Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Similar documents
Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

C0-210 Carbon Monoxide Probe

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

User's Guide. CO 2 Monitor. Model CO200

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

KANE-ALERT-CO 2 Monitor with Temperature

User's Guide. Pinless Moisture Meter. Model MO257

USER MANUAL Digital CO Monitor Model CO30

Battery Powered Commercial CO Monitor

USER GUIDE Heat Index Psychrometer

Model ST-128M Moisture Detector

! WARNING! User Manual LogiCO2 -Scout. Important Safety Information! CO2 Concentration Levels (%) and Effects ENGLISH

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

EVac II Programmable Digital Vacuum Gauge

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

4-IN-1 PIN/PAD RH MOISTURE METER

Dual Laser InfraRed (IR) Thermometer

Introduction. OM-THA2

CARBON MONOXIDE DETECTOR, i4h-co-m330

Red Alarm Indicator Light


VALTRONICS IAQ Monitor

R2310. Infrared Thermometer. Instruction Manual

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Dual Laser InfraRed (IR) Thermometer

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Pocket CO2 Monitor & Data Logger SAN-0001

User's Guide. Pinless Moisture Meter. Model MO257

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Using the GammaRAE II Personal Radiation Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Bacharach Bodyguard 4 User's Guide

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Sirius Technologies, Inc.

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

IPhone: 219/

Carbon Monoxide Transmitter

RAM GENE / RAM GENE-1

T-32-TS Touchscreen Thermostat. Installation Manual

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

EasyLog Data Logger Series

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Thermohygrometer with Single Type K Input and Superheat Function

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Programmable Thermostat

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

LD-5000 REFRIGERANT LEAK DETECTOR

AUTO CM CM USER GUIDE

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

HOBO U14 Data Logger User Manual

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

testo 316-EX gas leak detector Instruction manual

Macurco CM-21A Carbon Monoxide

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

WBGT Heat Stress Meter

Indoor/Outdoor Temperature Alert

Manhattan Fire Protection District

Oxygen Monitor Operating Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Water Tank Level Monitor

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

RV Safety Alarms Education Test

GasAlertMicroClip X3 Specifications

Macurco CM-E1 Carbon Monoxide Detector

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

SAS6000UTK-7 UNIVERSAL THERMOSTAT

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Single Gas Monitor 777

User s Manual For Model Aero-551 (Rev. Orig.)

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

TM-802 Formaldehyde Meter User s Manual

EasyLog Data Logger Series

CA6150 Carbon Monoxide Alarm

Users Manual. Air Velocity Meter

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Operate the Mutli-Gas Monitor PID

Specifications Minimum Typical Maximum Unit

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

SENSIT HXG-2d Combustible Gas Detector

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Transcription:

Model R9400 CO Meter with Temperature Instruction Manual com

Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Operating Instructions...6-7 Selecting Temperature Units... 6 Data Hold... 6 Set High CO Alarm Threshold... 6 Max Value... 7 Auto Power Off... 7 Backlight... 7 Beeper Off... 7 Battery Replacement... 8 For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com com 2

Safety For safety reasons, we recommend that this unit be certified every year. Do not use the meter as a personal safety monitor. Learn and recognize the effects of CO poisoning: 0 to 1 ppm Normal background levels 9 ppm ASHRAE Standard 62-1989 for living areas 35 ppm The average exposure level per U.S. OSHA workplace standards 50 ppm OSHA enclosed space 8-hour average level* 100 ppm OSHA exposure limit* 200 ppm Mild headache, fatigue, nausea and dizziness 400 ppm Headache occurs in 2.5 to 3.5 hours 800 ppm Dizziness, nausea and convulsions Death within 2 to 3 hours * U.S. Department of Labor, Occupational Safety & Health Administration (OSHA) Regulation 1917.24: The CO content in any enclosed space shall be maintained at not more than 50 ppm (0.005%). Remove employees from enclosed space if the CO concentration exceeds 100 ppm (0.01%). Features Large LCD dual display shows both Carbon Monoxide (CO) and Temperature measurements Backlit LCD display Adjustable alarm limits Low level battery indicator Auto power off Max/Data hold functions com 3

Specifications Display: CO Range: CO Accuracy: Temperature Range: Temperature Accuracy: Dual display 0 to 1000 ppm ±5% reading or ±5 ppm (whichever is greater) -20 to 70 C (-4 to 158 F) ±0.8 C (±1.5 F) Resolution: 1 ppm / 0.1 Sensor Life: Sensor Type: 3 years Stabilized Electrochemical CO Specific Sensor Thermistor Temperature Sensor Response Time (@ t90; in slowly moving air): Carbon Monoxide: 60 seconds Temperature: 10 seconds Temperature Coefficient: 0.1 x (specified accuracy)/ C (< 23 C or > 23 C) Operating Temperature: Operating Humidity: Storage Temperature: Storage Humidity: High CO Alarm: Sample Rate: Power Supply: Battery Life: 0 to 50 C (32 to 122 F) 10 to 90%RH -20 to 70 C (-4 to 158 F) 0 to 80%RH Audible alert when CO level rises above programmed limit 2 times per second 4 each AA/R6 batteries 200-hours continuous (with alkaline battery) Dimensions: 190 x 65 x 45 mm (7.5 x 2.6 x 1.7 ) Weight: Accessories: Approx. 235 g (8.3oz) Batteries and Soft Carrying Case com 4

Instrument Description 1. Sensor 2. LCD Screen 3. Hold Button 4. Max / Down Button 5. Power Button 6. Set Alarm Button 7. Backlight Button 8. C/ F / Up Button 9. Battery Cover Display Description 1. Battery Capacity 2. Auto Power Off Indicator 3. Max Indicator 4. Data Hold Indicator 5. Beeper Off 6. Unit Indication 7. Alarm Level 8. Unit Indication 9. Temperature Reading 10. SET Alarm 11. Alarm Indicator 12. CO Reading com 5

Operating Instructions Push the Power Button to turn the meter on and off. When turning the meter on it will preform a self diagnostic test. The LCD will count down from 60 to 0 while emitting a beep. If the meter passes the self-test it will begin monitoring, showing the current CO and Temperature readings on the screen. If the meter does not pass the self-test the LCD will display Err and the meter will not take a measurement. If the meter reads above 1000 ppm the LCD will display OL to indicate an out of range condition. The beeping functions much like the clicking of a Geiger counter: The higher the concentration of CO the faster the beeps will sound When above 200 ppm the beeper sounds continuously, while the frequency of the tone increases with the concentration of CO Selecting Temperature Units When the meter is first powered on the default scale setting is set to the Celsius ( C) scale. Press the C/ F Button to switch between Celsius and Fahrenheit. The meter will start up in the Temperature scale that was selected when turned off. Data Hold Press the Hold Button to freeze the current reading on the display. Press the button again to resume normal measuring. When Data Hold is active the Max and C/ F Buttons are disabled. Set High CO Alarm Threshold Press and hold the Set Alarm Button to Set the CO High Alarm Threshold. The setting range is from 0 to 1000 ppm. The default is set to 35 ppm. While holding the SET Button, press the Up and Down buttons to adjust the value. Release the SET Button to save and resume normal measuring. com 6

Max Value While taking a measurement, press the Max Button to enter Max Value Mode. Under this mode the maximum value is kept in the memory and updated with every new data reading. The Max Indicator will appear on the screen when the meter is in Max Value Mode. While the Max Indicator is on the screen the meter is updating the memory. This means that the data has been updated in the memory and the reading is the present temperature and carbon monoxide. Press the Max Button again to detect the immediate value, and the Max Indicator will flash on the LCD. To exit Max Value Mode, press and hold the Max Button for two seconds. Auto Power Off By default, when the meter is powered on, it is in the auto power off mode. The meter will power itself off after 30 minutes if no key operation is performed. To disable the auto power off feature, press and hold the Hold Button while powering on the meter. The Auto Power Off Indicator will disappear from the LCD indicating it is disabled. Backlight Press the Backlight Button to turn the LCD Backlight on and off. Beeper Off To turn the beeper off on the meter, press and hold the Backlight button while powering the meter on. The Beeper Off indicator will appear on the LCD. To re-enable the beeper, turn the meter off and then turn it back on. com 7

Battery Replacement 1. Remove the screw at the bottom of the battery door and lift the door away from the meter 2. Remove the four AA batteries from the compartment 3. Replace with four new AA batteries, observing proper polarity as depicted on the bottom of the battery compartment 4. Replace the battery door and tighten the screw to lock it in place com 8