Trinity Mk II WOODBURNING STOVE

Similar documents
104 MK II WOOD-BURNING STOVE

LEPRECHAUN 90 O.S.A WOODBURNING STOVE

Erin Non Boiler Solid Fuel Stove

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

MUCH WENLOCK CLASSIC NON-BOILER SOLID FUEL STOVE

Little Wenlock Solid Fuel Stove

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

FIONN SOLID FUEL BURNING STOVE INSTALLATION AND OPERATING INSTRUCTIONS

Oscar Solid Fuel Stove

MUCH WENLOCK BOILER SOLID FUEL STOVE

FIREPLACE INSERT, MODEL VOLCANO PLUS OWNER S MANUAL - INSTALLATION - OPERATION. Save These Instructions for Future Reference.

Woodburning Range MANUFACTURED BY: WATERFORD STANLEY (MARKETING) LTD., BILBERRY, WATERFORD, IRELAND. ASSEMBLY INSTALLATION AND OPERATING INSTRUCTIONS

NOT INSTALL THIS UNIT IN A MOBILE HOME.

Boston OWNERS MANUAL. Model: 1200-C & 1700C Free Standing WARRANTY REGISTRATION

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

PEDESTAL PLATE HEATER MODEL APS1100B

CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 8 CHIMNEYS AND VENTS

Ludlow Wood Burning Smoke Exempt Stove

MODEL CF CEILING SUPPORTED CHIMNEY

SAFETY NOTICE FEATURES PREPARATIONS INSTALLATION OPERATION

INSTALLATION INSTRUCTIONS

CHAPTER 8 CHIMNEYS AND VENTS

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Ludlow Non-Boiler (Multi-Fuel)

Little Wenlock Classic

St. Croix Greenfield Installation Manual

Kodiak 1200 FS & Kodiak 1700 FS F R E E S T A N D I N G W O O D S T O V E OWNER S MANUAL

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

Lismore Non Boiler Solid Fuel Stove

T-4000 WOOD STOVE. Wood Stove Heater Owner's Manual Installation and Operating Instructions PLEASE LEAVE THIS MANUAL WITH THE OWNER!!

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

INSTALLATION AND OPERATION MANUAL

Oisin Solid Fuel Stove

INSTALLATION AND OPERATING INSTRUCTIONS

BERRINGTON SOLID FUEL BOILER STOVE

Owner's Manual Installation and Operation

INSTALLATION AND OPERATION MANUAL

ULC-S610-M87 (A1998), UL

JADE RANGE LOG BROILER MODELS: JLB SERIES

INSTALLATION AND OPERATION MANUAL

Cabello Models: 1200-C & 1700-C Insert

Solis Inset 500 & 900

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. TECHNICAL MANUAL

Stockton. Clean-burn stove. MODELS: 3 MF/4 Wood/4 MF/5 MF. Installation and Operating Instructions. For Use in Great Britain and Eire

Corn Flame Energy Corn Stove Model 3000

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

SOLID FUEL WARM AIR FURNACE

Ardmore Non Boiler Solid Fuel Stove

INSTALLATION AND OPERATING GUIDE. PACIFIC INSERT Design - D SAFETY NOTICE. Model PLEASE SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2700-I ACT WOOD INSERT Advanced Combustion Technology (ACT)

SALZBURG XL. MODEL: SALZBURG XL MASONRY HEATER Conforms To: UL Certified To: ULC S S/N: D and up

Cast Iron Fireplace Insert

OWNERS MANUAL Models 2941, B2941, 2941B, B2941B WONDERWOOD THERMOSTAT CONTROLLED WOOD BURNING CIRCULATOR HOW TO ORDER REPAIR PARTS

Model X-96 (E.P.A. Phase II Approved)

Boston OWNERS MANUAL. Models: 1200-C & 1700-C Insert

Emifocus. Design Installation & Operating Manual v.2 FR Tested by OMNI-Test Laboratories, Inc. and approved to UL and ULC-S627-00

WOOD STOVE OWNERS AND OPERATORS MANUAL MODELS 1000, 1600, 1600INS, 2100 EF-183

ULC-S610-M87 (A1998), UL

Cara Glass Non Boiler Insert Stove

NOVA OWNER S MANUAL. Revision #0001 Report #1801V2

WOOD STOVE SERVICE MANUAL

SOLID FUEL WARM AIR FURNACE

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. TECHNICAL MANUAL

Shenandoah R65-E Coal Burning Heater Manual

INSTALLATION AND OPERATION MANUAL

NOTICE DO NOT DISCARD THIS MANUAL. Read, understand and follow these instructions for safe installation and operation.

Ashling Boiler & Non Boiler Solid Fuel Stove

AMERICAN ENERGY SYSTEMS, INC.

Solis Inset 500 & 900

Shenandoah R65-E Wood & Coal Burning Heater Manual (EPA Exempt)

Owners Manual 1869 Caboose Potbelly

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Model 1200G. SOLID FUEL WARM AIR FURNACE Owners Manual

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

High Efficiency Wood Stove - Small

H530. Installation and user manual. - Please read this manual carefully and save the instructions - Version: 10/09. Tested and Listed by:

Wood Stove 2100 Freestanding

2012 INTERNATIONAL FUEL GAS CODE VENTS

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE HP-0020S

Summit Wood Insert MODEL SUMMIT WOOD INSERT DESIGN-A INSTALLATION AND OPERATING INSTRUCTIONS SAFETY NOTICE

Solis Double Sided Insert

The Sonora. P23 Series PROFESSIONAL INSTALLATION IS HIGHLY RECOMENDED

4100- I ACT WOOD INSERT Advanced Combustion Technology (ACT)

CHALET 1600 Wood Burning Stove

Pacific Wood Insert MODEL PACIFIC WOOD INSERT DESIGN-D INSTALLATION AND OPERATING INSTRUCTIONS SAFETY NOTICE

INSTALLATION AND OPERATION MANUAL

Cabello 1200 FPI & Cabello 1700 FPI W O O D S T O V E I N S E R T OWNER`S MANUAL

Answer Wood Stove. Owner's Manual SAFETY NOTICE:

MODEL: SWC21. Breckwell 227 Industrial Park Road P.O. Box 151 South Pittsburg, TN (800) D CAUTION!

MERIDIAN-A Freestanding and Fireplace Insert TECHNICAL MANUAL

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Transcription:

Trinity Mk II WOODBURNING STOVE SAFETY NOTICE Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury or even death. If this stove is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled. This stove must be connected to a UL/U.L.C. listed High Temperature residential chimney, Factory Built, Residential Type and Building Heating Appliance, UL 103 or a code approved masonry chimney flue liner constructed in accordance with NFPA 211 Chimney Vents and Solid Fuel Burning Appliances Manufactured by Waterford Stanley (Marketing) Limited, Bilberry, Waterford, Ireland. INSTALLATION & OPERATING INSTRUCTIONS

TABLE OF CONTENTS PAGE NO. 1. General............................................................. 2 2. Pre-Installation Assembly................................................ 2 3. Top Flue Exit.......................................................... 3 4. Rear Flue Exit......................................................... 3 5. Blower............................................................... 3 6. Blower Operation Instructions............................................ 3 7. Floor Protection........................................................ 4 8. Location.............................................................. 4 9. Outside Air Connection.................................................. 4 10. Mobile Home Installation................................................. 5 11. Minimum Clearances to Combustible Materials............................... 5 12. Reduced Clearances.................................................... 6 13. Double Wall Connections................................................ 6 14. Wall Protectors........................................................ 6 15. Chimney............................................................. 7 16. Chimney Types: USA Only.............................................. 7 17. Chimney Types: Canada Only............................................ 7 18. Chimney Connectors.................................................... 7 19. Connecting to Masonry Chimney.......................................... 7 20. Thimbles............................................................. 8 21. Chimney Connector Systems, Thimbles & Clearances from Combustible Walls...... 8 22. Masonry Fireplace...................................................... 9 23. Ventilation & Combustion Air Requirements................................. 10 24. Spillage Test.......................................................... 10 25. Lighting.............................................................. 10 26. Primary Air Settings.................................................... 10 27. Low or Overnight Burn.................................................. 11 28. Maintenance.......................................................... 11 29. De-Ashing (When Fire has Burned Out).................................... 11 30. Disposal of Ashes..................................................... 11 31. Creosote (Formation & Need for Removal).................................. 11 32. Glass Replacement.................................................... 11 33. Glass Cleaning........................................................ 12 34. Vitreous Enamel Cleaning............................................... 12 35. Fire Safety........................................................... 12 36. In the Event of a Chimney Fire........................................... 12 37. Exploded View........................................................ 13 1

WATERFORD TRINITY MKII WOODBURNING STOVE INSTALLATION AND OPERATING INSTRUCTIONS GENERAL When installing, operating and maintaining your Waterford Trinity MK II Stove respect basic standards of fire safety. Read these instructions carefully before commencing the installation. Failure to do so may result in damage to persons and property. Consult your local Municipal office, Fire Department and your insurance representative to determine what regulations are in force. Save these instructions for further reference. The complete installation must be done in accordance with current Standards and Local Codes. It should be noted that the requirements and these publications may be superseded during the life of this manual. PRE-INSTALLATION ASSEMBLY (a) After removing the stove from its packing, open the ashpit door (item 13 in exploded view) and remove the contents (b) Open the firedoor (item 8) and remove the contents of the firebox, leaving the bricks in place. (c) Remove the ashlip (item 12) from the rear of the stove if you have not already done so. Remove the loose fitting hob (item 3) and place on a nonabrasive surface. Fig.2 (f) Fit the front ashlip (item 12) using two of the ashlip brackets (item 35) and screw together using four 1 /4 (6mm) x 1 /2 (12mm) hex head bolts provided. Stand the stove upright taking care not to strain the back leg bolts. Fig.3 Fig.1 (g) Fit the wooden handle (item 28) to the fuelling door (item 8) Fig.4 (d) Place the plastic packing on the ground at the left hand side of the stove. NOTE: As the stove is very heavy take care when laying the stove on its side on top of the packing. (e) Remove the wooden pallet by taking out the 4 retaining screws from the base of the legs (item 2). Discard brackets & woodscrews, replace levelling screws. h) If the side fuelling door (item 21) is to be used, fit the side ash lip (item 24) using two ashlip brackets (item 35) and screw together using four 2

1/4 (6mm) x 1/2 (12mm) hex head bolts provided. Take out the chrome locking bolt and fit door latch (item 73), the door latch spigot (item 40), and the wooden handle (item 28) provided. Fig. 7 Fig.5 This stove can be connected to either a top or rear exit by simply reversing the orientation of the flue spigot (item 5) on the flue spigot flange. For either the top or the rear exit option place the ceramic gasket onto the flue spigot flange located at the top of the back plate (item 31). TOP FLUE EXIT Screw the top outlet hob filler piece (item 6) onto the hob (item 3), screw top outer blanking plate (item 29) onto the heat shield (item 30) using the two 1/4 (6mm) x 3/4 (19mm) C/S screws provided. Fig. 6 BLOWER Caution: Moving parts may cause injury. Do not operate unit with blower housing removed. Danger: Risk of electric shock. Disconnect power before servicing unit. Hot parts: Do not operate unit with blower housing removed. The Listed Waterford Trinity Optional Blower comes assembled, wired, and ready for use. To fit the Listed Waterford Trinity MK II Optional Blower take off rear heat shield (item 30) and fit listed blower assembly (item 75) as per illustrations below. This unit must be connected to a grounded, Standard 110 volt, 60 Hz electrical outlet, Never route the power cord under or in front of the unit. Do not, under any circumstances, cut or remove the grounding prong from the power cord. Do not use an adaptor plug. Fig. 8 REAR FLUE EXIT Screw the rear outlet hob filler piece (item 57) to the hob (item 3) using the two screws provided. Screw the rear outlet heat shield blanking plate (item 58) to the heat shield (item 30) using the two 1/4 (6mm) x 3/4 (19mm) C/S screws provided. BLOWER OPERATION INSTRUCTIONS 1. Press switch to ON position (see fig. 9). 2. Fan will power up when stove temperature reaches snap switch operating temperature. 3. Fan operation will cease each time stove temperature drops below snap switch operating temperature. 3

Fig. 9 Fig. 12 200mm 50mm 50mm 200mm 450mm 450mm Fig. 10 Air inlet duct FLOOR PROTECTION When installing this heater on a combustible floor, a floor protector, consisting of a layer of noncombustible material at least 3/8 (9mm) thick or 1/4 (6mm) thick covered with 1/8 (3mm) sheet metal is required to cover the area under the heater and to extend to at least 18 (450mm) at the front and 8 (200mm) to the sides. This will provide protection from sparks and embers which may fall out from the door when stoking or fuelling. Fig. 11 200mm 200mm 200mm LOCATION There are several conditions to be considered when selecting a location for your Waterford Trinity MK II Wood Stove. (a) Distance from a safe chimney. (b) Position in the area to be heated - central locations are usually best. (c) Allowances for proper clearances to combustibles. (d) Obstruction in the ceiling, upper floor or roof, for example, ducting, plumbing, electrical fittings and wiring, overhead fixed furnishings etc. WARNING: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION DO NOT OBSTRUCT FREE AIR SUPPLY TO THE AIR INLET DUCT LOCATED AT THE BACK OF THE STOVE. Fig. 13 450mm If the side door is to be used the floor protector must extend at least 18 (450mm) from the right side of the stove when looking from the front. Air Inlet Duct OUTSIDE AIR CONNECTION This stove may be connected direct to the outside of the house for its combustion air supply. The primary air inlet (item 55) located at the bottom of the back panel (item 31) may be connected to outside air. 4

To connect this stove to an outside air supply use either 4 (100mm) rigid of flexible stainless steel pipes or non-combustible corrosion-resistant materials not more than 54 (1370mm) in length and having no sharp bends or corners other than the down turn at the terminus. The outside air inlet terminus must be fitted with a 1 /4 (6mm) x 1 /4 (6mm) corrosion-resistant wire mesh to prevent leaves, and rodents entering from the outside. Air inlets traversing cavity walls should include a continuous duct across the cavity. The duct should be installed in such a manner as not to impair the weather resistance of the cavity. Joints between air vents and outside walls should be sealed to prevent ingress of moisture. Fig.14 elevation of any part of the Mobile Home within 10 ft. (3040mm) of the chimney. 7. The chimney systems shall comply with the standard for Chimneys Factory - Built Residential Type and Building Heating Appliances UL 103. 8. Any openings in a chimney guard if used must not permit the entrance of 3/4 (19mm) diameter rod. 9. CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE MAINTAINED. 10. Check any other local building code as other local codes may apply. 11. WARNING: DO NOT INSTALL IN A SLEEPING ROOM. NOTE: Listed factory built chimney connectors including elbows are acceptable for use in Mobile Home Installations. Air Duct MOBILE HOME INSTALLATION Wire Mesh In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home. CAUTION: Do not obstruct combustion air opening. 1. The stove must be permanently bolted to the floor of the Mobile Home using the floor screws provided. 2. The stove must have a permanent outside air source for combustion. 3. The stove must be grounded to the steel chassis of the Mobile Home. 4. A listed chimney system, roof thimble, spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used. 5. If the chimney exits the Mobile Home at a location other than through the roof, and exits at a point 7 ft. (2100mm) or less above the ground level on which the Mobile Home is positioned, a guard or method of enclosing the chimney shall be fitted at the point of exit for a height up to 7 ft. (2100mm). 6. The chimney shall be attached directly to the room heater and shall extend at least 3 ft. (910mm) above the part of the roof through which it passes. The top of the chimney should project at least 2 ft. (610mm) above the highest MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS From the front of stove From the side of stove From corner installation From back of stove horizontal installation only 48 (1220mm) 22 (560mm) 14 (355mm) 8 (200mm) If the side door is to be used the right hand side clearances when looking from the front of the stove must be increased to 48 (1220mm) Mantle clearance 30 Trim Clearance Vertical Single Wall Flue Pipe (USA) Vertical Single Wall Flue Pipe (Canada) USA from back of stove Canada from back of stove 22 (560mm) 14 (355mm) 18 (460mm) 15 (380mm) 19 (480mm) This stove has been tested in a combustible alcove measuring 84 high x 72 wide x 48 deep. 5

Fig.15 560mm 560mm Fig.16 (c) When listed pipe shields are used - top exit option only - the clearances may be reduced to 9 (225mm) from the pipe shield and 11 (280mm) from stove back. 200mm Fig.24 Fig.17 (355mm) (355mm) Fig.18 (560mm) (1220mm) Fig.25 Fig.26 (225mm) Fig.19 Fig.20 (760mm) (760mm) (560mm) (560mm) (560mm) (560mm) (355mm) Fig.21 USA Fig.22 (460mm) CANADA 2130mm REDUCED CLEARANCES Fig.23 1830mm 1220mm Under certain conditions the minimum clearances may be reduced by means of: (a) The use of listed pipe shields, installed in accordance with the manufacturer s instructions. (b) Shields constructed in accordance with NFPA211 (USA), Can3-B365 installation code for solid fuel fired appliances. 6 DOUBLE WALL CONNECTIONS Double wall chimney connectors may be substituted for the shielded pipe provided it is UL/ULC listed for a 9 (225mm) clearance or less. WALL PROTECTORS Materials and products listed for the purpose of reducing clearance to combustibles shall be installed in accordance with the conditions of the listing and the clearances may be reduced by the percentage reduction as stated in the wall shield manufacturer s instructions. For clearance reduction systems using an air space between the combustible wall and the wall protector, adequate air circulation shall be provided by one of the following methods. 1. Adequate air circulation may be provided by leaving all edges of the air protector open with at least a 1 (25mm) air gap. 2. If the wall protector is mounted on a single flat wall, away from corners, an adequate air circulation may be provided by leaving bottom and top edges or only the side and top edges open with at least a 1 (25mm) air gap. 3. Wall protectors that cover two walls in a corner shall be open at the bottom and top edges with at least a 1 (25mm) air gap.

4. All clearances shall be measured from the outer surface of the combustible material to the nearest point on the surface of the Waterford Trinity MK II Stove disregarding any intervening protection applied to the combustible material. When using a manufactured wall shield system observe local building codes and by-laws. Fig.27 Poor draught conditions will result in poor performance. NOTE: Connection to type B gas vents approved for connection to certain gas burning appliance will only result in a fire. CHIMNEY TYPES: USA ONLY The stove must be connected to a UL 103 Listed residential type HT and Building Heating Appliance Chimney installed in accordance with the manufacturer s instructions or a masonry chimney constructed in accordance with NFPA 211 Chimney Vents and Solid Fuel Burning Appliances. Fig.28 (25mm) CHIMNEY TYPES: CANADA ONLY The stove must be connected to an Underwriters Laboratories of Canada Labelled factory built 650 o C c h i m n e y, installed in accordance with the manufacturer s instructions or in a lined masonry chimney acceptable to the authority having jurisdiction. CHIMNEY CONNECTOR Fig.29 (25mm) The chimney connector (smoke pipe) is used to connect the Waterford Trinity MK II Stove to the chimney described above. The chimney connector must be made of Corrosion Resistant Steel, 24 gauge or heavier (black or equivalently treated steel). Be sure to fasten the chimney connectors together and also to the flue outlet of the stove through the two holes provided. Use at least two screws for each joint/connection. Be sure that the joints are tight and fully sealed. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, floor or ceiling. CHIMNEY (25mm) The Waterford Trinity MK II Stove is a radiant room heater and must be connected to a chimney of the proper size and type capable of providing an adequate continuous draught or 0.06 wg minimum. It is best to connect to a chimney of the same size as the stove spigot. Connection to a large size may result in somewhat less draught. DO NOT CONNECT TO A CHIMNEY SERVING ANOTHER APPLIANCE. Minimum chimney height is 15 feet (4570mm) from floor on which stove is installed. An existing masonry chimney should be inspected and, if n e c e s s a r y, repaired by a competent mason or relined using an approved relining system. 7 Where passage through a wall or partition of combustible construction is desired, the installation shall conform to NFPA 211 or CAN/CSA - B365. The connector should maintain a pitch or rise of at least 1 /4 (6mm) per foot from the stove to the chimney. It should be installed so as to avoid sharp turns or other combustion features that would create excessive resistance to the flow of flue gases. It should be securely supported. The entire length of a connector should be readily accessible for inspection, cleaning and replacement. CONNECTING TO MASONRY CHIMNEY The connector to a masonry chimney must extend through the wall to the inner face or liner but not beyond, and must be firmly cemented to masonry.

The connector may pass through walls or partitions constructed o combustible material to a masonry chimney provided the connector system selected is installed in accordance with the proper clearances and conditions. Fig.30 (305mm) to THIMBLES Thimbles for chimney or vent connector should be fire clay (ASTM C 315, specification for Clay Flue Linings), galvanised steel of minimum thickness of 24 gauge, or material equivalent durability. Thimbles should be installed without damage to the liner. The thimble should extend through the wall to, but not beyond, the inner face of the liner and should be firmly cemented to masonry. Thimbles should be located to provide adequate pitch or rise of chimney or vent connectors and, where the ceiling above the appliance is constructed of combustible material, the location of the thimble should provide minimum clearance required for the connector as specified in section under Minimum Clearances to Combustibles. Insulation material used as part of wall passthrough system should be of non-combustible material and should have a thermal conductivity of 1.0 Btu.in./ft.F (4.88kg.cal/hr.m.C) or less. All clearances and thicknesses are minimums; larger clearances and thicknesses are acceptable. Any material used to close up an opening for the connector should be masonry chimney, except for system 2 (under heading Chimney Connector Systems, Thimbles and Clearances ), shall extend to piece through the wall pass-through system and the chimney wall to the inner face of the flue liner, but not beyond. CHIMNEY CONNECTOR SYSTEMS, THIMBLES, AND CLEARANCES FROM COMBUSTIBLE WALLS 1. Minimum 31/2 (90mm) thick brick masonry wall framed into combustible wall with a min. of 12 (305mm) brick separation from clay liner to combustibles, Fire Clay Liner (ASTM C315 or equivalent) min. 5/8 (16mm) wall thickness, should run from outer surface of chimney flue liner and should be firmly cemented in place. 2. Solid insulated listed factory-built chimney length of the same inside diameter as the chimney connector and having 1 (25mm) or more of insulation with a min. 9 (229mm) air space between the outer wall of the chimney length and combustibles. The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the brick masonry penetration with non-water-soluble refractory cement. Supports should be securely fastened to wall surfaces on all sides. Fasteners between supports and the chimney length shall not penetrate the chimney liner. (230mm) (50mm) (305mm) of brick (230mm) min. (50mm) 3. Sheet steel chimney connector, min. 24 gauge in thickness, with a ventilated thimble, having two 1 (25mm) air channels, separated from combustibles by a min. of 6 (150mm) of glass fibre insulation. Opening should be covered and thimble supported with a sheet steel support, min. 24 gauge in thickness. Supports should be securely fastened to wall surfaces on all sides and should be sized to fit and hold chimney section. Fasteners used to secure chimney sections should not penetrate chimney flue liner. Fig.31 Minimum 6 (150mm) fibre Insulation (25mm) (50mm) (25mm) constructed of sheet steel 8

4. Solid insulated listed factory-built chimney length with an inside diameter 2 (50mm) larger than the chimney connector and having 1 (25mm) or more of insulation, serving as a pass-through for a single wall sheet steel chimney connector of min. 24 gauge thickness, with a min. 2 (50mm) air space between the outer wall of chimney section and combustibles. Minimum length of chimney section shall be 12 (305mm). Chimney section concentric with and spaced 1 (25mm) away from connector by means of sheet steel support plates on both ends of chimney section. Opening shall be covered and chimney section supported on both sides with sheet steel supports of min. 24 gauge thickness. Supports should be securely fastened to wall surfaces on all sides and shall be sized to fit and hold chimney section. Fasteners used to secure chimney sections should not penetrate chimney flue liner. fireplace, no less than 8 (200mm) above the bottom of the first flue tile, by installing a stainless steel or other listed chimney connector from the fireplace damper and smoke chamber, terminating at the first flue tile, or by installing a stainless steel or other listed relining system from the flue outlet up the entire length of the chimney, where necessary. Fig.33 Fig. 32 (50mm) Minimum Clearance 2 (50mm) Air Space 2 (50mm) 1 (25mm) air space to chimney length In Canada when connecting to a masonry fireplace the steel chimney connector must terminate at the top of the masonry chimney or flue liner. MASONRY FIRE PLACE The stove may be installed on the hearth extension of a masonry fireplace. In Canada a continuous line must be provided from the flue collar of the stove to the top of the chimney. In the USA a continuous chimney flue is required. A minimum clearance of 30 (760mm) is required to combustible mantle and a minimum clearance of 22 (560mm) to the side trim, which extends less than 2 (50mm) from the face of the fireplace. (See section under Minimum Clearances to Combustibles ). Before installation, the entire fireplace system should be inspected for condition and code compliance prior to connecting to the the fireplace chimney. Older fireplaces and chimneys may not have been constructed to current relevant codes. The fireplace and chimney should be in, or brought up to, acceptable conditions and proper clearances should be met before connecting to the fireplace chimney. The size of the flue must be considered. If the fireplace chimney is too large, reline using the chimney using an approved relining system. Connection to a masonry chimney may be done by breaching into the chimney from the front of the Fig.34 9

IMPORTANT: BURN WOOD ONLY. DO NOT BURN COAL, SYNTHETIC LOGS OR OTHER FUELS. BURN DIRECTLY ON HEARTH, DO NOT USE A GRATE OR ELEVATE FIRE. NEVER USE GASOLINE, GASOLINE TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUID TO START OR FRESHEN UP A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE. OPERATE STOVE ONLY WITH FUELLING DOOR AND ASHPIT DOOR CLOSED. THIS HEATER IS HOT WHILST IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE A SAFE DISTANCE AWAY. VENTILATION & COMBUSTION AIR REQUIREMENTS Ventilation and adequate air supply is necessary to supply combustion air to the appliance. Refer to your Local Authority for current requirements in your juristriction. Outside combustion air may be required if: 1. The solid-fuel-fired appliance does not draw steadily, smoke rollout occurs, fuels burns poorly, or back drafts occur whether or not there is combustion present. 2. Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smell, do not operate properly, suffer smoke roll-out when opened, or back-draft whether or not there is combustion present. 3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms. 4. The house is equipped with a well-sealed vapour barrier and tight fitting windows and/or has any powered devices that exhaust house air. (e.g extraction hoods and tumble dryers etc.) 5. There is excessive condensation on windows in the winter. 6. A ventilation system is installed in the house. If these or other indications suggest that infiltration air is inadequate, additional combustion air should be provided from the outdoors. Outside combustion air can be provided to the appliance by the following means. 1. Direct connection: Refer to O.S.A. Hook-up in this manual. 2. Indirect method: for an appliance not certified for direct connection of outside combustion air, than (12 ) 300mm from the appliance, to void affecting the performance of the appliance. 3. A mechanical ventilation system: if the house has a ventilation system (air change or heat recovery): a. The ventilation system may be able to provide sufficient combustion make-up air for the solid-fuel-fired appliance. b. The householder should be informed that the ventilation system might need to be re-balanced by a ventilation technician after installation of the appliance. SPILLAGE TEST 1. Light/burn appliance under normal conditions in accordance with this installation manual. 2. Close all doors and windows. 3. Operate all appliances requiring a full rate (eg. extraction hoods, tumble dryers etc). 4. Check for spillage. LIGHTING (a) Replace ashpan (item 37), close ashpit door (item 13), and make sure the ash dump sliding door (item 42) is closed by pushing in ash dump lever (item 54) located at the bottom of the left side panel when looking from the front of stove. (b) Open fire door (item 8) and open the primary air duct (item 55) by pulling the primary air control lever (item 66) located at the right corner under the ashlip (item 12) all the way towards the front. (c) Cover hearth with crumpled pieces of paper. Lay dry pieces of kindling approximately 1 /2 (12mm) x 1 /2 (12mm) x 20 (508mm) long on top of the paper towards the back of the firebox. Ignite and close the fire door (item 8). When the kindling has ignited, open the firedoor (item 8) and add larger pieces of dry wood. Close the firedoor (item 8). When a hot bed of coals is established add the normal fuel of well seasoned split logs approximately 20 (508mm) long. Once the logs are well lighted, adjust the primary air control lever (item 66) to the required output. Refuelling Open the firedoor (item 8) and carefully level the embers and re-load with logs, close the firedoor. NEVER STORE FUEL WITHIN SPACE HEATER INSTALLATION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR CHARGING AND ASH REMOVAL. PRIMARY AIR SETTINGS MAXIMUM Pull control lever (item 66) all the way towards the front. LOW (MIN) Push the control lever (item 66) all the 10

Fig.35 DISPOSAL OF ASHES Remove ash carefully. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in closed container until all cinders have thoroughly cooled. Fig.37 LOW OR OVERNIGHT BURN NOTE: The duration of low or overnight burn is affected by: Draught conditions: Excessive draught reduces burn time. Quality of fuel load. If the stove and flue temperature at the start of a low or overnight burn are too high it will result in reducing burn time. 1. Allow the fire bed to cool down. 2. Re-load using full length wood (preferably unsplit). 3. Do not pack the fuel load as high as the secondary air tubes (item 47). 4. An air space is necessary between the fuel load and secondary air baffle (item 47) to avoid impingement of the secondary air on the top of the fuel load resulting in speeding up the burn rate. 5. Adjust the primary air control lever (item 66) to the minimum setting by pushing it all the way towards the back. MAINTENANCE DO NOT CLEAN STOVE WHEN HOT DE-ASHING (When the fire has burned out) When the ash build-up becomes excessive in the fire chamber (3 1 /2 (88mm) deep or so) it must be removed by allowing the fire to burn out. When the fire has burned out, open the firedoor (item 8). Pull open the ashpit shutter (item 54). The control knob (item 45) for this is on the left hand side of the stove. Rake the ash into the ashpan (item 37) through the grating (item 46) in the centre of the hearth. Push closed the ashpit shutter (item 54) and dispose of the ashes by removing the ashpan (item 37) from the stove. Fig.36 CREOSOTE (Formation and the need for removal) When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The Creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected at least twice monthly during the heating season to determine if a creosote build-up has occurred. If creosote has accumulated it should be removed to reduce the risk of chimney fire. Inspect the chimney connector frequently. Tap the connector with your finger when the pipe is cool. If you hear a dull echo, the pipe may need cleaning. Disassemble the chimney connector and clean the sections. Replace corroded pipe sections. The fitting of a slip-joint in the stove makes the dismantling easy for cleaning and inspection of chimney and stove.replace the empty ashpan (item 37) in the stove, close the ashpit door (item 13) and re-light the fire. When inspecting a masonry chimney, start at the cleanout door, normally found in the basement, at the base of the chimney, or on the outside. If your chimney does not have a clean-out door it must be inspected and cleaned by removing stove from chimney. GLASS REPLACEMENT (a) Open the firedoor (item 8) fully. (b) Remove the four corner screws and clips (items 70) and carefully remove the broken glass. (c) Clean the glass recess in the door. (d) Attach adhesive thermal tape to the perimeter of the replacement glass. (e) Place the thermal taped side of the glass into the 11

firedoor recess and replace the four corner clips (items 70) and screws. (f) Tighten screws. (g) Replace glass only with ceramic glass 3/16 (5mm) thick. Fig.38 FIRE SAFETY To provide reasonable fire safety the following should be given serious consideration. (1) Do not overfire the stove. If the stove or chimney connector glows, you are overfiring. (2) Overfiring will also damage painted or enamel finishes on the stove. (3) The installation of fire detectors. (4) A conveniently located class A fire extinguisher to contend with small fires resulting from burning embers. (5) A practical evacuation plan. (6) A plan to deal with a chimney fire as follows: WARNING: DO NOT OPERATE THE STOVE WITH BROKEN OR CRACKED GLASS. ABUSE SUCH AS STRIKING, SLAMMING AND USE OF SUBSTITUTE MATERIALS SHOULD BE AVOIDED. GLASS CLEANING The glass will clean itself when there is sufficient heat generated by the burning fuel. If a build-up of creosote occurs on the glass due to poor draught conditions, poor quality fuel or very low burning for long periods of time, it is best to clean the glass manually when glass is thoroughly cooled. IN THE EVENT OF A CHIMNEY FIRE (a) Notify the fire department. (b) Prepare occupants for immediate evacuation. (c) Close all openings into the stove. (d) While awaiting the fire department watch for ignition to adjacent combustibles from overheated stove pipe or from hot embers or sparks from the chimney. VITREOUS ENAMEL CLEANING General cleaning must be carried out when the stove is cool. If this stove is finished in a high gloss vitreous enamel, to keep the enamel in the best condition observe the following tips: 1. Wipe over daily with a soapy damp cloth, followed by a polish with a clean dry duster. 2. For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel. 3. DO NOT USE ABRASIVE PADS OR OVEN CLEANSERS CONTAINING CITRIC ACID ON ENAMELLED SURFACES. ENSURE THAT THE CLEANSER MANUFACTUR ERS INSTRUCTIONS ARE ADHERED TO. 12

EXPLODED VIEW ITEM NO. S 1. Leg 2. Base 3. Outer Back Panel 4. Left Hand Side Panel 5. Right Hand Side Panel 6. Front 28. Fire Fence 29. Fire Fence Spike 30. Heat Exchanger 31 Hob 32. Flue Spigot 33. Hob Extension - (Horizontal) 34. Hob Extension - (Vertical) 34A.Knob to Shutter 35. Side Shelf (Optional) 36. Side Shelf Bracket (Optional) 37. Front ADS Assembly 38. Top Air Duct Assembly 40. Side Filler Plates 41. Mesh Cover for Ceramic Blanket 42. Lower Air Box Assembly 43. Left Side Wall Brick 44. Floor Bricks 45. Side Door Insulation Sheet 46. Ceramic Blanket 47. Heatshield 48. Filler Plate 49. Window Glass 50. Window Clip 51. Rope Channel 52. Ash Pan 53. Ash Pan Lifting Tool 54. Door Latch 55. Door Catch 56. Tension Pin 57. Ash Pit Door Handle 58. Ash Door Latch 59. Door Latch 60. Hinge 61. Door Hinge 62. Door Handle 62A.Side Door Handle 63. Door Handle Axle 7. Front Door 8. Door Grille 9. Side Door 10. Side Door Protection Plate 11. Ash Pit Door 12. Front Ash Tray 13. Side Ash Tray 14. Combustion Chamber Base Plate 15. Fire Bed Grate 16. Guide to Ashpit Sliding Door 16A.Ashpit Sliding Door 17. Inner Back Panel 18. Inner Back Panel RH Filler Casting 19. Inner Back Panel LH Filler Casting 21. RH Front Air Duct (Ramp) 22. LH Front Air Duct (Ramp) 23. Outer Air Spigot 24. Inner Air Spigot 25. Damper Spacer 26. Damper Flap (ULC Stoves) 27. Damper Flap (UL Stoves) 64. Spacer to Door Handle 66. Spacer to Door Handle Axle 67. Door Stop 69. Damper Handle 70. Primary Air Flap Axle 71. Primary Air Control Link Rod 72. Primary Air Control Lever 73. Primary Air Control Lever Spacer (Small) 64. Spacer to Door Handle 66. Spacer to Door Handle Axle 67. Door Stop 69. Damper Handle 70. Primary Air Flap Axle 71. Primary Air Control Link Rod 72. Primary Air Control Lever 73. Primary Air Control Lever Spacer (Small) 75. Ashtray Bracket 76. Ashtray Strap 78. Ash Side Shaft 99. Flue Spigot Shield (Optional) 101.Ducting for Optional Fan 102.Optional Fan Assembly 103.Hob Bracket (Optional) 75. Ashtray Bracket 76. Ashtray Strap 78. Ash Side Shaft 99. Flue Spigot Shield (Optional) 101.Ducting for Optional Fan 102.Optional Fan Assembly 103.Hob Bracket (Optional) 13

Manufactured by WATERFORD STANLEY Bilberry, Waterford, Ireland. Tel. 051-302300 Fax 051-302375 14 Rev:004 DP 000302