Diode-Pumped Solid-State Blue Lasers

Similar documents
9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Laser Safety Training

3kW 6kW, QUBE Fiber Lasers

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

NLC 210 Air-Cooled Argon-ion Laser

Class 1 laser beam sensor safe for your eyes

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

NLC C61 Air-Cooled Argon-ion Laser

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

CATALOGUE LASER POINTERS

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

OWNERS MANUAL OPERATION GUIDE

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Return loss measurement of fiber optic components

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Understanding total measurement uncertainty in power meters and detectors

Commissioning of the ASTA Photoinjector Laser System

G4 Pulsed Fiber Laser

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

The FEL Facility Optical Diagnostics and FEL Characterization

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

G4 Pulsed Fiber Laser

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Important Safety Notice

Laser Collimated Beam Sensor

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Operator s Manual Mephisto Laser

Laser Distance Sensor Type M Analog-Output

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Pre-Installation Manual Vitara Modelocked Ti:Sapphire Laser

OMA-300 Process Analyzer

North Dakota State University Laser Safety

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

LASER SAFETY BARRIER

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

II-VI SUWTECH INC.

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

UNIVERSAL COMPACT SENSORS

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

APPLIED. OMA-406R Rackmount Process Analyzer

The University of Mississippi BASIC LASER SAFETY

LM-80V , h V LM-30V h V

Thermopile Sensor TPS 230 / 3365

The George Washington University. Laser Safety Manual

Medical Lasers and Laser Safety

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Instruments Designed for POF & Fibre Optic Cable Testing

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

INTERNATIONAL STANDARD

*For inquiries and questions about lasers, see the Yellow-Page.

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

3R, 3G 5R, 5G Point Laser Levels

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Chemistry Instrumental Analysis Lecture 4. Chem 4631

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Laser Use Registration & Application (L.U.R.)

PURPOSE OF THE PROCEDURE

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

Light fright. Improper laser use poses real safety hazards

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM


Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

USER S GUIDE. Please ONLY use manufacture provided transformer

Publication American Institute of Physics. Reprinted with permission.

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Solo PIV Nd:YAG Laser System Operator s Manual

Transcription:

Diode-Pumped Solid-State Blue s 58 BLD Series 58 BSD Series Our diode-pumped solid-state blue lasers provide high power output in a compact air-cooled package. They are ideal for use in semiconductor, biomedical, spectroscopic, interferometric, and holographic instrumentation applications; laser display devices; photo-plotters; PC board, wafer, and surface inspection equipment; and particle characterization instrumentation. Other wavelengths are available. Up to 400 mw at 457 nm All solid-state for reliability transverse and longitudinal mode Lightweight and compact Coherence length to eters Spectral line width down to 200 khz Low power consumption Universal power supply RS-232 interface OEM modules available Âμ

Specifications: 58 BLD & BSD series Common to All Models Wavelength: 457.5 8 0.5 nm Output Mode: single transverse mode Beam Quality: M 2 <1.3 Spectral Linewidth (FWHM): BSD Series: <0.5 nm BLD Series: <200 khz single frequency Polarization: Linear (horizontal) >:1 extinction ratio Warm-up Time from Cold Start: <3 minutes Beam Pointing Stability (constant temp.): <25 mrad With Beam Combiner/Expander: <7 mrad Power Stability (8 hours): 83% rms Amplitude Noise BLD Series: <2% (20 Hz to 1 MHz) Number of Beams: 2 (exit angles are not parallel to mechanical center line) Beam Diameter (1/e 2 at waist): Raw Beam: See Table Beam Diameter (1/e 2 ) with Beam Combiner/Expander: Approximately 4! table values Beam Divergence (full angle 1/e 2, ): <5 mrad (each beam) Beam Divergence (full angle 1/e 2, ): <5 mrad vertical (each beam) Beam Divergence () with Beam Combiner/Expander: <0.7 mrad Electrical Parameters Recommended Power Supply: 58 PSM 290 Electrical Service: to 240 Vac, 50 to 60 Hz Power Requirements: 150 W (typical) Cable Length: 36 inches (914 mm) Environmental Specifications Cooling: Forced air-cooled with heat sink Operating Temperature: +10 C to +35 C Storage Temperature: 410 C to +60 C Relative Humidity, Operating: 0 to 95% noncondensing Head Weight: 3.9 kg (8.6 lb) Power Supply Weight: 3.7 kg (8.1 lb) Options Beam combiner/expander 58 ACB 001 OEM module Custom beam delivery Custom configurations CDRH compliance kit LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION CLASS 4 LASER PRODUCT MAXIMUM OUTPUT POWER: 1 WATT AT 457 nm 10 mw AT 914 nm CLASSIFICATION PER EN 60825-1:1994 Most Melles Griot lasers and instruments are designed, tested, and manufactured for compliance with applicable European electrical and laser safety standards. OUTPUT BEAMS AND POLARIZATION 58 BLD and BSD series lasers have two output beams. In high-power frequency-doubled linear cavities, the forward- and backwardpropagating beams in the nonlinear crystal can generate unwanted effects such as depolarization and astigmatism. To avoid these effects, we separated the forward- and backward- propagating beams. The two beams exit the laser at a slight angle with respect to one another. Each beam is linearly polarized and can be treated optically as emanating from two waists located in the cavity. They can be reimaged into a single spot or used independently. Specifications for 58 BLD and BSD Series Diode-Pumped Solid-State s Model 58 BLD 001 58 BLD 301 58 BLD 305 58 BLD 601 58 BLD 605 58 BSD 001 58 BSD 301 58 BSD 305 58 BSD 601 58 BSD 605 Output Power (mw) 50 200 300 400 50 200 300 400 Beam Shape (both beams) Beam Dimensions (1/e 2 ; full width at waist) vertical (each beam) 0.15 mm 0.15 mm 0.15 mm 0.15 mm Beam Dimensions (1/e 2 ; full width at waist) horizontal (each beam) 0.29 mm 0.29 mm 0.29 mm 0.29 mm Beam Divergence (full angle 1/e 2, mrad) horizontal (each beam) <2.5 mrad <2.5 mrad <2.5 mrad <2.5 mrad Coherence Length Longitudinal Mode

7.50 (190.5) 1 DPSS POWER SUPPLY AND CONTROLLER Enable 4.88 (123.8) Disable Main System Power Fault Emission On Off External Interface RS-232 FRONT VIEW.60 (15.2) 12.55 (318.5) 11.7 (297.2).24 (6.96) SIDE VIEW dimensions: inches (mm) 58 PSM 290 power supply Select from more than 32 wavelengths Melles Griot manufactures a comprehensive line of lasers and laser systems for laboratory and OEM applications. Standard products include helium neon and helium cadmium lasers, diode-pumped solid-state lasers, argon, krypton, and mixed gas ion lasers, and semiconductor laser assemblies. Available wavelengths range from 325 nm in the ultraviolet to 1.52 mm in the near infrared, with powers from a few milliwatts to several watts, as shown in the chart below. MAXIMUM POWER (mw) 10,000 0 10 1 325 430 442 454 457 465 472 476 483 488 496 502 514 520 532 543 568 594 612 633 635 647 670 675 676 685 752 780 830 840 10641523 WAVELENGTHS (nm) Spectral output available from Melles Griot lasers

10.33 (262) 7.15 (182) 4.00 (102) 1.40 (36) 5.00 (127) 5.62 (143) dimensions: inches (mm) 58 BLD and BSD series laser head (top view) 3.95 () 3.20 (81) 1.85 (47) 4.32 (110) 3.60 (91) dimensions: inches (mm) 58 BLD and BSD series laser head (front view) Âμ www.mellesgriot.com Group 2051 Palomar Airport Road, 200 Carlsbad, CA 92009 1-800-645-2737 (760) 438-2131 FAX (760) 438-5208 E-mail: sales@carlsbad.mellesgriot.com Canada (613) 226-5880 France (01) 3012-0680 Germany (06251) 84060 Japan (03) 3407-3614 Netherlands (0316) 333041 Singapore 392-5368 Sweden (08) 54444900 United Kingdom (01353) 654500 MELLES GRIOT is a registered trademark of Melles Griot Inc. in the United States and certain other countries. In France, Germany, Italy, Belgium, The Netherlands, and Luxembourg, MELLES GRIOT is a registered trademark of Melles Griot B.V. Melles Griot follows a policy of continuous product development. For this reason, specifications are subject to change without notice. PRINTED IN USA 2001 MELLES GRIOT 2788 5/01

Solid-State Blue System 457 nm, 50 to 400 mw 85 BLS Series Melles Griot blue single beam diode-pumped solid-state blue lasers provide high power output in a compact air-cooled package. They are ideal for use in semiconductor, biomedical, spectroscopic, interferometric, and holographic instrumentation applications; laser display devices; photo-plotters; PC board, wafer, and surface inspection equipment; and particle characterization instrumentation. Other wavelengths are available. Up to 400 mw at 457 nm transverse and longitudinal mode Lightweight and compact Coherence length up to 5 meters output beam Low power consumption Universal input voltage power supply RS-232 interface Automatic power control CDRH and CE compliant Âμ

Specifications (Common to All Models) Output Specifications Wavelength: 457.5 8 0.5 nm Transverse Mode: Longitunital Mode: Beam Quality: M 2 <1.2 Coherence Length: Up to 5 m (ACC mode) Polarization: Horizontal: 85 Extinction Ratio: >:1 Warm-up Time from Cold Start: <5 minutes Beam Pointing Stability (22 0 1 C): <0.025 mrad With Beam Collimator: <0.007 mrad Power Stability (22 0 2 C over 8 hours): with Automatic Current Control (ACC): 85% with Automatic Power Control (APC): 82.5% Amplitude Noise (20 Hz to 2 MHz): <2% rms Beam Exit Angle: 4 81 (horizontal) 0 81 (vertical) Beam Diameter (1/e 2 at waist): See Table Below Beam Diameter (1/e 2 ) with Beam Collimator: Approximately 4! table values Beam Divergence: See Table Below Beam Divergence () with Beam Collimator: <1.5 mrad Electrical Specifications Input: to 240 Vac 8 10%, 50 to 60 Hz Power: 150 W (typical) Head Cable Length: 914 mm (36 inches) Environmental Specifications Cooling: Forced-air cooled with heat sink Operating Temperature: +10 C to +35 C Storage Temperature: 410 C to +60 C Relative Humidity, Operating: 0 to 95% noncondensing Head Weight: 3.9 kg (8.6 lb) Power Supply Weight: 3.7 kg (8.1 lb) Options Collimator 58 ASB 001 Custom beam delivery Custom configurations LASER LIGHT AVOID EXPOSURE TO BEAM CLASS IIIb LASER PRODUCT (CDRH) CLASS 3B LASER PRODUCT (EN 60825-1:1994) <500 mw at 457 nm Melles Griot lasers are designed, tested, and manufactured for compliance with applicable international electrical and laser safety standards. Beam Specifications Model Output Power (mw) Beam Shape Beam Dimensions (1/e 2 ; full width at waist, mm) Vertical/Horizontal Beam Divergence (full angle 1/e 2, mrad) Vertical/Horizontal IEC/CDRH Class 85 BLS 001 85 BLS 301 85 BLS 305 85 BLS 601 50 200 300 0.16/0.16 0.16/0.16 0.15/0.29 0.15/0.29 <5.0/<5.0 <5.0/<5.0 <5.0/<2.5 <5.0/<2.5 3B/IIIb 3B/IIIb 3B/IIIb 3B/IIIb

190 (7.50) 1 DPSS POWER SUPPLY AND CONTROLLER Enable 124 (4.88) Disable Main System Power Fault Emission On Off External Interface RS-232 FRONT VIEW 15.2 (.60) 319 (12.6) 297.2 (11.7) 7.0 (.24) air inlet dimensions: millimeters (inches) 85 BLS series power supply SIDE VIEW Select from more than 36 wavelengths Melles Griot manufactures a comprehensive line of lasers and laser systems for laboratory and OEM applications. Standard products include helium neon and helium cadmium lasers, diode-pumped solid-state lasers, argon, krypton, and mixed gas ion lasers, and semiconductor laser assemblies. Available wavelengths range from 325 nm in the ultraviolet to 1.52 mm in the near infrared, with powers from a few milliwatts to several watts, as shown in the chart below. MAXIMUM POWER (mw) 10,000 0 10 1 325 405 408 430 440 442 454 457 465 472 476 483 488 496 502 514 520 532 543 561 568 594 612 633 635 638 647 670 675 676 685 752 780 830 840 1523 WAVELENGTH (nm) Spectral output available from Melles Griot lasers

air outlet 262 (10.33) 182 (7.15) 102 (4.00) 36 (1.40) mechanical axis optical axis 4.0 81.0 16.5 (.65) dimensions: millimeters (inches) 127 (5.00) 143 (5.62) 85 BLS series laser head (top view) (3.95) 81 (3.20) 47 (1.85) 110 (4.32) 91 (3.60) 61 (2.00) dimensions: millimeters (inches) 85 BLS series laser head (front view) Âμ www.mellesgriot.com Group 2051 Palomar Airport Road, 200 Carlsbad, CA 92011 1-800-645-2737 (760) 438-2131 FAX (760) 438-5208 E-mail: sales@carlsbad.mellesgriot.com Netherlands (0316) 333041 Japan (03) 3407-3614 MELLES GRIOT is a registered trademark of Melles Griot Inc. in the United States and certain other countries. In France, Germany, Italy, Belgium, The Netherlands, and Luxembourg, MELLES GRIOT is a registered trademark of Melles Griot B.V. Melles Griot follows a policy of continuous product development. For this reason, specifications are subject to change without notice. PRINTED IN USA 2006 MELLES GRIOT 2788 REV E 4/06