LED(s). Should a second alarm condition occur after the silence button has been pressed, the audible alarm will re-sound until the silence button is pressed again, or the alarm condition has been satisfied. 2.4.5 Normal Power ON LED The normal power ON LED indicates when normal power is available and will turn off when the controller switches to the supervisory (backup) power source. An audible alarm will sound when normal power is not available and will remain ON until normal power is restored, or the silence pushbutton is pressed. 2.4.6 LED Visual Indicators The FDAP-M electric remote alarm panel has four LED visual indicators to indicate Pump Running, Phase Failure, Common Alarm and Phase Reversal. The DFDAP-M diesel remote alarm panel also has four LED visual indicators that indicate Not in AUTO Mode, Engine Running, Common Alarm and Low Fuel. EATON Corporation www.chfire.com 3

O & M Manual IM05805008K Electrical Remote Alarm Panel - FDAP-M 15.49 [393] 11.56 [294] 9.75 [248] 9.55 [243] 8.00 [203] 0.27 [ 7]x4 WALL MTG. HOLES 4.74 [120] NOTE: 1. ALL ENCLOSURES FINISHED IN FIRE PUMP RED 2. CABLE ENTRANCE EITHER TOP OR BOTTOM 3. STANDARD ENCLOSURE TYPE NEMA 1 N. Y. C. APPROVED FIGURE 1 4 EATON Corporation www.chfire.com

O & M Manual IM05805008K Diesel Engine Remote Alarm Panel - DFDAP-M 15.49 [393] 11.56 [294] 9.75 [248] 9.55 [243] 8.00 [203] 0.27 [ 7]x4 WALL MTG. HOLES 4.74 [120] NOTE: 1. ALL ENCLOSURES FINISHED IN FIRE PUMP RED 2. CABLE ENTRANCE EITHER TOP OR BOTTOM 3. STANDARD ENCLOSURE TYPE NEMA 1 N. Y. C. APPROVED FIGURE 2 EATON Corporation www.chfire.com 5

O & M Manual IM05805008K Wiring Schematic - Electric Remote Alarm Panel - FDAP-M : N. Y. C. APPROVED 6 EATON Corporation www.chfire.com FIGURE 3

O & M Manual IM05805008K Wiring Schematic - Diesel Remote Alarm Panel - FDAP-M : N. Y. C. APPROVED FIGURE 4 EATON Corporation www.chfire.com 7

2011 Eaton Corporation All Rights Reserved Printed in Canada Publication No.: IM05805008K March 2011 Eaton Corporation 10725-25th Street NE Unit 124 Calgary, Alberta, Canada T3N 0A4 Tel: +1-403-717-2000 Fax: +1-403-717-0567 email: chcfirepump@eaton.com www.chfire.com